• 제목/요약/키워드: Density Current

검색결과 5,647건 처리시간 0.036초

고속도금된 Zn-Cr 및 Zn-Cr-X 3원합금 도금층의 표면조직, 광택도 및 경도 (Surface morphology, Glossiness and Hardness of Zn-Cr and Zn-Cr-X ternary alloy Electrodeposits)

  • 예길촌;김대영;서경훈
    • 한국표면공학회지
    • /
    • 제36권5호
    • /
    • pp.379-385
    • /
    • 2003
  • The surface morphology, the glossiness and the hardness of Zn-Cr and Zn-Cr-X(X:Co, Mn) alloy electrodeposits were investigated by using chloride bath with EDTA additive and flow cell system. The surface morphology of Zn-Cr alloy and Zn-Cr-Mn alloy changed from fine needle shape crystalline structure to colony structure of fine granular crystallites with increasing current density in the range of 20-100 $A/dm^2$. The surface morphology of Zn-Cr-Co alloy deposited from low Co concentration bath(2.5-10 g/$\ell$) was similar to that of Zn-Cr alloy, while that of Zn-Cr-Co alloy deposited from high cobalt concentration bath was fine granular crystalline structure in the same range of current density. The glossiness of Zn-Cr and Zn-Cr-Mn alloy increased noticeably with increasing current density, while that of Zn-Cr-Mn alloy decreased with increasing Mn concentration of bath in high current density region. The glossiness of Zn-Cr-Co alloy deposited from low Co concentration bath increased with current density while that of the alloy from high Co concentration bath decreased with increasing current density. The hardness of Zn-Cr and Zn-Cr-X alloy increased noticeably with current density.

하구밀도류와 취송류가 영일만 해수유동에 미치는 영향 (Numerical Prediction of Tidal Current due to the Density and Wind-driven Current in Yeong-il Bay)

  • 윤한삼;이인철;류청로
    • 한국해양공학회지
    • /
    • 제18권5호
    • /
    • pp.22-28
    • /
    • 2004
  • This study constructed a 3D real-time numerical model that predicts the water quality and movement characteristics of the inner bay, considering the characteristics of the wind-driven current and density current in estuaries, generated by the river discharge from the Hyeong-san river and oceanic water of the Eastern sea. The numerical model successfully calculated the seawater circulation current of Yeong-il Bay, using the input conditions oj the real-time tidal current, river discharge, and weather conditions during March 2001. This study also observed the wind-driven current and density current in estuaries that are effected by the seawater circulation pattern of the inner bay. We investigated and analyzed each impact factor, and its relationship to the water quality of Yeong-il bay.

Effect of Deposition Parameters on the Morphology and Electrochemical Behavior of Lead Dioxide

  • Hossain, Md Delowar;Mustafa, Chand Mohammad;Islam, Md Mayeedul
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권3호
    • /
    • pp.197-205
    • /
    • 2017
  • Lead dioxide thin films were electrodeposited on nickel substrate from acidic lead nitrate solution. Current efficiency and thickness measurements, cyclic voltammetry, AFM, SEM, and X-ray diffraction experiments were conducted on $PbO_2$ surface to elucidate the effect of lead nitrate concentration, current density, temperature on the morphology, chemical behavior, and crystal structure. Experimental results showed that deposition efficiency was affected by the current density and solution concentration. The film thickness was independent of current density when deposition from high $Pb(NO_3)_2$ concentration, while it decreased for low concentration and high current density deposition. On the other hand, deposition temperature had negative effect on current efficiency more for lower current density deposition. Cyclic voltammetric study revealed that comparatively more ${\beta}-PbO_2$ produced compact deposits when deposition was carried out from high $Pb(NO_3)_2$ concentration. Such compact films gave lower charge discharge current density during cycling. SEM and AFM studies showed that deposition of regular-size sharp-edge grains occurred for all deposition conditions. The grain size for high temperature and low concentration $Pb(NO_3)_2$ deposition was bigger than from low temperature and high concentration deposition conditions. While cycling converted all grains into loosely adhered flappy deposit with numerous pores. X-ray diffraction measurement indicates that high concentration, high temperature, and high current density favored ${\beta}-PbO_2$ deposition while ${\alpha}-PbO_2$ converted to ${\beta}-PbO_2$ together with some unconverted $PbSO_4$ during cycling in $H_2SO_4$.

