• 제목/요약/키워드: Dental digital impression

검색결과 97건 처리시간 0.021초

Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques

  • Kocaagaoglu, Hasan;Albayrak, Haydar;Sahin, Sezgi Cinel;Gurbulak, Aysegul Guleryuz
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.262-270
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS. Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ${\times}30$ magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS. A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, $98.8{\pm}16.43{\mu}m$; canine, $93.59{\pm}16.82{\mu}m$; premolar, $104.10{\pm}15.02{\mu}m$) had larger marginal misfit values than those in Group Cdi (average, $63.78{\pm}14.05{\mu}m$; canine, $62.73{\pm}13.71{\mu}m$; premolar, $64.84{\pm}15.06{\mu}m$) and Group Tdi (average, $65.14{\pm}18.05{\mu}m$; canine, $70.64{\pm}19.02{\mu}m$; premolar, $59.64{\pm}16.10{\mu}m$) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION. The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적 안정성 평가 (Evaluation of Dimensional Stability of Digital Dental Model Fabricated by Impression Scanning Method)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제14권1호
    • /
    • pp.15-21
    • /
    • 2014
  • 본 연구에서는 구강으로부터 채득된 인상체를 스캐닝하여 디지털 모형을 제작하였을 때 제작된 디지털 모형의 체적 안정성을 평가하고자 하였다. 그리하여 환자의 구강을 가정한 상악 모형을 본 모형으로 채택하였다. 본 모형과 동일한 증례의 연구 모형을 치과용 석고를 이용하여 총 20개의 석고 모형을 제작하였다. 제작된 연구 모형 20개를 치과용 기성 트레이와 두 종류의 치과용 인상재를 이용하여 20개 연구 모형을 대상으로 20개의 인상을 채득하였다. 채득된 20개의 인상체를 치과용 스캐너로 스캐닝하는 방식으로 디지털 모형으로 변환하였다. 체적 안정성을 평가하기 위하여 6개의 대표 지점을 선정한 뒤 디지털 모형과 함께 디지털 모형의 근간인 석고 모형을 계측하였다. 그 결과 계측된 모든 부위에서 디지털 모형이 석고 모형보다 체적이 작은 것으로 조사되었고, 이는 통계적으로 유의하였다(p<0.05). 이러한 결과들로 추론하여 보았을 때 환자의 구강으로부터 채득된 인상체를 스캐닝하여 제작한 디지털 모형의 체적은 환자의 구강보다 작다는 것을 알 수 있었다. 그러나 이 차이는 미비한 것으로 여러 선행 연구 결과들을 근거로 하였을 때 임상적으로 허용이 가능한 것으로 생각된다.

Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies

  • Louis Hardan;Rim Bourgi;Monika Lukomska-Szymanska;Juan Carlos Hernandez-Cabanillas;Juan Eliezer Zamarripa-Calderon;Gilbert Jorquera;Sinan Ghishan;Carlos Enrique Cuevas-Suarez
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.315-332
    • /
    • 2023
  • PURPOSE. This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS. This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS. The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION. The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction

  • Pereira, Ana Larisse Carneiro;Medeiros, Vitoria Ramos;Campos, Maria de Fatima Trindade Pinto;Medeiros, Annie Karoline Bezerra de;Yilmaz, Burak;Carreiro, Adriana da Fonte Porto
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.212-222
    • /
    • 2022
  • PURPOSE. To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed completearch frameworks, as well as on patient satisfaction. MATERIALS AND METHODS. 17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (P<.05). RESULTS. The time with DI was shorter than with CI (DI, $\tilde{x}=02:58$; CI, $\tilde{x}=31:48$) (P<.0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: $\tilde{x}=05:36$; 4: $\tilde{x}=09:16$) (P<.0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (P<.005). CONCLUSION. Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.

치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성 연구: 3차원 중첩 분석 (Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis)

  • 김기백;정재관;김재홍
    • 치위생과학회지
    • /
    • 제14권2호
    • /
    • pp.94-100
    • /
    • 2014
  • 본 연구는 임상에서 널리 사용되고 있는 3종류의 탄성 인상재를 치과용 백색광 스캐너로 스캔하여 얻어진 데이터와 석고 지대치 모형과의 차이를 비교분석하였다. 인상재의 물성 차이가 3차원 디지털 모형의 정확성에 어떠한 영향을 미치는지 3차원 중첩 분석법을 통해 평가함으로써 다음과 같은 결과를 얻었다. 석고 지대치 모형과 3종류의 인상재를 토대로 채득된 디지털 모형의 차이를 비교한 결과, HB 그룹이 $9.80{\pm}1.52{\mu}m$ 로 가장 큰 차이를 보였으며, XLB 그룹이 $5.10{\pm}1.45{\mu}m$로 가장 작은 차이를 나타내었다. 음형의 인상체 간의 정확성에 있어서는 측정된 평균값이 통계적으로 유의한 차이를 보였다(p<0.05). Color difference map의 결과에서도 HB 그룹에 비해 XLB 그룹이 오차가 0에 가까운 연두색의 분포가 넓게 나타났기에, 더욱 안정적이며 정확한 디지털 모형 채득이 가능한 탄성 인상재라는 결론을 내릴 수 있다. 아직까지는 음형의 인상체 스캔방식은 표면의 혈흔이나 난반사, 중합 수축 등 좀 더 개선하고 보완해야 할 문제점들이 존재하기 때문에 널리 사용하진 않지만, 석고 모형과 비교하였을 때 전체적인 오차범위가 크지 않기에 임상적으로 허용될만한 수준으로 생각된다.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향 (The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression)

