• Title/Summary/Keyword: Delta Arm

Search Result 25, Processing Time 0.025 seconds

Thermodynamic Studies on Complexes for Dibenzo-16-crown-5 Sulfur Lariat Ether with Metal Ions (Dibenzo-16-crown-5 Lariat Ether와 금속이온과의 착물형성에 관한 연구)

  • Cho, Moon Hwan;Lee, Sang Chul;Cho, Jae Hoon;Kim, Eung Tae;Rhee, Chang Hwan;Choi, Young Sup;Lee, Jong Chan
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.443-448
    • /
    • 1998
  • The thermodynamic parameters for the interaction of metal ions with dibenzo-16-crown-5 and its derivatives have been determined by solution calorimetry in methanol at 25$^{\circ}C$. Thermodynamic properties of log K, ${\Delta}H$, and $T{\Delta}S$ have been determined for the complexation of metal cations by dibenzo-16-crown-5 and its derivatives. Dibenzo-16-crown-5 and its derivatives have been studied as metal cations carrier in bulk liquid membrane (BLM) and supported liquid membrane (SLM) system. $Ag^+$ has been much more transported using dibenzo-16-crown-5 derivatives as carriers and several other metal cations have been small transported using carrier in BLM and SLM system. Ligand structure, the length of side arm, donor atom, stability constant, and carrier concentration are also important parameters in the transport of cations.

  • PDF

TRIGONOMETRIC DISTANCE AND PROPER MOTION OF IRAS 20056+3350: A MASSIVE STAR FORMING REGION ON THE SOLAR CIRCLE

  • BURNS, ROSS A.;NAGAYAMA, TAKUMI;HANDA, TOSHIHIRO;OMODAKA, TOSHIHIRO;NAKAGAWA, AKIHARU;NAKANISHI, HIROYUKI;HAYASHI, MASAHIKO;SHIZUGAM, MAKOTO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.121-123
    • /
    • 2015
  • We report our measurements of the trigonometric distance and proper motion of IRAS 20056+3350, obtained from the annual parallax of $H_2O$ masers. Our distance of $D=4.69^{+0.65}_{-0.51}kpc$, which is 2.8 times larger than the near kinematic distance adopted in the literature, places IRAS 20056+3350 at the leading tip of the Local arm and proximal to the Solar circle. We estimated the proper motion of IRAS 20056+3350 to be (${\mu}_{\alpha}cos{\delta}$, ${\mu}_{\delta}$) = ($-2.62{\pm}0.33$, $-5.65{\pm}0.52$) $mas\;yr^{-1}$ from the group motion of $H_2O$ masers, and use our results to estimate the angular velocity of Galactic rotation at the Galactocentric distance of the Sun, ${\Omega}_0=29.75{\pm}2.29km\;s^{-1}kpc^{-1}$, which is consistent with the values obtained for other tangent points and Solar circle objects.

Solidification Microstructures with Carbon Contents and Solidification Rates in Modified 12Cr-lMo Steels (개량 12Cr-1Mo강에서 탄소 함량 및 응고속도에 따른 응고 조직 형성 거동)

  • Eum C. Y;Lee J. H;Hur S. K;Chi B. H;Ryu S. H
    • Korean Journal of Materials Research
    • /
    • v.14 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • The influences of solidification rates and carbon contents on the formation of the $\delta$-ferrite were studied by directional solidification in modified 12%Cr-l %Mo steels. Directional solidification experimental results showed that solidification microstructure depended on solidification rate and carbon content and chromium equivalent. The length of the mushy zone increased and the dendrite arm spacings decreased as the solidification rate increased. The volume fraction of the 8-ferrite decreased with increasing the solidification rate and carbon content. The volume fraction of the ferrite showed much higher at low solidification rates with planar and cellular interfaces than that at high solidification rates with dendritic interface. It is expected that macro-segregation of C causes lower C content at the lower solidification fraction in the directionally solidified sample, where lower C results in higher volume fraction of the ferrite. In order to estimate solidification microstructure in modified 12Cr-l%Mo steels, various solidification conditions, such as solidification rate, cooling rate, segregation, alloy composition, should be considered.

