• 제목/요약/키워드: Dental Laboratory Technology

검색결과 689건 처리시간 0.021초

임플란트 국소의치 금나사의 3차원 유한요소법 접촉응력 분석 (3D Dimensional Finite Element Analysis of Contact Stress of Gold Screws in Implant Partial Denture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.303-312
    • /
    • 2013
  • Purpose: In this research, non-linear three dimensional finite element models with contact elements were constructed. For the investigations of the distributions of contact stresses, 3 units fixed partial dentures model were studied, especially on the interface of the gold screw and cylinder, abutment screw. Methods: 3 types of models were constructed ; the basic fixed partial denture in molar region with 3 units and 3 implants, the intermediate pontic fixed partial denture model with 3 units and 2 implants, and the extension pontic fixed partial denture model with 3 units and 2 implants. For all types, the external loading due to chewing was simulated by applying $45^{\circ}$ linguo-buccal loading of 300 N to the medial crown. For the simulation of the clamping force which clinically occurs due to the torque, thermal expansion was provided to the cylinder as a preload. Results: Under 300 N concentrated loading to the medial crown, the maximum contact stress between abutment screw and gold screw was 86.85~175.86MPa without preload, while the maximum contact stress on the same area was 25.59~57.84MPa with preload. Conclusion: The preloading affected the outcomes of the finite element stress analysis. Reflecting the clinical conditions, the preloading conditions should be considered for other practical study utilizing FEA. For the study of the contact stresses and related motions, various conditions, such as frictional coefficient changes, gap between contact surfaces, were also varied and analyzed.

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동 (Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti)

  • 이승우;김윤종;류재경;박중근;김원수;김택남
    • 한국재료학회지
    • /
    • 제15권9호
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.

리튬디실리케이트 글라스-세라믹의 반복 성형이 색 안정성에 미치는 영향 (The effect of repeat processing on the color stability of lithium disilicate glass-ceramic)

  • 전병욱
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.175-180
    • /
    • 2021
  • Purpose: This study investigates the effect of repeated use of lithium disilicate glass-ceramics on color stability. Methods: In this study, 2 types of lithium disilicate glass-ceramics were used and they were divided into 4 groups after 1st, 2nd, 3rd, and 4th heat pressing. The L*, a*, and b* values of all specimens were measured using the VITA Easyshade Advance 4.0. These values was used to determine the ∆E value and transparency. IBM SPSS Statistics ver. 24.0, a statistical significance level of 0.05 and one-way ANOVA were used for all data. Results: In all groups, the L* and b* values were the lowest in the specimens subjected to the 4th heat pressing and the corresponding a* value was the highest. All specimens showed ∆E values of ≤3.3, indicating color changes that were not visible with the naked eye, and the color difference increased with the number of repeated heat pressing. The transparency of all specimens decreased as the number of repeated uses increased. Conclusion: According to the number of repeated heat pressing, the color difference of Rosetta SP (HASSBIO) was larger than that of IPS e.max Press (Ivoclar Vivadent), but it was clinically acceptable in all groups. Moreover, transparency decreased as the number of heat presses increased in all groups. According to the above findings, the lithium disilicate glass-ceramic has high color stability due to repeated heat pressing, implying that it can be used in clinical settings regularly.

Chitosan/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies

  • Zhang, Ting;Zhang, Xinwei;Mao, Mengyun;Li, Jiayi;Wei, Ting;Sun, Huiqiang
    • Journal of Periodontal and Implant Science
    • /
    • 제50권6호
    • /
    • pp.392-405
    • /
    • 2020
  • Purpose: Titanium implants are widely used in the treatment of dentition defects; however, due to problems such as osseointegration failure, peri-implant bone resorption, and periimplant inflammation, their application is subject to certain restrictions. The surface modification of titanium implants can improve the implant success rate and meet the needs of clinical applications. The goal of this study was to evaluate the effect of the use of porous titanium with a chitosan/hydroxyapatite coating on osseointegration. Methods: Titanium implants with a dense core and a porous outer structure were prepared using a computer-aided design model and selective laser sintering technology, with a fabricated chitosan/hydroxyapatite composite coating on their surfaces. In vivo and in vitro experiments were used to assess osteogenesis. Results: The quasi-elastic gradient and compressive strength of porous titanium implants were observed to decrease as the porosity increased. The in vitro experiments demonstrated that, the porous titanium implants had no biological toxicity; additionally, the porous structure was shown to be superior to dense titanium with regard to facilitating the adhesion and proliferation of osteoblast-like MC3T3-E1 cells. The in vivo experimental results also showed that the porous structure was beneficial, as bone tissue could grow into the pores, thereby exhibiting good osseointegration. Conclusions: Porous titanium with a chitosan/hydroxyapatite coating promoted MC3T3-E1 cell proliferation and differentiation, and also improved osseointegration in vitro. This study has meaningful implications for research into ways of improving the surface structures of implants and promoting implant osseointegration.

