• Title/Summary/Keyword: Density fluctuation

Search Result 257, Processing Time 0.019 seconds

Method of Minimizing ESS Capacity for Mitigating the Fluctuation of Wind Power Generation System (풍력발전의 출력 변동 저감을 위한 ESS 최소용량 산정기법)

  • Kim, Jae-Hong;Kang, Myeong-Seok;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.119-125
    • /
    • 2011
  • In this paper, we have studied about minimizing the Energy Storage System (ESS) capacity for mitigating the fluctuation of Wind Turbine Generation System (WTGS) by using Electric Double Layer Capacitor (EDLC) and Battery Energy Storage System (BESS). In this case, they have some different characteristics: The EDLC has the ability of generating the output power at high frequency. Thus, it is able to reduce the fluctuation of WTGS in spite of high cost. The BESS, by using Li-Ion battery, takes the advantage of high energy density, however it is limited to use at low frequency response. To verify the effectiveness of the proposed method, simulations are carried out with the actual data of 2MW WTGS in case of worst fluctuation of WTGS is happened. By comparing simulation results, this method shows the excellent performance. Therefore, it is very useful for understanding and minimizing the ESS capacity for mitigating the fluctuation of WTGS.

Effect of groundwater fluctuation on load carrying performance of shallow foundation

  • Park, Donggyu;Kim, Incheol;Kim, Garam;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.18 no.6
    • /
    • pp.575-584
    • /
    • 2019
  • The groundwater level (GWL) is an important subsoil condition for the design of foundation. GWL tends to fluctuate often with seasonal variation, which may cause unexpected, additional settlements with some reductions in the safety margin of foundation. In this study, the effects of fluctuating GWL on the load carrying and settlement behavior of footing were investigated and quantified. A series of model load tests were conducted for various GWL and soil conditions using a hydraulically-controlled chamber system. Changes in load level and rising and falling GWL fluctuation cycle were considered in the tests. Settlements during GWL rise were greater than those during GWL fall. The depth of the GWL influence zone ($\underline{d}_{w,inf}$) varied in the range of 0.3 to 1.5 times footing width and became shallower as GWL continued to fluctuate. Design equations for estimating GWL-induced settlements for footings were proposed. The GWL fluctuation cycle, load level and soil density were considered in the proposed method. Changes in settlement and factor of safety with GWL fluctuation were discussed.

The Characteristics of Elutriation with Gaussian Particle Size Distributions in a gas-solid fluidized bed (기-고 유동층에서 Gaussian 분포 입자군의 표준편차에 따른 유출 특성)

  • Jang, Hyun-Tae;Cha, Wang-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3274-3279
    • /
    • 2009
  • The elutriation characteristics of particle size distribution were investigated in a gas-solid fluidized bed. Experiments were carried out with the mulit-sized particles of Gaussian distributions. The elutriation rate constant obtained from the experiment was correlated with the standard deviation of particle size and the dimensionless group of the velocity ratio. The standard deviation of pressure fluctuation, mean pressure, major frequency and power spectrum density function were calculated by pressure fluctuation properties. Size distribution of elutriated particles and pressure fluctuations were measured for the particle size distribution of particle system depended largrly on the size distribution. Characteristics of fluidization and elutriation were greatly influenced by the particle size distribution and these characteristics could be interpreted with pressure fluctuation properties.

A Study on the Subcooled Boiling Heat Transfer in a Horizontal Tube (수평관내 냉매의 과냉비등열전달에 관한 연구)

  • 김종헌;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.26-33
    • /
    • 1994
  • A new reliable method to prediet the axial vapor fraction distribution from the measured probability density of the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled boiling flow is easily calculated from the liquid bulk temperature. When the heat generating rate is reached to the CHF value, the sharp wall temperature increasing by the wall temperature fluctuation is occurred under the CHF condition. This paper presents the simple wall temperature fluctuation model of transition boiling by the repeating process of overheating and quenching, when the coalescent bubble passes slowly near the wall. Experiments for the subcooled R-113 flow are carride-out in the range of(0.9399~4.461)${\times}10^6$kg/$m^2$hr mass velocity and 10~3$0^{\circ}C$ intel subcooling condition.

