• Title/Summary/Keyword: Dental Models

Search Result 597, Processing Time 0.031 seconds

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns (전부 피개관의 치아 형성 시 축면 경사각에 대한 조사)

  • Kim, Sung-Jin;Pae, Ah-Ran;Woo, Yi-Hyung;Kim, Hyeong-Seob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.21-32
    • /
    • 2010
  • The convergence angle of a prepared tooth is a very important factor in the retention and resistance of a crown restoration. But various intraoral environments and clinician's techniques make it difficult to obtain the ideal inclination. Therefore, in this study, clinical convergence angle of a prepared tooth was investigated. The data was collected from the patient models of prosthodontic residents and the patient models of general practitioners. The images of mesiodistal and buccolingual surfaces were taken with a digital camera to evaluate the convergence angle on 'ImageJ' program. The images were classified according to the criteria (1. Clinician group, 2. Position in the dental arch, 3. The purpose of abutment preparation)and then analyzed. The mean convergence angle of a prepared tooth for Korean clinicians was $15.02^{\circ}$ (${\pm}10.13^{\circ}$). 1. It was significant in the convergence angle between the general practitioner group and the prosthodontic resident group(p<0.05). 2. It was significant between the mesiodistal and buccolingual surface in the the prosthodontic resident group(p<0.05). 3. For the general practitioner group, it was significant when anteriors and premolars were compared with molars(p<0.05). For the prosthodontic resident group, it was significant when anteriors and premolars were compared with molars (p<0.05). 4. When divided into upper and lower arches, for the general practitioner group, it showed significant difference in the buccolingual aspect(p<0.05). Also in the prosthodontic resident group, it showed significant difference in the buccolingual aspect(p<0.05). 5. Dividing left and right sides of the arches, there was no significant difference in the general practitioner group and the prosthodontic resident group(p>0.05). 6. In the general practitioner group, it was significant in the mesiodistal axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). In the prosthodontic resident group, it was significant in the mesiodistal and overall axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). Clinical convergence angle of prepared tooth in Korea was included in agreement with other studies investigating convergence angle that ranged from 10 to 22 degrees, achieved in clinical practice.

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.

Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment (지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 삼차원적 유한요소응력분석)

  • Yun, Mi-Jung;Kim, Chang-Weop;Jeong, Chan-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.51-61
    • /
    • 2011
  • Recently, restoring implants in the esthetically demanding region, zirconia-based materials are widely used due to their superior mechanical properties, accuracies, and esthetics. The purpose of this study was to investigate the load transfer and mechanical stability of zirconia and titanium implant abutments by using the three-dimensional finite element analysis model. The internal conical joint type and external butt joint type implant system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. An load of 250N was applied vertically beside 3mm of implant axis. Stress distribution of zirconia and titanium implant abutment is similar. The maximum equivalent stress of titanium implant abutment is lower than zirconia implant abutment about 15%. Howevere considering a high mechanical strength that exceed those of titanium implant abutment, zirconia implant abutment had similar mechanical stability of titanium implant abutment clinically.

Contemporary Approach to Autotransplantation of Teeth with Complete Roots Using 3D-printing Technology (3D 프린팅 기술을 이용한 치근단 완성 치아의 자가이식에 대한 최신 접근)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan;Cheong, Hyeran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.461-468
    • /
    • 2017
  • Autotransplantation of teeth with complete roots is being increasingly performed for orthodontic treatment or for replacement of unsalvageable teeth, but this procedure has lower survival and success rates than those obtained following transplantation of teeth with incomplete root formation. While previous autotransplantation procedures used only models of the donor tooth and recipient site, surgical guide templates created using 3D-printing technology are now available. They allow shaping of the recipient site in proper direction and to the correct depth, thereby reducing the treatment time and improving the success and survival rates. Herein, we report a case involving autotransplantation of a tooth with complete roots at the site of a congenitally missing permanent tooth using surgical guide templates generated with 3D-printing technology. The procedure resulted in favorable healing of the transplanted tooth.

