• 제목/요약/키워드: Dental Implantation

검색결과 265건 처리시간 0.031초

Effects of nerve cells and adhesion molecules on nerve conduit for peripheral nerve regeneration

  • Chung, Joo-Ryun;Choi, Jong-Won;Fiorellini, Joseph P.;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권3호
    • /
    • pp.191-198
    • /
    • 2017
  • Background: For peripheral nerve regeneration, recent attentions have been paid to the nerve conduits made by tissue-engineering technique. Three major elements of tissue-engineering are cells, molecules, and scaffolds. Method: In this study, the attachments of nerve cells, including Schwann cells, on the nerve conduit and the effects of both growth factor and adhesion molecule on these attachments were investigated. Results: The attachment of rapidly-proliferating cells, C6 cells and HS683 cells, on nerve conduit was better than that of slowly-proliferating cells, PC12 cells and Schwann cells, however, the treatment of nerve growth factor improved the attachment of slowly-proliferating cells. In addition, the attachment of Schwann cells on nerve conduit coated with fibronectin was as good as that of Schwann cells treated with glial cell line-derived neurotrophic factor (GDNF). Conclusion: Growth factor changes nerve cell morphology and affects cell cycle time. And nerve growth factor or fibronectin treatment is indispensable for Schwann cell to be used for implantation in artificial nerve conduits.

Clinical evaluation of a collagen matrix to enhance the width of keratinized gingiva around dental implants

  • Lee, Kang-Ho;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • 제40권2호
    • /
    • pp.96-101
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of collagen matrix with apically positioned flap (APF) on the width of keratinized gingiva, comparing to the results of APF only and APF combined with free gingival graft (FGG) at the second implant surgery. Methods: Nine patients were selected from those who had received treatments at the Department of Periodontics, Chosun University Dental Hospital, Gwangju, Korea. We performed APF, APF combined with FGG, and APF combined with collagen matrix coverage respectively. Clinical evaluation of keratinized gingival was performed by measuring the distance from the gingival crest to the mucogingival junction at the mid-buccal point, using a periodontal probe before and after the surgery. Results: The ratio of an increase was 0.3, 0.6, and 0.6 for the three subjects in the APF cases, 3, 5, and 7 for the three in the APF combined with FGG case, and 1.5, 0.5, and 3 for the three in the APF combined with collagen matrix coverage case. Conclusions: This study suggests that the collagen matrix when used as a soft tissue substitute with the aim of increasing the width of keratinized tissue or mucosa, was as effective and predictable as the FGG.

Evaluation on the efficacy and safety of calcium metaphosphate coated fixture

  • Cho, In-Ho;Lee, Jae-Hoon;Song, Young-Gyun;Kim, Young-Mi;Jeon, So-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.172-178
    • /
    • 2013
  • PURPOSE. The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures. MATERIALS AND METHODS. This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used. RESULTS. In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants. CONCLUSION. One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.

Implant Placement Using Palatal Bone in Patients with Severe Maxillary Alveolar Bone Defect: Case Series Study

  • Yu, Han-Chang;Yun, Pil-Young;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • 제13권2호
    • /
    • pp.73-80
    • /
    • 2020
  • Purpose: The purpose of this case study series was to introduce successful implant cases that used the palatal bone in patients with severe maxillary alveolar bone atrophy or defects. Case Presentation: In this case series study, a total of four patients underwent implant placement in the palatal bone of the maxilla. A total of 6 implants were installed using the palatine bone. The patients' ages ranged from 40 to 73 years with an average age of 63.5 years. The patients had maxillary sinus-related diseases, such as maxillary sinusitis, oroantral fistula, and dentigerous cysts, prior to implantation. To achieve initial stability, the implants were placed on the palatal side, and buccally tilted. The average postoperative recovery period was 8 months. No postoperative complications occurred in any of the cases, and the approach was used without reported issues. Conclusion: Implant treatment by securing the initial fixation in the palatal bone is a good alternative when an implant must be installed in a patient who requires extensive and invasive bone graft.