Oral Hygiene Controllability and Personality Type Test (MBTI)

  • Park, Hye Sook
    • Journal of Oral Medicine and Pain
    • /
    • 제39권1호
    • /
    • pp.15-21
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the relationship between personality type and oral hygiene controllability. Methods: Four hundred eighty-two college students in Gyeonggi-do completed the Myers-Briggs type indicator (MBTI) and a questionnaire and collected data were analyzed by SAS 9.2 program. Results: Compared to extroverted subjects, a significantly increased percentage of introverted subjects demonstrated oral malodor and stress (p<0.05). Tongue coating and stress seemed to occur the most frequently in intuition-feeling (NF) type, while oral malodor seemed to occur the most frequently in sensation-feeling (SF) type among four fuctional types. Tongue coating and stress seemed to occur the most frequently in NF type, while oral malodor seemed to occur the most frequently in sensation-perceiving (SP) type among four temperaments. Significantly increased mean scales of tongue scraping index and oral hygiene controllability index were found for extroverts (p<0.05). Mean scales of tooth brushing index and oral hygiene controllability index appeared to be the highest in NF type among four fuctional types. Mean scales of tongue scraping index and oral hygiene controllability index appeared to be the highest in sensation-judging (SJ) type among four temperaments. Conclusions: Oral hygiene controllability was associated with personality type and it is necessary to develop oral health education program considering personality type.

Quantitative Review of Oral Cancer Research Output from Pakistan

  • Khan, Zohaib;Muller, Steffen;Ahmed, Shahzad;Tonnies, Justus;Nadir, Faryal;Samkange-Zeeb, Florence
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권11호
    • /
    • pp.4733-4739
    • /
    • 2015
  • Background: Oral cancer is the most common cancer among men and second only to breast cancer among women in Pakistan. For the effective control and prevention of oral cancer, Pakistan needs to recognize the importance of research and generation of the evidence-base which can inform policy making and planning and implementation of intervention programs. The objective of this review was to quantify oral cancer research output in Pakistan. Materials and Methods: A systematic electronic search in "Medline", "ISI-Web of Science" and "Pakmedinet", supplemented by a Google search, was carried out in January and February, 2014, to identify literature from Pakistan relevant to oral cancer. The selection of publications for the review was carried out according to preset criteria. Data were recorded and analyzed using Microsoft Excel. Results: A total of 166 publications comprising 62 case series, 36 cross sectional, 31 case control, 10 basic laboratory research, eleven reviews and two trials, were included in this review. Some 35 % of the publications focused on risk factors for oral cancer. COMSATS Institute of Information Technology was the institution with the highest contribution. Conclusions: There is a lack of research in the field of oral cancer research in Pakistan. Focused efforts should be put in place to improve both quality and quantity of oral cancer research in the country.

장애노인의 특성과 장애로 인한 추가소요 의료비 지출간의 관련성 연구 (A Study of the Relations between Characteristics of the Elderly with Disabilities and Extra Health Care Costs Caused by Disability)

  • 이종화;정현식;황홍구;김성우
    • 보건의료산업학회지
    • /
    • 제8권4호
    • /
    • pp.209-220
    • /
    • 2014
  • This study found a relationship between the characteristics of the elderly with disabilities and extra health care monthly costs caused by disability and suggests methods for effectively managing health care spending of the elderly with disabilities. This study used data from the 2011 Survey on the Disabled conducted by the Ministry of Health and Welfare and the Korea Institute for Health and Social Affairs. The results of the analysis indicate that the relations between the socio-demographic characteristics of the elderly with disabilities and extra health care monthly costs caused by disability of the elderly are influenced by factors such as gender, age, members of the household, average monthly income and type of health insurance. Elderly people with disabilities spend too much for their medical care. To solve this problem, the government needs to find a variety of policy approaches to improve administrative procedure, establish a medical delivery system and enhance health care services.

생체용 Ti-15Sn계 합금의 내식성 및 기계적 성질에 관한 연구 (A Study on Corrosion Resistance and Mechanical Properties of Ti-15Sn System Alloys for Medical Implants)

  • 이도재;김대환;박효병;이경구
    • 한국주조공학회지
    • /
    • 제20권3호
    • /
    • pp.208-215
    • /
    • 2000
  • The mechanical properties and corrosion resistance of Ti alloys for medical implants have been investigated. Ti, Ti-15Sn-4Nb and Ti-15Sn-4Nb-2Zr alloys were melted in arc furnace and the corrosion resistance of Ti alloys was evaluated by anodic polarization test. The microstructure and mechanical properties of Ti alloys were analysed by optical microscope, hardness and tensile tester. The tensile strength of the pure-Ti improved by addition of Sn and Nb and Ti-15Sn-4Nb alloy showed better Rockwell hardness compared with pure Ti. However, there was no significant difference in corrosion resistance between thoseTi-alloys made of Pure-Ti and Ti-15Sn-4Nb alloy. The passive films on the Ti-15Sn-4Nb alloy in air atmosphere consisted of $TiO_2$, SnO and NbO as demonstrated by X-ray photoelectron spectroscopy(XPS)

  • PDF