• Title/Summary/Keyword: Dental etching

Search Result 148, Processing Time 0.028 seconds

Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

  • Khoroushi, Maryam;Ehteshami, Ailin
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.83-90
    • /
    • 2016
  • Objectives: This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etchand-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=0.05$). Results: The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. Conclusions: Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

EFFECTS OF SURFACE TREATMENT AND BONDING AGENTS ON SHEAR BOND STRENGTH OF THE COMPOSITE RESION TO IPS-EMPRESS CERAMIC (IPS-Empress 도재에 대한 콤포짓트 레진의 전단결합강도)

  • Yoon, Byeung-Sik;Im, Mi-Kyung;Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.413-423
    • /
    • 1998
  • Dental ceramics exhibit excellent esthetic property, compressive strength, chemical durability, biocompatibility and translucency. This study evaluated the shear bond strength of composite resin to the new heat-pressed ceramic material (IPS-Empress System) depending on the surface treatments and bonding agents. The surface treatments were etching with 4.0% hydrofluoric acid, application of silane, and the combination of the two methods. Composite resin was bonded to ceramic with four kinds of dentin bonding agents(All-Bond 2, Heliobond, Scotch bond Multi-purpose and Tenure bonding agents). The ceramic specimen bonded with composite resin was mounted in the testing jig, and the universal testing machine(Zwick 020, Germany) was used to measure the shear bond strength with the cross head speed of 0.5 mm/min. The results obtained were as follows 1. The mean shear bond strength of the specimens of which the ceramic surface was treated with the combination of hydrofluoric acid and silane before bonding composite resin was significantly higher than those of the other surface treatment groups(p<0.05). 2. In the case of All-Bond 2 and Scotchbond Multi-purpose bonding agent group, the surface treatment methods did not influenced significantly on the shear bond(p>0.05). 3. Of the four bonding agents tested, the shear bond strength of Heliobond was significantly lower than those of other bonding agents regardless of the surface treatment methods(p<0.05). 4. The highest shear bond strength($12.55{\pm}1.92$ MPa) was obtained with Scotchbond Multipurpose preceded by the ceramic surface treatment with the combination of 4% hydrofluoric acid and silane.

  • PDF

A CAD/CAM-based strategy for concurrent endodontic and restorative treatment

  • Escobar, Patricia Maria;Kishen, Anil;Lopes, Fabiane Carneiro;Borges, Caroline Cristina;Kegler, Eugenio Gabriel;Sousa-Neto, Manoel Damiao
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.27.1-27.12
    • /
    • 2019
  • This case report describes a technique in which endodontic treatment and permanent indirect restoration were completed in the same clinical appointment with the aid of a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Two patients were diagnosed with irreversible pulpitis of the mandibular first molar. After access preparation, root canals were located, irrigation was performed until bleeding ceased, and the coronal tooth structure was prepared for indirect restoration. Then, utilizing an interim 3-mm build-up of the endodontic access cavity, a hemi-arch digital scan was performed with an intraoral scanner. Subsequent to digital scanning, restoration design was performed simultaneously with the endodontic procedure. The root canals were shaped using the Race system under irrigation with 2.5% sodium hypochlorite followed by root canal filling. The pulp chamber was subsequently filled with a 3-mm-thick composite resin restoration mimicking the interim build-up previously utilized to facilitate block milling in the CAD/CAM system. Clinical try-in of the permanent onlay restoration was followed by acid etching, application of a 5th generation adhesive, and cementation of the indirect restoration. Once the restoration was cemented, rubber dam isolation was removed, followed by occlusal adjustment and polishing. After 2 years of follow-up, the restorations were esthetically and functionally satisfactory, without complications.

