• 제목/요약/키워드: Dental impression material

검색결과 97건 처리시간 0.022초

가변형 치과 인상용 트레이의 적합도에 관한 예비연구 (A Preliminary Study on the Fitness of Adjustable Dental Impression Trays)

  • 김민정;오상천;동진근
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

한국인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구 (THE FITNESS OF ADJUSTABLE DENTAL IMPRESSION TRAYS ON THE KOREANS)

  • 김태영;동진근;조혜원
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.477-487
    • /
    • 2006
  • Purpose : this study was to evaluate the fitness of adjustable dental impression trays on the Koreans : the trays used in the previous study by Kim et al. as part of the dental adjustable tray development project were improved and modified. Material and method: The patterns of tray were made through CAD-CAM process, and a simple silicone-base molds were made from them. The trial products were reproduced by pouring polyurethane into these molds. 30 male students(Wonkwang University, Dental College) and 30 female students (Wonkwang Health Science College, Department of Dental Hygiene) were selected and Reversible hydrocolloid impression materials were used for this study. The fitness of the trays was evaluated by measuring the width and length of impression materials of each measurement sites. Results and conclusion : 1. In adapting the trays inside the mouth, a uniform width of impression material(3 $\sim$ 6mm) was obtained in most sites due to the tooth stops and the inclined planes accommodating the width of the tray 2. The thickness of impression material in the central part of the palate was a mean 9.8mm, which turned out to be somewhat thick. 3. In the mandible. the thickness of the impression material in the lingual side inferior to the contact point of the 1st and 2nd molars was 2.7mm, and the thickness of the material in the lingual side of the rearmost margin was 2.5 mm. The thickness of the impression material of these areas was relatively thin.

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • 대한치과의사협회지
    • /
    • 제41권1호통권404호
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화 (Change master cast by hardening method to position of tray after impression taking)

  • 이정애
    • 한국치위생학회지
    • /
    • 제8권2호
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

성공적인 총의치 제작을 위한 단계별 포인트 - 무치악인상채득, 이것이 핵심이다. (Clinical considerations of impression making for edentulous patients)

  • 박찬진
    • 대한치과의사협회지
    • /
    • 제55권1호
    • /
    • pp.72-81
    • /
    • 2017
  • Regardless of the type of impression being made, the tray is the most important part of the impression-making procedure for completely edentulous patients. Dentists have to make use of a combination of rigid, thermoplastic, and resilient materials and control step-by-step procedure from irreversible hydrocolloid impression to definitive cast fabrication. For successful edentulous impression, some considerable clinical tips were guided.

  • PDF

치과용 인상재의 젖음성 및 경화시간 비교 (Comparison of wettability and setting time of dental impression materials)

  • 김병진;송근호;이광래
    • 산업기술연구
    • /
    • 제36권
    • /
    • pp.45-48
    • /
    • 2016
  • The purpose of this study is to evaluate and compare wettability and setting time of twelve polyvinylsiloxane impression pastes. For comparing the wettability, the contact angle of a water drop on the impression materials was measured. It is important for impression materials to have higher wettability when trying to make impressions of interproximal spaces and gingival crevices. The higher wettability the better the material will flow into these spaces and the more accurate the impression. An ideal impression material will have adequate working time but a fast intraoral setting time. The clinician needs time to inject material into the sulcus, place the impression material into the tray and position it in the mouth, but the material should set rapidly to reduce time in the patient's mouth. It is considered that the results obtained in this study will provide guideline information for the manufacturing of impression materials and for selecting appropriate impression materials.

  • PDF

한국인 성인에 대한 기성 tray의 적합도에 관한 연구 (A STUDY ON THE FITNESS OF STOCK TRAY IN KOREAN ADULTS)

  • 송대성;진태호;동진근
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.131-141
    • /
    • 1989
  • This study was designed to investigate the fitness of stock tray in Korean adults. 107 dental students (male: 87, female: 20) who have normal occlusion and symmetric facial fom were selected. The upper and lower stock tray (Osungtray, Osung Co., Korea) fit with dental arch were selected for taking irreversible hydrocolloid impression. The author measured the thickness of impression material about two items, that is, width and length on the flange of stock tray. Several measuring points on the dental arches and palatal area were checked with Goldman Fox prove (Hu-Friedy, U.S.A.). The obtained results were as follows: 1. The width of impression material on buccal flange of upper and lower trays were narrower than any other measuring point, but the thickness of impression material on the palatal area of upper stock tray was the widest of all measuring points. 2. The length on buccal flange of lower stock tray was shorter, but the length on tray flange of lower stock tray at lingual frenum area was longer. 3. On upper dental arch, the upper extra-large tray was used in 53% of subjects, but upper small tray was not used. 4. On lower dental arch, the large tray was used in 55% of subjects. 5. There was not adequate tray on upper dental arch in 4 subjects.

  • PDF

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

계면활성제와 소포제가 실리콘 고무인상재의 물성에 미치는 영향 (Effect of Surfactant and Anti-foaming Agent on the Properties of Silicone Rubber Impression Material)

  • 김경남;조리라;오영일;강승경;정경호
    • Elastomers and Composites
    • /
    • 제36권2호
    • /
    • pp.102-110
    • /
    • 2001
  • Nonylphenoxy poly(ethylene) ethanol homologues, caster oil poly(ethylene) ethanol homo-logues 및 sodium perfluoroalkyl carboxylates의 세 가지 종류 계면활성제를 사용하여 고무인상재의 젖음성 향상 연구를 수행한 결과 불소 관능기가 도입된 sodium perfluoroalkyl carboxylates 계면활성제의 경우 다른 계면활성제를 사용한 경우에 비해 고무인상재의 초기 표면에너지 값은 유사했으나 평형상태에 이른 후의 표면에너지 값이 낮아 치아와의 젖음성이 가장 우수한 것으로 나타났다. 또한, 수소가스의 발생을 억제시키고 미세부 재현성을 높이기 위해 소포제를 사용한 결과 젖음성이 향상된 sodium perfluoroalkyl carboxylates를 포함한 조성에 소포제를 첨가할 경우 인열물성이 약 40% 이상 증가하였는데, 이는 소포제가 고무인상재 내부의 반응으로 생성되는 수소가스의 발생을 억제하기 때문이다. 따라서, 소포제는 고무인상재의 표면특성에는 크게 영향을 미치지 않으면서 인상재 내부에 발생되는 기포를 효과적으로 억제 혹은 제거하여 고무 인상재의 기계적물성을 향상시킴을 알 수 있었다.

  • PDF