• Title/Summary/Keyword: Dental implant surgery

Search Result 807, Processing Time 0.04 seconds

Effects site concentrations of propofol using target-controlled infusion in dental treatment under deep sedation among different intellectual disability types

  • Keyling, S;Salmeron, Salinas;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.4
    • /
    • pp.217-226
    • /
    • 2019
  • Background: We aimed to assess the dose needed to achieve the propofol effect-site concentration using target-controlled infusion in intellectually disabled patients and to detail the most effective method for achieving a safe level of consciousness without hemodynamic changes as well as detail any resulting adverse effects. Methods: We performed a retrospective review of sedation service records of 138 intellectually disabled patients (51, mental retardation; 36, autism; 30, brain lesion, 12 genetic diseases, 9 dementia) aged over 15 years and weighing over 30 kg. These patients had received propofol via target-controlled infusion in the special care dental clinic of Seoul National University Dental Hospital from May 2008 to September 2018 for restorative treatment (112), minor surgery (13), prosthodontics (7), periodontics treatment (5), and implant (1). Results: For all groups, the duration of dental treatments was $43{\pm}18$ minutes, total sedation time was $73{\pm}23$ minutes, and total BIS values was $57{\pm}12$. The propofol maintenance dosage values for each group were: mental retardation, $3{\pm}0.5(2-4){\mu}g/ml$; autism, $3.1{\pm}0.7(2-5){\mu}g/ml;$; brain lesion, $2.8{\pm}0.7(1.5-5){\mu}g/ml;$; genetic disease, $2.9{\pm}0.9(1-4){\mu}g/ml;$ and dementia $2.3{\pm}0.7(1-3.4){\mu}g/ml;$. Conclusions: The dementia group needed a lower dosage to reach a safe, effective propofol effect-site concentration than the other groups. Since there were no complications, deep sedation is a great alternative to general anesthesia for dental treatment of intellectually disabled patients.

A novel brief questionnaire using a face rating scale to assess dental anxiety and fear

  • Takuya Mino;Aya Kimura-Ono;Hikaru Arakawa;Kana Tokumoto;Yoko Kurosaki;Yoshizo Matsuka;Kenji Maekawa;Takuo Kuboki
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.4
    • /
    • pp.244-254
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the reliability and validity of a four-item questionnaire using a face rating scale to measure dental trait anxiety (DTA), dental trait fear (DTF), dental state anxiety (DSA), and dental state fear (DSF). MATERIALS AND METHODS. Participants were consecutively selected from patients undergoing scaling (S-group; n = 47) and implant placement (I-group; n = 25). The S-group completed the questionnaire both before initial and second scaling, whereas the I-group responded on the pre-surgery day (Pre-day), the day of implant placement (Imp-day), and the day of suture removal (Post-day). RESULTS. The reliability in the S-group was evaluated using the test-retest method, showing a weighted kappa value of DTA, 0.61; DTF, 0.46; DSA, 0.67; DSF, 0.52. Criterion-related validity, assessed using the State-Trait Anxiety Inventory's trait anxiety and state anxiety, revealed positive correlations between trait anxiety and DTA/DTF (DTA, ρ = 0.30; DTF, ρ = 0.27, ρ: correlation coefficient) and between state anxiety and all four items (DTA, ρ = 0.41; DTF, ρ = 0.32; DSA, ρ = 0.25; DSF, ρ = 0.25). Known-group validity was assessed using the initial data and Imp-day data from the S-group and I-group, respectively, revealing significantly higher DSA and DSF scores in the I-group than in the S-group. Responsiveness was gauged using I-group data, showing significantly lower DSA and DSF scores on post-day compared to other days. CONCLUSION. The newly developed questionnaire has acceptable reliability and validity for clinical use, suggesting its usefulness for research on dental anxiety and fear and for providing patient-specific dental care.

A review of biocompatibility of zirconia and bioactivity as a zirconia implant: In vivo experiment (지르코니아의 생체적합성과 임플란트로서의 생체활성에 대한 연구: In vivo 실험 문헌 고찰)

  • Suh, Da-Won;Kim, Young-Kyun;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.88-94
    • /
    • 2019
  • Increasing demands for esthetic dental treatment, zirconia, which has high mechanical and esthetic properties, had been applied more and more in clinics. Therefore, assessment of biocompatibility of zirconia is necessary. In this article, a review of in vivo studies of zirconia compatibility was performed. In vivo studies showed zirconia had great biocompatibility both on soft and hard tissue. Studies with various animals and patients reported high biocompatibility of zirconia. In terms of bone synthesis and bone adhesion, zirconia showed similar biocompatible properties to titanium. On the other hand, zirconia could be used as implant. For using as an implant, various methods of Hydroxyapatite (HA) coating had been suggested. Since HA coating on titanium implant showed some problems such as low bonding strength and degeneration of HA, HA-zirconia composite, HA-coated zirconia, and HA-zirconia functionally graded material (FGM) or intermediate layer of alumina had been proposed. These methods showed higher bonding strength and biocompatibility.

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Antimicrobial susceptibility and pathogenic genes of Staphylococcus aureus isolated from the oral cavity of patients with periodontitis

  • Kim, Ga-Yeon;Lee, Chong Heon
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.223-228
    • /
    • 2015
  • Purpose: The goal of this study was to characterize the patterns of antimicrobial resistance and virulence genes in samples of Staphylococcus aureus (S. aureus) isolated from periodontitis patients. Methods: From July 2015 to August 2015, oral saliva was collected from a total of 112 patients diagnosed with periodontitis, including 80 outpatients in dental hospitals and 32 patients in dental clinics located in Seoul and Cheonan. The samples were subjected to a susceptibility test to evaluate the prevalence of antimicrobial resistance, and the pathogenic factors and antimicrobial resistance factors in the DNA of S. aureus were analyzed using polymerase chain reaction. Results: A susceptibility test against 15 antimicrobial agents showed that 88% of cultures were resistant to ampicillin, 88% to penicillin, and 2% to oxacillin. Resistance to at least two drugs was observed in 90% of cultures, and the most common pattern of multidrug resistance was to ampicillin and penicillin. Enterotoxins were detected in 65.9% of samples. The cell hemolysin gene hld was detected in 100% of cultures and hla was detected in 97.6% of samples. All strains resistant to penicillin and ampicillin had the blaZ gene. The aph(3')IIIa gene, which encodes an aminoglycoside modifying enzyme, was detected in 46.3% of samples. Conclusions: In the treatment of oral S. aureus infections, it is important to identify the pathogenic genes and the extent of antimicrobial resistance. Furthermore, it is necessary to study patterns of antimicrobial resistance and cross-infection in the context of periodontological specialties in which antimicrobials are frequently used, such as maxillofacial surgery, where the frequency of antimicrobial use for minor procedures such as implant placement is increasing.

A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis

  • Oziunas, Rimantas;Sakalauskiene, Jurgina;Jegelevicius, Darius;Januzis, Gintaras
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.70-77
    • /
    • 2022
  • PURPOSE. This study evaluated screw loosening and 3D crown displacement after cyclic loading of implant-supported incisor crowns cemented with original titanium bases or with three compatible, nonoriginal components. MATERIALS AND METHODS. A total of 32 dental implants were divided into four groups (n = 8 each): Group 1 used original titanium bases, while Groups 2-4 used compatible components. The reverse torque value (RTV) was evaluated prior to and after cyclic loading (1,200,000 cycles). Samples (prior to and after cyclic loading) were scanned with a microcomputed tomography (micro-CT). Preload and postload files were superimposed by 3D inspection software, and 3D crown displacement analysis was performed using root-mean-square (RMS) values. All datasets were analyzed using one-way ANOVA and Tukey's post hoc analysis. RESULTS. Significant variations were observed in the postload RTV, depending on the titanium base brand (P < .001). The mean postload RTVs were significantly higher in Groups 1 and 2 than in the other study groups. While evaluating 3D crown displacement, the lowest mean RMS value was shown in the original Group 1, with the highest RMS value occurring in Group 4. CONCLUSION. Within the limitations of this in vitro study and under the implemented conditions, it was concluded that the manufacturer brand of the titanium base significantly influenced screw loosening following the fatigue test and influenced 3D crown displacement after cyclic loading.

