• Title/Summary/Keyword: Dental Laboratory Technology

Search Result 686, Processing Time 0.022 seconds

Effect of support thickness on the adaptation of Co-Cr alloy copings fabricated using selective laser melting (출력 지지대 두께가 선택적 레이저 용융법으로 제작된 금속 하부구 조물 적합도에 미치는 영향)

  • Jae-Hong Kim;Se-Yeon Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.3
    • /
    • pp.67-73
    • /
    • 2023
  • Purpose: This in vitro study aimed to evaluate the clinical acceptability of precision of fit of the support thickness of Co-Cr alloy copings fabricated using selective laser melting (SLM). Methods: Thirty dental stone models of maxillary left molar abutments were manufactured, images were taken using a scanner, and a computer-aided design program was used to design the form of a conventional metal ceramic crown coping. Overall, 30 single copings were made from Co-Cr alloy using SLM and divided into three support radius groups (0.1, 0.25, and 0.35 mm) of 10 for each. Digitized data were superimposed with three-dimensional inspection software to quantitatively obtain the machinability of a ceramic crown coping, and visual differences were confirmed using a color map. The root mean square values of the ceramic crown coping group were statistically analyzed using one-way analysis of variance (α=0.05). Results: The precision of fit was superior with 0.25 mm compared with 0.1 mm and 0.35 mm, and the results exhibited significant differences (p<0.05). All specimens showed that various support thicknesses did not exceed the clinically permitted value of 120 ㎛, which mean that more than 0.1 mm and 0.35 mm of support radius for SLM was adequate. Conclusion: The support thickness of Co-Cr alloy restoration fabricated using SLM is shown to affect the adaptation.

A Study on Clinical Crown Angulation and Inclination of Females in the Twenties with Normal Occlusion (20대 여성 정상교합자에서 임상치관의 순·설측 경사도와 근·원심 경사도에 관한 연구)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.415-424
    • /
    • 2013
  • Purpose: This study is to present a standard value for clinical crown angulation and inclination required in laboratory process and see if the value can be used for actual laboratory process. Methods: In order to find out a standard value for clinical crown angulation and inclination, this study made a study model of normal occlusion of 21 females in twenties. The clinical crown angulation and inclination of both six-maxillary and six-mandibular anterior teeth are measured by Set-up Model Checker. From the measured value above, the mean and standard deviation of the twelve teeth are obtained, and then the mean of the teeth between right and left side is calculated. Results: Each clinical crown angulation of maxillary central incisor, lateral incisor, and canine is like this; $1.0^{\circ}{\pm}1.3^{\circ}$, $3.0^{\circ}{\pm}1.3^{\circ}$, and $5.0^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.6^{\circ}{\pm}1.1^{\circ}$, $1.5^{\circ}{\pm}1.1^{\circ}$, and $4.1^{\circ}{\pm}1.1^{\circ}$. Each clinical crown inclination of maxillary central incisor, lateral incisor, and canine is like this; $6.1^{\circ}{\pm}1.8^{\circ}$, $4.5^{\circ}{\pm}1.9^{\circ}$, and $-6.2^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.3^{\circ}{\pm}1.5^{\circ}$, $0.3^{\circ}{\pm}1.8^{\circ}$, and $-7.5^{\circ}{\pm}1.8^{\circ}$. Conclusion: As the result, the mean value for clinical crown angulation and inclination can be referred to actual laboratory process. However, the mean value is different from those of the precedent study and an unsatisfied one for adopting the standard value.

A Study of the Department of Dental Hygiene and Dental Laboratory Technology Student's Demand for the Credit Bank System (학점은행제(치위생과, 치기공과)를 이용한 학사학위 취득에 관한 요구도 조사)

