• 제목/요약/키워드: Dental ceramic

검색결과 560건 처리시간 0.027초

치과용 타타늄-세라믹 수복시스템의 결합강도 향상을 위한 표면 코팅 (Surface Coatings to Enhance Bonding Strength of Dental Titanium-Ceramic Restorative System)

  • 이해형
    • 한국세라믹학회지
    • /
    • 제45권10호
    • /
    • pp.600-604
    • /
    • 2008
  • Although titanium-ceramic systems have gained substantial interests in dental prosthetic field, bonding problem between porcelain and titanium has not been solved. Main obstacle in titanium-porcelain bonding is excessive oxidation of titanium during porcelain firing. The effects of several coating materials on the bonding strength of titanium-porcelain system were investigated in this study. RF sputtering and electroplating of platinum significantly increased the bonding strength of porcelain-titanium specimen. However, coatings of Ni-Au, Ir, and ceramics(zirconia and hydroxyapatite) did not showed a significant effect on bonding strength. Platinum might be a promising material for the protective layer of excessive oxidation of titanium during porcelain firing, resulting in increase in the bonding strength.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

치과 임플란트용 골융합 측정기의 설계 및 평가 (Design and Evaluation of Osseointegration Analysis System for Dental Implant)

  • 이주희;김창일;백종후;조정호;전명표;정영훈;이영진;이정배;이승대
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.188-193
    • /
    • 2011
  • The osseointegration of dental implant is influenced by many factors such as surface geometry, loading and the amount of bone. Thus, stability of the dental implant should be checked periodically. In order to test the stability of dental implant by using resonance frequency analysis, we designed a structure of transducers and fabricated a piezoelectric devices. Using finite element analysis, the thickness and length of piezoelectric device and transducers were tailorized and the optimized frequency of 10 kHz was obtained. The resonance frequency from simulation analysis and evaluation was estimated to be similar as 10 kHz. The osseointegration was further enhanced with increasing frequency from the evaluation result of the finite element analysis.

Comparison of Temperatures of the Resin Cement in Polycrystalline Ceramic Brackets Irradiated Using a Diode Laser

  • Son, Young-Tak;Son, KeunBaDa;Kim, Kyung-Min;Lee, Jae-Mok;Kim, Jin-Wook;Yu, Wonjae;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.69-78
    • /
    • 2021
  • Purpose: The primary objective of this study was to evaluate the change in the temperature of the adhesive resin in polycrystalline ceramic brackets irradiated using a diode laser at different irradiation energy levels and times. Materials and Methods: For the measurement of the temperature of the adhesive resin, it was applied at the base of the ceramic bracket, a thermocouple was placed at the center of the base surface, the bracket was placed on prepared resin specimens for light curing, and a laser was irradiated to the center of the bracket slot at 5, 7, and 10 W. For the measurement of the temperatures of the enamel under the bracket and pulp cavity, extracted premolar was fixed to a prepared mold and the ceramic bracket was bonded to the buccal surface of the premolar. The Kruskal-Wallis H test and Friedman test were used for statistical analysis. Result: At 5 W, the temperature of the adhesive resin did not reach the resin softening temperature of 200℃ within 30 seconds. At 7 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 28 seconds. At 10 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 15 seconds. During laser irradiation, the temperature of the enamel under the bracket increased by over 5℃ within 15 seconds. Conclusion: The use of diode laser irradiation for bracket debonding should be carefully considered because the pulp cavity temperature increases by over 5℃ within the irradiation time for resin thermal softening.

Effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength of composite to ceramic

  • Armaghan Naghili;Amirparsa Ghasemi;Amir Ghasemi;Narges Panahandeh
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.163-173
    • /
    • 2024
  • PURPOSE. This study assessed the effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength (µSBS) of composite to ceramic. MATERIALS AND METHODS. This study was conducted on 60 sintered zirconia and 60 feldspathic porcelain blocks. Half of the specimens (n = 30) were subjected to surface treatment with the single-bottle Clearfil ceramic primer (n = 15) and two-bottle experimental primer (n = 15) after 24 hours. The remaining half received the same surface treatments after 6 months storage in distilled water. Composite cylinders were bonded to the ceramics, and they were then subjected to µSBS test. Also, the primers underwent Fourier-transform infrared spectroscopy (FTIR) after 24 hours and 6 months to assess their chemical structure. Data were analyzed with 3-way ANOVA and adjusted Bonferroni test (alpha = 0.05). RESULTS. The µSBS of both ceramics significantly decreased at 6 months in one-bottle ceramic primer group (P = .001), but it was not significantly different from the two-bottle experimental primer group (P = .635). FTIR showed hydrolysis of single-bottle primer, cleavage of silane and 10-MDP bonds, and formation of siloxane bonds after 6 months. CONCLUSION. Six months of storage caused significant degradation of single-bottle ceramic primer, and consequently had an adverse effect on µSBS.

전치부 전부도재관을 이용한 테트라싸이클린 착색의 심미보철 회복 증례 (IPS e.max CAD 블록의 이용) (Esthetic Rehabilitation of Anterior Dentition by All Ceramic Crowns Using IPS e.max CAD : A Case of Tetracycline Discoloration)

  • 김재홍;조영규;김혜영
    • 치위생과학회지
    • /
    • 제11권4호
    • /
    • pp.299-303
    • /
    • 2011
  • The purpose of this case report was to present an example of an esthetic and functional rehabilitation of anterior teeth with tetracycline discoloration and minor morphological abnormality of a 39-year old female. A chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with CEREC AC was applied for the prosthetic procedure and all ceramic crowns made with lithum disilicate (IPS e.max CAD) restored the esthetic and functional features of sixteen anterior teeth successfully.

Ceramic veneers without tooth reduction: A clinical report

  • Lee, Wonsup;Kwon, Ho-Beom
    • 대한치과의사협회지
    • /
    • 제54권5호
    • /
    • pp.342-347
    • /
    • 2016
  • This clinical report presents conservative and esthetic ceramic veneer treatments without tooth reduction. Patients' benefit from avoiding invasive procedure is discussed in terms of biologic price. The margin is placed not only at the cervical area, but also at any place on the tooth where additive volume increase is required. Techniques to camouflage the margin is described where contact lens effect is difficult to achieve. Proper case selection would be imperative to avoid periodontally hazardous restoration.

  • PDF

치과용 지르코니아 블럭의 착색시간에 따른 색조변화 관찰 (Evaluation of Color Change According to Coloring Time of Dental Zirconia Block)

  • 최성민;남상용
    • 대한치과기공학회지
    • /
    • 제33권3호
    • /
    • pp.219-224
    • /
    • 2011
  • Purpose: The current study focused on investigating color change of dental zirconia block with respect to the block coloring time. Methods: Three types of dental zirconia blocks(Zirtooth, Pearl-HT, D-Max) were tinted with coloring agent under four different time condition (0 minutes, 1 minutes, 10 minutes, 30 minutes). The quantitative evaluation of the tinted dental zirconia blocks was conducted with spectrophotometer. Results: The Zirtooth and D-Max blocks showed lower H value. The Pearl-HT blocks showed poor reflectivity(L value). Conclusion: The study of color change of zirconia block, which consists the substructure of all ceramic Crown, is applicable for deciding appropriate coloring condition when fabricating one layer ceramic Crown or double layer ceramic Crown.