• 제목/요약/키워드: Density Test

검색결과 3,875건 처리시간 0.03초

3D 프린팅을 이용한 P LA+ 소재의 채움 패턴 및 밀도 변화에 따른 인장강도 연구 (A Study on Tensile Strength Dependent on Variation of Infill Pattern and Density of PLA+ Material Using 3D Printing)

  • 나두현;김현준
    • 소성∙가공
    • /
    • 제31권5호
    • /
    • pp.281-289
    • /
    • 2022
  • Presently, 3D printers manufactured by material extrusion are economical and easy to use, so they are being used in various fields. However, this study conducted a tensile test on the infill pattern and density of the PLA+ material, due to the limitations of long printing time as well as low mechanical strength. The infill area for the infill density change was measured, using a vision-measuring machine for four infill patterns (concentric, zigzag, honeycomb, and cross) in which the nozzle path was the same for each layer. The tensile strength/weight[MPa/g] and tensile strength/printing time[MPa/min] of the tensile specimens were analyzed. In this study, efficient infill density and patterns are suggested, for cost reduction and productivity improvement. Consequently, it was confirmed that the infill area and infill percentage of the four patterns, were not constant according to the infill pattern. And the tensile strength of the infill density 40% of the honeycomb pattern and infill density 20% of the cross pattern, tended to highly consider the weight and printing time. Honeycomb and cross patterns could reduce the weight of the tensile specimen by 19.11%, 28.07%, as well as the printing time by 29.56%, 52.25%. Tensile strength was high in the order of concentric, zigzag, honeycomb, and cross patterns, considering the weight and printing time.

Emission test of a domestic fabricated cathode with higher current density

  • 주영도;공형섭;김승환;;석영은;이병준;홍용준;신진우;소준호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.205.2-205.2
    • /
    • 2016
  • The emission test a domestic fabricated cathode is conducted using an easy-replaceable-emitter-type test bench. A simple cylindrical button type cathode is dropped vertically into a cathode cup holder. The cathode is heated by a tungsten wire heater located around the cup holder. The cathode temperature is measured by an optical pyrometer. A high voltage pulse power supply gives the anode-cathode gap voltage up to 20 kV with the pulse width of 15 us. The emitted current from the cathode is captured at a faraday cup and is measured using current transformer and oscilloscope. The test bench is installed in the vacuum chamber with easy access door and, therefore, the cathode can be easily replaceable. We confirmed the emission current density of $15A/cm^2$ and $80A/cm^2$ with a domestic fabricated B-type cathode and a Scandate cathode, respectively. The detailed test result for the cathode will be presented.

  • PDF

방염도료의 방염성능 및 발연특성에 관한 연구 (A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint)

  • 김황진;이성은;오규형
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.78-83
    • /
    • 2009
  • 방염도료의 주성분 및 특성에 따른 방염성능과 발연특성에 대하여 알아보기 위하여 국내에 유통되어지는 17종의 방염도료를 MDF에 방염처리하여 45도 연소실험과 연기밀도실험을 실시하였다. 45도 연소실험 결과 주성분별로는 아크릴 수지를 주성분으로 한 방염도료의 방염성능이 가장 우수한 것으로 평가되어지며 유성방염도료 보다는 수성방염도료의 방염성능이 우수한 것으로 나타났고 또한 무광방염도료보다 유광방염도료의 방염성능이 더 우수한 것으로 평가되었다. 연기밀도실험을 통한 발연특성은 아크릴 수지를 주성분으로 한 시료에서 연기밀도가 상대적으로 낮게 측정되었으며 특성별로는 수성방염도료를 처리한 시료들에서 유성방염도료를 칠한 시료보다 연기밀도가 낮게 측정되었다.