Long-term clinical and radiographic outcomes of arthroscopic acromioclavicular stabilization for acute acromioclavicular joint dislocation

  • Eduard Van Eecke;Bernard Struelens;Stijn Muermans
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.2
    • /
    • pp.219-228
    • /
    • 2024
  • Background: Standard open acromioclavicular (AC) stabilization is associated with increased postoperative complications including deltoid injury, infection, tunnel complications, loss of reduction, and wound/cosmetic concerns. Arthroscopy may offer superior visualization and advantages that limit these risks. The aim of this prospective non-randomized study is to evaluate advantages and long-term reliability of arthroscopic AC stabilization. Methods: Thirty-two patients with acute grade III, IV and V AC dislocations underwent arthroscopic AC reconstruction with long-term assessment by clinical AC examination, Simple Shoulder Test, American Shoulder and Elbow Surgeons scores, visual analog scale, Specific AC Score and Quick Disabilities of the Arm, Shoulder and Hand scores. Radiographs verified conservation of initial reduction and presence of coracoclavicular (CC) ossifications. Complications, revision rate, and satisfaction were assessed and compared to the literature. Results: Mean follow-up time was 67.6 months. All clinical outcome scores improved and differences were statistically significant (P<0.001). Initial postoperative radiographs consistently showed complete reduction. Two patients experienced relapse to grade II AC dislocation without clinical implications. In total, 71.8% showed CC ossifications without functional impairment, and in 31.3% concomitant injuries were observed. Reintervention rate was 9.4%, and 96.9% of patients were satisfied with procedure outcomes. Conclusions: Arthroscopic stabilization for acute AC joint dislocations offers satisfactory clinical and radiographic outcomes, and our results show that the arthroscopic technique is reliable in the long run. We report better reduction in maintenance, fewer complications, and similar reoperation rates compared to other techniques.

Improvement in Computation of Δ V10 Flicker Severity Index Using Intelligent Methods

  • Moallem, Payman;Zargari, Abolfazl;Kiyoumarsi, Arash
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.228-236
    • /
    • 2011
  • The ${\Delta}\;V_{10}$ or 10-Hz flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ${\Delta}\;V_{10}$ index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition, in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover, it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.

Implementation of Inverter Systems for DC Power Regeneration

  • Kim Kyung-Won;Yoon In-Sic;Seo Young-Min;Hong Soon-Chan;Yoon Duck-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.126-131
    • /
    • 2001
  • This paper deals with implementation of inverter systems for DC power regeneration, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, a three-phase square-wave inverter system is adopted. To control the regenerated power, the magnitude and phase of fundamental output voltages should be appropriately controlled in spite of the variation of input DC voltage. Inverters are operated with modified a-conduction mode to fix the potential of each arm. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified $\alpha-conduction\;mode\;with\;\delta\;and\;\alpha$, a DPLL for frequency followup, and power circuit.

  • PDF

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.

Fabrication and Characterization of PLC-based Mach-Zehnder Interferometer Sensor (PLC-기반의 마흐-젠더 간섭계 센서 제작 및 특성 평가)

  • Kim, Jun-Hyong;Yang, Hoe-Yong;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.390-390
    • /
    • 2008
  • In this paper, we have designed and fabricated optical waveguides based on the Mach-Zehnder Interferometer (MZI) for application to sensor. The evanecent-wave sensor based on the MZI principle has sufficiently high sensitivity to measure the change of the refractive index on surface of a waveguide. The waveguides were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of MZI optical waveguides was performed by a conventional Planar Lightwave Circuit (PLC) fabrication process. The fabricated MZI optical waveguide device was measured. According to the measurement result, the insertion loss of MZI optical waveguide device was below 3.5 dB and the polarization dependent loss (PDL) was within 0.1dB. In addition, we analyzed optical properties of MZI sensor according to the refractive index change of the sensor arm.

  • PDF

Growth Charateristics of Methane-Propane Clathrate Hydrate (메탄-프로판 하이드레이트의 성장 특성에 관한 연구)

  • Lee, Ju-Dong;Lee, Man-Sig;Kim, Young-Seok;Song, Myung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.391-394
    • /
    • 2006
  • Growth characteristics of methane-propane clathrate hydrate, growing under different undercooling conditions, was investigated. After the water within pressurized vessel was fully saturated with guest gas molecules by agitation, medium was rapidly undercooled and maintained at the constant temperature. The growth of hydrate was always Initiated with film formations at the upper bounding surface of liquid pool. The visual observation using microscope revealed detailed features of subsequent crystal nucleation, migration, growth and interference occurring within liquid pool. A number of small crystals ascended and settled at the hydrate film. When undercooling was small $({\Delta}T=3.2K)$, some of the settled crystals slowly grew into faceted columns. As the undercooling increased, the downward growth of crystals underneath the hydrate film became dendritic and occurred with greater rate and with finer arm spacing. The shapes of the floating crystals were diverse and included octahedron and triangular or hexagonal platelet When the undercooling was small, the octahedral crystals were found dominant. As the undercooling increased, the shape of the floating crystals also became dendritic. The detailed characteristics of floating crystals were reported in this study.

  • PDF

Case Report of Hemiplegia after apoplexy in a Patient with Monoplegia on Right upper Extremity Treated with Herbal Prescription (우상지(右上肢) 단마비(單痲痺)가 주증(主症)인 풍비 환자의 만금탕가미방(萬金湯加味方) 투여 호전 1례)

  • Jeong, Byeong-Ju;Woo, Sung-Ho;Kim, Byung-Chul;Kim, Yong-Ho;Seo, Ho-Seok;Hwang, Gyu-Dong;Jang, Ha-Jeong;Nam, Hyo-Ick;Kim, Hoi-Young;Kim, Jin-Won
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.1
    • /
    • pp.288-293
    • /
    • 2006
  • Background : Monoplegia is the paralysis of a limb. It is commonly caused by an injury to the cerebral cortex, and rarely caused by injury to the internal capsule, brain stem, or spinal cord. Most problems with cerebral cortex is derived from the occlusion of a brain cortex blood vessel due to thrombus or embolus. Objectives : This study is to see if there is a significance in thermal differences of acupoints in diagnosis and treatment of monoplegia on an upper extremity to test the validity of acupuncture and herbal treatment for it. Methods : By using Digital Infrared Thermographic Imaging(DITI), thermal differences$({\Delta}T)$ of acupoints on the upper extremity in a patient with monoplegia on the right upper extremity were measured after an attack of the disease. By giving Mangeum-tang(萬金湯) and treating the patient with acupuncture. the temperature changes of the upper extremity were examined through DITI and improvement was observed. Results : Compared with the left arm which suffered no such injury, the right recovered about 80% of sensation, and the grade of monoplegia improved from Grade O to Grade V. Also, the temperatures of right palmar-dorsal hand and the region of Weiguan(外關, Waiguan, TE5) were $1^{\circ}C$ and $1.45^{\circ}C$ higher than the same left region on admission day, but the thermal differences$({\Delta}T)$ narrowed to $0.5^{\circ}C$ by the last day. Conclusions : Results suggest that DITI screening is a reliable method of prognosis and that the time required for treatment can be estimated through this method in cases of monoplegia to an upper extremity. Also, progress in treatment is reflected in thermal differences of acupoints of the monoplegic upper extremity in accordance with the theory of meridian. This supports a role for acupuncture and herbal treatment for monoplegia.

  • PDF