Bone healing dynamics associated with 3 implants with different surfaces: histologic and histomorphometric analyses in dogs

  • Lee, Jungwon;Yoo, Jung Min;Amara, Heithem Ben;Lee, Yong-Moo;Lim, Young-Jun;Kim, Haeyoung;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.1
    • /
    • pp.25-38
    • /
    • 2019
  • Purpose: This study evaluated differences in bone healing and remodeling among 3 implants with different surfaces: sandblasting and large-grit acid etching (SLA; IS-III $Active^{(R)}$), SLA with hydroxyapatite nanocoating (IS-III $Bioactive^{(R)}$), and SLA stored in sodium chloride solution ($SLActive^{(R)}$). Methods: The mandibular second, third, and fourth premolars of 9 dogs were extracted. After 4 weeks, 9 dogs with edentulous alveolar ridges underwent surgical placement of 3 implants bilaterally and were allowed to heal for 2, 4, or 12 weeks. Histologic and histomorphometric analyses were performed on 54 stained slides based on the following parameters: vertical marginal bone loss at the buccal and lingual aspects of the implant (b-MBL and l-MBL, respectively), mineralized bone-to-implant contact (mBIC), osteoid-to-implant contact (OIC), total bone-to-implant contact (tBIC), mineralized bone area fraction occupied (mBAFO), osteoid area fraction occupied (OAFO), and total bone area fraction occupied (tBAFO) in the threads of the region of interest. Two-way analysis of variance (3 types of implant $surface{\times}3$ healing time periods) and additional analyses for simple effects were performed. Results: Statistically significant differences were observed across the implant surfaces for OIC, mBIC, tBIC, OAFO, and tBAFO. Statistically significant differences were observed over time for l-MBL, mBIC, tBIC, mBAFO, and tBAFO. In addition, an interaction effect between the implant surface and the healing time period was observed for mBIC, tBIC, and mBAFO. Conclusions: Our results suggest that implant surface wettability facilitates bone healing dynamics, which could be attributed to the improvement of early osseointegration. In addition, osteoblasts might become more activated with the use of HA-coated surface implants than with hydrophobic surface implants in the remodeling phase.

Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs

  • Kwon, Yee-Seo;Namgoong, Hee;Kim, Jung-Hoon;Cho, In Hee;Kim, Myung Duk;Eom, Tae Gwan;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.1
    • /
    • pp.41-46
    • /
    • 2013
  • Purpose: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). Methods: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3 types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The $P_1-M_1$ teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. Results: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants, but there was no significant difference between 4 and 8 weeks. Conclusions: The existence of microthreads was not a significant factor in mechanical and histological stability.

Comparative scanning electron microscope analysis of the enamel of permanent human, bovine and porcine teeth

  • Olek, Aneta;Klimek, Leszek;Boltacz-Rzepkowska, Elzbieta
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.83.1-83.14
    • /
    • 2020
  • Background: Bovine and porcine teeth are often used in in vitro experiments as substitutes of human teeth. Objectives: The aim of the present study was to perform a comparative analysis of enamel morphology of permanent human, bovine and porcine teeth under the scanning electron microscope. Methods: As many as 10 human, 10 bovine, and 10 porcine teeth were studied. All the teeth were sectioned and the halves were randomly divided into 2 groups according to the examined tissue (vestibular enamel at the mid-height of the dental crown and in the cervical area). Human and bovine enamel was etched for 15 sec and porcine enamel for 30 sec. The scanning electron microscope analysis was performed. The length and width of enamel prisms were determined with the "Met-Ilo" 1.1 computer program. Results: All enamel samples revealed the same etching pattern-Silverstone's type 2. Bovine enamel showed a similar porosity and the amount of interprismatic enamel compared to human enamel while the amount and width of interprismatic enamel bands in porcine enamel were evidently greater. The shape of the porcine prisms was visually similar to human prisms, although dimensions were significantly different. However, bovine prisms differed in form and appeared to be distinctly elongated. Conclusions: Reported findings indicate that the results of experimental studies carried out on bovine and porcine enamel should not be compared with the results obtained on human enamel.

