• 제목/요약/키워드: Dental Porcelains

검색결과 19건 처리시간 0.022초

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

도재의 재료와 축성방법에 따른 표면거칠기의 비교 (Comparison of Surface Roughness according to Porcelain Materials and Condensation)

  • 이청희
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.179-184
    • /
    • 2002
  • To compare surface roughness in various porcelains and know effects of condensation, We used Ceramco dentin porcelain, Creation dentin porcelain, Creation margin porcelain, Vintage margin porcelain, Vintage dentin porcelain, and Vita dentin porcelain, and built up the powders with condensation or not, and then fired according to the instructions with porcelain furnace( Dekema, Germany ). We polished the samples step by step using the porcelain adjustment kit( Shofu Inc., Japan ), and then measured, compared and analysed Ra, Rz, and Rmax with Surftest SV-400( Mitutoyo Co., Japan ). 1. With condensation, roughness is significantly increased in Ceramco dentin porcelain (p<0.05) and decreased in Vita dentin porcelain(p<0.05). 2. In Ra, Vita dentin porcelain is significantly the roughest and Creation margin porcelain is rougher than others in no condensation, (p<0.05), and there is no difference under condensation. 3. In Rz, Vita dentin porcelain is significantly the roughest and Creation margin porcelain is rougher than others in no condensation, and Creation margin porcelain is significantly the roughest and Creation dentin porcelain is rougher than others under condensation(p<0.05). 4. In Rmax, Vintage dentin porcelain is significantly the roughest and Creation margin porcelain is rougher than others in no condensation, and Creation margin porcelain is significantly the roughest than others under condensation(p<0.05).

CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도 (Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems)

  • 강후원;김희진;김장주;고명원
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

치과용도재에 의한 법랑질 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF DENTAL PORCELAINS AND HUMAN ENAMEL)

  • 이영국;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.51-70
    • /
    • 1999
  • Dental porcelain is one of the materials of choice for restoration where esthetics is of concern, but has a considerable potentials of wear. The wear of enamel is variable when opposed by different porcelain systems and surface conditions, and the exposed dentine and opaque porcelain due to clinical failure is expected to have high potentials of wear. The purpose of this study was to investigate the wear effects of self-glazed, polished incisal porcelain. polished dentine and opaque porcelain against human enamel in the laboratory by use of a pin-on-disk type wear tester. 4 types of dental porcelain($Vita-{\Omega}$, Ceramco-II, Vintage powder $Vita-{\alpha}$ of In-Ceram system) and type IV gold alloy as cotrol group were used for test specimens. Intact buccal cusps of maxillary premolar were used for enamel specimens, and the cusp converged to a point and was devoid of visible abrasion, caries, decalcification. The upper part was the cusp of a maxillary premolar and the lower part was a porcelain specimen. The enamel wear was deter-mined by weighing the cusp before and after each test. Surface profilometer was used to quantitate wear of the porcelain specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows : 1 Self-glazed porcelain produced more enamel wear than polished porcelain, especially the enamel wear of $Vita-{\alpha}$ self-glazed porcelain was 3.2 times more than that of other groups. 2. Opaque porcelain produced least porcelain wear, $Vita-{\alpha}$ self-glazed porcelain produce greatest porcelain wear, but there was no statistically significant difference between the groups(p>0.05). 3. The enamel wear of dentine porcelain was 3.8 times more than that of polished inisal porcelain(p<0.05), and the enamel wear of opaque porcelain was 1.9 times more than that of polished inisal porcelain, but there was no statistically significant difference between the groups(p>0.05) 4. Overglazed porcelain produced less enamel wear than self-glazed porcelain, and more enamel wear than polished porcelain, but there was no statistically significant difference between the groups(P>0.05). 5. The hardness number of $Vita-{\Omega}$ dentine and Ceramco-II opaque porcelain was larger, but that of Vintage dentine and $Vita-{\alpha}$ self-glazed porcelain was similar to other groups. 6. Examination of SEM photographs revealed that overglazed porcelain had smoother surface than self-glazed porcelain, and self-glazed porcelain had smoother surface than polished porcelain. Much polishing scratches and larger porosities were observed on the opaque porcelain specimen, and much polishing scratchess and small porosities were observed on the dentine porcelain specimen.