Factors affecting treatment outcomes in patients with oral lichen planus lesions: a retrospective study of 113 cases

  • Park, Shin-Young;Lee, Hyo-Jung;Kim, So-Hyun;Kim, Sung-Beom;Choi, Yong-Hoon;Kim, Young-Kyun;Yun, Pil-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.213-223
    • /
    • 2018
  • Purpose: Oral lichen planus (OLP) is a chronic oral mucosal disease that has been recognized as an immune condition. The purpose of this study was to evaluate factors affecting the clinical outcomes of topical corticosteroid application on OLP lesions using dexamethasone gargle and ointment. Methods: The charts of patients who were clinically diagnosed with OLP and treated with dexamethasone from July 2003 to August 2017 at the Section of Dentistry of Seoul National University Bundang Hospital were thoroughly evaluated to identify subjects who were suitable for this retrospective study. For each patient, age at the index date, gender, medical history, and dental records related to OLP lesions and dexamethasone treatment were reviewed. Results: In total, 113 of the 225 patients were included in the present study. Among them, 79 patients were female (69.9%) and 34 were male (30.1%), with a mean age of 57.6 years. The average duration of dexamethasone treatment was 4.7 months and the mean follow-up period was 2.24 years. Improvements were observed within 1 year after dexamethasone treatment in most cases, and 17.7% of patients had a new OLP lesion after treatment. New OLP lesions were more frequently gingival than mucosal, although mucosal OLP lesions were more common than gingival OLP lesions in all age groups. In age- and gender-adjusted multivariate logistic regression, a history of malignant disease was found to be a significant factor affecting the formation of new lesions. Gingival OLP lesions and intermittent use of dexamethasone showed near-significant associations. In Kaplan-Meier failure analysis, history of malignancy, menopausal status, age, and the site of the OLP lesion were significant factors affecting clinical outcomes. Conclusions: The treatment outcomes of OLP were significantly influenced by age, history of malignancy, menopausal status, and the site of the OLP lesion, but not by factors related to dexamethasone treatment.

Histological characteristics of newly formed cementum in surgically created one-wall intrabony defects in a canine model

  • Park, Jung-Chul;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.3-10
    • /
    • 2010
  • Purpose: Periodontal regenerative therapies for defects created by severe periodontitis are mainly focused on bone regeneration. Although cementum regeneration needs to be better understood, it is believed to play an important role in periodontal regeneration. The first step toward a full understanding of cementum regeneration is to compare repaired cementum to pristine cementum. This study, which used histological techniques, was designed to focus on cementum regeneration and to compare pristine cementum to repaired cementum after surgical procedures with 8 and 24 week healing periods in a canine model. Methods: Buccal and lingual mucoperiosteal flaps of 10 beagle dogs were surgically reflected to create critical-sized defects. Intrabony one-wall defects, of which dimension is 4 mm width and 5 mm depth, were made at the distal aspect of mandibular second premolars and the mesial aspect of mandibular fourth premolars in the right and left jaw quadrants. Animals were sacrificed after 8 and 24 weeks post-surgery for histological specimen preparation and histometric analysis. Results: The repaired cementum was composed mostly of acellular cementum and cellular mixed fiber cementum and was thicker in the apical area than in the coronal area. The acellular cementum of the supracrestal area appeared to be amorphous. The newly formed cellular cementum was partially detached from the underlying circumpulpal dentin, which implied a weak attachment between new cementum and dentin, and this split was observed to a lesser extent in the 24 week group than in the 8 week group. The vertical height of the repaired cementum was greater in the 24 week group than in the 8 week group. Conclusions: Within the limitations of this study, we can conclude that repaired cementum after root planing was mainly acellular cementum and cementum tissue that matured to a shape similar to pristine cementum as the healing progressed from 8 to 24 weeks.