A SCANNING ELECTRON MICROSCOPIC STUDY OF BONDING ASPECTS TO THE SCLEROTIC DENTIN (경화된 상아질의 접합 양상에 관한 주사전자현미경적 연구)

  • Lee, Rin;Lee, Hyeong-Il;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.228-243
    • /
    • 1997
  • The changes of microstructures, morphology of sclerotic dentin and bonding aspects generated by an adhesive resin was investigated. Incisors and premolars showing natural cervical abrasions were collected and conditioned with 10 % phosphoric acid or 10 % maleic acid. The sclerotic dentin specimens were then rinsed and blot-dried and applied with dentin adhesive (All Bond 2) to the conditioned dentin surface. To examine the morphologic change of the sclerotic dentin specimen after etching and bonding procedure, the treated specimens were examined by SEM. To analyze the chemical composition of sclerotic dentin and crystals occluding dentinal tubules, the sclerotic dentin specimen was powdered and examined with X-ray Diffractometer. To investigate the Ca/P weight percent ratio within the dentinal tubules, the sclerotic dentin specimen was fractured perpendicularly to the long axis of the tooth from the center of cervical abrasion lesion and then examined with EDX(Energy Dispersive X-ray) microanalyzer. The results were as follows : 1. The increased width of peritubular dentin and the depositions of the irregular amorphous materials within the dentinal tubules were showed in the sclerotic dentin specimens. 2. After the treatment of sclerotic dentin specimen with 10 % phosphoric acid or 10 % maleic acid, the lateral side of tubules rather than cross-sectional tubule openings was showed exclusively at the incisal and gingival incline of the specimens. 3. After the treatment of sclerotic dentin specimen with 10 % phosphoric acid or 10 % maleic acid, the hybrid layer was not formed evidently and the resin tag was not formed or shortly penetrated into the tubules with the thinner diameter. 4. According to the results of XRD analysis of the sclerotic dentin specimen, Hydroxyapatite and Octacalcium phosphate were predominent, however, Whitlockite crystals were rare. 5. The mean Ca/P weight percent ratio analysed from 5 fractured sclerotic dentin specimens was $2.322{\pm}0.170$ at the intertubular dentin, $1.826{\pm}0.051$ within the dentinal tubule.

  • PDF

SHEAR BOND STRENGTH OF COMPOSITE RESIN TO ENAMEL FOLLOWING ENAMEL MICROABRASION (Enamel Microabrasion을 시행한 법랑질과 복합레진의 전단결합강도)

  • Hong, Kee-Sang;Lee, Sang-Dae;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • Enamel microabrasion is a means by which superficial enamel discoloration is removed using hydrochloric acid and fine pumice. As enamel microabrasion alone may not be sufficient in cases of deeper discoloration, composite resin restoration is recommended in areas where there is remaining discoloration. The purpose of this study was to investigate the effects of different methods and number of applications of enamel microabrasion on the shear bond strength of composite resin to enamel. Untreated control was designated as group 1. 5-second applications of a mixture of 18% HCl and fine pumice were performed 5 and 10 times on groups 2 and 3, respectively. A commercially available mixture of 10% HCl and abrasives(PREMA) was applied using a 10 : 1 gear reduction handpiece 5 and 10 times on groups 4 and 5, respectively, with each application lasting 20 seconds. After etching with 37% phosphoric acid, composite resin was bonded. Thermocycling was performed and shear bond strength was measured. The following results were obtained : 1. Group 2 showed the highest bond strength$(24.36{\pm}3.34)$, while group 3 showed the lowest$(19.35{\pm}3.43)$, Shear bond strength decreased in the following order: 2>4>5>1>3. 2. Group 2 showed bond strength significantly higher compared to groups 1 and 3(p<0.05). 3. There were no significant differences between groups 2 and 3, which had been microabraded using HCl and pumice, and groups 4 and 5, to which PREMA had been applied, when bond strengths were compared(p>0.05). 4. When modes of fracture were examined, adhesive failure was observed in groups 3 and 4, while cohesive failure was observed in groups 1, 2, 3 and 4. Only mixed failures were found group 5. 5. When viewed using a SEM, groups 2 and 3, which had been microabraded using HCl and pumice, showed surface appearances similar to that of enamel etched with phosphoric acid. Groups 4 and 5, treated with PREMA, exhibited a smooth surface similar to that of group 1. All oops showed similar, typical surface characteristics following phosphoric acid etching.