  • PDF

All-ceramic Crown 용 도재의 굽힘강도에 관한 비교연구 (A COMPARATIVE STUDY ON THE FLEXURE STRENGTH OF THE CERAMICS FOR ALL-CERAMIC CROWNS)

  • 유형우;송창용;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.195-211
    • /
    • 1994
  • The purpose of this study was to evaluate the fracture resistance of the four kinds of dental porcelains for the all-ceramic crown(Vita In-Ceram, Vita Hi-Ceram, IPS-Empress, Vitadur-N) and one kind for the metal-ceramic non(Vita VMK 68) was used as the control group. In order to determine the fracture resistance, the hi-axial flexure strength was measured at a crosshead speed of 0.5mm/min, and the Vickers hadrness was measured at an indentation load of 1kg for 20 seconds. The results obtained were summarized as follows ; 1. The maximum Weibull modulus of 24.61 for Vitadur-N and the minimum one of 852 for IPS-Empress were observed ; the maximum characteristic strength of 353.26MPa for Vita In-Ceram and the minimum that of 63.20MPa for Vitadur-N were also observed. 2. The maximum mean bi-axial flexure strength of 339.12MPa for Vita In-Ceram and thd minimum one of 61.99MPa for Vitadur-N were calculated. Results of the Scheffe test indicated that the statistically significant difference(P<0.05) existed between Vita In-Ceram or Vita Hi-Ceram and the others ; also between IPS-Empress and Vitadur-N. 3. The maximum mean hardness of $980.55kg/mm^2$ for Vita VMK 68 appeared. Results of the Scheffe test indicated that statistically significant difference(P<0.05) existed between Vita In-Ceram or Vita Hi-Ceram and the others ; also between IPS-Empress and Vita VMK 68.

  • PDF

지르코니아-전장도재 계면의 전단결합강도에 대한 ZirLiner® 적용과 분사처리의 영향에 관한 연구 (Effect of Application of ZirLiner® and Blasting Treatments on Shear Bond Strength of Zirconia-Veneered Porcelain Interface)

  • 신영호;이유나;이해형;동진근;오상천
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.113-127
    • /
    • 2008
  • 이 연구의 목적은 지르코니아 도재 표면의 전단 결합 강도에서 $ZirLiner^{(R)}$와 블라스팅 처리의 적용 효과를 평가하기 위한 것이다. 60개의 무색의 지르코니아 판과 30개의 색이 있는 지르코니아 판이 규격화되고 연마, 글래스블라스팅, 알루미나블라스팅, 그리고 zirliner 같은 블라스팅 처리를 적용시키는 것에 따라 10개씩 9개의 그룹으로 나누어졌다. 시편을 고정대에 위치하고 만능시험기로 전단력을 측정하였다. 파절된 견본의 파절 표면은 SEM으로 검사되었다. 각 군별 시편을 통계처리하여 그 결과를 비교하였다.

