• Title/Summary/Keyword: Dental Image Processing

Search Result 81, Processing Time 0.021 seconds

Measuring abutment convergence angles using stereovision dental image processing system

  • Yang, Hong-Seok;Park, Ji-Man;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.259-265
    • /
    • 2014
  • PURPOSE. The purpose of this study was to develop a dental image processing system using a three-dimensional (3D) camera and stereovision technology. The reliability of the system for measuring axial wall convergence angles was evaluated. MATERIALS AND METHODS. The new system predicted 3D coordinate points from 2D images and calculated distances and angles between points. Two examiners measured axial wall convergence angles for seven artificial abutments using a traditional tracing-based method (TBM) and the stereovision-based method (SVBM). Five wax abutment models of simplified abutment forms were made and axial wall convergence angles of wax models were measured by both methods. The data were statistically analyzed at the level of significance, 0.05. RESULTS. Intraclass correlation coefficients showed excellent intra-examiner and inter-examiner reliabilities for both methods. Bland-Altman plots and paired t-tests showed significant differences between measurements and true values using TBM; differences were not significant with SVBM. CONCLUSION. This study found that the SVBM reflected true angle values more accurately than a TMB and illustrated an example of 3D computer science applied to clinical dentistry.

THE CHANGE OF FILM CHARACTERISTICS ACCORDING TO THE PROCESS OF USING TIME OF PROCESSING SOLUTION (현상액의 사용 시일 경과에 따른 필름 특성의 변화)

  • Chung Moon Sung;Chung Hyun Dae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.128-136
    • /
    • 1992
  • This study was undertakened to investigate the change of image characteristics on dental films according to the process of using time of processing solution in automatic processor. Base + fog density, film density and subject contrast were measured with the digital densitometer, the pH of developing and fixing solution were measured with Digital pH / ION Meter. The following results were obtained: 1. Base + fog density was increased with the process of using time of the processing solution and was over the maximum permissible base + fog density 0.25 from the 3rd day. 2. Film density was increased with the process of using time of the processing solution. 3. Subject contrast was decreased with the process of using time of the processing solution. 4. The pH of the developing solution was decreased with the process of using time, the pH of the fixing solution was increased.

  • PDF

A Study on the Image Enhancement of OCT Image using Wavelet coefficients (웨이블릿 계수를 적용한 OCT영상의 이미지향상에 관한 연구)

  • 이승용;황대석;류재훈;이영우;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.140-143
    • /
    • 2004
  • The mage enhancement of dental On image using wavelet coefficients is presented. The processing is that make gray image from On image by preprocessing, extract high frequency from detail coefficient after acquisition detail coefficient by wavelet transform and emphasize edge appling input image. Experimental results show that enhanced contrast of dental On image, improved mage quality.

  • PDF

치과용 DICOM encoder와 viewer의 특성과 개발

  • Lee, Seung-Won;Ju, Seong-Dae;Lee, Seok-Yeong;Gang, Seung-Hun
    • The Journal of the Korean dental association
    • /
    • v.43 no.1 s.428
    • /
    • pp.41-52
    • /
    • 2005
  • Information Technology has extended its scope to the medical field as well as dental field. Like medical field, network ststem for dental field requires acquisition, storage, and display of images. However, unlike the medical field, the system to integrate several information including medical images has not been developed according to industrial standard for management of digital image for medical use, so called DICOM conformance. which makes the digital environment in dental field more and more difficult and expensive for this standardization and comfortable communication in LAN and WAN. To solve this problem, the DICOM encoder and server has to be developed because the DICOM file can be easily retrieved with patient's information from the DICOM server in the system as DICOM file has the standard specification to integrate the patient's information. The information including image and other discrete data can be easily integrated in DICOM file and can be used without any difficulty for precise diagnosis and for contribution to the decision making for each treatment protocol. Therefore, the system composed of DICOM encoder and server in dental practive for DICOM file must be developed with prudent consideration of the several strategic factors: I) Enhanced diagnostic capability through the integrated information of image and clinical data. ii) Clinician-friendly interface to simulate the systemic treatment procedure in clinical practice iii) Implementation of multidisciplinary treatment protocol The development of DICOM encoder and server based on these strategic considerations will provide paperless and filmless hospital environments by the seamless integration and management of patient's history, several clinical data and clinical images through image processing for quantitative analysis. The system also allows clinicians to provide more predictable dental care for the patients.

  • PDF

Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

  • Shin Jeong-Won;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.213-219
    • /
    • 2002
  • Purpose : Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques, During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. Materials and Methods : The diagnostic quality of conventional cephalometric radiographs (MO) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Results and Conclusion: In comparison with the conventional cephalometric radiograph (MO), Ml showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p < 0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in Ml, and 1 location in MO. The image modality that observers selected as having the best image quality was M5.