  • PDF

Studies on the Seasonal Occurrences and Several Insecticides for Control of the Mulberry Thrips, Pseudodendrothrips mori NIWA(Thysanoptera: Phloeothripidae) (뽕나무 총채벌레의 발생소장과 수종살충제 처리효과)

  • 백현준
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.2
    • /
    • pp.61-64
    • /
    • 1976
  • Experiments had been carried out in Suweon area from 1972 to 1973 to determine the seasonal fluctuation of Pseudodendrothrips mori NIWA using direct counts and to know the effects of chemicals for its control. 1. The fluctuation of mulberry thrips was especially influenced by precipitation and number of hours with sunshine in the meteological conditions. The peaks of fluctuation occurred several times but the highest peak occurred in late August. 2. The mulberry thrips was distributed in the range of the 4th to 16th leaves from the apex in a branch. The highest density leaves were 6th to 12th. 3. Orthene, Metasystox were the most effects on the mulberry thrips.

  • PDF

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

Electrical Characteristics of $Nb/Al-AlO_x/Nb$ Tunnel Junction fabricated with $I_c$ Values in the Range of $28 A/cm^2~ 940 A/cm^2$ ($28 A/cm^2~ 940 A/cm^2$의 임계전류밀도 범위로 제작된 $Nb/Al-AlO_x/Nb$ 터널접합의 전기적 특성)

  • 홍현권;김규태;박세일;김구현;남두우
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.4-7
    • /
    • 2002
  • Samples of $Nb/Al-AlO_x/Nb$ tunnel junction with the size of $50 ${\mu}{\textrm}{m}$ {\times} 50 ${\mu}{\textrm}{m}$$ were fabricated by using self-aligning and reactive ion etching technique In the high quality samples, the $V_m$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density of $J_c: 500 A/cm^2 and the V_g$ value (the gap voltage) was 2.8 mV. For the higher $J_c$ sample, voltage fluctuation at the gap voltage was observed. The $V_m and J_c$ values for this sample were 8 mV and 900 A/cm$^2$, respectively. Also, the relationship between critical current density $J_c$ and specific normal conductance $G_s$ of the junctions with $J_c$ in the range of 28 A/cm$^2$~940 A/cm$^2$was investigated.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation on a Heat Exchanger Circular Tube (열교환 단일 원관의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.35-40
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. The present study examined the results of the previous experimental researches for the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared from the present CFD analysis. For the previous mentioned purpose, the present CFD analysis introduced a single circular cylinder and calculated with the unsteady laminar flow over the cylinder. The characteristics of vortex shedding and lift and drag fluctuation over the cylinder was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift and drag PSD over a single circular cylinder was established from the present CFD study.

Secular chang of density, litterfall, phytomass and primary productivity in mongolian oak(quercus mongolica)forest (신갈나무 숲의 林木密度, 落葉量, 植物量 및 1次 純生産量의 經年 變化)

  • Kwak, Toung-Se;Kim, Joon-Ho
    • The Korean Journal of Ecology
    • /
    • v.15 no.1
    • /
    • pp.19-33
    • /
    • 1992
  • The density, litterfall, phytomass, and primary productivity for 7 years in quercus mongolian forest locasted at mt. nambyengsan, pyeongchang-gun, gangwon provance in central part of korean peninsula were estimated quantitatively. at the first year in 1984, a stand had 1, 450 trees/ha in tree density, which was 0.67 of skewness and 0.54 of kurtosis in frequency distribution, however, at the 7th year in 1990, the stand had 1, 133 trees/ha in the density with 22%(or 316 tree/ha)in mortality, which was 1.16 of skewness and 1.89 of kurtosis in the frequency. annual mean litterfall was 5 ton DM/ha, which was composed of 68% of leaves, 17% of branches, 3% of bud scales, 9% of arcons and cups, 0.7% of flowers and others. the phytomass of tree layer for 7 years was gradually increased from 149.7 ton DM/ha at the first year to 188.5 ton DM/ha at the 7th year.annual net productivity for the tree layer studied ranged from 8.76 ton DM/ha.yr-1 to 11.62 ton DM/ha. yr-1 with heavy fluctuation year by year. average annual productivity of the stand of trunk, branches, leaves and roots for 7 years were 4.42, 0.67, 3.85 and 1.29 ton DM/ha.yr-1, respectively. turnover rate of the stand was 6.9% at the first year and 5.6% at the 7th year. such fluctuation of the productivity was caused by the chang of density, mortality, mortality and turnover rate.

  • PDF