• Title/Summary/Keyword: Dental Scanner

Search Result 267, Processing Time 0.032 seconds

Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system (치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석)

  • Kim, Won-Soo;Han, Man-So;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

Validity of Arch Relationship Measurements in Digital Dental Models (디지털 치열 모형에서 악궁 관계 지표 측정의 타당성)

  • Ryu, Jiin;Yang, ByoungEun;Lee, Hyelim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.14-24
    • /
    • 2022
  • The aim of the present study is to evaluate the validity of orthodontic measurements including tooth width, Bolton ratio, overjet and overbite on the digital dental models. Dental models of the subjects aged 12 to 18 were obtained in 3 different forms, which were conventional stone model, digital model created with Freedom HD model scanner, and digital model produced with CS3600 intraoral scanner. After measurements were made on the models, reliability and reproducibility of the measurements were evaluated by using intraclass correlation coefficient, while validity was assessed with paired t-test. As a result, significant reliability and reproducibility were verified, with intraclass correlation coefficient exceeding 0.750 in all groups. Measurements of the model scanned group showed an adequate validity in overall and anterior Bolton ratio, overjet, and overbite. Intraoral scanned models showed an adequate validity in anterior Bolton ratio, and overjet. Measurement on intraoral scanned digital models can be considered as an alternative for young children who have difficulty in taking impression. Furthermore, careful considerations on measurement error should be made in clinical situations.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Perceptions of dental hygienists toward digital dentistry (치과 디지털 활용에 관한 치과위생사의 인식)

  • Kim, Young-Sun;Park, Hyun-Suk;Ku, In Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.6
    • /
    • pp.909-916
    • /
    • 2013
  • Objectives : The purpose of this study was to investigate the perceptions of dental hygienists toward digital dentistry. Methods : The subjects were 393 dental hygienists in Daegu Gyeongbuk. A total of 380 data were analyzed except the incomplete questionnaires. Data were analyzed by descriptive statistics, chi-square test, t-test, one-way ANOVA using SPSS version 18.0. Results : 1. Difference of perception by general characteristics was affected by age, academic background, working career, and married. 2. Difference of perception by utilization of digital facilities was affected by digital camera, CAD/CAM system, oral scanner, and computer system. 3. Difference of perception by digital education experience and intention of participation was affected by stronger intention to participate in digital education and practical exercise. Digital X-ray system and CAD/CAM system were the must-be equipment in education. Conclusions : Utilization of digital dentistry is the motive for education experience in dental hygienists.

Comparison of marginal fit of metal copings according to wax blocks and oral scanning methods (구강인기법과 왁스블록의 종류에 따른 금속 코핑의 변연적합도 비교)

  • Chung, In-Sung;Kim, Won-Young;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.234-239
    • /
    • 2020
  • Purpose: We investigated the marginal fit between abutment and metal copings according to impression technique, wax block types, and metal types. Methods: We selected the traditional impression method of using rubber impression materials and the digital impression method of using oral scanners, three types of wax blocks, and two types of metal, both of which were domestically and commercially available, were selected to produce metal copings, and the marginal fit was determined through the use of silicon replication. Results: The measurements of axial wall fit revealed that the IYV specimens had the best fit, with a mean gap of 24.11±5.95 ㎛, followed by CEV, CHV, CSS, CSV, CES, CHS, and IYS specimens (mean: 33.44±8.41 ㎛). The differences were not statistically significant. The marginal gap measurements showed that the CEV specimen had the smallest gap, 17.25±4.13 ㎛, followed by the CSV, CHV, CSS, CES, CHS, IYV, and IYS specimen (mean: 43.47±15.63 ㎛). The differences were statistically significant. Conclusion: The axial wall fit of the metal coping (VeraBond2V; Aalba Dent, Inc., Fairfield, CA, USA) produced by the lost wax technique with the traditional impression method was excellent. The marginal fit of the metal coping (VeraBond 2V) produced by wax milling with the use of an oral scanner was also excellent. The marginal fit of the metal coping was within the clinically acceptable limits in all groups.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept

  • Hilin, Tas;Fatih, Demirci;Mesut, Tuzlali;Erkan, Bahce;Guler Yildirim, Avcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.379-387
    • /
    • 2022
  • PURPOSE. The aim of this study is to compare the casts obtained by using conventional techniques and liquid crystal display (LCD) three-dimensional (3D) print techniques in the All-on-4 treatment concept of the edentulous mandibular jaw. MATERIALS AND METHODS. In this study, a completely edentulous mandibular acrylic cast (typodont) with bone-level implants placed with the Allon-4 technique served as a reference cast. In this typodont, impressions were taken with the conventional technique and dental stone casts were obtained. In addition, after scanning the acrylic cast in a dental laboratory scanner and obtaining the Standard Tessellation Language (STL) data, 3D printed casts were manufactured with a 3D printing device based on the design. The stone and 3D printed casts were scanned in the laboratory scanner and STL data were obtained, and then the interimplant distances were measured using Geomagic Control X v2020 (3D Systems, Rock Hill, SC, USA) analysis software (n = 60). The obtained data were statistically evaluated with one-way analysis of variance (ANOVA) and Tukey's pairwise comparison tests. RESULTS. As a result of the one-way ANOVA test, it was determined that the stone casts, 3D printed casts, and reference cast values in all distance intervals conformed to the normal distribution and these values had a significant difference among them in all distance intervals. In Tukey pairwise comparison test, significant differences were found between casts at all distance intervals. In all analyses, the level of significance was determined as .05. CONCLUSION. 3D printed casts obtained with a 3D LCD printing device can be an alternative to stone casts when implants are placed in edentulous jaws. [J Adv Prosthodont 2022;14:379-87]

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system (동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.