  • Yu, Ji-Su
    • Journal of dental hygiene science
    • /
    • v.7 no.3
    • /
    • pp.153-159
    • /
    • 2007
  • To investigate requirements for the process of credit bank system in life-long education institutions attached to colleges, this research was conducted with seniors at the departments of dental hygiene and dental laboratory technology, in the health line of the specific College from March 26 to April 15, 2007, followed by analysis using an SPSS/WIN 12.0 program, obtaining the following results. 1. 89.7% of the respondents had a plan to take a bachelor's degree and 56.1% of whom had such a plan for the purpose of personal development (p<0.05). 2. 73.5% of the respondents preferred the credit bank system in a lifelong education institution attached to a college to take a bachelor's degree. 3. 34.8% presented the greatest advantage of taking a bachelor's degree through the credit bank system that they could take a degree in a short period of time while 33.8% presented the most serious disadvantage that they might low social recognition. 4. As for requirements for the process of operating the credit bank system, 80.3% regarded required subjects for the major as appropriate basic ones. 79.9% regarded it as proper that filling more than 20 credits made it possible to take a degree. 5. As directions for improving the system, it was found that the students was thinking that strict academic record management is needed, and the degrees from the system must be recognized equally to those in regular colleges, social awareness in those degrees should be enhanced, and also credits assigned to cultural subjects should be reduced, and the limitation in the number of credits being able to be obtained in one center should be removed.

  • PDF

A study on the fitness of the margin to recast with a Ni-Cr alloy for full cast crown (전부주조관용 Ni-Cr 합금 재주조에 따른 변연의 적합도에 대한 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • This experimental study was to determine the fitness on each cervical margin of recast using crown base metal alloy. The alloy used in this experimental study was a Ni-Cr alloy(Wirolloy, Bego, Germany) for the fabrication of full cast crown prosthesis. Twenty-five copings were divided into the five groups. And the group A, B, C, D and E were cording successively according to the frequency of recast to five times. Each specimen was recasted without adding new metal. The experimental results were as follows: 1. The group A and B showed good fitness had subtle differences in each cervical margin adaptation, in other words, the mesio and disto cervical margin showed worse adaptation than the bucco and linguo cervical margin. 2. The group C got good fitness in bucco and linguo cervical margins, but the mesio and disto cervical margin showed inaccurate fitness. And I could not get good casting bodies without adding new metal. 3. The group D and E showed bad fitness for each cervical margin. Therefore the group D and E lost its function as a dental restoration.

  • PDF

Research for The Comparing Test of the Fracture Strength According to the Heat Curing Method in the Denture Base Resin (의치상용 열중합 레진의 Curing방법에 따른 파절 강도의 비교실험연구)

  • Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • For this study, self curing resin and heat curing resin used for existing usual resin denture base in the denture industry were chosen by manufacturer. Curing tests for 30-minute, I-hour, 2-hour and 3-hour were conducted to know the strength of the resins and conduct analysis to get other necessary information. The results obtained are as follows: 1. Heat curing resins show a little differences among the manufacturers. However 30-minute curing resin shows great difference as shown in the fracture strength test. 2. The effect from the granularity of the resins on the fracture strength was found insignificant which means there is no difference between coherence and strength. 3. To summarize the results from each time level, the longer the time is, the more the minute cracks on the surface, which is the cause of reduced strength. From this test, it was identified that in making the denture base for patients in dental clinics, 30-minute curing is most efficient and effective in reducing discoloration and monomers, although long-time curing has been considered to be the principal.

  • PDF

Satisfaction and demand of the New Prosthesis Treatment according to the oral health condition of the geriatric patient in Daejeon City (대전지역 노인환자의 구강보건실태에 따른 치과보철의 만족도와 요구도)

  • Jung, Jae-Kwan;Lee, Su-Ok
    • Journal of Technologic Dentistry
    • /
    • v.31 no.3
    • /
    • pp.59-66
    • /
    • 2009
  • In this study 240 geriatric patients, aged 60 year and over were evaluated using a questionnaire and oral examination for their oral status, demand and satisfaction of prosthesis treatment. 1. The single main complaint was regarding from the existing removable prosthesis. When the complaints were catagorized into larger groups, complaints regarding existing prosthesis were 32% and followed by 30% in caries and endodontic problems. 2. DMFT index woman appeared the man the age when will increase more highly recording where highly and considered statistically. 3. According to the result from questionnaire, 48% of patients wearing removable prosthesis and 43% with fixed prosthesis were not satisfied with existing prosthesis. Thirty-seven percentages of patients were not satisfied with aesthetics and unable to chew food properly. 4. Thirty-nine percentage of patients were wearing removable prosthesis. More complete dentures were found on maxilla and partial dentures on mandible. 5. Seventy-seven percentage of patients requested for new prosthesis and the majority of these patients had complaints of difficulties in chewing and discomfort.

