• Title/Summary/Keyword: Dental Patients

Search Result 4,506, Processing Time 0.028 seconds

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

THE EFFECT OF DISTAL MOVEMENT OF UPPER MOLAR USING THE PENDULUM APPLIANCE (Pendulum 장치의 상악대구치의 원심이동에 대한 효과)

  • Lee, Chang-Seop;Kim, Jae-Gwang;Kang, Dug-Il;Song, Kwang-Chul;Jung, Hyun-Ku;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.488-495
    • /
    • 2001
  • Treatment of class II malocclusions require distalization of maxillary molars into class I relationship. Intraarch distal molar movement techniques have recently assumed an important role in young patients. In this study, the dental and skeletal effects of the pendulum appliance were evaluated by means of cephalometric radiographs. The samples were consisted of 19 patients: 11 females and 8 males, mean age $11.68{\pm}1.52$ years. Measurements were obtained from cephalometric prior to and the day of removal of the pendulum appliance. Treatment changes were analyzed. The following results were obtain. 1. The pendulum appliance produced $2.94{\pm}1.54mm$ distal molar movement with a mean intrusion of $1.17{\pm}0.97mm$, mean period $18.13{\pm}7.95$ weeks. 2. The anchor tooth was $1.34{\pm}1.40mm$ forward movement and $0.48{\pm}0.99mm$ extrusion, and labial tilting of incisors. 3. The angle between palatal plane and mandibular plane increased significantly. 4. There was no significant difference in according to 2nd molar position. 5. Total movement was consisted of 74% distal movement of 1st molar and 26% forward movement of the anchor tooth.

  • PDF

The effect of subject awareness level of oral health on the quality of life for adult patients who visit hospitals and neighborhood clinics in Busan (부산지역 병의원을 내원하는 성인의 구강건강인식수준이 삶의 질에 미치는 영향)

  • Yoon, Hyun-Seo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.505-512
    • /
    • 2017
  • The purpose of this study was to determine the quality of life according to the level of subjective perception as well as to analyze the influencing factors and improve the subjective perception to improve the quality of life. The results of the survey for adult patients in hospitals and neighborhood clinics in the region of Busan for nine months from December 2015 were as follows. Regarding the total symptoms, the women had a score of 1.41, and the younger respondents felt they suffered from no symptoms. An analysis of the quality of life by the general characteristics showed that the respondents who were better educated and had no systemic diseases had a higher score of 54.71 on the OHIP-14. The respondents who were better educated and had no systemic diseases had a higher score of 6.48 when a single item was used to determine their happiness index, and the respondents who were better educated and had no systemic diseases had a higher score of 3.82 when five items were used to rate their happiness index. The factor with the greatest influence on their scores on the OHIP-14 was the total symptoms, followed in order by the happiness index and self-rated oral health status. The variable that exerted the largest influence on the happiness index was the OHIP-14, followed by the self-rated health status, high-school or lower education, and the presence or absence of one or more chronic disease. Therefore, an improvement in the subjective awareness level is required to boost the quality of life, and a variety of health education programs should be prepared to raise the awareness level. In addition, there should be a chance to convey accurate information.

Relationship between disk displacement of temporomandibular joint and dentofacial asymmetry (측두하악관절 원판 변위와 치열 및 안면부 비대칭의 관계에 대한 연구)

