• Title/Summary/Keyword: Density of Odor

Search Result 46, Processing Time 0.026 seconds

Applicability Investigation for the Odor Source Tracking Approach using the Wind Field and the Fingerprinting (바람장 및 Fingerprint를 이용한 악취추적기법 활용가능성 평가)

  • Na, Kyung-Ho;Bak, Yong-Chul;Jang, Young-Gi
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.1-13
    • /
    • 2007
  • This study was carried out to evaluate the applicability of the odor source tracking using wind field and fingerprint as a solution tool. First of all, CALMET and HYSPLIT modeling system, and database of odor discharge companies were utilized to track odor from industrial complexes. Secondly, industrial odor fingerprint was made by listing on the 19 domestic industries, and compared with foreign data to assess the representative, and thus the similarity was 86.7%. On the modeling experiment, Sihwa industrial complex did not show any difference because the matching rates of day and night were 49.5% and 50.0%, respectively. However, the Banwol and Sihwa industrial complexes did show some differences due to odor facility density. Separately, in this study, odor samples were obtained from 10 odor discharging companies, located in the Sihwa and Banwol industrial complexes, They were compared with the results of odor tracking modeling. The matched companies were 4 of 10 by three cases of tracking, while the fingerprint and industry of odor monitoring networks and companies matched each other. Therefore, this study confirmed the approach applicability of source tracking system using the fingerprint.

A Study on the Effect of Abelmoschus Manihot Jinhuakui Extract on Odor Reduction

  • Gok Mi Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.1
    • /
    • pp.281-286
    • /
    • 2024
  • With the commercialization and full-timeization of the livestock industry, civil complaints continue to increase, and the livestock industry is facing a crisis due to social problems such as odor caused by livestock manure, soil pollution, water pollution, and environmental pollution. In order to increase productivity in livestock farms, the amount of livestock manure generated is increasing due to excessive use of protein feed and high-density breeding environment, and complaints such as odor and water pollution due to management problems are increasing rapidly. Livestock odor has emerged as a serious social problem, and due to growing complaints, conflicts between the Ministry of Agriculture and Forestry and the Ministry of Environment are even causing the livestock industry to lower its status. There is an urgent need for solutions to identify problems in the livestock industry and improve policies. This study aims to develop a " Abelmoschus Manihot Jinhuakui " brand that can improve the intestinal environment of livestock, reduce odors caused by livestock excrement, and improve the productivity of livestock farms in order to improve the increasingly serious odor problem in livestock sites. For Jeju livestock farms, which place more importance on the environment by securing tourists, eco-friendly feed additives were applied to the experiment, the results were derived, and the focus was on solving fundamental problems of odor generation through the development and packaging of feed additive brands. We aim to fundamentally solve the odor problem of domestic livestock farms, secure eco-friendly livestock farms, and contribute to reducing livestock odors and increasing productivity through research results that reduce ammonia levels in each livestock farm.

A Study on the Odor Removal Control System of Sewage Sludge

  • KIM, Su-Hye;LEE, So-Hee;YUN, Yeo-Jin;CHOI, Soo-Young;JUNG, Min-Jae;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.2
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

Reduction of the Offensive Odor from Confectionery Wastewater Plant (제과공장의 폐수처리장에서 발생하는 악취 저감)

  • 김영식;손병현;조상원;정종현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

A Study on the Characteristics and Distribution of the Time-Spatial Occurrence of Offensive Odors -Gangwon Province - (악취의 시공간적 발생 특성 및 분포도 분석 - 강원지역을 대상으로 -)

  • Kim, Byoung-Ug;Hyun, Geun-Woo;Bae, Sun-Hak;Hong, Young-Kyun;Lee, Yeong-Seob;Yi, Geon-Ho;Huh, In-Ryang;Choi, Seung-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.376-387
    • /
    • 2020
  • Objectives: This study is aimed at offering basic data for making plans for offensive odor management after researching offensive odor occurrence and characteristics in Gangwon Province. Methods: The data used in the study is based on offensive odor data analyzed by the Gangwon Institute of Health and Environment from 2012 to 2019. The data were reclassified by year, month, facility, and region to identify characteristics of occurrence. Finally, a distribution map of offensive odors was created using ArcGIS. Results: The highest monthly frequency of offensive odor occurrence falls in June, August, and July, and the summer season and third quarter are the highest. According to the latest eight-year data for Gangwon Province, complaints about offensive odors in county areas are more frequent than those in city areas. There are many offensive odor complaints in Wonju, Cheorwon, and Heongsung. The main offensive odor emission facilities are livestock and waste treatment (recycling) facilities. Complaints about offensive odors are relatively lower the Yeongdong area than Yeongseo area, which is considered to be the result of characteristics of land-sea breezes and geographical factors. Offensive odors from livestock facilities count for an average of 53.9% of the total, and the inadequacy rate of livestock facilities averages 36.9%. Conclusions: To maintain a clean environment in Gangwon Province, it is strongly recommended that an offensive odor reduction plan for livestock facilities be established. Areas with a high density of offensive odor occurrence should be identified and systematically managed with short- and mid-term measures. If offensive odors is managed using GIS, it is possible to identify the characteristics of occurrence by time and space and also by facility. In addition, since systematic data management is possible, it is believed that a rapid response to offensive odors, prediction of their spread, and efficient management are possible.

