• 제목/요약/키워드: Dental images

검색결과 807건 처리시간 0.023초

The effectiveness of optical coherence tomography for evaluating peri-implant tissue: A pilot study

  • Sanda, Minoru;Shiota, Makoto;Imakita, Chiharu;Sakuyama, Aoi;Kasugai, Shohei;Sumi, Yasunori
    • Imaging Science in Dentistry
    • /
    • 제46권3호
    • /
    • pp.173-178
    • /
    • 2016
  • Purpose: Optical coherence tomography (OCT) has been investigated as a novel diagnostic imaging tool. The utilisation of this equipment has been evaluated through several studies in the field of dentistry. The aim of this preliminary study was to determine through basic experiments the effectiveness of OCT in implant dentistry. Materials and Methods: To assess detection ability, we captured OCT images of implants in each of the following situations: (1) implants covered with mucosae of various thicknesses that were harvested from the mandibles of pigs; (2) implants installed in the mandibles of pigs; and (3) implants with abutments and crowns fixed with temporary cement. The OCT images were captured before cementation, after cementation, and after removing the excess submucosal cement. Results: If the thickness of the mucosa covering the implant body was less than 1 mm, the images of the implants were clearly detected by OCT. In the implants were installed in pigs' mandibles, it was difficult to capture clear images of the implant and alveolar bone in most of the samples. Remnants of excess cement around the implants were visible in most samples that had a mucosa thickness of less than 3 mm. Conclusion: Currently, OCT imaging of implants is limited. Cement remnants at the submucosal area can be detected in some cases, which can be helpful in preventing peri-implant diseases. Still, though there are some restrictions to its application, OCT could have potential as an effective diagnostic instrument in the field of implant dentistry as well.

디지털공제프로그램간의 디지털공제영상 비교 (A comparison of subtracted images from dental subtraction programs)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

Can ultra-low-dose computed tomography reliably diagnose and classify maxillofacial fractures in the clinical routine?

  • Gerlig Widmann;Marcel Dangl;Elisa Lutz;Bernhard Fleckenstein;Vincent Offermanns;Eva-Maria Gassner;Wolfgang Puelacher;Lukas Salbrechter
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: Maxillofacial trauma predominantly affects young adults between 20 and 40 years of age. Although radioprotection is a legal requirement, the significant potential of dose reduction in computed tomography (CT) is still underused in the clinical routine. The objective of this study was to evaluate whether maxillofacial fractures can be reliably detected and classified using ultra-low-dose CT. Materials and Methods: CT images of 123 clinical cases with maxillofacial fractures were classified by two readers using the AOCOIAC software and compared with the corresponding results from post-treatment images. In group 1, consisting of 97 patients with isolated facial trauma, pre-treatment CT images at different dose levels (volumetric computed tomography dose index: ultra-low dose, 2.6 mGy; low dose, <10 mGy; and regular dose, <20 mGy) were compared with post-treatment cone-beam computed tomography (CBCT). In group 2, consisting of 31 patients with complex midface fractures, pre-treatment shock room CT images were compared with post-treatment CT at different dose levels or CBCT. All images were presented in random order and classified by 2 readers blinded to the clinical results. All cases with an unequal classification were re-evaluated. Results: In both groups, ultra-low-dose CT had no clinically relevant effect on fracture classification. Fourteen cases in group 2 showed minor differences in the classification code, which were no longer obvious after comparing the images directly to each other. Conclusion: Ultra-low-dose CT images allowed the correct diagnosis and classification of maxillofacial fractures. These results might lead to a substantial reconsideration of current reference dose levels.

Case series of cleidocranial dysplasia: Radiographic follow-up study of delayed eruption of impacted permanent teeth

  • Yeom, Han-Gyeol;Park, Won-Jong;Choi, Eun Joo;Kang, Kyung-Hwa;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.307-315
    • /
    • 2019
  • This report describes 3 cases of cleidocranial dysplasia (CCD) and presents relevant findings on long-term follow-up radiographic images of impacted permanent teeth with delayed eruption. Radiographic images of 3 CCD patients were reviewed retrospectively. These images were mainly composed of panoramic and skull radiographs, and the follow-up periods were 3, 13, and 13 years, respectively. The distinct features revealed by the images were described, and the eruption state of impacted permanent teeth was evaluated. The features common to the 3 cases were multiple supernumerary teeth, the presence of Wormian bone, underdevelopment of the maxilla and the maxillary sinus, and clavicular hypoplasia. The eruption of impacted permanent teeth was not observed without proper dental treatment in adult CCD cases, even after long time periods had elapsed. When proper orthodontic force was applied, tooth movement was observed in a manner not significantly different from the general population.

