• Title/Summary/Keyword: Dental alloys

Search Result 316, Processing Time 0.024 seconds

Hydroxyapatite Precipitation Phenomena on Micro-pore Formed Ti-Nb Alloy by PEO technique

  • Kim, Jeong-Jae;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.137-137
    • /
    • 2015
  • The purposed of this work was to observe hydroxyapatite precipitation phenomena on micro-pore formed Ti-Nb alloy by PEO technique. The Ti-30Nb and Ti-30Ta alloys were remelted at least ten times in order to avoid inhomogeneity, and then cylindrical specimens (diameter 10 mm, thickness 4 mm) were cut by using laser from cast ingots of the Ti alloys. Heat treatment was carried out at $1050^{\circ}C$ for 2 h for homogenization in argon atmosphere. The morphologic change of the alloys were examined by X-ray diffractometer (XRD) and field emission scanning electron microscopy (FE-SEM).

  • PDF

EXPERIMENTAL STUDY ON EFFECTS OF GOLD ALLOYS CROWN MARGIN IN THE RABBIT'S PERIODONTIUM (금합금관연이 가토치근막에 미치는 영향에 관한 실험적 연구)

  • Chang, Wan-Sik
    • The Journal of the Korean dental association
    • /
    • v.9 no.6
    • /
    • pp.293-296
    • /
    • 1971
  • Histochemical observations on the effect of gold alloys crown margin in the periodontal membrane were caried out by use of rabbits. The animal were setted with gold alloys crown on the incisor teeth. The cervical margins were given extence into gingival sockets. The animals were sacrificed at the 30 days experimented period. Specimens of tissue were obtained from the mandibular incisor teeth with jaw. All tissues were fixed immediately in 10% neutral formalin solution. Different histochemical staining methods for the determination of fibrous components were the Mallory-Heidenhain Bielschowsky-Gomori, Gomori's aldehyde fuchsin. Periodic acid-Schiff reaction and Hematoxylin eosin stanin method. The results were as follows. The periodontal membrane is composed primarily of collagenous fibers and fibrous component run functional arrangement but in lower gold content groups, horizontal fiber groups were irregularly run. Elastic fibers were obligue run in experimental groups. There were no significant differences in reticularfibers in distribution.

  • PDF

Nanotube Morphology Change of Ti-6Al-4V Alloys by Heat Treatment

  • Kim, Sung-Hwan;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.194-194
    • /
    • 2013
  • In order to investigate nanotube morphology change of Ti-6Al-4V alloys by heat treatments, the Ti-6Al-4V alloys were used in this study. In non-treated Ti-6Al-4V alloy case, nanotubes only exhibited at ${\alpha}$ phase region with dissolved V-oxide area of ${\beta}$ phase. However, in Ti-6Al-4V alloy at $800^{\circ}C$ WQ case, nanotubes exhibited at both ${\alpha}$ and ${\beta}$ phase region. Electrochemical corrosion studies showed that the nanotubular alloy at $800^{\circ}C$WQ possesses slightly higher corrosion resistance than non-treated nanotubular alloy.

  • PDF

Wear Properties of Cast Titanium Alloys for Dental Use (치과용 Titanium 주조합금의 마멸특성)

  • Choi, Seok-Kyu;Kim, Hyung-Il;Park, Ik-Min
    • Journal of Korea Foundry Society
    • /
    • v.11 no.6
    • /
    • pp.482-490
    • /
    • 1991
  • This study presents the wear characteristics of Ti alloys (Pure Ti, Ti-6Al-4V, Ti-5Al-2.5Sn) fabricated by centrifugal precision casting in an Ohara dental titanium casting machine. It was found that the hardness of the surface region is higher than that of the interior region. It is considered that the oxygen adsorption in the surface region during casting, leads to the interstitial solid solution hardening. Wear resistance incerases in the order of pure Ti, Ti-6Al-4V, Ti-5Al-2.5Sn alloys. The interior hardness value increases in the same order. The specific wear rate increases with applied load and increases monotonously with sliding speed. The Fe transfer from the counterpart material was observed on the worn surface of the Ti-5Al-2.5Sn alloy. Oxidative wear occurs at low sliding speeds and mechanical fracture wear occurs at high sliding speeds.

  • PDF

Electrochemically Fromed Nanotube Shape on Ternary Ti Alloy with Hf Content

  • Kim, Jeong-Jae;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.106-106
    • /
    • 2015
  • In this study, we investigated electrochemically formed nanotube shape on ternary Ti-25Ta-xHf alloys with Hf contents. Ti-25Ta-xHf (x=0~15 wt.%) alloys were manufactured by vacuum arc-melting furnace. The obtained ingots were homogenized in an argon atmosphere at $1050^{\circ}C$ for 2h and then water quenching. The specimens were cut from ingots to 4 mm thickness and first ground and polished using SiC paper (grades from #100 to #2000). The anodization treatments on Ti-25Nb-xHf alloys were carried out at room temperature for experiments. The formation of nanotubular film was conducted by electrochemical method in mixed electrolytes with 1 M $H_3PO_4$ + 0.8 wt. % NaF at 30 V for 2 h. The morphologies of nanotube depended on the Hf content in Ti-25Ta-xHf ternary system.