CERAMIC INLAY RESTORATIONS OF POSTERIOR TEETH

  • Jin, Myung-Uk;Park, Jeong-Won;Kim, Sung-Kyo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 춘계학술대회
    • /
    • pp.235-237
    • /
    • 2001
  • ;Dentistry has benefited from tremendous advances in technology with the introduction of new techniques and materials, and patients are aware that esthetic approaches in dentistry can change one's appearance. Increasingly. tooth-colored restorative materials have been used for restoration of posterior teeth. Tooth-colored restoration for posterior teeth can be divided into three categories: 1) the direct techniques that can be made in a single appointment and are an intraoral procedure utilizing composites: 2) the semidirect techniques that require both an intraoral and an extraoral procedure and are luted chairside utilizing composites: and 3) the indirect techniques that require several appointments and the expertise of a dental technician working with either composites or ceramics. But, resin restoration has inherent drawbacks of microleakage. polymerization shrinkage, thermal cycling problems. and wear in stress-bearing areas. On the other hand, Ceramic restorations have many advantages over resin restorations. Ceramic inlays are reported to have less leakage than resin restoration and to fit better. although marginal fidelity depends on technique and is laboratory dependent. Adhesion of luting resin is more reliable and durable to etched ceramic material than to treated resin composite. In view of color matching, periodontal health. resistance to abrasion, ceramic restoration is superior to resin restorationl. Materials which have been used for the fabrication of ceramic restorations are various. Conventional powder slurry ceramics are also available. Castable ceramics are produced by centrifugal casting of heat-treated glass ceramics. and machinable ceramics are feldspathic porcelains or cast glass ceramics which are milled using a CAD/CAM apparatus to produce inlays (for example, Cered. They may also be copy milled using the Celay apparatus. Pressable ceramics are produced from feldspathic porcelain which is supplied in ingot form and heated and moulded under pressure to produce a restoration. Infiltrated ceramics are another class of material which are available for use as ceramic inlays. An example is $In-Ceram^{\circledR}$(Vident. California, USA) which consists of a porous aluminum oxide or spinell core infiltrated with glass and subsequently veneered with feldspathic porcelain. In the 1980s. the development of compatible refractory materials made fabrication easier. and the development of adhesive resin cements greatly improved clinical success rates. This case report presents esthetic ceramic inlays for posterior teeth.teeth.

  • PDF

OPTIMAL PRESSABLE CERAMIC 금관의 변연형태에 따른 변연적합도와 파절강도에 관한 연구 (Marginal Fidelity and Fracture Strength of OPTIMAL PRESSABLE CERAMIC Crown according to Margin Types)

  • 이주석;김기석
    • 구강회복응용과학지
    • /
    • 제16권1호
    • /
    • pp.13-25
    • /
    • 2000
  • Optimal Pressable Ceramic is one of the all-ceramic restorations with a shaded translucent pressed core and layering porcelains. The purpose of this study was to evaluate the marginal fidelity according to margin types and measurement sites, and to evaluate fracture strength according to margin types. Twenty seven OPC crowns made according to 3 types of cervical finishing lines were used in this study. Marginal gaps were measured before and after cementation. A Steromicroscope(SZ-ST(R), Olympus, Japan) was used to measure the space between the margin of OPC crown and the finishing line of metal model. Marginal gaps were measured at the labial, mesial, lingual and distal site, which were demonstrated in advance. Fracture strength testing was carried out using an Instron(Model M100EC, Mecmesin, England) at a cross head speed of 5 mm/min. All crowns were loaded until catastrophic failures occurred. The result were as follow: 1. In comparison according to variable margin before cementation, the marginal gap were increased in chamfer margin($47.50{\pm}18.39{\mu}m$), $120^{\circ}$shoulder margin ($55.21{\pm}14.4{\mu}m$) and $90^{\circ}$shoulder margin($71.18{\pm}13.30{\mu}m$) in ascending order, and there were significant differences between chamfer margin and $90^{\circ}$shoulder margin, $120^{\circ}$shoulder margin and between $120^{\circ}$shoulder margin and $90^{\circ}$shoulder margin respectively(p<0.05). 2. In comparison according to variable margin after cementation, the gap discrepancies were increased in chamfer margin($60.78{\pm}30.37{\mu}m$), $120^{\circ}$shoulder margin($66.67{\pm}11.18{\mu}m$) and $90^{\circ}$shoulder margin($85.78{\pm}17.23{\mu}m$) in ascending order, but there was significant difference only between chamfer margin and $90^{\circ}$shoulder margin(p<0.05). 3. Labio-lingual points showed a better marginal fidelity than that of proximal point(p<0.05). 4. Chamfer margin($48.76{\pm}8.45kgf$) showed higher fracture strength than $120^{\circ}$ shoulder margin($40.57{\pm}7.90kgf$) and $90^{\circ}$ shoulder margin(32.7.90kgf) (p<0.05), but there was significant difference only between chamfer margin and $90^{\circ}$ shoulder margin(p<0.05).

  • PDF

타이타늄의 표면개질에 따른 도재 결합 특성 (THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION)

  • 최택휴;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.