  • PDF

Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns (자연치와 도재관에 대한 색조선택의 동일성)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

A study on the design wax up technique for mandibular molar occlusion surface (하악구치 교합면의 design 조각법에 관한 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.107-126
    • /
    • 2002
  • The first function of occlusion is mastication. Therefore the functional restoration of occlusal surface is very important. The restoration of occlusal surface is three method as wax bite technique, F.G.P. technique, cone technique. Many dental technician is using compound method. I am using compound method of wax bite technique and cone technique. I have knew common point on each teeth during I have waxing up wax pattern. So I studied on the design waxup technique for mandible molar occlusion. The results of the study were as follows; 1. The dam wax up method can restore axial contour of teeth very easy and make short working time of wax pattern. 2. The height of dam must be same with cusp of adjacent teeth. 3. Automatically the contour of tooth is appeared if the contour of dam is relationship with cuspid line of adjacent teeth. 4. The height of contour of buccal, lingual surface is formed natural curve to add fluid wax by gravitation. 5. The development groove of mandible first premolar is appeared V form. 6. The development groove of mandible second premolar is appeared Y form. 7, The development groove of mandible first molar is appeared M form. 8. The development groove of mandible second molar is W form. 9. The embrasure is formed to carve around contact point area as round convex. It affects to axial form of tooth. 10. The buccal, lingual groove of molar is formed parallel with direction of teeth arrangement.

  • PDF

Composition of nickel-chromium alloy on the centrifugal casting and the influence of quantitative of oxides on the casting temperature (원심 주조한 니켈-크롬 합금의 성량 변화 및 주조 온도에 따른 산화물 측정)

  • Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.361-368
    • /
    • 2012
  • Purpose: The aim of this study was to analysis the composition on the centrifugal casting and the oxide on the casting temperature. Methods: The nickel based alloy were used in this study. Wax pattern specimens (10*10*2) were invested with phosphate-bonded investment in metal rings, the liquid/powder ratio and overall burn-out schedules for these investments were followed in accordance with the manufacturer's instructions. After casting, the alloy specimens were evaluated as regards composition(EPMA). The casting temperatures were as follows: $1400^{\circ}C$ and $1700^{\circ}C$. The quantitative analysis of oxides were scanning electron microscope(SEM), energy dispersive spectroscopy(EDS) and line scanning. Results: Nearer the injection lines showed that there is a large amount of nickel. Quantitative of oxides of Ni-Cr alloy cast from $1400^{\circ}C$ is lager than Ni-Cr alloy cast from $1700^{\circ}C$. Conclusion: Casting when using a centrifugal casting machine centrifugal force affects the composition of the alloy. The higher the temperature, the amount of oxide that is generated many.

Effect Boron and Silicon on Various Properties of Dental Cobalt-Chromium Alloys (치과용 Co-Cr 합금의 제성질에 미치는 Boron과 Silicon의 영향)

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.119-132
    • /
    • 1992
  • This paper aims to investigate the effect of B and Si upon the mechanical properties, microstructure and corrosion resistance of Co-Cr base alloy. Ten groups of alloy ingot ingot with various contents of B and Si were remelted by high frequency electrical induction furnace and cast into tensile specimen of ADA Specification No. 14 Tensile and hardness test were carried out by Amsler and Rockwell hardness tester(R-30N), respectively. The microstructures of specimen were observed by SEM. The results obtained are summarized as follows : 1. As B content is increased, tensile strength, yield strength and Rockwell hardness number(R-30N) are also increased significantly, while the elongation is decreased significantly. 2. As Si contect os increased, no significant chang in tensile strength is noticed, yield strength is slightly decreased, but Rockwell hardness number(R-30N) is moderately in creased, Elongation marks maxium value with 1% Si content while with more than 1% Si it is decreased. 3. As B content is increased corrosion resistance is decreased and is at best with 1.5% B content. Corrosion resistance is increased with the increase of Si content and the alloys with Si over 3.0% showed corrosion resistance. 4. As B content increased, precipitates are increased in number at grain boundaries. The grain size tends to become coarse with the increase of Si content. 5. Co rich-Cr alloy is present through matrix whereas at the grain boundaries Cr base precipitates are primarily formed.

  • PDF