• Title/Summary/Keyword: Dental Cement

Search Result 422, Processing Time 0.035 seconds

A STUDY FOR THE CHANGES OF THE MASTICATORY MUSCLES AND THE MANDIBULER MOVEMENT EFFECTED BY INTENTIONAL INCREASE OF ANTERIOR GUIDANCE ANGLE (전치 유도각의 인위적 증가에 의한 저작근과 하악 운동 양상의 변화에 대한 연구)

  • Lee, Yong-Sik;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.245-257
    • /
    • 1998
  • This study was performed to measure the changes of the mandibular movement and the masticatory muscular activities - anterior temporal and masseter muscle of both side - reflected by intentional increase of anterior guidance angie. For this study, 5 volunteers (3 males and 2 females with average age of 24.0) were selected. Each volunteer had Angle's classification I and did not have any missing tooth except third molar and any extensive restorations. Metallic guide plate was made at volunteer's working model fabricated by improved dental stone and cemented to the palatal surface of maxillary central incisor using resin cement(Panavia $21^{(R)}$) and then adjusted not to give any occlusal interferences at intercuspal position. The activity of masticatory muscles and the changes of mandibular movement were recorded by EMG and Sirognathograph in Biopak analysing system(Bioresearch Inc., Milwaukee, Wisconsin, USA). Measurement was done at before experiment, immediatley after placement, 1 week after placement, immediately after removal, and 1 week after removal. The results were as follows: 1. Moderate phonetic disturbance and mild headache were occured to 3 volunteers for 2 days after setting and 1 volunteer had positive reaction to percussion and slight midline diastema. But all of these clinical signs were diappeared 1 week after removal and the other volunteer did not have any special clinical sign. 2. In the EMG of the mandibular rest position, the mean value of anterior tempotal muscle was increased immediately after placement(p<0.01) and then decreased 1 week after placement(p<0.05) and increased 1 week after removal(p<0.05) but not recovered as before experiment. The mean value of masseter muscle was decreased during the experiment period. 3. In the EMG during mandibular protrusive movement, all muscular activity was decreased during the experiment period. Reduced activity was not recovered 1 week after removal(p<0.03). 4. During the habitual opening, anteroposterior movement of mandible was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not statistically significant(p>0.1). Vertical movement was not shown significant difference during the experiment period(p>0.1). Lateral movement was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not recovered as before experiment. The opening and closing velocity of mandible was shown minor changes but not statistically significant. 5. During the habitual opening, anteroposterior movement of mandible was decreased 1 week after placement(p<0.05) and then increased immediately after removal and recovered 1 week after removal as before experiment. Vertical movement was not shown significant changes. Lateral displacement of mandible was increased continuously and recovered 1 week after removal. Opening velocity was temporarily increased immediately after removal but recovered and closing velocity was not shown significant changes. 6. During the right side chewing, anteroposterior movement of mandible was increased immediately after removal but recovered and vertical movement was not shown statistically significant results. Lateral displacement and velocity of mandible were not shown significant results. 7. During the left side chewing, the changes of mandibular movement pattern were not shown statistically significant results.

  • PDF

Effect of mechanical surface treatment on the fracture resistance and interfacial bonding failure of Y-TZP zirconia (Y-TZP zirconia의 기계적 표면처리가 파절저항과 접착계면 실패에 미치는 영향)

  • Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2014
  • Purpose: Surface damage and bonding strength difference after micromechanical treatment of zirconia surface are to be studied yet. The aim of this study was to evaluate the difference of fracture resistance and bonding strength between more surface-damaged group from higher air-blasting particle size and pressure, and less damaged group. Materials and Methods: Disk shape zirconia ($LAVA^{TM}$) was sintered and air-blasted with $30{\mu}m$ particle size (Cojet), under 2.8 bar for 15 seconds, $110{\mu}m$ particle size (Rocatec), under 2.8 bar for 15 seconds, and $110{\mu}m$ particle size (Rocatec), under 3.8 bar for 30 seconds respectively. Biaxial flexure test and bonding failure load test were performed serially (n = 10 per group). For bonding test, specimens were bonded on the base material having similar modulus of elasticity of dentin with $200{\mu}m$-thick resin cement for tension of surface damage. Failure load of bonding was detected with acoustic emission (AE) sensor. Results: There were no significant differences both in the biaxial flexure test and bonding failure load test between groups (P > 0.05). Sub-surface cracks were all radial cracks except for two specimens. Conclusion: Within the limitations of no aging under monotonic load test, surface damage from higher air-blasting particle size and pressure was not significant. Evaluations of failure load with bonded zirconia disks was clinically relevant modality for surface damage and bonding strength, simultaneously.