The feasibility of immediately loading dental implants in edentulous jaws

  • Henningsen, Anders;Smeets, Ralf;Wahidi, Aria;Kluwe, Lan;Kornmann, Frank;Heiland, Max;Gerlach, Till
    • Journal of Periodontal and Implant Science
    • /
    • 제46권4호
    • /
    • pp.234-243
    • /
    • 2016
  • Purpose: Immediate loading of dental implants has been proved to be feasible in partially edentulous jaws. The purpose of this retrospective investigation was to assess the feasibility of immediately loading dental implants in fully edentulous jaws. Methods: A total of 24 patients aged between 53 and 89 years received a total of 154 implants in their edentulous maxillae or mandibles. Among the implants, 45 were set in fresh extracted sockets and 109 in consolidated alveolar bones. The implants were provisionally managed with chair-side made provisional resin bridges and exposed to immediate loading. Implants were followed up for 1-8 years, including radiographic imaging. Marginal bone levels were evaluated based on radiographic imaging. Results: A total of 148 out of the 154 implants survived over the follow-up period of 1 to 8 years, giving a survival rate of 96%. The time or region of the implantation, the pre-implant augmentation, and the length and diameter of the implants had no statistically significant influence on the survival or the success rate. The marginal bone level remained stable with only minimal loss of 0.3 mm after 60 months of loading. Conclusions: Within the limitations of this study, immediate loading is feasible for dental implants in edentulous jaws.

Effects of fresh mineralized dentin and cementum on socket healing: a preliminary study in dogs

  • Kadkhodazadeh, Mahdi;Ghasemianpour, Majid;Soltanian, Negar;Sultanian, Gholam Reza;Ahmadpour, Shahriar;Amid, Reza
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권3호
    • /
    • pp.119-123
    • /
    • 2015
  • Objectives: Dentin is composed of many minerals and growth factors. Based on this composition, we studied its effect as a possible regenerative material for alveolar healing. Materials and Methods: This study was conducted using four 2.5-year-old mongrel dogs (male; weight, 25 to 30 kg). The third mandibular premolars were carefully mobilized with a dental elevator and then removed using forceps. The crown portions of the extracted teeth were removed with cutters, and the root portions of the remaining teeth were collectively trimmed as closely as possible to 350 to $500{\mu}m$. Dentin and cementum (DC) chips harvested from the extracted teeth were soaked in blood and packed into the fresh sockets (autograft). Biopsies were performed at the ends of day 14 and day 56 following implantation. Data were expressed as $mean{\pm}standard$ deviation and compared with t-test results. Results: The ratio of $S_A$(bone) to total area of each probe was determined and was $170{\pm}16{\mu}m^2$ for the control group and $71{\pm}14{\mu}m^2$ for the DC group, a significant difference (P <0.05). Conclusion: DC particulate grafts offered no improvement in bone regeneration in alveolar extraction sockets.

Volumetric stability of autogenous bone graft with mandibular body bone: cone-beam computed tomography and three-dimensional reconstruction analysis

  • Lee, Hyeong-Geun;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권5호
    • /
    • pp.232-239
    • /
    • 2015
  • Objectives: The purpose of this study was to estimate the volumetric change of augmented autobone harvested from mandibular body cortical bone, using cone-beam computed tomography (CBCT) and three-dimensional reconstruction. In addition, the clinical success of dental implants placed 4 to 6 months after bone grafting was also evaluated. Materials and Methods: Ninety-five patients (48 men and 47 women) aged 19 to 72 years were included in this study. A total of 128 graft sites were evaluated. The graft sites were divided into three parts: anterior and both posterior regions of one jaw. All patients included in the study were scheduled for an onlay graft and implantation using a two-stage procedure. The dental implants were inserted 4 to 6 months after the bone graft. Volumetric stability was evaluated by serial CBCT images. Results: No major complications were observed for the donor sites. A total of 128 block bones were used to augment severely resorbed alveolar bone. Only 1 of the 128 bone grafts was resorbed by more than half, and that was due to infection. In total, the average amount of residual grafted bone after resorption at the recipient sites was $74.6%{\pm}8.4%$. Conclusion: Volumetric stability of mandibular body autogenous block grafts is predictable. The procedure is satisfactory for patients who want dental implants regardless of atrophic alveolar bone.

The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey

  • Safi, Yaser;Amid, Reza;Zadbin, Fariba;Ahsaie, Mitra Ghazizadeh;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.251-260
    • /
    • 2021
  • Purpose: Dental implants are widely used for the rehabilitation of edentulous sites. This study investigated the occurrence of dental implant malpositioning as shown on post-implantation cone-beam computed tomography (CBCT) and to identify related factors. Materials and Methods: Samples with at least 1 malpositioned dental implant were collected from a central radiology clinic in Tehran, Iran from January 2017 to January 2019. Variables such as demographic characteristics, length and diameter of implants, type of implant, sites of implant insertion, different types of implant malpositioning problems (cortical plate perforation, interference with anatomical structures), angulation of the implant, and the severity of malpositioning were assessed. In addition, the incidence of implant fracture and over-drilling was evaluated. Data were statistically analyzed using the chi-square test, 1-sample t-test, and Spearman correlation coefficients. Results: In total, 252 patients referred for implant postoperative CBCT evaluations were assessed. The cases of implant malpositioning included perforation of the buccal cortical plate (19.4%), perforation of the lingual cortical plate (14.3%), implant proximity to an adjacent implant (19.0%), implant proximity to an adjacent tooth (3.2%), interference with anatomical structures(maxillary sinus: 18.3%, mandibular canal: 11.1%, nasal cavity: 6.3%, mental foramen: 5.6%, and incisive canal: 0.4%). Implant fracture and over-drilling were found in 1.6% and 0.8% of cases, respectively. Severity was categorized as mild (9.5%), moderate (35.7%), severe (37.7%), and extreme (17.1%), and 52.4% of implants had inappropriate angulation. Conclusion: CBCT imaging is recommended for detecting dental implant malpositioning. The most common and severe type of malpositioning was buccal cortex perforation.

약물함유 생체분해성 차폐막의 생채활성도 및 골조직 유도재생 효과 (Cellular activity and guided bone regenerative effect of drug-loaded biodegradable membranes)

  • 김원경;최상묵;한수부;권영혁;정종평;이승진
    • Journal of Periodontal and Implant Science
    • /
    • 제27권1호
    • /
    • pp.129-150
    • /
    • 1997
  • The purpose of this study was to evaluate the effects of tetracycline(TC}, flurbiprofen, and PDGF-BB loaded biodegradable membranes on the cell-attachment, the activity of loaded PDGF-BB, in vivo release kinetics, and guided bone regenerative potentials. To evaluate the cell attachment to membranes, the number of gingival fibroblasts attached to each membrane(10% TC, 10% flurbiprofen, $200ng/cm^2$ PDGF-BB loaded membranes, drug-unloaded membrane) was counted by coulter counter and the morphologic pattern of attached cells was examined under SEM. To determine whether the activity of loaded PDGF-BB is sustained, the cellular growth and survival rate of gingival fibroblasts was used for both standard PDGF-BB and loaded PDGF-BB. For evaluation of in vivo release kinetics, drug-loaded membranes were implanted on the dorsal skin of the rats. On 1, 3, 7, 10, 14, 21, and 28 days after implantation, the amount of remaining drugs were measured by HPLC assay for TC and flurbiprofen, and by ${\gamma}-scintillation$ counter for $PDGF-BB^{1125}$. For evaluation of guided regenerative potential, the amount of new bone in the calvarial defect(5mm in diameter) of the rat was measured by histomorphometry 1 and 2 weeks after implantation of membranes. The number of cells attached to the PDGF-BB loaded membrane was largest as compared with the other mernbranes.(p< 0.05) The activity of loaded PDGF-BB was not significantly different from the activity of standard PDGF-BB.(p<0.05) After initial burst release of drug during the first 24 hours, drugs were gradually released for 4 weeks. Especially the release rate of PDGF-BB was nearly constant during 4 weeks. PDGF-BB loaded membranes(200, $400ng/cm^2$) were effective in guided bone regeneration as compared with drug-unloaded membrane. These results implicate that drug-loaded biodegradable membranes might be a useful for guided bone regeneration.

  • PDF

치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례 (Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report)

  • 송지은;박송이;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.267-275
    • /
    • 2023
  • 디지털 자료를 이용한 진단 및 즉시 임플란트 식립, 그리고 보철 수복 방법은 전통적인 방법에 비하여 비교적 간단한 자료 채득을 통해 치료 과정을 간소화하고 정확도를 개선하며 데이터의 다양한 활용이 가능하다는 장점이 있다. 임플란트 즉시 식립 시 더 나은 심미적 결과를 얻기 위해서는 발치와의 치유 중에 임플란트 주변 연조직을 개선해야 한다. 이를 위하여 임시 보철물의 즉시 수복을 통해 출현윤곽의 형태를 적절하게 유도할 수 있으며, 향후 최종 수복시에 좋은 임상결과를 얻을 수 있어 환자 만족도가 높다. 본 증례는 상악 좌우 중절치에 외상 후 수평 치근파절이 발생함에 따라 심미성과 치조골 상태를 고려한 발치 후 임플란트 즉시 식립 및 부하를 계획하였다. 디지털 구강 스캐너를 이용한 인상 채득을 통해 외상 치아에 외력을 가하지 않으면서 보다 심미적인 보철물의 제작을 위한 디지털 진단 왁스업을 시행하였으며, 이를 토대로 이상적인 식립 위치를 결정하고 3D 프린팅 수술용 가이드를 이용한 임플란트 즉시 식립을 시행하였다. 식립 5일 후 임시 보철물을 수복하였으며, 3개월 동안 임시 보철물의 형태를 이용한 연조직 개선 및 형태 유도 과정을 거쳐 최종 지르코니아 보철물 수복하였다.