  • 김기백;이경탁;김혜영;김재홍
    • 치위생과학회지
    • /
    • 제12권6호
    • /
    • pp.617-623
    • /
    • 2012
  • 본 연구는 치과용 모형재 중 4형(type IV)석고와 스캔용(scannable)석고를 이용하여 작업모형을 제작한 후, 치과용 백색광 스캐너를 이용하여 3차원 디지털 모형으로 전환한 데이터의 계측지점간 거리를 측정하여, 그 결과 값을 토대로 이종의 치과용 석고가 3차원 디지털 모형의 크기재현 시 정확성여부를 비교하였다. 본 실험을 통하여 치과용 모형재에 따른 3차원 디지털 모형의 정확도를 확인함으로써 임상 적용의 가능성을 평가하였으며, 제한된 조건 하에서 수행된 본 연구에서 다음과 같은 결론을 얻었다. 1. 치과용 백색광 스캐너를 사용하여 주 모형과 두 종류의 모형재로 제작한 작업모형을 3차원 디지털 모형으로 전환한 후, 선계측의 값을 비교한 결과 전체적인 계측지점에서 모두 모형재로 제작된 작업모형이 작게 계측되는 경향을 보였다. 2. 각 모형별 동일한 계측지점의 계측값의 차이가 있는지 알아보기 위해 paired t-test의 시행결과, 모든 계측지점에서 통계적으로 유의한 차이를 보였다(p<0.05). 결론적으로 두 가지 석고 모두 통계적으로 적정한 수준의 정확성을 나타내지 않았으나, 오차 수준이 선행연구에 비추어 볼 때 임상적으로 수용 가능한 수준이라 생각된다. 전악 인상채득을 통한 디지털 모형의 정확성은 검증이 되었으나, 스캔용(scannable)석고에 대한 임상 효용성을 판단하기 위해 타 제품과의 성분 분석 비교연구나 실질적인 보철물 제작을 통한 적합도 평가를 통해 CAD/CAM 보철물 제작 시장점을 부각할 수 있는 연구가 뒷받침되어야 할 것으로 사료된다.

디지털 인상법과 전통적 인상법의 정확도 비교: 체계적 고찰 (Comparison of the accuracy of digital impressions and traditional impressions: Systematic review)

  • 김경록;서권수;김선재
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.258-268
    • /
    • 2018
  • 목적: 본 연구는 보철물의 적합 및 인상의 정확성에 관한 문헌들을 체계적으로 고찰하여 구강 내 스캐너를 이용한 디지털 인상법이 전통적인 인상법을 대체할 만한 정확도를 보이는지 알아보고자 한다. 재료 및 방법: 1997년 8월 1일부터 2017년 7월 31일까지 출판된 영어로 쓰여진 연구를 대상으로 디지털 인상법의 정확성에 대한 문헌을 MEDLINE/PubMed 전자 검색 및 수기탐색을 시행하였다. 조건에 따라 선택된 연구의 데이터를 스프레드 시트에 2명의 검토자가 독립적으로 정리하였다. 결과: 총 35개의 연구가 선택되었고, 26개의 연구는 보철물의 적합성을 비교하였고 9개의 연구는 보철물 없이 스캔 데이터를 통해 인상의 정확성을 비교하였다. 대부분의 연구가 보철물을 이용해 인상법의 정확성을 비교하였다. 결론: 본 고찰에 따르면 자연치열에서 디지털 인상법으로 단일관이나 근원심으로 길이가 짧은 보철물을 제작하는 것은 임상적으로 충분히 신뢰할만한 하다. 그러나 디지털 인상법으로 길이가 긴 보철물을 제작하는 것은 연구가 적어 아직 한계가 있다. 임플란트 보철물 제작에 있어서 구내스캐너를 이용한 디지털 인상법으로 전통적인 인상법을 완전히 대체하기는 아직 어렵다.