A Study about Improvement of Multiple Odor of Public Toilet (Dong-gu, Daejeon) (공중화장실 복합악취 및 개선에 관한 연구 (대전광역시 동구))

  • Jo, Soo-Jun;Shin, Je-Youn;Oh, Sang-Soo;Yu, Dae-Yong;Lee, Sung-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.240-245
    • /
    • 2015
  • This study aimed to provide the basic data to establish measures for the management of the public toilets and reduction of the offensive odor through the air dilution olfactory method and instrumental analysis about offensive odor dilution rate of public toilets, focusing on the Dong-gu, Daejeon Metropolitan City, Korea. The offensive odor intensities ranged from 10 degree to 669 degrees in the urinal toilets and from 31 to 464 in closet bowl toilets. Meanwhile, toilets that had offensive odor of more than 2.5, of which a civil complaint can be filed, were researched 6 (33%). Offensive odor intensities were different according to the closet bowl toilets of the flush, fermented and conventional methods and the year of their installation, but not according to the area of the toilets. As a result of the instrumental analysis targeting 6 public toilets to identify the offensive odor substance, the maximal concentration of $NH_3$ was 2.04 ppm and the average concentration was 0.67 ppm, but $H_2S$, $CH_3SH$ and $(CH_3)_3N$ were not detected. In the fermented and conventional public toilets were not soaps, air fresheners and wastebaskets. Just 50% of the flush toilets had toilet tissue.

Effect of Inorganic Nanocomposite Based Liners on Deodorization of Kimchi

  • Chung, Kwon;Park, Hyun Jin;Shin, Yang Jai
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.27 no.2
    • /
    • pp.55-62
    • /
    • 2021
  • This study aims to reduce the rancid odor generated during the fermentation process of kimchi by inserting zinc oxide (ZnO) into an inorganic porous material with a high surface area to decompose or adsorb the fermentation odor. ZnO activated by the presence of moisture exhibits decomposition of rancid odors. Mixed with Titanium dioxide (TiO2), a photocatalyst. To manufacture the packaging liner used in this study, NaOH, ZnCl2, and TiO2 powder were placed in a tank with diatomite and water. The sludge obtained via a hydrothermal ultrasonication synthesis was sintered in an oven. After being pin-milled and melt-blended, the powders were mixed with linear low-density polyethylene (L-LDPE) to make a masterbatch (M/B), which was further used to manufacture liners. A gas detector (GasTiger 2000) was used to investigate the total amount of sulfur compounds during fermentation and determine the reduction rate of the odor-causing compounds. The packaging liner cross-section and surface were investigated using a scanning electron microscope-energy dispersive X-ray spectrometer (SEM-EDS) to observe the adsorption of sulfur compounds. A variety of sulfur compounds associated with the perceived unpleasant odor of kimchi were analyzed using gas chromatography-mass spectrometry (GC-MS). For the analyses, kimchi was homogenized at room temperature and divided into several sample dishes. The performance of the liner was evaluated by comparing the total area of the GC-MS signals of major off-flavor sulfur compounds during the five days of fermentation at 20℃. As a result, Nano-grade inorganic compound liners reduced the sulfur content by 67 % on average, compared to ordinary polyethylene (PE) foam liners. Afterwards SEM-EDS was used to analyze the sulfur content adsorbed by the liners. The findings of this study strongly suggest that decomposition and adsorption of the odor-generating compounds occur more effectively in the newly-developed inorganic nanocomposite liners.