Photoelastic Stress Analysis of Fixed Partial Dentures (가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Cho, Won-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

Marginal fit of In-Ceram crown according to shoulder width (In-Ceram 전부도재관의 shoulder 폭경에 따른 변연적합도)

  • Chun, Seung-Geun;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.105-112
    • /
    • 2000
  • In-Ceram system is one of contemporary esthetic all ceramic restorations and has relatively high flexural strength. The purpose of this study was to evaluate the marginal fit of In-Ceram crown according to shoulder width and measuring position. In this study, twenty seven In-Ceram crowns devided into three groups, each prepared with shoulder width of 0.6mm, 0.9mm and 1.2mm. All specimens were cemented with glass ionomer cement. After cementation, specimens were measured marginal gap between the margin of the In-Ceram crown and the finishing line of resin master die by using a refrective microscope. Marginal gaps were recorded at the labial, lingual, mesial and distal measuring points on the resin master die. The results of this study were as follows: 1. Mean marginal fits of each group were $81.28{\mu}m$ in 0.6mm shoulder width, $70.78{\mu}m$ in 0.9mm shoulder width and $67.75{\mu}m$ in 1.2mm shoulder width. 2. There was significant difference between group 0.6mm and 0.9mm, 1.2mm.(p<0.05). 3. In comparison of marginal fit according to the measuring points, there was no significant difference.

  • PDF

Histological evaluation of direct pulp capping with DSP-derived synthetic peptide in beagle dog (비글견에서 DSP 유도 합성 펩타이드를 이용한 직접 치수 복조술에 대한 조직학적 연구)

  • Kim, Jae-Hoon;Hong, Jun-Bae;Lim, Bum-Soon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.120-129
    • /
    • 2009
  • The purpose of this study was to investigate the pulpal response to direct pulp capping with dentin sialoprotein (DSP) -derived synthetic peptide in teeth of dogs, and to compare its efficacy to capping substances $Ca(OH)_2$ and white mineral trioxide aggregate (WMTA). A total of 72 teeth of 6 healthy male beagle dogs were used. The mechanically exposed pulps were capped with one of the following: (1) DSP-derived synthetic peptide (PEP group): (2) $Ca(OH)_2$ (CH group): (3) a mixture paste of peptide and $Ca(OH)_2$ (PEP+CH group): or (4) white MTA (WMTA group). The access cavity was restored with a reinforced glass ionomer cement. Two dogs were sacrificed at each pre-determined intervals (2 weeks, 1 month, and 3 months). After the specimens were prepared for standard histological processing, sections were stained with hematoxylin and eosin. Under a light microscope, inflammatory response and hard tissue formation were evaluated in a blind manner by 2 observers. In the PEP group, only 3 of 17 specimens showed hard tissue formation, indication that the DSP-derived synthetic peptide did not induce proper healing of the pulp. Compared with the CH group, the PEP group demonstrated an increased inflammatory response and poor hard tissue formation. The CH and WMTA groups showed similar results for direct pulp capping in mechanically exposed teeth of dogs.

EFFECT OF A DESENSITIZER ON DENTINAL BOND STRENGTH IN CEMENTATION OF COMPOSITE RESIN INLAY (레진 인레이 합착시 지각과민처리제의 사용이 상아질 결합강도에 미치는 영향)

  • Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.223-231
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of a desensitizer on dentinal bond strength in cementation of composite resin inlay. Fifty four molar teeth were exposed the occlusal dentin. Class I inlay cavities were prepared and randomly divided into six groups. Control group: no agent, Group 1 : Isodan, Group 2 : One-step, Group 3 : All-Bond SE, Group 4 : Isodan + One-step, Group 5 : Isodan + All-Bond SE. Desensitizing agent and dentin bonding agents were applied immediately after the completion of the preparations. Impressions were then made. The composite resin inlays (Tescera, Bisco) were fabricated according to the manufacturers' guidelines. Cementation procedures followed a standard protocol by using resin cement (Bis-Cem, Bisco). Specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. All specimens were sectioned to obtained sticks with $1.0{\times}1.0\;mm^2$ cross sectional area. The microtensile bond strength (${\mu}TBS$) was tested at crosshead speed of 1 mm/min. The data was analyzed using one way ANOVA and Tukey's test. Scanning electron microscopy analysis was made to examine the details of the bonding interface, 1. Group 1 showed significantly lower ${\mu}TBS$ than other groups (p<0.05). 2. There was no significant difference between the ${\mu}TBS$ of Group 3 and Group 5. 3. The ${\mu}TBS$ of Group 4 showed significantly lower than that of Group 2 (p<0.05). In conclusion, a desensitizer (Isodan) might have an adverse effect on the bond strength of composite resin inlay to dentin.