방사선측정치를 이용한 아스콘 포장 및 노상의 현장밀도와 함수비 측정에 관한 연구 (A Study on the Determination of Density and Moisture Content of Asphalt Concrete Pavement and Subgrade Using Nuclear Density Meter)

  • 진성기;도덕현
    • 한국농공학회지
    • /
    • 제36권4호
    • /
    • pp.103-116
    • /
    • 1994
  • The objective of this study was to determine the criteria for density and moisture content measurements made with a nuclear density meter on common materials in the construction field. The study also sought to test a full-type nuclear density meter in controlling the density of overlay layers( 2.5~5.0cm). In order to determine the accuracy and reliablility of nuclear guage measurements made on construction materials, laboratory and field tests were conducted. Wooden blocks( 65 x 45 ${\times}$ 50 cm) and a special steel compactor( 4.7kg) were constructed in order to carry out tests which were conducted on three different materials; coarse gramed soil, fine grained soil, and AC material. Throughout all laboratory and field tests, the nuclear density and moisture content were determined using Humboldt 5OOLP nuclear gauge. The tests on subgrade material entailed obtaining density measurements by means of both the sand replacement method and the nuclear density meter. The results of the sand replacement method were then compared to the readings recorded bu the meter. As in the subgrade material tests, density measurements made during AC pavement tests were also determined using the unclear meter in addition to a second means; through the core method. The meter readings and core densties were compared as was done in the tests on subgrade materials. The correlation between the results of the sand replacement test( also, the core method) and meter readings on subgrade material was then determined. Sirnilarly, the observed results were then analyzed through linear regression. The tests to determine thin-lift density by means of a full-type nuclear density meter also conducted on the overlay layers( about 4. 8cm thickness) above AC pavements at road construction sities in Korea.

  • PDF

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2002년도 제3회 최신 분말제품 응용기술 Workshop
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

Nutritional Status and Bone Mineral Density of Elderly Women in Asan

  • Kim Ji Sun;Kwon Young Suk;Shin Yoon Jeong;Kim Min Kyung;Kim Hee Seon
    • Journal of Community Nutrition
    • /
    • 제7권1호
    • /
    • pp.49-57
    • /
    • 2005
  • Nutrition factors play an important role in the pathogenesis of osteoporosis. The purpose of this study is to investigate the relationship between nutritional status and bone mineral density of elderly women. Three hundred thirty five elderly women (over 65 years) in Asan were divided into three age groups (group 1, less than 70 y ; group 2, from 70 to 75 y ; group 3, 75 y or more). Total alkaline phosphatase and serum calcium (Ca) were analyzed using spectrophotometric procedure. Data for food and nutrient intakes were obtained by a 24-hour recall method. Bone density was measured by broadband ultrasound attenuation (BUA) using QUS-2. Age differences were tested with the X 2 test for categorical variables and with ANOVA and Tukey's test for continuous variables. Correlation was conducted to test the association between bone density and nutrient intake. The subjects in age groups 1,2 and 3 were $36.7\%$, $32.8\%$ and $30.4\%$, respectively. Height and body weight of the subjects were significantly decreased with age. Average bone density of the subjects in group 3 was lower than the other age groups. Osteoporosis determined by t-score is $17.9\%$ for group 1, $24.5\%$ for group 2 and $55.9\%$ for group 3 (p < 0.001). The serum Ca level of the subjects in group 2 was significantly lower than that of group 1 although mean values in all age groups are within the normal range. Dietary Ca intake, nutrient adequacy ratio (NAR) and index of nutrient quality (INQ) were decreased with age. Bone density was negatively correlated with age (p < 0.001), while body mass index (p < 0.01) was positively related with bone density. Although partial correlation did not reveal the significant correlation of BMD and dietary calcium after controlling for age, since calcium intake was very poor compared to sodium and phosphorous intakes, recommendation of more calcium intake for elderly women especially those over 75 years must be continuously emphasized.

단일 및 혼합모드하에서 304스테인리스강의 피로균열 진전속도와 방향특성 (Fatigue Crack Growth Rates and Directions in STS304 under Mode I and Mixed Mode)

  • 권종완;양현태
    • 한국공작기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.102-109
    • /
    • 2002
  • The fatigue crack growth under mixed mode condition has been discussed within the scope of linear fracture mechanics such as maximum tangential stress, maximum tangential principal stress and minimum strain energy density. The purpose of this study is to investigate the characteristics of fatigue test crack growth in 304 stainless steel under mixed node. The fatigue test results carried out by using inclined pre-crack specimens was compared to both of the theoretical predictions of the criteria, maximum tangential stress and stain energy density. As difference from theoretical analysis, the transition region from mixed mode to mode I appeared in the fatigue test. There is deep relationship between the angle of slanted pre-crack and transition. Therefore, as applying the different stress intensity factor to each node I+II and mode I, the directions and rates of fatigue crack growth are evaluated more accurately under mixed mode.

