• Title/Summary/Keyword: Dental implant surgery

Search Result 806, Processing Time 0.032 seconds

EFFECTS OF OSSEOINTEGRATION ACCORDING TO IMPLANT PLACEMENT TIMING IN THE DISTRACTED ALVEOLAR BONE OF DOGS (치조골 신연 후 임프란트 매식 시기에 따른 골유착 효과)

  • Jung, Hyun;Oh, Hee-Kyun;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.3
    • /
    • pp.238-244
    • /
    • 2000
  • The present study was aimed to investigate the effect of osseointegration according to implant placement timing in the distracted alveolar bone using intraoral distraction device. Six adult mongrel dogs of either sex, weighing about 15kg, were used. The animals were divided into 4-week and 8-week groups according to the timing of implant installation. The left upper and lower premolars and first molars were extracted and an alveoloplasty was performed to simulate an atrophic ridge. After 12 weeks of healing, a segmental osteotomy was made and an intraoral distraction device which was designed for augmentation of vertical height of the edentulous ridge was applied. Latency period was allowed for 5 days and then distraction was made at a rate of 1.2mm/day for 8 days. Four or eight weeks after distraction, implants were installed. Twelve weeks after implant installation, the animals were sacrificed. Macroscopic, radiographic, and histologic examinations of distracted alveolar ridge were performed. No significant abnormalities such as infection and dehiscence of overlying soft tissue were observed. Radiographically, there was slight bone resorption around the medial and distal edges of the alveolar bone segment, and a new bone deposition was observed in the neighboring alveolar crest area in the both groups. The satisfactory osseointegration was achieved in the distracted gap of the both groups, but fibrous tissue appeared on the buccal side of implant in the distracted gap in 4-week group. These results suggest that proper timing of implant installation is 8 weeks rather than 4 weeks after distraction when dental implant is to be placed onto the distracted bone.

  • PDF

STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS (상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석)

  • Kim, Han-Koo;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

SINUS AUGMENTATION WITH ${\beta}$-TCP (${\beta}$-TCP를 이용한 상악동 점막거상술)

  • Hwang, Kyung-Gyun;Song, Seung-Il;Kim, Sang-Woo;Lee, Sung-Hoon;Kim, Young-Muen;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.428-433
    • /
    • 2004
  • Sinus floor augmentation has been proven an effective treatment procedure to increase bone volume in the posterior edentulous maxilla. Autogenous bone considered to be the best material for reconstructive bone surgery and has been successfully used as a graft material to augment posterior maxilla. However, the collection of autogenous bone required extra risks for morbidity and complaints. So, various bone graft materials included ${\beta}$-tricalcium phosphate(${\beta}$-TCP) has been introduced for replacing the autogenous bone. The objective of this clinical study was to determine the predictability of endosseous implant placed in a maxillary sinus with ${\beta}$-TCP grafting. We performed sinus elevation with ${\beta}$-TCP to install the implant in the 10 maxillary cases. The prosthetic procedure was performed 6-9 months after. The implant-prosthetics was checked about 1 year. We checked the implant and measured the maximum bite force to evaluate the function of the implant. There was not observed the specific problem and complication in dental implant and maxillary sinus in the grafted materials. The maximum bite force was 558N in case of natural tooth, 365N in implant without grafting, 318N in implant with ${\beta}$-TCP grafting. There was no significant difference between with and without sinus grafting on maximum bite force(p>0.05). As though the long term check-up is needed, the grafting of ${\beta}$-TCP as a osteoconductive materials can expand the volume and induce dense new bone formation in maxillary sinus. So, this short-term results support that ${\beta}$-TCP can be a suitable material for sinus augmentation.

A multicenter clinical study of installed US II Plus/GS II Osstem implants after bone graft (골 이식술 후 Osstem Implant (US II Plus/GS II)의 다기관 임상연구)

  • Chung, Kwang;Oh, Chul-Jung;Ha, Ji-Won;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Kim, Su-Gwan;Kim, Young-Kyun;Kim, Woo-Cheol
    • The Journal of the Korean dental association
    • /
    • v.50 no.12
    • /
    • pp.743-754
    • /
    • 2012
  • urpose : The purpose of this study was to evaluate the US II plus/GS II Osstem$^{(R)}$ implants through the study for the clinical success rate during the installation of the Osstem¢Á implants after bone graft. Materials and Methods : This study was researched in the 4 medical institutions: Chonnam National University, Chosun University, Bundang Seoul National University Hospital, and FM dental clinic from May, 2002 to September, 2009. Based on the total number of 60 patients whose treatment was the installation of the US II plus/GS II Osstem¢Á implants after bone graft, we evaluated success rate of implants. We analysis the distribution of patient's age and gender, edentulous area, bone type, fixture length and diameter, installation and loading time, donor site, bone graft material and method, antagonistic teeth, and survival and success rate. From these analyses we got the following results. Results : 1. In this study, the total number of patients who have been installed with US II plus implant was 27, and total of 52 implants were installed. The average age was 38.9, with 16 male, and 11 female patients. 2. The total number of patients who have been installed with GS II implant was 33, and total of 54 implants were installed. The average age was 49.7, with 24 male, and 9 female patients. 3. As for bone graft method, either autogenous bone or a mix of autogenous and heterogenous bone was used(88.4%) for US II plus. Chin, iliac, and Maxillary tuberosity were the donor sites for autogenous bone graft, and onlay method of bone graft was performed. 4. Allogenic bone or a mix of autogenous and heterogenous bone was used(77.8%) for GS II. Chin, ramus, and tibia were the donor sites for autogenous bone graft, and GBR method of bone graft was performed. 5. The duration from the installation of implants to setting of final prosthesis was average of 16 months and 10 months for US II plus and GS II respectively. Also, the final follow up period was average of 31 months and 28 months respectively. During this period, one GS II implant was removed from 1 patient due to failure of early osteointegration. 6. The survival rates were 100% and 98.1%, and success rates were 94.2% and 94.4% for US II plus and GS II implant respectively. Conclusion : On the evaluation of our clinical study, both US II plus and GS II Osstem¢Á implants showed the excellent clinical results after bone graft.

Clinical and radiographic evaluation of implants with dual-microthread: 1-year study (이중미세나사산 임플란트의 임상적 및 방사선학적 1년 평가)

  • Kwon, Mi-A;Kim, Yong-Deok;Jeong, Chang-Mo;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.1
    • /
    • pp.27-36
    • /
    • 2009
  • Purpose: The stability of periodontal condition and marginal bone level were important to achieve long-term success of dental implant treatment. The aim of this study was to evaluate periodontal conditions and marginal bone loss around 67 GSII(OSSTEM, Seoul, Korea) dental implants with dual-microthread at the neck portion, 1 year after prosthetic loading. Materials and methods: Sixty-seven GS II dental implants in 27 patients(mean age; $47.4{\pm}14.0$ years) who received implant treatments at Pusan National University Hospital, were included in this study. Thirteen US II(OSSTEM, Seoul, Korea) implants with smooth neck design were selected for the control group. Periodontal and radiographic evaluations were carried out at baseline, 6 months and 12 months after prosthetic loading. Results: In the GS II group, plaque index(PI), gingival index(GI) and probing depth(PD) increased as time passed. In the US II group, GI and PD increased. Although marginal bone level was lower in the US II group in all evaluation periods, the changes between the periods were not statistically significant(p>0.05). In each period, periodontal parameters were not statistically significant between groups. Conclusion: One year after prosthetic loading, GS II and US II dental implants showed similar periodontal conditions and marginal bone response, and were within the criteria of success.

STABILITY OF SIMULTANEOUS IMPLANTATION WITH AUTOGENOUS ILIAC BONE GRAFT IN THE SEVERELY ATROPHIC MAXILLA (심하게 흡수된 상악골에서 자가 장골 이식술과 동시에 시행한 임프란트 치료의 안정성에 대한 연구)

  • Byun, June-Ho;Park, Bong-Wook;Jeong, Hee-Chan;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.570-578
    • /
    • 2006
  • A severely atrophic maxilla may disturb the proper implant placement. The various bone graft techniques are required for simultaneous or delayed implantation in the cases of atrophic alveolar ridges. We present 11 consecutive patients treated with simultaneous implantation using the autogenous inlay and/or onlay bone grafts from iliac crest to the floor of the maxillary sinus and the alveolar crest. In the cases of atrophic maxilla, a total 69 implants were simultaneously placed with autogenous iliac bone graft. 40 fixtures were inserted in the sinus floor simultaneously with subantral block bone graft, the other 29 fixtures were placed in the anterior or premolar areas with block or particulate bone graft. The vertical alveolar bone height was measured with Dental CT at the preoperation and 6 months postoperation. Moreover, the implant stability quotients (ISQ) were measured by $Osstell^{TM}$ during second implant surgery at 6 months later of first implantation. All implants were obtained successful osseointegration with the grafted bone. The mean vertical increases were 3.9mm in the anterior ridges and 12.8mm in the posterior ridges. During the second implant surgery, mean ISQ were 62.95 in the anterior ridge and 61.32 in the posterior ridge. We concluded that the simultaneous implantation with autogenous iliac bone graft were stable and available methods for severely atrophic maxilla.

Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads (Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구)

  • Chee, Young-Deok;Lee, Jae-Hwan;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.417-429
    • /
    • 2009
  • Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved and accepted as viable option for the treatment of fully and partially edentulous patients. Although the use of domestic implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. 96 endosseous implants placed in 31 patients at Wonkwang University Sanbon Dental Hospital were examined to determine the effect of various factors on implant survival rate and marginal bone loss, through clinical and radiographic results. The design of endosseous implant used to this study is straight with the microthread.(GS II RBM Fixture) 1. 3 fixtures were lost, resulting in 96.9% cumulative survival rate. 2. Survival rate in fifties was significantly lower (93.6%) and no significant difference in marginal bone loss was found according to gender. 3. Survival rates were 95.6% in the maxillary molar area and 97.3% in the mandible molar area. 4. No significant difference in survival rate was found according to presence of bone grafts, type of prostheses, implant position, and length and diameter of implant. 5. A factor influencing marginal bone loss was presence of type of prostheses, while facters such a length, diameter of fixture and bone grafts had no statistically significant effect on crestal bone loss. This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Immunomodulation for maxillofacial reconstructive surgery

  • Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.5.1-5.9
    • /
    • 2020
  • Immunomodulation is a technique for the modulation of immune responses against graft material to improve surgical success rates. The main target cell for the immunomodulation is a macrophage because it is the reaction site of the graft and controls the healing process. Macrophages can be classified into M1 and M2 types. Most immunomodulation techniques focus on the rapid differentiation of M2-type macrophage. An M2 inducer, 4-hexylresorcinol, has been recently identified and is used for bone grafts and dental implant coatings.

The comparative study - the regenerative effect depends on size of bone graft material in bone loss site around dental implant (임플란트 주위 골 결손부의 이식재 크기에 따른 재생 효과 비교 연구)

  • O, Hong-Kyun;Hong, Ki-Seok;Chung, Chin-Hyung;Yim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.493-502
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate on the regenerative capacity by using different size of graft materials around bony defect around implant. Material and Methods: Dental implant fixtures(Bio-TIS, Korea) were placed into the tibia of 8 rabbits. After placement of implant, artificial defects were created for each group, and the size of bone graft materials were used according to each designated group. 4 weeks after surgery, 8 rabbits were sacrificed. The histologic and histomorphometrical study were done for comparison of the regenerative capacity using $80-90{\mu}m$ and $200{\sim}1000{\mu}m$ size of grafting materials of OCS-$B^{(R)}$. Result: Matured bone formation was significantly increased more in Group E1($80-90{\mu}m$) than in Group E2($200{\sim}1000{\mu}m$). Group E1($80-90{\mu}m$) showed more significant augmentation in marginal length of graft material per unit area than Group E2($200{\sim}1000{\mu}m$). Group E1($80-90{\mu}m$) showed more interspace in graft material than Group E2($200{\sim}1000{\mu}m$). Control group showed no new bone formation around and inside of implanted fixture. Conclusion: Small grafting material size has great influence on bone regeneration.

Surgical Invasiveness is Important for Determining Severity of Postoperative Pain after Oral & Maxillofacial Surgery (구강악안면 수술의 침습도 및 술 후 통증의 정도와의 상관성)

  • Shin, Teo-Jeon;Park, Yun-Ki;Seo, Kwang-Suk;Han, Hyo-Jo;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • 배경: 술 후 통증은 술 후 합병증의 발생가능성을 증가시키며 생체기능의 회복을 방해한다. 술 후 통증을 효과적으로 조절하기 위해선 통증의 정도를 객관적으로 평가하는 것이 필요하다. 술 후 통증은 수술의 침습도와 관련이 높을 가능성이 많다. 본 연구에서는 수술 침습도의 정도와 술 후 통증의 정도 사이의 상관관계를 확인하고자 한다. 방법: 총 153명의 환자를 수술의 침습도에 따라 4개의 그룹으로 나누었다(그룹 1: 악성종양 수술 (malignancy surgery), 그룹 2: 양악수술(bimaxillary surgery), 그룹 3: 양성 종양수술(benign cancer surgery) 그룹 4: 임플란트 & 골절 수술(implant & frature)) 수술이 끝나갈 무렵 fentanyl 700 ${\mu}g$, ketorolac 1,500 mg (총 용적 120 ml)가 포함된 자가통증조절장치를 정맥로에 연결하였다. 술 후 통증의 정도는 시각통증등급(visual analogue scale)을 이용하여 측정하였고 자가통증조절장치의 총 사용시간, 투여된 진통제의 양, bolus 투여 총 횟수를 측정하였다. 결과: 술 후 시각통증등급은 술 후 1일부터 3일까지 그룹 1, 2 군에서 유의하게 높았다. 또한 시각통증등급 3점 이상의 통증을 호소하는 환자의 비율 역시 그룹 1, 2 군에서 유의하게 높았다. 진통제 총 투여용량 및 자가로 주입한 진통제의 양 역시 그룹 1, 2군에서 3, 4 군에 비해 유의하게 높은 것을 확인하였다. 결론: 본 연구결과 외과적 수술의 침습도가 술 후 통증의 정도를 결정하는데 있어 중요한 요소임 을 확인하였다.