Removal of nitrogen and sulfur odorous compounds and their precursors using an electrolytic oxidation process (산화전리수를 이용한 질소와 황 계열 악취 및 악취전구물질의 제거)

  • Shin, Seung-Kyu;An, Hea-Yung;Kim, Han-Seung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.223-230
    • /
    • 2011
  • An electrolytic oxidation process was applied to remove odorous compounds from non-point odor sources including wastewater pipelines and manholes. In this study, a distance between the anode and the cathode of the electrolytic process was varied as a system operating parameters, and its effects on odor removal efficiencies and reaction characteristics were investigated. Odor precursors such as sediment organic matters and reduced sulfur/nitrogen compounds were effectively oxidized in the electrolytic process, and a change in oxidation-reduction potential (ORP) indicated that an stringent anaerobic condition shifted to a mild anoxic condition rapidly. At an electrode distance of 1 cm and an applied voltage of 30 V, a system current was maintained at 1 A, and the current density was 23.1 $mA/cm^{2}$. Under the condition, the removal efficiency of hydrogen sulfide in gas phase was found to be 100%, and 93% of ammonium ion was removed from the liquid phase during the 120 minute operating period. Moreover, the sulfate ion (${SO_4}^{2-}$) concentration increased about three times from its initial value due to the active oxidation. As the specific power consumption (i.e., the energy input normalized by the effective volume) increased, the oxidation progressed rapidly, however, the oxidation rate was varied depending on target compounds. Consequently, a threshold power consumption for each odorous compound needs to be experimentally determined for an effective application of the electrolytic oxidation.

A Study on the Environmental Characteristic Analysis at Closed Small Sale Landfill Site (소규모 사용종료매립지의 환경특성분석)

  • Jang, Seong-Ho;Cho, Han-Jin;Lee, Chun-Sik
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.901-905
    • /
    • 2010
  • Emissions of leachate, odor, and landfill gas(LFG) from an open-dumping landfill site do harm to public health by contaminating neighboring soil, underground water, and rivers. Particularly, methane($CH_4$) and carbon dioxide($CO_2$), the main components of LFG, are especially noted as the causing material of the global warming that become seriously recognized worldwide issue. As one of alternatives in managing LFG, incineration of inflammable wastes that are generated during excavation process at an open-dumping landfill has been evaluated. Standard on stabilization for evaluation, neither $CH_4$ density nor $CO_2$ density could not Because meet 'less than 5%' criterion and so it is right to install a gas collection system during landfill renewal to prevent diffusion of odor and collect it. Because it shows considerable heating value, incineration of inflammable wastes might be the reasonable solution from the result of our study.

Developmemt of Rice Husk Pellets as Bio-filter Media of Bio Scrubber Odor Removal System (왕겨펠렛 생물담체 개발 및 이를 이용한 bio scrubber형 악취제거 시스템 성능평가)

  • Bae, Jiyeol;Han, Sangjong;Park, Ki Ho;Kim, Kwang-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.554-566
    • /
    • 2018
  • The rice husk contains nutrients which can be easily utilized by microorganisms, and also has a water retaining ability, which played a crucial part in enabling it to become a biofilter media. In this study, we evaluated the applicability of rice husk pellet bio-scrubber as a microbiological carrier. The pelletization experiment of rice husk as a biological media was performed using PVA and EVA binder. Also, the feasibility tests of rice husk as a biological media for odor removal were carried out in order to know whether rice-husk contains useful components as a media for microbiological growth or not. Lastly, a combined test for odor gas absorption and biological oxidation was conducted using a lab scale bio-filter set-up packed with rice-husk pellets as wet-scrubber. The major components of the rice husk were carbon, hydrogen, nitrogen, and oxygen, while carbon acted as the main ingredient which comprised up to 23.00%. The C : N : P ratio was calculated as 45 : 1 : 2. Oxygen uptake rate, yield and decay rate of the rice husk eluent was calculated to be $0.0049mgO_2/L/sec$, 0.24 mgSS/mgCOD and 0.004 respectively. The most stable form of rice husk pellets was produced when the weight of the rice husk, EVAc, PVAc, and distilled water was 10 : 2 : 0.2 : 10. The prepared rice husk pellets had an apparent density of 368 g/L and a porosity of 59.00% upon filling. Dry rice husks showed high adsorption capacity for ammonia gas but low adsorption capacity for hydrogen sulfide. The bio-filter odor removal column filled with rice husk pellets showed more than 99.50% removal efficiency for NH3 and H2S gas. Through the analysis of circulation water, the prime removal mechanism is assumed to be the dissolution by water, microbial nitrification, and sulfation. Finally, it was confirmed that the microorganisms could survive well on the rice husk pellets, which provided them a stable supply of nutrients for their activity in this long-term experiment. This adequate supply of nutrients from the rice husk enabled high removal efficiency by the microorganisms.