  • PDF

A Study on the Viability of Human Dermal Fibroblast Cell by Media for Ni-Cr alloy elution (치과용 Ni-Cr합금 용출배지에 의한 인간 피부 섬유아세포 성장도 관찰 연구)

  • Kim, Kap-Jin;Choi, Sung-Min;Kim, Chi-Young
    • Journal of Technologic Dentistry
    • /
    • v.31 no.3
    • /
    • pp.21-26
    • /
    • 2009
  • Purpose: Standards of alloy for porcelain fused to metal crown be classified by metallic factor and biological factor. Metallic factors consist of stability of alloy composition and mechanical strength and surface characteristics for chemical bond. Biological factors be considered properties of metallic elements and problems originated by toxicity and hypersensitive reaction. Alloys considered such controversial points are the most suitable alloy for dental instrument. Method: Alloys added Be and Nb using Ni-Cr alloy which has been widely used for dental instrument be selected and classified experimental group. Non-addition Be and Nb to Ni-Cr alloy classify control group and addition Be alloy is Be-experimental group, addition Nb alloy is Nb-experimental group. Specimens for cytotoxicity analysis gave effect to washing and sterilization. and then made an experiment on elution with cell medium after disinfection. It conducted specimens within cell medium with 24hours, 48hours, 72hours, respectively. It cultured human dermal fibroblast(HDF) using cell medium for cytotoxicity test and then investigated elution rate through spectroscopic analysis by MTT-assay. Result: As results of cytotoxicity test by MTT-assay, cultured cell rate of VII measured more low numerical value within elution medium for 24hours focused on control group. Also, cultured cell rate of K3 alloys observed low value for 48hours, 72hours than value of control group. Conclusion: According to final result that synthesize above results, Ni-Cr alloy added Be and Ni has little difference in Cytotoxicity by MTT-assay.

  • PDF

Dental Co-Cr alloys fabricated by selective laser melting: A review article (선택적 레이저 용융 방법으로 제작한 치과용 코발트 크롬 합금에 대한 문헌고찰)

  • Kang, Hyeon-Goo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.248-260
    • /
    • 2021
  • Cobalt-chromium alloys are used to fabricate various dental prostheses, and have advantages of low cost and excellent mechanical properties compared to other alloys. Recently, selective laser melting, which is an additive manufacturing method, has been used to overcome the disadvantages of the conventional fabrication method. A local rapid heating and cooling process of selective laser melting induces fine microstructures, grain refinement, and reduction of porosities of the alloys. Therefore, it can improve mechanical properties compared to the alloys fabricated by the conventional method. On the other hand, layering process and rapid heating and cooling cause accumulation of a large amount of residual stresses that can adversely affect the mechanical properties. A heat treatment for removing residual stresses through recovery and recrystallization process caused complicated changes in mechanical properties induced by phase transformation, precipitate and homogenization of the microstructures. The purpose of this review was to compare the manufacturing methods of Co-Cr alloys and to investigate the characteristics of Co-Cr alloys fabricated by selective laser melting.

The effect of preheat treatment on ceramic to metal bond strength (도재-금속의 결합 강도에 미치는 비금속 합금의 열처리 효과)

  • Kim, Chi-Young;Kim, Young-Gon; Cho, Hyun-Seol
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.33-41
    • /
    • 2002
  • In dental prosthetics, the application of metal-ceramic restorations has steadily increased since their introduction. This is due to excellent esthetics in combination with high mechanical stability. In order to optimum bond strength between metal and ceramics, controlled oxidation of metal substructure is essential factor. Beryllium containing and beryllium free Ni-Cr alloys for metal-ceramic restorations were evaluated for the metal-ceramic bond strength by changing heat treatment for oxide formation. A mechanical three-point bending test was employed to evaluate the interfacial bond strength of metal-ceramic. In each metal, plate type specimens were used for mechanical three-point bending test. With Ni-Cr alloys for metal ceramics, mechanical three-point bending test showed that double degassing was more available preheat treatment method than another. It was found that beryllium containing Ni-Cr alloys are more effective than beryllium-free for metal-ceramic bond strength.

  • PDF

The Influence on Castability of Nickel-Chromium Alloys according to Burn-out Temperature and Recast Content Ratio (소환온도(燒還溫度)와 재(再) 주조금속(鑄造金屬) 함량비(含量比)가 Ni-Cr계(係) 비귀금속(非貴金屬) 합금(合金)의 가주성(可鑄性)에 미치는 영향)

  • Lee, Hyo-Byeang
    • Journal of Technologic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.51-55
    • /
    • 1986
  • The castability of base metal alloys for dental casting in influenced by burn-out temperature and recent percentage. Burn-out temperatures for casting are set at 200$^{\circ}F$ interval from 1000$^{\circ}F$ to 1800$^{\circ}F$. According to recast metal percent in new cast alloy metal alloys are tested. The results are as followings: 1. In the new alloy(100%), the castability is the most. 2. The burn-out temperature in 1600$\sim$1800$^{\circ}F$, castability of 100% new alloy was more four times than of 50% new alloy plus 50% recast alloy. The using of 50% new alloy and 50% recast alloy, therefore, was unlike in castability. 3. The burn-out temperature in 1600$^{\circ}F$, castability of 100% new alloy was more than four times in soaking 20 minutes, but there was no any difference at 18700$^{\circ}F$. 4. It is investigated that the optimal burn-out temperature is 1600$^{\circ}F$ for the C & B alloy.

  • PDF