  • PDF

Image Reformation with a Personal Computer for Dental Implant Planning (치과 임플란트 계획시 개인용 컴퓨터를 이용한 영상재형성에 관한 연구)

  • Eun-Kyung Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.255-264
    • /
    • 1996
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 4 mandibles of 4 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. personal computer used for image reformation was PowerWave 604/120 (Power computing Co, U.S.A. ) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and ImportACLESS Vl.1 (Designed Access Co., U.S.A.) for importing CT images and NIH image 1.58 (NIH, U.S.A.) for image processing. Seven image were selected among the serial reconstructed cross-sectional images produced by Dentascan. Seven resliced cross-sectional images at the same position were obtained at the personal computer. Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformer cross-sectional images using Mac-compatible computer was highly correlated with those using workstation with Dentascan software(height : r2= 0.999, p<0.001, width : r2= 0.993, p <0.001). So, it is considered that we can use a personal computer with inexpensive software for the dental implant planning, instead of the expensive software and workstation.

  • PDF

Investigation of the Super-resolution Algorithm for the Prediction of Periodontal Disease in Dental X-ray Radiography (치주질환 예측을 위한 치과 X-선 영상에서의 초해상화 알고리즘 적용 가능성 연구)

  • Kim, Han-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 2021
  • X-ray image analysis is a very important field to improve the early diagnosis rate and prediction accuracy of periodontal disease. Research on the development and application of artificial intelligence-based algorithms to improve the quality of such dental X-ray images is being widely conducted worldwide. Thus, the aim of this study was to design a super-resolution algorithm for predicting periodontal disease and to evaluate its applicability in dental X-ray images. The super-resolution algorithm was constructed based on the convolution layer and ReLU, and an image obtained by up-sampling a low-resolution image by 2 times was used as an input data. Also, 1,500 dental X-ray data used for deep learning training were used. Quantitative evaluation of images used root mean square error and structural similarity, which are factors that can measure similarity through comparison of two images. In addition, the recently developed no-reference based natural image quality evaluator and blind/referenceless image spatial quality evaluator were additionally analyzed. According to the results, we confirmed that the average similarity and no-reference-based evaluation values were improved by 1.86 and 2.14 times, respectively, compared to the existing bicubic-based upsampling method when the proposed method was used. In conclusion, the super-resolution algorithm for predicting periodontal disease proved useful in dental X-ray images, and it is expected to be highly applicable in various fields in the future.

Image quality assessment of pre-processed and post-processed digital panoramic radiographs in paediatric patients with mixed dentition

  • Suryani, Isti Rahayu;Villegas, Natalia Salvo;Shujaat, Sohaib;De Grauwe, Annelore;Azhari, Azhari;Sitam, Suhardjo;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.261-268
    • /
    • 2018
  • Purpose: To determine the impact of an image processing technique on diagnostic accuracy of digital panoramic radiographs for the assessment of anatomical structures in paediatric patients with mixed dentition. Materials and Methods: The study consisted of 50 digital panoramic radiographs of children aged from 6 to 12 years, which were later on processed using a dedicated image processing method. A modified clinical image quality evaluation chart was used to evaluate the diagnostic accuracy of anatomical structures in maxillary and mandibular anterior and maxillary premolar region of processed images. Results: A statistically significant difference was observed between pre and post-processed evaluation of anatomical structures(P<0.05) in the maxillary and mandibular anterior region. The anterior region was found to be more accurate in post-processed images. No significant difference was observed in the maxillary premolar region (P>0.05). The Inter-observer and intra-observer reliability of both pre and post processed images were excellent (>0.82) for anterior region and good (>0.63) for premolar region. Conclusion: The application of image processing technique in digital panoramic radiography can be considered a reliable method for improving the quality of anatomical structures in paediatric patients with mixed dentition.

Bone loss Detection in Dental Digital X-ray Image by Structure Analysis (구조적 분석을 이용한 치과용 디지털 X-ray 영상에서의 골조직 변화 검출에 관한 연구)

  • Ahn, Yong-Hak;Chae, Ok-Sam
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.275-280
    • /
    • 2004
  • In this paper, we propose automatic subtraction radiography algorithms to overcome conventional subtraction radiography's defects by applying image processing technique. In order to reach these goals, this paper suggests the image alignment method that is necessary for getting subtraction image and ROI(Region Of Interest) focused on a selection method using the structure characteristics in target images. Therefore, we use these methods because they give accurary, consistency and objective information or data to results. According to the results, easily and visually we can identify fine difference int the affected parts wether they have problems or not.

The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT (임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구)

  • Lee Sul-Mi;An Chang-Hyeon;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF