• 제목/요약/키워드: Dental gold alloy

검색결과 105건 처리시간 0.027초

보성치과주조용 금합금의 물리적성상과 부식 및 변색에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON PHYSICAL PROPERTIES, TARNISH AND CORROSION RESISTANCE OF BO-SUNG DENTAL GOLD ALLOY)

  • 김인철;박윤삼
    • 대한치과의사협회지
    • /
    • 제13권11호
    • /
    • pp.1021-1024
    • /
    • 1975
  • Bo-sung dental gold alloy was tested an physical properties, tarnish and corrosion restistance. The results were as follows : 1. No differences beween physical properties of Bo-Sung dental gold alloy and American Dental Association Specification No. 5. 2. Tarnish and Corrosion resistance of Bo-Sung dental gold alloy were favorable of dental uses. 3. Bo-Sung dental gold alloys showed equiaxed grain structure in microstructures.

  • PDF

치과용 금합금-보철물의 마찰특성 (Friction of the Gold-Alloy Dental Prosthesis)

  • 최원식
    • Tribology and Lubricants
    • /
    • 제24권1호
    • /
    • pp.44-48
    • /
    • 2008
  • The wear characteristics of the gold alloy dental prosthesis have been investigated. The wear tests were performed by using a pin-on-disk wear tester at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by microscope. The friction coefficient of the gold alloy dental prosthesis was investigated according to weight and slinging velocity. The hardness of the gold alloy dental prosthesis were similar and a half of the enamel of natural teeth.

금합금의 특수성질 및 성분에 관한 연구 (A Study on Specific Qualities of Gold Alloy and its Components)

  • 신무학
    • 대한치과기공학회지
    • /
    • 제2권1호
    • /
    • pp.11-15
    • /
    • 1980
  • This study was aimed at obtaining an ideal gold alloy for dental prothetic. The experiment was on physical characteristics of gold alloy and mixing proportion for proper appliance to living tissues. The most frequently used material in the past for dental prothetic was gold, but recently used are mictures or precious metals and non-precious, which are proved to affect on oral tissues. The experiment was to examine gold alloy over its physical and chemical qualities and to make an ideal type of gold alloy by means of statistic and laboratory research.

  • PDF

도재소부용 고금함유금합금의 연구 - 도재 결합층을 중심으로 - (A Study on Metal-Porcelain Fusing Layer in Porcelain Fused to High Gold Alloy)

  • 이기대;곽동주
    • 대한치과기공학회지
    • /
    • 제31권3호
    • /
    • pp.15-20
    • /
    • 2009
  • The success of the porcelain fused to gold alloy restoration depends not only on the choice of materials but to a larger degree on the technical skills. The porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory. The gold-colored alloys contain primarily gold, platinum, palladium, and silver, with minimum amounts of such metals as tin, iridium, or titanium. The purpose of this study is on the metal-porcelain fusing layer in porcelain fused to high gold alloy Principal results are as follows. The hardness number(Hv) of PFG is respectively $140.2{\pm}12.6$ in as-casted, $164.3{\pm}14.3$ in heat-treated, $186.6{\pm}20.4$ in fired-treated. The formation of the fusing(intermediate) layer caused by components fusing the interface of porcelain and gold alloy. The main components of the fusing(intermediate) layer are Na, Al, Si, K, Zn, Zr and Ce. The intermediate layer formed by the 2nd firing is more larger than the intermediate layer formed by the 1st firing.

  • PDF

보성치과주조용합금의 생체반응에 관한 실험적연구

  • 김인철
    • 대한치과의사협회지
    • /
    • 제14권5호
    • /
    • pp.425-427
    • /
    • 1976
  • The author observed the reaction of gingval tissues which were implanted with gold, Bosung alloy and copper, the constituents of gold alloy. Pure gold and bosung alloy strips produced slight inflammation but copper had sovere inflammation. Dense fibrous fascile were formed around the gold and Bosung alloy strips on 7th day. When gold and Bosung alloy strips were implanted, eptithelial memberane were occured on 14th day, but copper strips produced eplthelial memberane on 21th day.

