• Title/Summary/Keyword: Dental Enamel

Search Result 508, Processing Time 0.029 seconds

THE EFFECTS OF NANO-SIZED HYDROXYAPATITE ON DEMINERALIZATION RESISTANCE AND BONDING STRENGTH IN LIGHT-CURED GLASS IONOMER DENTAL CEMENT (광중합형 글라스아이오노머 시멘트의 탈회 저항성과 결합 강도에 대한 나노미터 입자의 하이드록시아파타이트의 효과)

  • Kim, Ji-Hee;Lee, Yong-Keun;Kim, Seong-Oh;Song, Je-Seon;Choi, Byung-Jai;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.24-34
    • /
    • 2010
  • The aim of this study was to evaluate the effect of incorporated nano HA on the demineralization resistance and bonding strength of LC GIC in comparison with micro HA. Fuji II LC GIC was used as the control group and a base material for experimental groups. Two experimental groups were prepared. One was prepared by adding 15% micro HA to LC GIC by weight ratio (Exp. 1), and the other was prepared by adding 15% nano HA instead (Exp. 2). According to the results, the following conclusions could be obtained. 1. Observing under the CLSM, the control group showed thicker enamel demineralization layer than in the experimental groups, and the Exp. 2 group showed the thinnest demineralization layer. 2. In SEM analysis, there was greater enamel demineralization in the control group. The Exp. 2 group was more resistant to demineralization compared to the Exp. 1 group. 3. The bonding strength was found to be in the increasing order of control, Exp. 1, and Exp. 2 group (p < 0.05). 4. Observing the fractured surfaces under SEM after the bonding strength test was performed, there were bone-like apatite particles formed in HA-added experimental groups, and a greater number of bone-like apatite particles were formed in the Exp. 2 group compared to the Exp. 1 group.

Evaluation of Caries Status among Adolescents in Jeonju City with WHO Basic Methods, International Caries Detection and Assessment System II (ICDAS-II) (WHO basic methods와 International Caries Detection and Assessment System II (ICDAS-II)를 사용한 전주시 청소년의 우식상태 조사)

  • Park, Kibong;Kim, Doyoung;Lee, Daewoo;Kim, Jaehwan;Yang, Yoenmi;Kim, Jaegon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.382-390
    • /
    • 2016
  • Since it is favorable to include the incipient caries lesion in the diagnostic criteria in adolescence, this study had surveyed dental caries status of adolescents at ages of 13 and 16 by using WHO basic methods and ICDAS-II codes. In this study, mean DMFT index was 3.71, and mean DT index was 1.94. For both indices, the age 16 group showed higher values than the age 13 group. By groups of teeth, DMFT index and DT index exhibited highest to the lowest values in molar, premolar, and anterior teeth, respectively. 77.46% of total numbers of teeth were classified as code 0 in ICDAS-II. Compared to anterior teeth, numbers of decayed teeth were increased in posterior teeth. All caries lesions in anterior teeth and premolars were limited to enamel. ICDAS-II code is an useful method to detect the incipient caries lesion, allowing preventive control on caries management.

Application of the QLF technology to monitor recovery rates of enamel caries lesions with human saliva (법랑질 병소 회복율 평가를 위한 QLF 기술의 적용)

  • Kim, Gyung-Min;Ku, Hye-Min;Lee, Eun-Song;Kang, Si-Mook;Jong, Elbert de Josselin de;Kwon, Ho-Keun;Kim, Baek-Il
    • The Journal of the Korean dental association
    • /
    • v.55 no.2
    • /
    • pp.156-164
    • /
    • 2017
  • Purpose: The aim of this in vitro study was to assess changes in remineralization by stimulated human saliva over a short period of 48 hours with quantitative light-induced fluorescence (QLF) technology. Materials and Methods: Bovine incisor surfaces were demineralized for 10 days. Two types of stimulated saliva were collected from 7 healthy persons. 24 hours after tooth brushing (Stimulated saliva group) and immediately after tooth brushing with 1,000 ppm NaF dentifrice (Dentifrice saliva group). The specimens were immersed in saliva and fluorescence images were obtained by QLF-digital (QLF-D $biluminator^{TM}$,) at 2, 4, 6, 12, 24, and 48 hours fluorescence loss (${\Delta}F%$) of the lesions. A paired t-test was performed to assess fluorescence differences between before (${\Delta}F_{baseline}$) and after (${\Delta}F_{treatment\;time}$) the remineralization process. Results: Before the remineralization, the mean ${\Delta}F_{baseline}$ of the initial demineralized specimens was $-18.42{\pm}0.15$ (%). In both groups, the ${\Delta}F$ values obtained at baseline and after 2 hours were statistically significant (P < 0.001), indicating recovery of the lesions by approximately 40% after 2 hours. After 48 hours, remineralization rates were slightly higher (49%) for the stimulated saliva group than for the dentifrice saliva group (41%), but the difference was not statistically significant. Conclusions: With QLF minute degrees of remineralization by saliva can be measured in periods as short as 2 hours. Additionally no significantly higher effects of remineralization were observed in the dentifrice saliva group when compared to the stimulated saliva group.