Comparison of Microleakage and Compressive Strength of Different Base Materials (여러 치과 와동 기저재용 재료들의 미세누출 및 압축강도 비교)

  • Jang, Eunyeong;Lee, Jaesik;Nam, Soonhyeun;Kwon, Taeyub;Kim, Hyunjung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.168-175
    • /
    • 2021
  • This study compared the microleakages and compressive strengths of various base materials. To evaluate microleakages, 50 extracted permanent premolars were prepared. The teeth divided into 5 groups of 10 each according to the base materials. Cavities with a 5.0 mm width, 3.0 mm length, and 3.0 mm depth were formed on the buccal surfaces of the teeth. After filling the cavities with different base materials, a composite resin was used for final restoration. Each specimen was immersed in 2% methylene blue solution and then observed under a stereoscopic microscope (× 30). To evaluate the compressive strength, 5 cylindrical specimens were prepared for each base material. A universal testing machine was used to measure the compressive strength. The microleakage was highest in the Riva light cureTM group and lowest in the BiodentineTM and Well-RootTM PT groups. For the compressive strengths, in all groups, acceptable strength values for base materials were found. The highest compressive strength was observed in the Fuji II LCTM group and the lowest strength in the Well-RootTM PT group.

Review of the Literature on Level of Biological Exposure and Trends in Possible and Probable Occupational Disease among Chromium Workers (크롬 직업병 유소견자와 요관찰자 추이 및 취급 근로자의 생물학적 노출수준 고찰)

  • Park, Sang-il;Kim, Nam-Soo;Hwangbo, Young;Kim, Hwa-Sung;Lee, Sung-Soo;Kim, Yong-Bae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.3
    • /
    • pp.213-225
    • /
    • 2021
  • Objectives: This study identifies the trends in possible and probable occupational disease among chromium workers and reviews the literature on domestic and foreign chromium workers to review the industries, biological exposure levels, and major results. Methods: The results of the Ministry of Employment and Labor's special health-screening program for hazard agents among workers from 2009 to 2019 were used. Also, the industries, biological exposure levels, and major results on chromium workers were reviewed using PubMed and RISS. Results: The average annual proportion of both possible and probable occupational disease for chromium workers has recently increased. The average annual proportion of possible and probable occupational disease that can occur was high for both men and women in their 60s or older by age and 10 to 14 years by work duration. By industry, possible occupational disease showed high in manufacturing. In the literature review, many electroplating-related chromium-workers reported high levels of exposure to blood and urine chromium, as did dental technicians; tannery, tile factory or glass mill workers; cement workers; and sodium bichromate workers. Furthermore, a number of main findings in recent studies have reported that chromium exposure is related to genetic toxicity among workers. Conclusions: In this study, the average annual rate of both possible and probable occupational disease in domestic chromium workers is increasing, and a body of literature shows that chromium exposure is related to genetic toxicity and associated indicators among workers, which requires more systematic study.

Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study (내측연결형 임플란트에 체결한 지대주의 수직침하에 대하여 반복하중이 미치는 영향)

  • Seol, Hyon-Woo;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • Purpose: To evaluate the axial displacement of implant-abutment assembly after cyclic loading in internal tapered connection system. Materials and methods: External butt-joint connection implant and internal tapered connection implant were connected with three types of abutment for cement-retained prostheses, i.e. external type abutment (Ext group), internal tapered 1-piece abutment (Int-1 group), and internal tapered 2-piece abutment (Int-2 group). For each group, 7 implants and abutments were used. The implantabutments assemblies were clamped into the implant holder for vertical loads. A dynamic cyclic loading was applied for $150{\pm}10N$ at a frequency of 4 Hz. The amount of axial displacement of the abutment into the implant was calculated at each cycle of 0, 5, 10, 50, 100, 1,000, 5,000, and 10,000. A repeated measures analysis of variance (ANOVA) for the overall effect of cyclic loading and the pattern analysis by linear mixed model were used for statistical analysis. Differences at P<.05 were considered statistically significant. Results: The mean axial displacement after 10,000 cycles were $0.714{\pm}0.488{\mu}m$ in Ext group, $5.286{\pm}1.604{\mu}m$ in Int-1 group, and $11.429{\pm}1.902{\mu}m$ in Int-2 group. In the pattern analysis, Int-1 and Int-2 group showed continuous axial displacement at 10,000 cycles. There was no declining pattern of axial displacement in the Ext group. Conclusion: The pattern of linear mixed model in Ext group showed no axial displacement. There were continuous axial displacements in abutment-implant assemblies in the Int-1 and Int-2 group at 10,000 cycles. More axial displacement was found in Int-2 group than in Int-1 group.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.