• 제목/요약/키워드: Dental Cone-beam CT

검색결과 96건 처리시간 0.026초

Changes of lip morphology following mandibular setback surgery using 3D cone-beam computed tomography images

  • Paek, Seung Jae;Yoo, Ji Yong;Lee, Jang Won;Park, Won-Jong;Chee, Young Deok;Choi, Moon Gi;Choi, Eun Joo;Kwon, Kyung-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.38.1-38.10
    • /
    • 2016
  • Background: The aims of this study are to evaluate the lip morphology and change of lip commissure after mandibular setback surgery (MSS) for class III patients and analyze association between the amount of mandibular setback and change of lip morphology. Methods: The samples consisted of 14 class III patients treated with MSS using bilateral sagittal split ramus osteotomy. Lateral cephalogram and cone-beam CT were taken before and about 6 months after MSS. Changes in landmarks and variables were measured with 3D software program $Ondemand^{TM}$. Paired and independent t tests were performed for statistical analysis. Results: Landmarks in the mouth corner (cheilion, Ch) moved backward and downward (p < .005, p < .01). However, cheilion width was not statistically significantly changed. Landmark in labrale superius (Ls) was not altered significantly. Upper lip prominence angle (ChRt-Ls-$ChLt^{\circ}$) became acute. Landmarks in stomion (Stm), labrale inferius (Li) moved backward (p < .005, p < .001). Lower lip prominence angle (ChRt-Li-$ChLt^{\circ}$) became obtuse (p < .001). Height of the upper and lower lips was not altered significantly. Length of the upper lip vermilion was increased (p =< 0.01), and length of the lower lip vermilion was decreased (p < .05). Lip area on frontal view was not statistically significantly changed, but the upper lip area on lateral view was increased and change of the lower lip area decreased (p > .05, p < .005). On lateral view, upper lip prominent point (UP) moved downward and stomion moved backward and upward and the angle of Ls-UP-Stm ($^{\circ}$) was decreased. Lower lip prominent point (LP) moved backward and downward, and the angle of Stm-LP-Li ($^{\circ}$) was increased. Li moved backward. Finally, landmarks in the lower incisor tip (L1) moved backward and upward, but stomion moved downward. After surgery, lower incisor tip (L1) was positioned more superiorly than stomion (p < .05). There were significant associations between horizontal soft tissue and corresponding hard tissue. The posterior movement of L1 was related to statistically significantly about backward and downward movement of cheilion. Conclusions: The lip morphology of patients with dento-skeletal class III malocclusion shows a significant improvement after orthognathic surgery. Three-dimensional lip morphology changes in class III patients after MSS exhibited that cheilion moved backward and downward, upper lip projection angle became acute, lower lip projection angle became obtuse, change of upper lip area on lateral view was increased, change of lower lip area decreased, and morphology of lower lip was protruding. L1 was concerned with the lip tissue change in statistically significant way.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.

치과용 Cone-beam CT를 이용한 상악 정중과잉치의 3차원적 특성에 관한 후향적 연구 (Retrospective study on three-dimensional characteristics of mesiodens using CBCT in pediatric dentistry)

  • 유지연;송지수;신터전;현홍근;김정욱;장기택;이상훈;김영재
    • 대한소아치과학회지
    • /
    • 제48권1호
    • /
    • pp.77-94
    • /
    • 2021
  • 이 연구의 목적은 Cone-beam형 전산화 단층촬영술 영상을 이용하여 정중과잉치의 3차원적인 특성들에 대해 조사하고 이 특성들과 발거 시 마취 방법 및 합병증에 영향을 미치는 요인들에 대해 분석하는 것이다. 이를 위해 2017년부터 2019년까지 서울대학교 치과병원 소아치과에서 과잉치를 발거한 환자 452명의 총 602개의 정중과잉치를 평가하였다. 지난 20년간 연도별 전체 환자 중 정중과잉치 환자수의 비율이 점차 증가하는 경향을 보였다. 정중과잉치 방향 중 순-구개 방향의 수평위가 근원심 방향의 수평위보다 약 3.2배 많이 관찰되었으며 순-구개 방향의 수평위 중 치근이 순측을 향하는 경우가 전체 수평위 중에서 가장 높게 나타났다. 정중과잉치의 시상면에의 상하 위치는 대부분이 인접 영구치의 치경부 측(37.0%)에서 가장 많이 관찰되었고 순-구개측의 매복 정도를 관찰한 결과 근-구개측이 원-구개측의 약 3.83배 정도 더 높게 관찰되었다. 대부분의 정중과잉치(98.5%)가 CBCT상에서 인접 영구치와 접촉해 있는 것으로 나타났다. 정중과잉치 중 46.2%에서 만곡된 치근이 관찰되었고, 치근이 만곡된 정중과잉치 중 치근의 치근단측 에서의 만곡이 치근의 치경부측에 비해 약 1.83배 높게 나타났다. 소아환자의 정중과잉치 발거 시 사용한 마취 방법 중에서는 전신마취(72.6%)를 시행하여 정중과잉치를 발거한 경우가 가장 많았다. 환아의 연령, 시상면에서의 상하 위치, 부작용 유무가 전신마취 시행 여부에 유의한 영향을 미치는 요인으로 확인되었고 정중과잉치의 방향 및 시상면에서의 상하 위치가 합병증에 영향을 미치는 것으로 나타났다. 이번 연구의 결과는 정중과잉치에 대한 이해를 도와 정확한 진단 및 적절한 치료계획을 수립하는데 유용한 정보를 제공할 수 있을 것으로 사료된다.

국내 치과방사선의 현황 및 이용 실태 (The Actual State and the Utilization for Dental Radiography in Korea)

  • 신귀순;김유현;이보람;김세영;이귀원;박창서;박혁;장계용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.109-120
    • /
    • 2010
  • 치과 X선 검사 시 환자선량의 권고량 가이드라인을 개발하기 위해서 우선 국내 치과방사 선의 현황 및 이용 실태를 설문조사하여 비교분석하였다. 응답을 받은 77곳의 치과병 의원 중에서 치과대학이 있는 치과대학병원을 A그룹(11곳), 치과대학이 없는 대학병원을 포함한 치과병원을 B그룹(30곳), 치과의원을 C그룹(36곳)으로 분류하였다. 그룹별로 분석한 결과는 다음과 같았다. 치과병 의원 한 곳당 평균 unit chairs수는 A그룹 140.2개, B그룹 15.3개, C그룹 5.8개, 평균치과의사수는 A그룹 112.6명, B그룹 7.3명, C그룹 1.7명, 평균방사선사수는 A그룹 3.1명, B그룹 0.5명, C그룹에는 한 명도 없었고, 평균치과위생사수는 A그룹 19.7명, B그룹 12.5명, C그룹 3.3명이었다. 설치된 치과용 X선장치의 평균보유수는 A그룹 14.64대, B그룹 3.21대, C그룹 2.19대로 나타났다. 이 중에서 구내촬영장치가 가장 많았고, 다음은 파노라마 장치, 세팔로 장치, CBCT 장치 순이었으며, 장치시스템의 비율은 세 그룹 모두 DR 시스템이 50% 이상으로 가장 많았다. 필름 시스템인 경우, 사용된 구내필름은 감광도가 높은 Insight 필름(Kodak, USA)이 대부분이었으며, 자동 현상기는 사용하는 곳이 적었으나, 필름유지기구는 사용하는 곳이 약간 많았다. PACS 이용률은 A그룹 90.9%, B그룹 83.3%, C그룹 16.7%이었고, 프로그램은 국내의 Infinitt에서 개발된 PiView STAR가 가장 많이 이용되고 있었다. 치과병 의원 한 곳당 2008년도의 연간 평균촬영건수는 A그룹이 B그룹보다 6.8배, C그룹보다 21.2배 더 많았으며, 구내 치근단 촬영과 파노라마 촬영이 대부분이었다. 구내 치근단 촬영 시 관전압과 관전류는 세 그룹 모두 비슷하였으나, 노출시간은 C그룹이 A그룹의 12배, B 그룹의 3.5배 정도 길었다. 즉, 대부분 치과위생사가 촬영하고 있는 C그룹에서는 방사선 노출량이 다른 그룹에 비해 훨씬 많았다. 그러나 파노라마촬영 시의 조건은 세 그룹에서 큰 차이가 없었다. 결론적으로, 촬영조건은 경험적 지식을 따르기보다는 권장량을 사용해야 하며, 필름시스템에서는 자동현상기와 필름유지기구를 사용하여 방사선의 노출량을 줄여준다. 또한 환자선량의 감소와 X선 영상의 질 향상을위해서 X선발생장치 및 관련기기의 체계적인 정도관리가 반드시 필요하다.

CBCT 및 3D CT를 활용한 상악 유구치 치근과 근관 형태 (Root and Canal Morphology of Maxillary Primary Molar using CBCT and 3D CT)

  • 김준희;김현태;신터전;현홍근;김영재;김정욱;장기택;송지수
    • 대한소아치과학회지
    • /
    • 제48권4호
    • /
    • pp.437-448
    • /
    • 2021
  • 이 연구의 목적은 상악 유구치의 치근 및 근관의 형태학적 특성을 분석하는 것이다. 2006년 1월부터 2020년 4월까지 서울대학교 치과병원에서 CBCT 및 3D CT를 촬영한 3 - 7세 환자 총 268명(남자 175명, 여자 93명)이 연구에 포함되었으며, 치근 흡수와 치수병변이 없는 총 1002개의 상악 유구치의 치근과 근관 수를 분석하였다. 218개의 치아에 대해 치근과 근관의 형태, 이개각도, 치근과 근관의 길이 및 근관의 단면 형태를 분석하였다. 48개의 치아에 대해서는 Mimics 및 3-Matics software를 사용하여 치근 치수의 부피와 표면적, 치근-치수 비를 측정하였다. 절반 이상이 3개의 치근과 3개의 근관을 가지고 있었다. 좌우측 치아의 대칭성(Cohen's kappa coefficient)은 약 0.63이었다. 치근과 근관의 형태는 상악 제1유구치에서는 직선형이, 제2유구치에서는 곡선형이 많이 관찰되었다. 치근의 이개 정도, 치근과 근관의 길이는 상악 제1, 2유구치 모두 구개측 치근에서 가장 크게 나타났다. 근단부에서 근관의 단면 형태는 주로 ovoid 혹은 round형이었다. 치근 치수의 부피와 표면적, 치근-치수 비는 상악 제1,2유구치 모두 구개측 치근 치수에서 가장 크게 나타났다.

제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드 (Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides)

  • 권창렬;최병호;정승미;주상돈
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.271-278
    • /
    • 2012
  • 연구 목적: 최근 정확하면서도 외상이 적은 임플란트 식립을 위해 임플란트 수술용 가이드가 많이 쓰이고 있다. 그 중 대표적인 방식이 stereolithography 방식과 positioning device로 제작한 방식이다. 본 연구는 이 두 가지 방식의 정확성을 비교하기 위하여 4 가지 형태의 치아상실 모델에서 실험 후 정확성에 관하여 분석하였다. 연구 재료 및 방법: 4가지 형태 치아 결손 모델 각각에 대하여 stereolithography 방법과 positioning device를 이용한 방법으로 수술 가이드를 제작하였다. 제작된 수술 가이드를 제작에 사용되었던 치아모델에 장착하여 수술 가이드의 내면과 모델의 치아표면 사이 공간크기를 측정하여 가이드의 적합도를 평가하였다. 또한 이 수술 가이드를 이용하여 총 40개 모델에서 임플란트 시술을 진행하고, 시술 후 모델을 다시 cone-beam computed tomography촬영 하여 수술 전후 영상을 중첩시켜 계획 상의 임플란트와 실제 시술한 임플란트의 위치를 비교하였다. 통계학적인 검증을 위하여 PASW Statistics$^{(R)}$ 18.0을 이용하여서 Mann-Whitney U 검정을 사용하였다. 결과: 수술 가이드 내면과 모델 사이 공간크기가 stereolithography는 $1.4{\pm}0.3mm$이고, positioning device는 $0.4{\pm}0.3mm$로 통계학적으로 유의한 차이를 보였다(P<.05). Stereolithography는 오차가 근원심 측에서 $3.9{\pm}1.6^{\circ}$, 협설 측에서 $2.7{\pm}1.5^{\circ}$, 깊이에서 $1.9{\pm}0.9mm$였다. 반면 positioning device는 오차가 근원심 측에서 $0.7{\pm}0.3^{\circ}$였고, 협설측에서 $0.3{\pm}0.2^{\circ}$, 깊이에서 $0.4{\pm}0.2mm$였다. 두 수술 가이드 제작방법은 모든 방향에서의 오차에서 통계학적으로 유의한 차이를 보였다(P<.05). 결론: 본 연구의 결과는stereolithography방법보다 positioning device를 이용하여 수술 가이드를 제작할 때 C.T.와 임플란트 치료 계획 프로그램을 이용하여 미리 계획한 임플란트 식립 위치와 방향으로 더 정확하게 식립 할 수 있음을 보여 주었다.