  • PDF

pH and buffering capacity in some commercial fermented milks (일부 시판 유산균 발효유의 pH와 적정산도)

  • Ko, Seok-Ju;Jeong, Seong-Soog;Choi, Choong-Ho;Kim, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.4
    • /
    • pp.701-711
    • /
    • 2013
  • Objectives : The aim of this study was to evaluate the pH and buffering capacity in some commercial fermented milks in Korea. Methods : The study was carried ouf from June to August, 2012. In 35 liquid type, 79 condense-stirred type and 71 condense-drink type fermented milks, available on the market, pH and buffering capacity were measured. Titration(with NaOH) was used to determine the buffering effect of each fermented milk. They were titrated with 1 M sodium hydroxide, added in 0.1 milliliters increments, until the pH reached about 5.5 and 7.0. Results : The average pH of tested fermented milks was $4.08{\pm}0.27$. The average pH values of fermented milks were $3.64{\pm}0.22$ in liquid type, $4.14{\pm}0.12$ in condense-stirred type, and $4.22{\pm}0.17$ condense-drink type. The average buffering capacity (pH 5.5) of tested fermented milk was $2.40{\pm}0.54$. The average buffering capacity (pH 5.5) of liquid type fermented milk was $2.37{\pm}0.33$, condense-stirred type fermented milk was $2.77{\pm}0.46$ and condense-drink type fermented milk was $2.01{\pm}0.42$. The average buffering capacity (pH 7.0) of tested fermented milks was $4.00{\pm}0.87$. The average buffering capacity (pH 7.0) of liquid type fermented milk was $3.11{\pm}0.36$, condense-stirred type fermented milk was $4.78{\pm}0.55$ and condense-drink type fermented milk was $3.58{\pm}0.59$. Conclusions : The average pH of tested fermented milks in this study was lower than pH 4.5. The type of fermented milks was an important factor for selection of fermented milk which is related with enamel erosion.

Effect of coloring agent dryness on zirconia color (치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Hae-Jung;Moon, Yun Hee;Kim, Woong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.176-182
    • /
    • 2018
  • One of the most important factor of esthetic prosthesis is the color of the teeth. Zirconia is produced in the process of design, milling, coloring, drying, and sintering. The effect of the drying degree of zirconia colorant on the color tone is examined. For the experiment, a total of 45 zirconia specimens(15 for each) were fabricated by using cad/cam system. The zirconia specimens(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ)) were then subjected to zirconia sintering in accordance with the manufacturer's instructions, using a chemical coloring agent to Non-drying(0sec), intermediate (10sec), and completely dried (10min) temperature holding times. The color tone was measured using a spectrophotometer. The results were analyzed with a One-way analysis of variance and the Tukey post-hoc test (${\alpha}=.05$) The $L^*$ values of L, A specimens, $a^*$ values of A specimens, and $b^*$ values of Z specimens were not statistically different according to the degree of drying (p>0.05), While the $L^*$ value of Z specimen, $a^*$ value of L, Z specimen, $b^*$ values of L, A specimens were statistically different according to the degree of drying(p <0.05). In conclusion, the drying of zirconia colourants improves zirconia brightness and increases the optical properties of the enamel.

AUGMENTED BONY CHANGE FOLLOWING PLATELET RICH PLASMA(PRP) APPLICATION ON MAXILLARY DEFECT (악골결손부에 PRP적용후 획득된 골의 변화량)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.219-225
    • /
    • 2003
  • Purpose: Platelet Rich Plasma(PRP) application is increasing with sinus inlay bone graft, but there is few research with radiographic ananlysis on effect of PRP in maxillary sinus. The author investigated the amount of bony changes of maxillary sinus for dental implantation among the patients with maxillary inlay graft. Materials and Methods: With 10 patients who were treated with sinus inlay autologous bone grafting combined with PRP technique, and with 5 patients who were treated with sinus inlay grafting only without PRP, the panoramic radiographys which were taken at preoperation, immediate postoperation, 3months postoperation, and 4 months postoperation(a month after dental implantation)periods were analysed. The films had been scanned, and then proceeded throughout image analysis system. The bone density of maxillary grafted sites was compared with adjacent tooth enamel density and remeasured according to density luminosity of each film. The density changes on PRP group and bone graft only group were analysed with non-parameteric statistics method. Results: In PRP combined patients group, bone density on postoperation periods was increased totally. The remarkable enhanced change of bone density was observed on 3 months postoperation period, thereafter the increasing rate was slightly reduced. In only bone graft patients group, bone density on postoperation periods was also increased compared with preoperation period, but the bone density of 4 months postoperation period was decreased compared with 3 months postoperation period. The amount of bone density on PRP group was significantly changed according to periods in contrast to bone graft only group. Conclusion: The bone density on PRP group was remarkably increased at 3 months postoperation compared to bone graft only group and it was seemed to be associated with more new bone formation, less grafted bone resorption at bone grafted sites with PRP.

Effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion (상아세관 폐쇄에 대한 2종의 상아질 지각 과민 체치제와 Er,Cr:YSGG 레이저의 효과)

  • Kim, Na-Song;Kang, Jeong-Kyung;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.48 no.6
    • /
    • pp.469-477
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion. Twenty recently extracted single-rooted human teeth were used to obtain root dentinal fragments. The crowns were cut approximately 1mm below the cementum enamel junction(CEJ). A second cut was used to remove the apex of the root. Subsequently, a longitudinal cut was made in order to obtain 2 fragments from each root sample. The cementum from the cervical portion was removed using a high-speed diamond-coated bur in order to expose the dentin. To open dentinal tubules, forty samples were treated with 50% citric acid for 2 min and then rinsed under distilled water for 1 min. These were divided into four groups of ten samples each. The first group served as a control group. In group 2, the samples were irradiated with the Er,Cr:YSGG laser(Waterlase MD, Biolase, USA). In group 3, the samples were treated with Bisblock and ONE-STEP PLUS(Bisco, USA). In group 4, the samples were treated with Gluma comfort bond & Desensitizer(Heraeus Kulzer, Germany). All the samples were examined using Scanning electron microscopy(Hitachi, S-4700, Japan) with two different magnifications(X2000, X5000). These images were assessed by one examiner who was blind to the experimental procedure, using the index of smear layer removal. The distribution of smear layer removal grades was tested using Fisher's exact test. On the order hand, in order to evaluate the occluding effect of two dentin desensitizers and Er,Cr:YSGG laser, the number of exposed dentinal tubules was counted in each group. These were evaluated using the Kruskal-Wallis test with significance predetermined $\alpha$=0.05. There were statistically significant differences between the three groups(Er,Cr:YSGG laser, Bisblock+ONE-STEP PLUS, Gluma comfort bond & Desensitizer) and control group.

A CLINICAL AND RADIOGRAPHIC STUDY OF DENTIGEROUS CYSTS (함치성 낭의 임상 방사선학적 연구)

  • Lee Kang-Sook;Choi Karp-Shik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.399-408
    • /
    • 1995
  • The purpose of this study was to obtain information on the clinical and radiographic features of the dentigerous cysts in the jaws. For this study, the authors examined and analysed the clinical records and radiographs of 233 patients who had lesions of dentigerous cyst diagnosed by clinical and radiographic or histopathological examinations. And the obtained results were as follows: 1. Dentigerous cysts occurred the most frequently in the 2nd decade(38.2%) and occurred more frequently in males(67.4%) than in females(32.6%). 2. The most common clinical symptom was swelling of the jaw(33.9%), and the lesions were treated by the method of surgical removal. 3. The type of lesions was mainly observed as central type(72.5%), and size of the lesion was most frequently observed 2 - 2.9cm in the widest length. 4. The lesions were most frequently observed well-defined outline with hyperostotic border(49.8%), and smooth margin(73.4%), and homogeneous lesional radiolucency(79.4%). 5. Cortical thinning and expansion of the lesions(82.0%) were observed, and their direction were most frequently observed toward buccal side(64.0%). 6. The effect on the causative tooth were observed as tooth displacement(41.2%) and delayed root development(l9.3%), and the distance between cemento-enamel junction and lesional wall attachment of the causative tooth was mainly observed as below 2mm(79.6%). 7. The effect on the adjacent tooth were observed as loss of lamina dura(66.8%), root resorption(33.9%), and tooth displacement(31.5%). 8. The effects on the adjacent anatomic structures were observed as displacement of the mandibular canal(46.5%) and maxillary sinus or nasal cavity(72.2%).

  • PDF

Radiopacity of contemporary luting cements using conventional and digital radiography

  • An, Seo-Young;An, Chang-Hyeon;Choi, Karp-Sik;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.97-101
    • /
    • 2018
  • Purpose: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. Materials and Methods: Disc specimens (N=24, n=6 per group, ø$7mm{\times}1mm$) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Multilink (3.44-4.33) showed the highest radiopacity, followed by U-cem (1.81-2.88), Panavia F 2.0 (1.51-2.69), and Duolink (1.48-2.59). The $R^2$ values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. Conclusion: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF