• Title/Summary/Keyword: Dental Implant Material

Search Result 367, Processing Time 0.031 seconds

A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS (표면처리가 다른 5종 임플랜트의 안정성에 관한 연구)

  • Kim Sun-Jong;Shin Sang-Wan;Jung Sung-Min;Ryu Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

THE EFFECT OF SCREW TIGHTENING SEQUENCE AND TIGHTENING METHOD ON THE DETORQUE VALUE IN IMPLANT-SUPPORTED SUPERSTRUCTURE (임플랜트 지지 상부구조물에서 나사조임순서와 조임방법이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo;Lee, Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.653-664
    • /
    • 2007
  • Statement of problem: The screw detorque value is a measure of the preload remaining in the screw just before detorquing. Purpose: This study evaluated the effect of different screw tightening sequences and tightening methods on detorque values for a well-fitting implant superstructure. Material and method: An implant superstructure that connected directly to four implants (Astra Tech) was fabricated on a fully edentulous mandibular acrylic resin model. Six well-fitting dental stone casts were made with a pickup impression of the superstructure from the acrylic resin model. To evaluate the effect of three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and two tightening methods (2-step and 1-step) on the stability of screw joint, the detorque values for a well-fitting implant superstructure were measured twice after screw tightening using 20 Ncm. Detorque values were analyzed using multi-way analysis of variance and two-way analysis of variance at a .05 level of significance. Results: 1. The mean detorque values for three screw tightening sequences were 12.3 Ncm, 12.6 Ncm, and 12.0 Ncm, respectively. 2. The mean detorque values for two screw tightening methods were 12.0 Ncm, and 12.2 Ncm, respectively. 3. The mean of mimimum detorque values for three screw tightening sequences and for two tightening methods were 10.6 Ncm, 11.1 Ncm, 10.5 Ncm, and 9.8 Ncm, respectively. 4. No statistically significant differences among the variables of screw tightening sequence and tightening method were found (p>.05) for detorque values and for mimimum detorque values. Conclusion: Within the limitations of this study, the screw tightening sequence and tightening method did not have a significant effect on the detorque values for a well-fitting implant superstructure.

Effect of embossed new dental pick on periodontitis (Embossed new dental pick이 치주염에 미치는 영향)

  • Suk, Hun-Joo;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.563-572
    • /
    • 2004
  • Since bacterial plaque is known as the major cause of every oral disease, it is necessary to control plaque to maintain periodontal health. Although tooth brushing has been the typical method of plaque control, additional use of plaque control devices are necessary for cleansing interdental areas. Dental floss has been used for a long time as the additional plaque control device and proved to be effective. The newly developed embossed new dental pick is composed of elastic plastic material in form with its tip longer than other toothpick. In addition, as thickness of the tip gradually increases, it can be adapted easily with minimal trauma to interdental gingiva. The embossed tip can remove dental plaque easily, and the opposite end can approach lingual and palatal areas through triple angulation. Therefore, the authors studied the effect of embossed new dental pick and dental floss on periodontally involved 15 patient. The following results were obtained. 1. For embossed new dental pick, probing depth at baseline, 1 week, 4 weeks were $3.6{\pm}0.6mm$, $3.4{\pm}0.5mm$, $3.2{\pm}0.5mm$, respectively, and $4.2{\pm}0.9mm$, $4.1{\pm}0.9mm$, $4.0{\pm}0.9mm$, respectivly for clinical attachment level. 2. In case of embossed new dental pick, bleeding on probing at baseline, 1 week, 4 weeks were $43.0{\pm}4.4%$, $28.5{\pm}5.1%$, $22.2{\pm}5.6%$, respectively, and, at 1 week and 4 weeks, they were significantly different from that of dental floss. 3. Gingival index of toαhpick at baseline, 1 week, 4 weeks were $1.7{\pm}0.5$, $1.0{\pm}0.3$, $0.9{\pm}0.2$, respectively, and, $1.7{\pm}0.5$, $1.1{\pm}0.4$, $1.0{\pm}0.4$, respectively for plaque index, and $3.0{\pm}0.5$, $1.7{\pm}0.5$, $1.4{\pm}0.4$, respectively for proximal plaque index. proximal plaque index at 4 weeks was significantly different from that of dental floss. 4. The result of questionnaire showed that the two types of device were both satisfactory, however, embossed new dental pick had higher preference as well as satisfaction. As a result, embossed new dental pick is thought to be clinically effective for its simplicity and good accessibility.