  • PDF

The effects of a sealant resin on enamel demineralization in orthodontic bracket bonding (브라켓 부착 시 실런트 레진이 법랑질 탈회에 미치는 영향)

  • Youn, Young-An;Cho, Jin-Hyoung;Lee, Ki-Heon
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.43-50
    • /
    • 2005
  • The purpose of this study was to evaluate the effects of a sealant resin on enamel demineralization In orthodontic bracket bonding. The forty eight extracted sound bovine teeth were subdivided into four groups and treated with Phase II (Reliance, itasca. III) on the surface Group 1 was not treated. Group 2 was acid etched with 37% phosphoric acid for 30 seconds. Group 3 was applied with sealant after acid etching. Group 4 was applied with resin paste after acid etching and sealant application. Each group was demineralized in artificial caries solution. Demineralized enamel depth was measured by confocal laser scanning microscopy. The results were as follows: the mean demineralized enamel depth was $47.4{\mu}m$. (Group 1), $61.8{\mu}m$ (Group 2), $13.9{\mu}m$ (Group 3). $8.2{\mu}m$ (Group 4) the demineralized enamel depth was increased in Group 2 than in Group 1 (p<0.05); the demineralized enamel depth was reduced in Group 3 than in Group 1 and Group 2 with statistically significant differences (p<0.05): and demineralization in Group 4 was very little. The results of the present study indicate that sealant application is useful for reducing enamel demineralization in orthodontic bracket bonding.

The Effect of Titaniuml Surface Treatment on Osteoblast-Like Cell Attachment and Proliferation (Titanium 표면처리 방법이 Osteoblast-like Cells의부착 및 증식에 미치는 영향)

  • Kim, Do-Yung;Seol, Yang-Jo;Rhyu, In-Cheul;Hahm, Byung-Do;Chung, Chong-Pyoung;Choi, Sang-Mook;Kim, Woo-Jin;Baik, Hong-Koo;Heo, Seong-Joo;Han, Chong-Hyun;Kim, Myung-Ho;Choi, Yong-Chang;Chun, Heoung-Jae;Kwon, Soo-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.491-504
    • /
    • 2000
  • In clinical therapy, the current goal of dental implants is to enhance quantity and quality of osseointegration. Surface roughness and oxide structure are considered to influence the behavior of adherent cells. The purpose of this study is to evaluate the effect of different surface treatment on cellular response. The attachment and proliferation of osteoblast-like cell on sandblasted, sandblasted and etched, thermal oxidated surfaces have been compared. Sandblasting was done with $Al_2O_3$ particles(grain size of $50{\mu}m$), etching was processed with $NH_4OH$ : $H_2O_2$ : $H_2O(1:1:5)$ at $90^{\circ}C$ for 1 minute. Thermal oxidation was followed sandblasting and etching at $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$ for 2 hours. Measurement of surface roughness after the different treatment did not show any differences of Ra value between terated surfaces. Cell attachment and proliferation were increased during experiment period, but no difference was observed. SEM evaluation revealed a similar pattern of osteoblast-like cells, well attached with dendritic extension and producing numerous matrix vesicles on cell surface. The results of this study showed that oxide layer alteration by thermal oxidation did not affect the attachment and proliferation of osteoblast-like cells. This suggests the possibility that the cellular responses are further influenced by surface roughness than titaniun oxide structure.

  • PDF