• 제목/요약/키워드: Dental Impression Materials

검색결과 148건 처리시간 0.021초

시판 폴리비닐실록산 인상재의 물성에 관한 비교연구 (Comparative study on properties of commercial polyvinyl siloxane impression materials)

  • 강재경
    • 한국치위생학회지
    • /
    • 제1권2호
    • /
    • pp.171-180
    • /
    • 2001
  • The purpose of this study was to compared with the properties of commercial polyvinyl siloxane impression materials on the Korean product and the other country one. The materials used in this study were 5 hydrophilic polvinyly siloxane impression materials of light body automixing type (Perfect-F, Handae Chemical, Korea; Examix, GC, Japan; Contrast, VOCO, Germany; Express, 3M, U.S.A; Extrude, Kerr, U.S.A.). Specimens of each impression material were fabricated from a mold with dimensions identical to that specified in ASTM D624-91 and were subjected to tensile lode at 500 mm/min until failure for tear strength. Properties of consistency, strain in compression, recovery from deformation, detail reproduction and linear dimensional change were tested according to the testing methods of the ISO specification no.4823(1992). From this study, the follow ing results were obtained 1. The tear strength values were high ET(3.4kN/m), EP(3.4kN/m), PF(3.0kN/m), CT(3.0kN/m), but the lowest was EM(2.2kN/m)(p<0.05). 2. In the consistency, CT(47 mm) had the highest value, followed by PF(42.1 mm), ET(41.2 mm), and EM(39.6 mm), EP(39.2 mm)(p<0.05). It means more flow that the consistency value is high. 3. The strain in compression values were high followed by EM(5.8%), PF(52%), CT(4.6%), ET(4.1%), EP(2.9%)(p<0.05). 4. In the recovery from deformation, ET(99.95%) and PF(99.90%) had the highest value, followed by EP(99.75%), EM(99.74%) without statistical signification, CT(99.64%) had the lowest value(p<0.05). 5. Detail reproduction reappeared to line $20{\mu}m$ all products. 6. The linear dimensional change was a little shrinked all products. and there were not statistical signification (p>0.05). All products were satisfied the ISO specification.

  • PDF

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • 대한치과의사협회지
    • /
    • 제41권1호통권404호
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구 (WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS)

  • 조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF

임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용 (Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner)

  • 박지만;박은진;허성주
    • 대한치과의사협회지
    • /
    • 제52권6호
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

Accuracy of several implant bite registration techniques: an in-vitro pilot study

  • Park, Do-Hyun;Park, Ji-Man;Choi, Jae-Won;Kang, Eun-Sook;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.341-349
    • /
    • 2017
  • PURPOSE. This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS. Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS. The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION. Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.

고무 인상채득시 지대치재료와 표면처리법의 영향 (THE EFFECT OF ABUTMENT MATERIALS AND SURFACE TREATMENT ON RUBBER BASE IMPRESSION)

  • 정도진;양홍서
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.146-156
    • /
    • 2001
  • The purpose of this study was twofold. One was to evaluate the wettability of 4 elastomeric impression materials on tooth and different kinds of filling materials. The other was to identify the effect of topical surfactants sprayed on the surface of each impression. The elastomeric impression mate rials used in this experimental study were one polyether(Impregum F) and three polyvinyl siloxanes(Provil novo, Zerosil, Imprint). The abutments were prepared for 3/4 crown or onlay on the extracted human first molar. The filling materials used in this study for the duplication of prepared abutment were composite resin, amalgam, and casting metal. Impression was taken by manufacturer's recommendations and the number of voids on the impression surface was counted. The topical surfactants were Spannex $II^{(R)}$ and $Cohere^{(R)}$. The wettability was evaluated by comparing the number of voids between non-treated group and treated groups. The results were as follows : 1. $Zerosil^{(R)}$ showed the least number of voids on the impression surface. The number of voids increased in order of Provil $novo^{(R)}$, Impregum $F^{(R)}$, and $Imprint^{(R)}$. 2. Impregum $F^{(R)}$ and $Zerosil^{(R)}$ showed the least number of voids on the surface of dental stone master cast. The number is inclosed in order of Provil $novo^{(R)}$ and Imprint 3. When abutment material is tooth, the number of voids on the surface of master cast was smallest compared with that of other abutment materials. The number of voids increased in order of casting metal, amalgam and composite resin 4. The number of voids on the surface of the dental stone master cast was smallest when Spannex $II^{(R)}$ was used, followed by $Cohere^{(R)}$ treated group and non-treated group. These results suggest that the difference in wettability caused by the types of rubber base impression materials as well as abutment materials can affect the number of voids. And the use of topical surfactant for rubber base impression materials can improve the wettability of the materials and enhance the accurate master cast which has fewer surface voids.

  • PDF

계면활성제와 소포제가 실리콘 고무인상재의 물성에 미치는 영향 (Effect of Surfactant and Anti-foaming Agent on the Properties of Silicone Rubber Impression Material)

  • 김경남;조리라;오영일;강승경;정경호
    • Elastomers and Composites
    • /
    • 제36권2호
    • /
    • pp.102-110
    • /
    • 2001
  • Nonylphenoxy poly(ethylene) ethanol homologues, caster oil poly(ethylene) ethanol homo-logues 및 sodium perfluoroalkyl carboxylates의 세 가지 종류 계면활성제를 사용하여 고무인상재의 젖음성 향상 연구를 수행한 결과 불소 관능기가 도입된 sodium perfluoroalkyl carboxylates 계면활성제의 경우 다른 계면활성제를 사용한 경우에 비해 고무인상재의 초기 표면에너지 값은 유사했으나 평형상태에 이른 후의 표면에너지 값이 낮아 치아와의 젖음성이 가장 우수한 것으로 나타났다. 또한, 수소가스의 발생을 억제시키고 미세부 재현성을 높이기 위해 소포제를 사용한 결과 젖음성이 향상된 sodium perfluoroalkyl carboxylates를 포함한 조성에 소포제를 첨가할 경우 인열물성이 약 40% 이상 증가하였는데, 이는 소포제가 고무인상재 내부의 반응으로 생성되는 수소가스의 발생을 억제하기 때문이다. 따라서, 소포제는 고무인상재의 표면특성에는 크게 영향을 미치지 않으면서 인상재 내부에 발생되는 기포를 효과적으로 억제 혹은 제거하여 고무 인상재의 기계적물성을 향상시킴을 알 수 있었다.