Retrospective study of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads (SLA 표면 처리와 미세나사선을 가진 내측 연결형의 국산 임플란트에 대한 후향적 연구)

  • Doh, Re-Mee;Moon, Hong-Suk;Shim, Jun-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.136-147
    • /
    • 2009
  • Statement of problem: Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Implantium^{(R)}$ implant, which features a sandblasted and acid-etched surface and internal connection with microthreads. Material and methods: 106 $Implantium^{(R)}$ implants placed in 38 patients at Yonsei University Hospital were examined to determine the effect of various factors on implant success and marginal bone loss, through clinical and radiographic results during a 6 to 30 month period. Results: 1. Out of a total of 106 implants placed in 38 patients, one fixture was lost, resulting in a 99.1% cumulative survival rate. 2. Among the 96 implants which were observed throughout the study period, the survival rates were 97.0% in the maxilla and 100% in the mandible. The survival rate in the posterior regions was 98.9% and 100% in the anterior regions. 3. The mean bone loss during the first year after prosthesis placement was 0.17 mm, while the mean annual bone loss after the first year was 0.04 mm, which was statistically less than during the first year(P<.05). 4. There was no significant difference in marginal bone loss according to age during the first year(P>.05), but after the first year, the mean annual bone loss in patients above 50 years was significantly greater(P<.05) compared with patients under 50 years. 5. No significant difference in marginal bone loss was found according to the following factors: gender, jaw, location in the arch, type of implant(submerged or non-submerged), presence of bone grafts, type of prostheses, and type of opposing dentition(P<.05). Conclusion: Based on these results, the sole factor influencing marginal bone loss was age, while factors such as gender, jaw, location in the arch, type of implant, presence of bone grafts, type of prostheses and type of opposing dentition had no significant effect on bone loss. In the present study, the success rate of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads was satisfactory up to a maximum 30 month period, and the marginal bone loss was in accord with the success criteria of dental implants.

Bioactivity of Calcium Phosphate Ceramic Coatings on Metallic Implants

  • Kim, Cheol-Sang;Ducheyne, P.
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.5-12
    • /
    • 1990
  • Calcium phosphate ceramics have been applied intensively to orthopaedic and dental implants by virtue of their osteoconductive nature. In an attempt to enhance the bone implant intergrity and Eta utility, these ceramics are deposited onto the porous surface of metallic implants. The coating procedure and the ensuing phase transformations of the ceramic alter the mechanical properties and surface chemistry of the ceramic layers as well as those of the substrate. These structural and compositional differences are directly related to the interaction mechanisms at the surface-active ceramicbone interface. Material and processing induced influences on dissolution, electrokinetic behavior, ceramic-metallic substrate interface and boRe growth enhancement are presented.

  • PDF

A literature review on implant abutment and soft tissue response (임플란트 지대주와 임플란트 주위 연조직의 반응에 관한 고찰)

  • Lee, Young-Hoon;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • In the implant prosthetic procedure, the soft tissue reaction was varied with the material and surface treatment of the abutment. It may be the cause of the peri-implantitis, and hence it can affect the long-term prognosis of the implant prosthesis. Titania and zirconia abutment presented superior biocompatibility and stable soft tissue reaction, while gold alloy abutment showed unfavorable reaction sometimes. A soft tissue reaction can be differed by the surface characteristics even in the same material type. Because rougher surface induces a bacterial attachment, the part contacting a soft tissue should have smooth surface. Additional surface treatment can enhance the cellular response without increasing bacterial attachment. Repeated removal and insertion of the abutment and the shape of the abutment may affect the soft tissue reaction, also. Ultrasonic cleaning and argon plasma cleaning are effective way to clean the retained micro-dust on the customized abutment.