  • PDF

도재소부용 18K 금합금의 미량원소의 첨가에 따른 물리적 성질의 변화에 관한 연구 (A Study on Change of Physical Property in Porcelain Fused to 18K Gold Alloy by Small Additional Elements)

  • 이기대
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.31-37
    • /
    • 2008
  • A variety of the porcelain fused to gold(PFG) have been developed to which porcelain can be fused. PFG alloys developed for this purposed have a high melting point and do not discolor when combined with porcelain. The design of the compositions of PFG is very important to esthetic restorative materials applying to porcelain. The purpose of this study is on the change of physical and mechanical characteristics in PFG 18K alloy by the small additional elements. Principal results are as follows. The high Au alloy containing 18Karat gold contents is respectively Au(75%), Pd(10%), Pt(4%), Ag(4%), In(2%), Sn(2%), Cu(2%), Ti(1%). These alloys are composed mainly of gold, platinum, silver and palladium with a few percent of the additional elements. By the addition of small amounts of elements such as In, Sn, Ti, the fine grain castings are produced in gold alloy and the small addition of platinum is very effective in increasing of hardness and strength. These gold alloys are representative of the changes to be expected as a result of heat treatment. These changes in strength and hardness values are sufficient to demonstrate a significant difference in performance between a as-casted and a heat-treated. These alloys have mechanical properties characteristics of Type and Type gold alloys. These alloys are useful to porcelain-metal restorations and dental laboratory. Also the porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory.

  • PDF

금합금 연마재 종류에 따른 금합금 소실량과 연마 정도 (THE AMOUT OF LOSS AND THE DEGREE OF SURFACE SMOOTHNESS OF GOLD ALLOY BY GOLD ALLOY POLISHING RUBBER POINT MATERIALS)

  • 김명화;임순호;정문규
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.277-295
    • /
    • 1997
  • After clinical adjustment of dental casting restoration, re-polishing procedure is recommanded because the smooth gold sureface is lost. But there is the possibility to get more loose contact than that intended by loss of gold alloy according to the kinds of polishing materials and polishing time. Therefore in this study I polished type II gold alloy with 390gm force, 20,000rpm speed, and 8 kinds of gold alloy polishing materials, fabricated by 4 companies and then measured the amount of loss of gold alloy with Surfcorder SEF-30D and observed alloy surfaces polished by 3 brown rubber points with SEM. The amount of loss of gold alloys polished with 8 kinds of polishing materials and the degree of smoothness of gold alloys according to polishing time and polishing materials were compared. The following results were obtained : 1. When the amount of loss of gold alloys polished with 3 kinds of brown rubber point was compared, Alphalex brown point had the most amount of alloy loss, followed in decreasing order by Shofu brown point and Eveflex brown point. There was statistically significant difference in the amount of alloy loss according to polishing materials. 2. When the amount of loss of gold alloys polished with 5 kinds of green rubber point was compared, Shofu green point had the most amount of alloy loss, followed in decreasing order by Alphaflex green point, Dedeco green clasp polisher, and Eveflex green point. There was statistically significant difference in the amount of alloy loss according to polishing materials except Alphaflex green point and Dedeco green clasp polisher. 3. When the amount of loss of gold alloys polished with all kinds of rubber point was compared, there was no significant difference in Eveflex brown point, Alphaflex green point, and Dedeco green clasp polisher. 4. When average amount of alloy loss per 1 revolution by polishing materials was compared, Alphalex brown point had the greatest value as $0.329{\mu}m$ and Shofu supergreen point had the lowest value as $0.022{\mu}m$. 5. When the degree of sureface smoothness of gold alloy polished with 3 kinds of brown rubber point was compared, In Alphalex brown point surface roughness was completely lost after 20 seconds polishing time, in Shofu brown point 30 seconds, in Eveflex brown point 40 seconds. But in every gold alloys fine scratch formed by rubber points was observed. Based on the results of this study, as rubber polishing materials used in polishing of dental casting restoration after clinical adjustment influenced on the tightness of occlusal or proximal contact, we should make dental casting restoration with minimum error through careful laboratory procedure and form very smooth surface of restoration with tripoli and rouge after use of silicone polishing materials.

  • PDF

강화형 복합레진과 수종의 치과용 합금간의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of the Reinforced Composite Resin to Dental Alloys)