Augmented Reality Technology-based Dental Radiography Simulator for Preclinical Training and Education on Dental Anatomy

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of information and communication convergence engineering
    • /
    • 제17권4호
    • /
    • pp.274-278
    • /
    • 2019
  • It is important that students are provided opportunities to practice their skills in acquiring radiographic images. However, these opportunities are currently limited because of the risk of radiation exposure. To overcome this limitation, a new augmented reality-based radiography simulator was developed that enables students to practice radiographic techniques as part of self-directed learning without time and space constraints. Subsequently, cross-sectional images of a manikin phantom head obtained via computed tomography were reconstructed into a three-dimensional object. An image marker that could be recognized by a mobile device and could allow users to practice dental radiography techniques was devised. The three-dimensional object was augmented to the mobile device; consequently, among 106 stored dental radiographs on the device, a radiograph corresponding to specific imaging conditions was opened when users performed radiographic procedures. This technology could improve dental students' understanding of dental anatomy and contribute to improving their competency in acquiring dental radiographs.

저작근극에서 발생한 전이된 갑상선 여포상암 (Metastatic thyroid follicular carcinoma of masticator space)

  • 강태인;허민석;안창현;최미;이삼선;최순철;박태원
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.175-179
    • /
    • 2002
  • Follicular carcinomas are the second most common form of thyroid cancer, accounting for 10 to 20% of all thyroid cancers. Follicular carcinomas have a propensity to metastasize via the bloodstream, spreading to bone, lungs, liver, and elsewhere. We described the case of a 48-year-old woman who presented with swelling of the left preauricular area, which was a consequence of a metastatic follicular carcinoma of the masticator space. Plain films showed illdefined erosive bony changes from the left condylar head to the mandibular notch. Contrast-enhanced CT images showed a well circumscribed round mass with well enhancement within left masticator space. On MR images, the mass was heterogenously hyperintense to the muscle on T2-weighted images and isointense or hyperintense to the muscle on Tl-weighted images, and showed good enhancement on contrast-enhanced Tl-weighted images. Upon microscopic examination, the metastatic mass was found to be composed of fairly uniform cells forming small follicles containing colloid, showing capsular and vascular invasion.

  • PDF

영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향 (Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

인접면 치아우식 진단을 위한 디지털 방사선 조영 공제술 (Digital contrast subtraction radiography for proximal caries diagnosis)

  • 강병철;윤숙자
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.123-127
    • /
    • 2002
  • Purpose : To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Materials and Methods: Thirty-six teeth with 57 proximal surfaces were radiographied using a size #2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. Results: The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. Conclusion: The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  • PDF

치아 윤곽선 정보를 이용한 신경회로망 기반 신원 확인 방안 (Neural Network-Based Human Identification Using Teeth Contours)

  • 박상진;박형준
    • 한국CDE학회논문집
    • /
    • 제18권4호
    • /
    • pp.275-282
    • /
    • 2013
  • This paper proposes a method for human identification using teeth contours extracted from dental images that are captured from the frontal views of subjects each of who opens his or her mouth slightly. Each dental image has a black-colored region containing the subject's teeth contours which are usually different from subject to subject. This means that this black-colored region has bio-mimetic information useful for human identification. The basic idea of the method is to extract the upper and lower teeth contours from the dental image of each subject and to encode their geometric patterns using a back-propagation neural network model. After acquiring 400 teeth images form 10 university students, we used 300 images for the training data of the neural network model and 100 images for its verification. Experimental results have shown that the proposed neural network-based method can be used as an alternative solution for identification among a small group of humans with a low cost and simple setup.