  • Nahm, Kyoung-Soo;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.3 s.98
    • /
    • pp.211-222
    • /
    • 2003
  • The purpose of this study was to determine whether there is an association between disk displacement of the Temporomandibular Joint (TMJ) and dentofacial asymmetry In orthodontic patients. The subjects consisted of 60 female orthodontic patients between the ages of 18 and 38 years (mean age 23.3 years) who had visited the Department of Orthodontics at Seoul National University Dental Hospital from January 2000 to April 2002. On the basis of magnetic resonance imaging (MRI) of their bilateral TMJs, the subjects were divided Into four groups'. bilateral normal group (twenty-one persons); disk displacement of right TMJ group (six persons); disk displacement of left TMJ group (nine persons); and disk displacement of both TMJs group (twenty-four persons) Postero-anterior (PA) cephalograms and diagnostic models which had been taken before orthodontic treatment were measured. In the linear measurements, a line connecting the right and left Latero-Orbitale (Lo) represented the horizontal reference line (H). The vertical reference line (V) was constructed as a line bisecting and running perpendicular to H. One-way analysis of variance (ANOVA) was used to test whether the mean values of measurements between groups were significantly different. In addition, Bonferronil's multiple comparison test was performed at a level of 0.05. The results were as follows; 1 In the diagnostic model analysis, the overjet, nght molar relationship, and left molar relationship were significantly different among the four groups. 2. In the PA cephalometric analysis, differences in the right and left vertical position of the lower first molar and Ag were significantly dissimilar among the four groups. 3. If the disk displacement of TMJ was present on one side, the ipsilateral ramus was shorter, resulting in asymmetry in the vertical position of Ag. This study indicated that dentofacial asymmetry might be related to the disk displacement of TMJ.

Clinical Long-term Assessment of Bioactive Glass Graft (Bioactive glass의 장기 임상적 평가)

  • Lee, Hang-Bin;Baek, Jeong-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Choong-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.187-198
    • /
    • 2002
  • The ultimate goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal disease. To achieve periodontal regeneration, various kinds of methods have been investigated and developed, including guided tissue regeneration and bone graft. Bone graft can be catagorized into autografts, allografts, xenografts, bone substitutes. And materials of all types have different biological activity and the capacity for periodontal regeneration, but ideal graft material has not been developed that fits all the requirement of ideal bone graft material. Recently, bioactive glass that has been utilized in plastic surgery is being investigated for application in dental practice. But, there has not been any long-term assessment of bioactive glass when used in periodontal intrabony defects. The present study evaluates the long-term effects of bioactive glass on the periodontal regeneration in intrabony defects of human and the effect of plaqu control on long term treatment results after dividing patients into those who underwent 3-month regular check-up and those who didn't under go regular check-up The clinical effect on 74sites from 17 infrabony pockets of 11 patients were analyzed 36months after treatment. 51 sites which underwent regular check up were classified as the Follow-up group(F/U group), and 23 sites which did not undergo regular check up were classified as Non Follow-up group(Non F/U group). After comparing the probing depth, attachment loss, bone probing depth before and 36months after treatment, the following results could be concluded. 1. The changes of probing pocket depth showed a statistically significant decrease between after baseline and 36 months after treatment in F/U group(1.79${\pm}$0.68mm) and did no show astatistically significant decrease between after baseline and 36months after treatment in Non F/U group(0.61${\pm}$0.54mm) (P<0.05). 2. The changes of loss of attachment showed a statistically significant decrease between after baseline and 36 months after treatment in F/U group(1.44${\pm}$0.74mm) and did no show astatistically significant decrease between after baseline and 36months after treatment in Non F/U group(1.18${\pm}$1.54) (P<0.05). 3. The changes of bone probing depth showed a statistically significant decrease between after baseline and 36 months after treatment in both F/U(1.35${\pm}$0.28) and Non F/U group(0.78${\pm}$0.55mm) (P<0.05). The results suggest that treatment of infrabony defects with bioactive glass resulted in significan reduction of attachment loss and bone probing depth 36months after the treatment. The use of bioactive glass in infrabony defects, combined with regular check-up and proper plaque control generally shows favorable clinical results. This measn that bioactive glass could be a useful bone substitute.