Prevention and management of foreign body ingestion and aspiration during the dental treatment (치과 치료에서 발생하는 이물질의 삼킴과 흡인의 예방과 대처)

  • Jeon, Han-Sol;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.63-71
    • /
    • 2018
  • Prosthetic restorations through implants were popularized, and they became routine treatments. Small accessories used in the implant prosthodontic procedure are more likely to slip or fall off the dentist's hands. If the dental appliance or material passes into the upper gastrointestinal tract, there is a high possibility of excretion to the outside of the body without complications, but serious complications may occur depending on the type of foreign body. If the foreign body is passed to the airway, it is an emergency situation, and if it is not done properly, it can be fatal. The purpose of this review report is to investigate the process of foreign body ingestion or aspiration during dental treatment, and the method of prevention and treatment.

Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

Histological healing after grafting of bilayer artificial dermis in the oral environment (치은부에 이식한 이중인공진피의 조직학적 치유)

  • Kim, Min-Jeong;Chung, Hyun-Ju;Kim, Ok-Su;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.289-299
    • /
    • 2003
  • The autogenous free gingival graft is the most predictable procedure currently used to increase the width of the attached gingiva in periodontics. But the major disadvantage of the procedure is to create the multiple surgical wounds at both a donor site and a recipient site. The other problem is the limited amount of available graft material in oral cavity. Therefore, recent researches have been focused to develop the biomaterial to substitute the autogenous gingival tissue. The purpose of this study was to evaluate the histologic healing after grafting of bilayer artificial dermis, compared to the free gingival graft. Four non-smoking subjects (mean age, 32.5 years) in systemically healthy state and good oral hygiene were selected according to their particular needs for correction of mucogingival problems as suggested by Nabers(1966). The recipient sites were prepared through the procedure for the free gingival graft and were grouped according to the graft materials: Experimental group(n=5) - bilayer artifcia1 dermis ($Terudermis^{(R)}$; Terumo Co. Japan) and Control group(n=6) - free gingival graft with autogenous palatal mucosa. Biopsies were harvested at 1,2,3 and 6 weeks postsurgery to evaluate histologically. At the third week in the experimental group and at the second week of in the control group, the grafts has been clinically stabilized on the recipient bed and the graft border has been blended into the surrounding tissue. In the experimental group after 1 week of grafting, the epithelial migration from the adjacent tissue to graft material was seen and after 3 weeks of grafting, the : nflmmation decreased, collagen layer of the artificial dermis was lost and the basement membrane of epithelium was formed. After 6 weeks of grafting, both groups demonstrated orthokeratinized epithelium and increased thickness of epithelial tissue and the rete peg formation, similar to the adjacent tissue, Histologic evaluation revealed a biologic acceptance and incorporation of the collagen layers of the graft tissue to the host tissue, without foreign body reaction. In conclusion, a bilayer artificial dermis is essentially similar to autogeneous free gingival graft in the correction of mucogingival problems, and has the advantages of decreased patient morbidity (no donor site) and availability of abundant amounts of graft material when needed.

Surface Treatments of Titanium Biomaterials by Anodization (양극산화법에 의한 생체적합형 티타늄 표면 개질)

  • Mun, Kyu-Shik;Kim, Jae-Yeon;Kim, Dong-Hyun;Cheon, Se-Jun;Kim, Hyo-Eun;Lee, Myoung-Hoon;Choi, Won-Youl
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.306-306
    • /
    • 2007
  • The surface was transformed to porous titanium oxide by the anodization of pure titanium. Titanium was anodized in non-aqueous and aqueous electrolytes at different potentials between 5 V and 150 V. Various electrolytes were compose of ethylene glycerol, $H_2SO_4,\;NH_4F\;and\;H_2O$. We obtained titania nanotube arrays on the micro pore of titanium. Micro pores and nano tubes were obtained by anodization at high potentials and low potentials, respectively. Morphologies of nanotubes and micro pore were characterized by FE-SEM. The unique surface structure is very attractive to electrical and medical applications such as gas sensor, biosensor, dental implant and stent.

  • PDF