  • 김정희;조인호
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.113-122
    • /
    • 2000
  • The reinforced composte resin as the esthetic operative material continuously has been studied because the porcelain fused metal prosthesis is widely used for its excellent esthetics, rigidity and marginal integrity, but it has low fracture resistance against the tensile strength and stress, attrition of the opposite teeth. The reinforced composite resin is well adapt with the dental alloy but it is low the shear bond strength with the dental alloy vs the porcelain fused metal prosthesis, and then has been studied continuously. The purpose of the study was to examine how metal was the higher shear bond strength among the dental alloy was used to the reinforced composite resin and to find the effect that the particle size of sandblasting influenced the shear bond strength. We built up the reinforced composite resin with 4 mm in diameter, 3 mm in height on circular alloy with 5 mm in diameter, 2 mm in height. Type II gold, type IV gold, and Ag-Pd alloy was used as alloys and $50{\mu}m$, $110{\mu}m$, $250{\mu}m$ of the particle size was sandblasted at each alloy in bonding between alloy and resin. We made 90 secimens of 10 per each group and we measured the shear bond strength using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The obtained results were as follows : 1. In comparison among each alloys, Ag-Pd alloy had the highest shear bond strength and the shear bond strength was decreased significantly in the sequence of the type II gold and type IV gold(P<0.001). 2. In comparison according to the size of sandblasting particle, (1) In Ag-Pd alloy, shear bond strength was decreased in the sequence of $110{\mu}m$, $250{\mu}m$, $50{\mu}m$ and there were significant difference in all the group. (P<0.05) (2) In type II gold, it was decreased in the sequence of $250{\mu}m$, $50{\mu}m$, $110{\mu}m$ and there were significant difference. (P<0.05) (3) In type IV gold, it was decreased in the sequence of $110{\mu}m$, $50{\mu}m$, $250{\mu}m$. There were significant difference between the group of $110{\mu}m$ and $50{\mu}m$, the group of $110{\mu}m$ and 250, but there were no significant difference in the group of $50{\mu}m$ and $250{\mu}m$. 3. The highest shear bond strength according to the size of sandblasting particle was $110{\mu}m$ in Ag-Pd alloy and type IV gold, $250{\mu}m$ in type II gold.

  • PDF

치아에 잔존하는 치과재료의 성분분석을 통한 개인식별에의 응용 (Analysis of Residual Dental Materials Existing on the Teeth and Its Application to Individual Identification)

  • 윤중교;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.193-209
    • /
    • 1998
  • In identifying bodies that are severely decayed or damaged, methods using fingerprints and various biochemical tests are known to have its limits. To overcome this, forensic odontological method which is based on the analysis of the cranium, tooth and dental restoration is used to enhance the accuracey of individual identification. For this reason, I have come to analysis of the dental materials that exists between the teeth that is perceived to have been previously restored and the one adjacent to it. By analyzing the constituents of gold crown-restored, non-precious metal-restored, gold inlay-restored and amalgam -restored teeth, and adjacent teeth using EDX(energy dispersive X-ray microanalysis) which was invented to analyze very small amount of elements, the nature of the restoration could be predicted and the results obtained were as follows. 1. Some of constitute of gold alloy was extracted from residual cement of gold crown restoration, but that was not extracted from the restored tooth and the one adjacent to it. 2. Some of constituents of non-precious metal alloy was extracted both in the residual cement on the tooth with no-precious metal restoration and in the tooth with the restoration itself. However, none of its constituents were found in the tooth adjacent to it. 3. Some of constituents of gold alloy were found in the residual cement of gold inlay, but they were not found in the restored tooth and the adjacent tooth. 4. Some of constituents of amalgam alloy were found both in tooth restored with amalgam and in the adjacent tooth. From the results obtained above, it is possible to utilize the data obtained from analyizing residual dental materials in a more effective way. This data compensates for the lost data due to any harm done to the restorations prior to individual identification and further enhances the accuracy. Therefore, it could be concluded that this process of analyzing residual dental materials could be beneficial to individual identification in the area of forensic odontoldogy.

  • PDF

Ni-Cr합금과 도재간의 결합력에 gold-based bonding agent가 미치는 영향 (The effect of the gold based bonding agents on the bond between Ni-Cr alloys and ceramic restorations)

  • 이정환;주규지
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.213-223
    • /
    • 2007
  • The success of a porcelain fused to metal (PFM) restoration depends upon the quality of the porcelain-metal bond. The adhesion between metal substructure and dental porcelain is related to the diffusion of oxygen to the reaction layer formed on cast-metal surface during firing. The purposed of this investigation was to study the effects of gold based bonding agent on Ni-Cr alloy-ceramic adhesion between porcelain matrix, gold based bonding agent and metal substructure interface. gold based bonding agent have been applied as an intermediate layer between a metal substructure and a ceramic coating. gold based bonding agent(Aurofilm NP, Metalor, Swiss) was applied on Ni-Cr alloy surface by four method. Surfaces only air abraded with 110${\beta}\neq$ Al2O3 particles were used as control. metal ceramic adhesion was evaluated by a biaxial flexure test(N=5) and volume fraction of adherent porcelain was determined by SEM/EDS analysis. Result of this study suggest that the layering sequence of gold based bonding agent is very important and can improve porcelain adherence to PFM.

  • PDF