The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion (골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구)

  • Kim, Moon-Hwan;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.389-403
    • /
    • 2008
  • In Angle's Class III malocclusion, which has higher incidence in Korean than Western, depressed midfacial profile with protruded lower lips and mandible may give rise to many functional, esthetic, psychological, social problems. Due to the different malocclusion incidence according to racial differences, many previous studies focused on the relationship between Class II malocclusion and nasal airway obstruction. Previous studies used lateral cephalography which has limitations of 2 dimensional image with projection error and identification error. Therefore, the purpose of this study was to analyze morphologic differences in the nasal airway between normal occlusion and Angle's Class III malocclusion patients using 3-dimensional facial computed tomography. Thirteen normal occlusion(7 men and 6 women) and sixteen skeletal Class III(7 men and 9 women) patients were selected and 3-dimensional facial computed tomography taking was performed. Comparison between two group in volume and sectional area of nasal airway were carried out. The results were followed. 1. In the comparison of absolute nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 2. In the comparison of relative nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 3. In the oropharyngeal space width on frontal and lateral view, the similar tendency was revealed between two groups. 4. In the lateral curvature of nasal airway, the similar tendency was revealed between two groups.

Retrospective study on survival, success rate and complication of implant-supported fixed prosthesis according to the materials in the posterior area (구치부 임플란트 지지 고정성 보철물의 재료에 따른 생존율, 성공률 및 합병증에 대한 후향적 연구)

  • Chae, Hyun-Seok;Wang, Yuan-Kun;Lee, Jung-Jin;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.342-349
    • /
    • 2019
  • Purpose: The purpose of this study was to retrospectively investigate the survival and success rate of implant-supported fixed prosthesis according to the materials in the posterior area. Other purposes were to observe the complications and evaluate the factors affecting failure. Materials and methods: Patients who had been restored implant prosthesis in the posterior area by the same prosthodontist in the department of prosthodontics, dental hospital, Chonbuk National University, in the period from January 2011 to June 2018 were selected for the study. The patient's sex, age, material, location, type of prosthesis and complications were examined using medical records. The KaplanMeier method was used to analyze the survival and success rate. The Log-rank test was conducted to compare the differences between the groups. Cox proportional hazards model was used to assess the association between potential risk factors and success rate. Results: A total of 364 implants were observed in 245 patients, with an average follow-up of 17.1 months. A total of 5 implant prostheses failed and were removed, and the 3 and 5 year cumulative survival rate of all implant prostheses were 97.5 and 91.0, respectively. The 3 and 5 year cumulative success rate of all implant prostheses were 61.1% and 32.9%, respectively. Material, sex, age, location and type of prosthesis did not affect success rate (P>.05). Complications occurred in the order of proximal contact loss (53 cases), retention loss (17 cases), peri-implant mucositis (12 cases), infraocclusion (4 cases) and so on. Conclusion: Considering a high cumulative survival rate of implant-supported fixed prostheses, regardless of the materials, implant restored in posterior area can be considered as a reliable treatment to tooth replacement. However, regular inspections and, if necessary, repairs and adjustments are very important because of the frequent occurrence of complications.

Retrospective study on three-dimensional characteristics of mesiodens using CBCT in pediatric dentistry (치과용 Cone-beam CT를 이용한 상악 정중과잉치의 3차원적 특성에 관한 후향적 연구)

  • Ryu, GiYoun;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.77-94
    • /
    • 2021
  • The purpose of this study was to investigate the three-dimensional characteristics of mesiodens using Cone-beam Computed Tomography(CBCT) and analyze the factors affecting complications and anesthetic methods of extraction. This study evaluated 602 mesiodens of 452 patients who underwent extraction of mesiodens at the department of Pediatric Dentistry in Seoul National University Dental Hospital between 2017 and 2019. The ratio of mesiodens patients over total patient per year was gradually increased over the past 20 years. Mesiodens with labio-palatally horizontal direction while root directing labial were the most common among the mesiodens with horizontal direction. Mesiodens were the most common at the cervical side of the adjacent teeth(37.0%) and mesiodens located in the near-palatal side were observed about 3.83 times higher than the far-palatal side. Most of the mesiodens(82.1%) were in contact with adjacent permanent teeth on all three sides of the CBCT and 46.2% of mesiodens had curved roots. The patient's age, vertical position, presence of complications, and proximity showed a significant difference in the selection of general anesthesia among anesthetic methods. The direction and vertical position of mesiodens had a significant effect on complications. These results provide a better understanding of mesiodens for establishing an accurate diagnosis and treatment plan.