Structural equation modeling for association between patient satisfaction and quality of life after implant surgery (임플란트 만족도와 삶의 질 간의 관련성에 대한 구조방정식모델 분석)

  • Chung, Sun-Young;Cho, Jin-Hyun;Lee, Kyu-Bok;Choi, Youn-Hee;Song, Keun-Bae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.291-299
    • /
    • 2011
  • Purpose: This study was designed to measure patient satisfaction and oral health-related quality of life and to assess an association between patients' satisfaction and oral health-related quality of life after implant surgery by using structural equation modeling. Materials and methods: A total of 257 participants who visited 6 dental clinics located in Daegu city for the purpose of implant treatment participated in this study. Six months after completion of implant surgery, the patients' satisfaction and oral health-related quality of life were surveyed. The effect of factors associated with patients' satisfaction such as functions and aesthetics, maintenance and cost on oral health-related quality of life after implant surgery was analyzed using AMOS 4.0. Results: Oral health-related quality of life was improved in all dimensions of OHIP-14 after implant surgery. Functions and aesthetics as well as maintenance had a significant effect on oral health-related quality of life (P<.05), while cost was not a critical factor influencing oral health-related quality of life. Conclusion: High satisfaction with functional aspects and maintenance aspects significantly affected good quality of life. The result of this study supported the fact that education and management for patients after implant therapy were positively related to good quality of life based on a theoretical model.

Effects of fibrin-binding oligopeptide on osteopromotion in rabbit calvarial defects

  • Lee, Ju-A;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Park, Yoon-Jeong
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.211-219
    • /
    • 2010
  • Purpose: Fibronectin (FN) has been shown to stimulate bone regeneration in animal models. The aim of this study was to evaluate the capacity of bovine bone mineral coated with synthetic oligopeptides to enhance bone regeneration in rabbit calvarial defects. Methods: Oligopeptides including fibrin-binding sequences of FN repeats were synthesized on the basis of primary and tertiary human plasma FN structures. Peptide coated and uncoated bone minerals were implanted into 10 mm calvarial defects in New Zealand white rabbits, and the animals were sacrificed at 4 or 8 weeks after surgery. After specimens were prepared, histologic examination and histomorphometric analysis were performed. Results: At 4 weeks after surgery, the uncoated groups showed a limited amount of osteoid formation at the periphery of the defect and the oligopeptide coated groups showed more osteoid formation and new bone formation in the center of the defect as well as at the periphery. At 8 weeks, both sites showed increased new bone formation. However, the difference between the two sites had reduced. Conclusions: Fibrin-binding synthetic oligopeptide derived from FN on deproteinized bovine bone enhanced new bone formation in rabbit calvarial defects at the early healing stage. This result suggests that these oligopeptides can be beneficial in reconstructing oral and maxillofacial deformities or in regenerating osseous bone defects.

Modern Possibilities and Prospects of Nanotechnology in Dentistry

  • Sergiy, Chertov;Valery, Kaminskyy;Olha, Tatarina;Oleksii, Mandych;Andrii, Oliinyk
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.10
    • /
    • pp.97-106
    • /
    • 2022
  • Objective. Nanotechnology is spreading among all areas of life, from everyday devices to medicine. The concept of nanotechnology argues that not only can new physical and chemical properties of materials be discovered, but also the new potential of nanostructures when reduced to the nanoscale. The growing interest in the application of nanomaterials in dentistry contributes to the proliferation of the range of nanomaterials used by specialists. The purpose of this review of information sources was to analyze the prospects for the use of nanomaterials in dentistry. Methods. We used the bibliographic semantic method of research, for which we analyzed electronic databases of primary literature sources Scopus, Web of Science, Research Gate, PubMed, MDPI, and MedLine. English-language scientific articles published after 2017 were taken into consideration. Results. According to the results of a search study among modern information primary sources, nanotechnology improves the preventive properties of oral care products, improves the structural-mechanical and aesthetic properties of composite mixtures for dentistry, overcomes the problems of the clinical application of dental implants. Despite the prospects of nanotechnology applications in medicine in general and dentistry in particular, the existing economic and technological problems require a thorough solution for further implementation of nanostructures. Scientific novelty. For the first time, the analysis of modern trends in the application of nanotechnology in dentistry is carried out and the peculiarities of materials are highlighted, the problems and prospects of nanostructures implementation in modern dental implantology are given, physical, chemical, mechanical, and antibacterial properties of nanomaterials are evaluated. The effect of nanomaterials on the microbial adhesion of the tooth or implant surface is described. Practical significance. The presented publication can become a scientific basis for the solution of urgent problems hindering the introduction of nanotechnology into dental practice. Conclusions. Thus, the use of nanostructures opens up great opportunities for the treatment of a wide range of diseases, not only of dental nature but also in medicine in general.