• Title/Summary/Keyword: Dental impression technique

Search Result 71, Processing Time 0.031 seconds

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Fabrication of immediate complete denture using Campagna tray technique (전악 발치 환자에서 캠퍼그나 트레이를 적용한 즉시의치 수복 증례)

  • Kim, Nam-Hoon;Kim, Jong-Eun;Oh, Kyung Chul;Chung, Moon-Kyu;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.331-335
    • /
    • 2017
  • An immediate complete denture is considered as restoration for lost natural teeth, which is fabricated following the extraction of the remaining teeth. Current esthetics and function can be retained by using immediate denture without edentulous period. However, the major disadvantages of immediate denture relate to the difficulties associated with taking accurate definitive impression and predicting the results of immediate denture. In this case report, the Campagna tray technique was used to take the final impression in a 49-year-old male patient presented with all remaining teeth diagnosed as hopeless teeth. Surgical templates were used for alveoloplasty after extraction. The immediate complete dentures were then delivered. The clinical assessments of immediate dentures showed good esthetic and functional outcomes. The patient showed high level of satisfaction.

The neutral zone approach for restoration of patient with severe mandibular ridge resorption: A case report (하악 치조제가 심하게 흡수된 환자에서 중립대 인상을 통한 총의치 수복 증례)

  • Cheol Namgung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.8-15
    • /
    • 2023
  • In case with severely atrophied mandibular ridges, it may be difficult to achieve adequate retention and stability of dentures through the normal functional impression process of complete dentures. In these patients, an approach using the neutral zone raising technique may be an effective alternative. The neutral zone is defined as the area where the pressure of the tongue towards the outside of the mouth and the pressure of the cheek and lips towards the inside are balanced during the normal oral function of the muscular-nervous system. Complete dentures made through neutral zone impression not only improve retention and stability, but also provide adequate tongue space in the posterior teeth area. Additionally, food residues are reduced in the area around artificial teeth, and aesthetics are improved through appropriate facial support.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

AGAR-ALGINATE COMBINED IMPRESSION TECHNIQUE AND DIMENSIONAL CHANGE RESULTING FROM IDOPHOR DISINFECTION (아기-알지네이트 연합 인상체의 보관방법 및 idophor 침적소독에 의한 체적 변화에 관한 연구)

  • Oh Nam-Sik;Seo Joung-Min;Kim Sun-Hee;Youn Young-Ah;Shim Joon-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Statement of problem : Because dental impression can be a cross-infection source, disinfection, such as immersion disinfection is nessecary. However, the disinfection process may change the volume of the impression cast. Purpose : The purpose of this study is to find out the effects on dimensional change of different storage times and methods, of agar-alginate impression when immersed in a 5% idophor disinfectant. Material and Methods : An agar-alginate impression was made from a mandible model and then was disinfected and stored according the experimental conditions and a stone model was produced. Measurements were taken between reference points on the original mandible model and they were compared to measurements taken between reference points on the stone model. The study was divided into 4 groups. In group 1, the impression was stored in a 100% humidor for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours and 24 hours and stone models were made at each time. In group 2, the impression was immersed in 5% idophor disinfectant and then stored in a 100% humidor for the same length of times as group 1, and stone models were made at each time. In group 3, the impression was stored in extend-A-pourR, a special storage solution for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours, 24 hours 3 days, and 7 days and stone models were made at each time. In group 4, the impression was immersed in 5% idophor disinfectant and then stored in stored in extend-A-pourR, a special storage solution for the same length of times as group 3, and stone models were made at each time. 5 impressions and stone models were made at each time to make a total of 180. The Student-t test (P < .05) was used to do a statistical analysis of the measurements of the mandible model and stone models. The repeated-measure 2-way analysis of variance (P < .05) was used to do a statistical analysis of the difference in the 4 groups. Results : The percent liner dimensional change was from $0.25{\pm}0.03%$ (group 1, 30 minutes) to $0.34{\pm}0.06%$ (group 4, 7 days). No significant change was noticed between the 4 groups. Conclusion : According to the above study, in both methods, least dimensional change was recorded when the storage times were short and in both methods, immersion in 5% idophor disinfectant did not effect dimensional change in the agar-alginate impression.

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.