Role of the Vestibular and Medullary Reticular Neuclei for the Motor Evoked Potentials in Rats (흰쥐의 운동유발전위에 대한 전정신경핵과 연수망상핵의 역할)

  • Lee, Moon-Young;Lee, Sung-Ho;Kim, Jae-Hyo;Park, Byung-Rim;Kim, Min-Sun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.6
    • /
    • pp.603-611
    • /
    • 1997
  • The motor evoked potentials (MEPs) have been advocated as a method of monitoring the integrity of spinal efferent pathways in various injury models of the central nervous system. However, there were many disputes about origin sites of MEPs generated by transcranial electrical stimulation. The purpose of present study was to investigate the effect of major extrapyramidal motor nuclei such as lateral vestibular nucleus (VN) and medullary reticular nucleus (mRTN) on any components of the MEPs in adult Sprague-Dalwey rats. MEPs were evoked by electrical stimulation of the right sensorimotor cortex through a stainless steel screw with 0.5mm in diameter, and recorded epidurally at T9 - T10 spinal cord levels by using a pair of teflon-coated stainless steel wire electrodes with 1mm exposed tip. In order to inject lidocaine and make a lesion, insulated long dental needle with noninsulated tips were placed stareotoxically in VN and mRTN. Lidocaine of $2{\sim}3\;{\mu}l$ was injected into either VN or mRTN. The normal MEPs were composed of typical four reproducible waves; P1, P2, P3, P4. The first wave (P1) was shown at a mean latency of 1.2 ms, corresponding to a conduction velocity of 67.5 m/sec. The latencies of MEPs were shortened and the amplitudes were increased as stimulus intensity was increased. The amplitudes of P1 and P2 were more decreased among 4 waves of MEPs after lidocaine microinjection into mRTN. Especially, the amplitude of P1 was decreased by 50% after lidocaine microinjection into bilateral mRTN. On the other hand, lidocaine microinjection into VN reduced the amplitudes of P3 and P4 than other MEP waves. However, the latencies of MEPs were not changed by lidocaine microinjection into either VN or mRTN. These results suggest that the vestibular and reticular nuclei contribute to partially different role in generation of MEPs elicited by transcranial electrical stimulation.

  • PDF

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS (골내 임플랜트의 종류에 따른 광탄성 응력 분석)

  • Chung Chae-Heon;Chang Doo-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

Quantitative evaluation and affecting factors of post-treatment relapse tendency (교정치료 후 나타나는 재발 경향에 대한 정량적 평가와 영향을 미치는 요소에 대한 연구)

  • Son, Woo-Sung;Cha, Kyung-Suk;Chung, Dong-Hwa;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.41 no.3
    • /
    • pp.154-163
    • /
    • 2011
  • Objective: The purpose of this study was to quantitatively evaluate relapse tendency after orthodontic treatment and determine the contributing factors by using the American Board of Orthodontics objective grading system (ABO-OGS). Methods: The subjects were 80 patients with more than 2 years of retention period after completing orthodontic treatment at the dental hospitals of Busan University, Kyunghee University, and Dankook University. The posttreatment (T2) and post-retention (T3) ABO-OGS measurements were analyzed in relation to age, gender, Angle's classification, extraction, retention period, and pretreatment condition (initial peer assessment rating (PAR) index, T1) by multiple regression analysis. Results: Among the 7 ABO-OGS criteria, alignment worsened but occlusal contact and interproximal contact improved in T3, but not in T2 ($p$ < 0.01). The 4 other criteria showed no significant differences. Multiple regression analysis showed that alignment, occlusal relationship, overjet, and interproximal contact were significant linear models, but with a low explanation power. Age, gender, Angle's classification, extraction, retention period, and pretreatment condition (initial PAR index, T1) had little influence on the ABO-OGS changes between T3 and T2. Conclusions: An orthodontist's understanding of posttreatment relapse tendency can be useful in diagnosis and during patient consultation.