골밀도가 저하된 폐경 후 성인여성의 뇨중 불소농도와 치주조직과의 관계 (The Urinary Fluoride Concentration and Periodontal Condition in Postmenopausal Osteoporotic Women)

  • 김영준
    • Journal of Periodontal and Implant Science
    • /
    • 제29권4호
    • /
    • pp.837-846
    • /
    • 1999
  • There were few reports about the fluoride concentration in bone and osteoporotic women. This study was designed to evaluate the relationship between the urinary fluoride concentration and periodontal condition in osteoporotic old women. Twentyeight postmenopausal women(Test group) and twenty-one premenopausal women(Control group) were examined. Bone mineral density(BMD) of lumbar spine(L2-L4) was measured by dual energy X-ray absorptiometry(DEXA). The urine samples were collected at early morning and determined with the help of a fluoride-specific electrode and Tisabbufferd samples. The results were as follows. 1. The mean urinary fluoride concentration in test and control group showed statistically no difference. 2. The bone mineral density(BMD) of the spine in test group was significantly lower than control group(p<0.05). 3. The significant negative correlation was found between BMD level and age after menopause $(p<0.001,\;{\gamma}=-0.526$. 4. The urinary fluoride concentration was not correlated with age, age after menopause and bone mineral density. 5. The urinary fluoride concentration was not correlated with periodontal condition.

  • PDF

고밀도 팽창흑연 성형품의 기계적 특성에 관한 연구(1) (A Study of Mechanical Properties on High Density Graphite Products with Expanded Graphite(1))

  • 신영우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.143-147
    • /
    • 2005
  • Graphites is well known to have superior advantages to high-temperature, high-pressured, and strong acid-state gas or liquid because it is very stable and chemical structure. Nowadays the new plant with high performance is developed in field of chemical industries, so the need of graphites is increasing rapidly. In this paper, newly developed graphite products with high density is investigated by the mechanical properties of that. I introduced the graphite material which developed for this experiment by the forming process in order to compare to the commercial graphite sheet from expanded graphite which made by the rolling process. Through measuring density and hardness test also tensile test, I investigated the characteristics of these materials. It is verified that the newly developed graphite products forming method is able to make graphite products which have superior mechanical properties than that of commercial graphite sheet.

  • PDF

인공 체액 조건에서 임플랜트용 티타늄 소재의 부식 특성 (Corrosion Behavior of Titanium for Implant in Simulated Body Fluids)

  • 이중배;최기열
    • 한국표면공학회지
    • /
    • 제37권2호
    • /
    • pp.110-118
    • /
    • 2004
  • The corrosion of pure titanium (CP- Ti Grade 2) and titanium alloy (Ti6Al4V ELI) were studied under various conditions of simulated body fluids. The static immersion test and the electrochemical test were performed in accordance with ISO 10271 : 2001. For the electrochemical test, the open circuit potential was monitored as a function of time, and the cyclic polarization curve was recorded. The corrosion resistance was evaluated from the values of corrosion potential, passivation current density, breakdown potential, and the shape of hysteresis etc. The effects of alloy type, surface condition, temperature, oxygen, and constituents in the fluids such as acid, chloride were estimated. Both specimens had extremely low dissolution rate in the static immersion test. They showed strong passivation characteristics in the electrochemical test. They maintained negligible current density throughout the wide anodic potential range. The passive layer was not broken up to 2.0 V (vs. SCE). The hysteresis and the shift of passivation potential toward the anodic direction was observed during the reversed scan. The passivation process appeared to be accelerated by oxygen in air or that dissolved in the fluids. The passivation also proceeded without oxygen by the reaction of constituents in the fluids. Acid or chloride in the fluids, specially later weakened the passive layer, and then induced higher passivation current density and less shift of passivation potential in the reversed scan. CP-Ti Grade 2 was more reactive than Ti6Al4V ELI in the fluids containing acid or chloride, but thicker layer produced on its surface provided higher corrosion resistance.