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • 제1권1호
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

Spatial and Statistical Properties of Electric Current Density in the Nonlinear Force-Free Model of Active Region 12158

  • 강지혜
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.46.1-46.1
    • /
    • 2016
  • The formation process of a current sheet is important for solar flare from a viewpoint of a space weather prediction. We therefore derive the temporal development of the spatial and statistical distribution of electric current density distributed in a flare-producing active region to describe the formation of a current sheet. We derive time sequence distribution of electric current density by applying a nonlinear force-free approximation reconstruction to Active Region 12158 that produces an X1.6-class flare. The time sequence maps of photospheric vector magnetic field used for reconstruction are captured by a Helioseismic and Magnetic Imager (HMI) onboard Solar Dynamic Observatory (SDO) on 10th September, 2014. The spatial distribution of electric current density in NLFFF model well reproduce observed sigmoidal structure at the preflare phase, although a layer of high current density shrinks at the postflare phase. A double power-law profile of electric current density is found in statistical analysis. This may be expected to use an indicator of the occurrence of a solar flare.

  • PDF

수치실험을 통한 금오열도 해역의 해수유동 특성 (Flow characteristics of Geumo Islands Sea area by numerical model experiments)

  • 추효상
    • 수산해양기술연구
    • /
    • 제58권2호
    • /
    • pp.159-174
    • /
    • 2022
  • Flow prediction was carried out through observational survey and three dimensional multi-layered numerical diagnostic model experiment to clarify the time and spatial structure of tidal current and residual flow dominant in the sea exchange and material circulation of the waters around Geumo Islands in the southern waters of Korea. The horizontal variation of tidal current is so large that it causes asymmetric tidal mixing due to horizontal eddies and the topographical effect creating convergence and dispersion of flow direction and velocity. Due to strong tidal currents flowing northwest-southeast, counterclockwise and clockwise eddies are formed on the left and right sides of the south of Sori Island. These topographical eddies are created by horizontal turbulence and bottom friction causing nonlinear effects. Baroclinic density flows are less than 5 cm/s at coastal area in summer and the entire sea area in winter. The wind driven currents assuming summer and winter seasonal winds are also less than 5 cm/s and the current flow rate is high in winter. Density current in summer and wind driven current in winter have a relatively greater effect on the net residual flows (tidal residual current + density current + density driven current) around Geumo Islands Sea area.

한계전류밀도 이상에서 전기투석공정의 운전 (Operation of Electrodialysis at Over Limiting Current Density)

  • 박진수;최재환;문승현
    • 멤브레인
    • /
    • 제12권3호
    • /
    • pp.171-181
    • /
    • 2002
  • 이온교환막의 전압-전류곡선의 plateau length를 결정하는 변수를 다양한 NaCl 농도와 유속 하에서 연구하였다. 또한, 한계전류밀도 이상의 전류에서 전기투석공정 운전의 타당성을 검토하기 위해 다양한 전류밀도의 전원을 공급하면서 0.1 M NaCl 용액의 탈염실험을 실시하여 이온의 제거효율, 전류효율, 에너지소비량, 물 분해 현상을 측정하였다. NaCl 용액의 농도와 유속이 감소하면서 확산경계층의 두께도 함께 감소하였으며, 본 확산경계층의 두께는 plateau length와도 밀접한 관련이 있는 것으로 나타났다. 탈염실험에서 측정된 이온 제거 효율 및 전류효율은 한계전류밀도 이상에서도 한계전류밀도 이하에서의 탈염실험과 크게 차이 나지 않은 것으로 보아 한계전류밀도 이상에서도 대부분의 전류는 이온교환막 표면의 물분해에 의한 것이 아니라 막을 통한 이온의 이동에 의한 것으로 사료된다. 한계전류밀도 이상에서의 탈염운전에 대한 에너지소비량은 plateau length의 영향으로 한계전류밀도 이하에서의 탈염운전 보다 다소 높지만, 한계전류밀도 이상에서는 전류밀도의 증가에도 에너지소비량이 증가하지 않았다. 이러한 결과들은 물분해 현상이 심각하게 일어나지 않는 한 한계전류밀도 이상에서도 매우 경제적으로 전기투석 공정을 운전찬 수 있다는 것을 제시해 주는 것이다.

낮은 최고전류밀도 조건에서 파형전류전해에 의한 Pb-Sn합금 전착층의 조성 및 조작특성 (Composition and microstructure of Pb-Sn alloy electrodeposits in pulse plating with low peak current density)

  • 예길촌;백민석
    • 한국표면공학회지
    • /
    • 제24권2호
    • /
    • pp.88-95
    • /
    • 1991
  • The tin-lead alloy was electrodeposited in the low range of peak current density in order to investigate the change of composition and microstructure of them. The Pb content of alloy deposits, which was decreased with increasing average current density, was relatively lower than that of D.C. plated alloy deposit. The preferred orientation of alloy deposit was changed with increasing peak current density and the surface morphology of alloy deposits was closely related to the preferred orientation of them.

  • PDF

765 kV 2회선 송전선 활선 작업자 인체내부 유도전류 밀도 해석 (Analysis on Current Density Induced Inside Body of Hot-Line Worker for 765kV Double Circuit Transmission Line)

  • 송기현;민석원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.231-238
    • /
    • 2006
  • This paper analysed the induced current density inside human body of hot-line worker for 765kV double circuit transmission line according to locations of human body. Human model was composed of several organs and other parts, whose shapes were expressed by spheroids or cylinders. Organs such as the brain, heart, lungs, liver and intestines were taken into account. Applying the 3 dimensional boundary element method, we calculated induced current density in case a worker was located inside and outside a lowest phase of 765 kV transmission line in which a 60% current of maximum load flowed. As results of study, we found a maximum induced current density in all organs was less than $10mA/m^2$ when a wonder was outside. As one in brain and heart was higher than $10mA/m^2$ when a worker was inside, we propose a method for lowering current density.

고속도금된 Zn-Cr 및 Zn-Cr-X 3원합금의 전류효율 및 조성 (Current Efficiency and Composit ion of Zn-Cr and Zn-Cr-X Ternary Alloy Electrodeposits)

  • 예길촌;김대영;안덕수
    • 한국표면공학회지
    • /
    • 제36권3호
    • /
    • pp.256-262
    • /
    • 2003
  • The current efficiency and the composition of Zn-Cr and Zn-Cr-X (X : Co, Mn) alloy electrodeposits were investigated by using chloride bath with EDTA auditive and flow cell plating system. The current efficiency of Zn-Cr alloy decreased with increasing current density, while it increased with the content of Co and Mn of the Zn-Cr-X alloy bath in high current density region. The Cr content in Zn-Cr alloy increased from 1.4-2.7 to $28wt\%$ with increasing current density and the phase structure of the alloys changed from $\eta-Zn$ through $\eta-Zn+\gamma'-ZnCr\;to\;\gamma'-ZnCr$ with Increasing Cr content of the alloys. The Co content in Zn-Cr-Co alloys increased with Co content of the bath, while Cr content of the alloy increased or decreased in low current density region $(10-75A/dm^2)$ or high current density region $(75-100A/dm^2)$, respectively. $\gamma-ZnCo$ phase was formed in the Zn-Cr-Co alloy with above $9.0wt\%$ Co. The content of Mn and Cr in Zn-Cr-Mn alloys increased or decreased with the increase of current density in high current density region, respectively while Cr content of the alloy decreased noticeably with the increase of Mn content in the bath. Two phases of $\delta_1-ZnMn$ and $\gamma'-ZnCr$ were formed in the Zn-Cr-Mn alloy with above $8.6wt\%$ Mn.