• Title/Summary/Keyword: Dental implant prostheses

Search Result 212, Processing Time 0.029 seconds

A STUDY ON CYTOTOXICITY OF THE NEW TITANIUM ALLOYS FOR DENTAL IMPLANT MATERIAL (Dental Implant 금속재료의 성분차이에 따른 세포독성에 관한 연구)

  • Kim, Tae-In;Han, Jun-Hyun;Lee, In-Seok;Lee, Kyu-Hwan;Shin, Myung-Chul;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.675-686
    • /
    • 1996
  • Today, dental implants are an acceptable alternative, capable of providing bone-anchored fixed prostheses for improved quality of life and self esteem for many patients. Research advances in dental implantology have led to the development of several different types of materials, and it is anticipated that continued research will likewise lead to advanced dental implant materials. Currently used pure titanium has relatively low hardness and strength which possibly limits its ability to resist the functional loads as a dental implant. Ti-6Al-4V also has potential problems such as corrosion resistance, bone biocompatibility etc. The carefully selected Zr, Nb, Ta, Pd, In constituents could improve mechanical strength, corrosion resistance, and biocompatibility compared to that of currently used implant metals. On the basis of the totality of the data from our study, it can be concluded that new titanium alloys containing Zr, Nb, Ta, Pd, In are able to provide improved mechanical properties, corrosion resistance and biocompatibility to warrant further investigation of it's potential as new biomaterials for dental implants.

  • PDF

Analysis of Implant Prosthesis using 2-Dimensional Finite Element Method (2차원유한요소분석을 이용한 임플란트 보철물의 적합도 분석)

  • Kwon, Ho-Beom;Park, Chan-Je;Lee, Seok-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.341-348
    • /
    • 2006
  • Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

Analysis of Implant Prosthesis Using 2-Dimensional Finite Element Method (2차원 유한요소분석을 이용한 임플란트 보철물의 적합도 분석)

  • Kwon, Ho-Beom;Park, Chan-Je;Lee, Seok-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.251-260
    • /
    • 2006
  • Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

How can improve the insufficient success rate at immediate loading? (임상가를 위한 특집 1 - Immediate loading 부족한 성공률 5% 채우기)

  • Jun, Sang-Ho;Ahn, Jin-Soo;Ryu, Jae-Jun;Kwon, Jong-Jin
    • The Journal of the Korean dental association
    • /
    • v.51 no.4
    • /
    • pp.190-197
    • /
    • 2013
  • A titanium based screw shaped dental implant was first introduced by Branemark and a treatment protocol where the restoration of edentulous area by connecting abutment after the osseointegration of the titanium surface of the implant and surrounding bone structure has been proposed. Although this protocol is widely accepted as a standard up to date, the healing duration of 3-6 months as well as the need for provisional prostheses during this period present as a major drawback. Immediate loading has been accomplished through the advent of various implant designs, enforced surface treatments, diverse forms of abutment, and delicate surgical techniques together with the increase in demand from the patients. The success rate of the immediate loading technique has been first reported as 85.7% by Dr. Schnitman in 1990 which recently has been reported up to 100% in the case of immediate loading in single tooth by Dr. Kan. To ameliorate the success rate of immediate loading technique, selection of patients presenting a sound bone quality and quantity, acquiring primary stability through delicate surgical techniques and fabrication of prostheses which accounts for biological stabilities should all be taken into consideration. This presentation introduces the understanding of biological stability of immediate loading, various methods for measurement of stability and clinical cases regarding immediate loading technique.

Implant-Supported Fixed Prostheses for the rehabilitation of distal free end in periodontally compromised dentitions Number of fixtures affecting bone tissue change (치주질환에 이환된 환자에서 구치 상실 치열 수복을 위한 임플란트 수복)

  • Yi, Seung-Won;Kim, Young-Soo
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.53-63
    • /
    • 2005
  • Number of fixtures supporting prosthesis for rehabilitation of partial edentulism in distal area is an important factor in distal area to the bone tissue response around dental implant. Optimal number and optimal positioning of dental implant has leaded to the stable condition of bone tissue and successful long-term treatment outcome. This clinical and radiographic study was performed to document and evaluate the short-term result of occlusal rehabilitation by means of implant-supported fixed prostheses (ISPs) especially for partial edentulism in distal area in patients treated for advanced periodontal disease and to verify the number of fixture affecting the bone tissue response. A total of 30 consecutive patients referred because of advanced periodontal disease were included. Before the implant therapy was initiated, periodontal treatment was performed and the outcome evaluated during at least a 6-month period. An individual maintenance care program was designed for each patient. All 75 implants were placed using a 2-stage surgical approach. The patients were divided into 2 groups, in one of which two fixtures were placed and in the other of which three fixtures were placed with tripodal geometry. Following installation of the ISPs, all patients underwent a baseline examination including evaluation of i) oral hygiene, and ii) periodontal/ peri-implant conditions, and iii) radiographs. These examinations were repeated annually during the 1 or 2-year observation period. The results were as follows: 1.No single implant was lost during the observation follow-up period. 1.The percentage of plaque harboring surfaces and bleeding units upon probing were found to be low (<10%), and no soft tissue complications were recorded. 1.Two-fixture group showed bone destruction ranged from 0.0mm to 1.5mm and the mean was 0.31mm. Three-fixture group showed more bone destruction of 0.51mm. There was no statistically difference between two groups. These results suggested that the factor for success is not the number of fixture but the strict maintenance of peri-implant tissue health and initial stability of fixture.

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Application and consideration of digital technology for removable complete denture (총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰)

  • Lee, Jung-Jin;Song, Kwang-Yeob;Park, Ju-Mi
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

Axial displacement in single-tooth implant restoration: Case report (임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고)

  • Jeong, Seung-Hoe;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.126-133
    • /
    • 2021
  • Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.