• Title/Summary/Keyword: Delivery Charge

Search Result 129, Processing Time 0.024 seconds

Interactions of Cationic Drugs and Cardiac Glycosides at the Hepatic Uptake Level: Studies in the Rat in Vivo, Isolated Perfused Rat Liver, Isolated Rat Hepatocytes and Oocytes Expressing oatp2

  • Dirk K.F.Meijer;Jessica E.van Montfoort
    • Archives of Pharmacal Research
    • /
    • v.25 no.4
    • /
    • pp.397-415
    • /
    • 2002
  • This paper deals with a crucial mechanism for interaction of basic drugs and cardiac glycosides at the hepatic uptake level. Available literature data is provided and new material is presented to picture the differential transport inhibition of bulky (type2) cationic drugs by a number of cardiac glycosides in rat liver. It is shown that the so called organic anion transporting peptide 2 (oatp2) is the likely interaction site: differential inhibition patterns as observed in oocytes expressing oatp2, could be clearly identified also in isolated rat hepatocytes, isolated perfused rat liver and the rat in vivo. The anticipation of transport interactions at the hepatic clearance level should be based on data on the relative affinities of interacting substrates for the transport systems involved along with knowledge on the pharmacokinetics of these agents as well as the chosen dose regimen in the studied species. This review highlights the importance of multispecific tranporter systems such as OATP, accommodating a broad spectrum of organic compounds of various charge, implying potential transport interactions that can affect body distribution and organ clearance.

Local Drug Delivery System Using Biodegradable Polymers

  • Khang, Gil-Son;Rhee, John M.;Jeong, Je-Kyo;Lee, Jeong-Sik;Kim, Moon-Suk;Cho, Sun-Hang;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • v.11 no.4
    • /
    • pp.207-223
    • /
    • 2003
  • For last five years, we are developing the novel local drug delivery devices using biodegradable polymers, especially polylactide (PLA) and poly(D,L-lactide-co-glycolide) (PLGA) due to its relatively good biocompatibility, easily controlled biodegradability, good processability and only FDA approved synthetic degradable polymers. The relationship between various kinds of drug [water soluble small molecule drugs: gentamicin sulfate (GS), fentanyl citrate (FC), BCNU, azidothymidine (AZT), pamidronate (ADP), $1,25(OH)_2$ vitamin $D_3$, water insoluble small molecule drugs: fentanyl, ipriflavone (IP) and nifedipine, and water soluble large peptide molecule drug: nerve growth factor (NGF), and Japanese encephalitis virus (JEV)], different types of geometrical devices [microspheres (MSs), microcapsule, nanoparticle, wafers, pellet, beads, multiple-layered beads, implants, fiber, scaffolds, and films], and pharmacological activity are proposed and discussed for the application of pharmaceutics and tissue engineering. Also, local drug delivery devices proposed in this work are introduced in view of preparation method, drug release behavior, biocompatibility, pharmacological effect, and animal studies. In conclusion, we can control the drug release profiles varying with the preparation, formulation and geometrical parameters. Moreover, any types of drug were successfully applicable to achieve linear sustained release from short period ($1{\sim}3$ days) to long period (over 2 months). It is very important to design a suitable formulation for the wanting period of bioactive molecules loaded in biodegradable polymers for the local delivery of drug. The drug release is affected by many factors such as hydrophilicity of drug, electric charge of drug, drug loading amount, polymer molecular weight, the monomer composition, the size of implants, the applied fabrication techniques, and so on. It is well known that the commercialization of new drug needs a lot of cost of money (average: over 10 million US dollar per one drug) and time (average: above 9 years) whereas the development of DDS and high effective generic drug might be need relatively low investment with a short time period. Also, one core technology of DDS can be applicable to many drugs for the market needs. From these reasons, the DDS research on potent generic drugs might be suitable for less risk and high return.

A Electron-Transfer Study on Self-Assembled Viologen Monolayer In different Electrolytes Using Electrochemical Process (전기화학법을 이용한 전해질 변화에 따른 Viologen 자기조립박막의 전하이동 특성 연구)

  • Lee, Dong-Yun;Park, Sang-Hyun;Shin, Hoon-Kyu;Park, Jae-Chul;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.878-881
    • /
    • 2004
  • When it converted solar energy or light energy into chemical energy, it studied the electric charge transfer property of the viologen which is used widely as the electron acceptor for the electric charge delivery mediation of the devices. It was formed monolayer in QCM by self-assembled viologen. The absorbed quantities of viologen's electron through peak current and to analyze the electron transfer property of viologen in redox reaction made experiments in cyclic voltammetry among the electrochemical process. It studied the electron transfer relation of viologen from changing the anion in 0.1M NaCl and $NaClO_4$ electrolyte and the interrelation between scan rate and peak current when scan rate increased twice.

  • PDF

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

Galactosylated Chitosan (GC)-graft-Poly(vinyl pyrrolidone) (PVP) as Hepatocyte-Targeting DNA Carrier: In Vitro Transfection

  • Park, In-Kyu;Jiang, Hu-Lin;Cook, Seung-Eun;Cho, Myung-Haing;Kim, Su-Il;Jeong, Hwan-Jeong;Akaike, Toshihiro;Cho , Chong-Su
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1284-1289
    • /
    • 2004
  • Galactosylated chitosan-graft-poly(vinyl pyrrolidone) (GCPVP) was synthesized and characterized for hepatocyte-targeting gene carrier. GCPVP itself as well as GCPVP/DNA complex had negligible cytotoxicity regardless of the concentration of GCPVP and the charge ratio, but GCPVP/DNA complex had slightly cytotoxic effect on HepG2 cells only in the case of the higher charge ratio and 20 mM of $Ca^{2+}$ concentration used. Through the confocal laser scanning microscopy, it is shown that the endocytosis by interaction between galactose ligands of GCPVP and ASGPR of the hepatocytes was the major route of transfection of GCPVP/F-plasmid complexes.

VEGF siRNA Delivery by a Cancer-Specific Cell-Penetrating Peptide

  • Lee, Young Woong;Hwang, Young Eun;Lee, Ju Young;Sohn, Jung-Hoon;Sung, Bong Hyun;Kim, Sun Chang
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.3
    • /
    • pp.367-374
    • /
    • 2018
  • RNA interference provides an effective tool for developing antitumor therapies. Cell-penetrating peptides (CPPs) are delivery vectors widely used to efficiently transport small-interfering RNA (siRNA) to intracellular targets. In this study, we investigated the efficacy of the cancer-specific CPP carrier BR2 to specifically transport siRNA to cancer-target cells. Our results showed that BR2 formed a complex with anti-vascular endothelial growth factor siRNA (siVEGF) that exhibited the appropriate size and surface charge for in vivo treatment. Additionally, the BR2-VEGF siRNA complex exhibited significant serum stability and high levels of gene-silencing effects in vitro. Moreover, the transfection efficiency of the complex into a cancer cell line was higher than that observed in non-cancer cell lines, resulting in downregulated intracellular VEGF levels in HeLa cells and comprehensively improved antitumor efficacy in the absence of significant toxicity. These results indicated that BR2 has significant potential for the safe, efficient, and specific delivery of siRNA for diverse applications.

Development of Polymeric Nanopaclitaxel and Comparison with Free Paclitaxel for Effects on Cell Proliferation of MCF-7 and B16F0 Carcinoma Cells

  • Yadav, Deepak;Anwar, Mohammad Faiyaz;Garg, Veena;Kardam, Hemant;Beg, Mohd Nadeem;Suri, Suruchi;Gaur, Sikha;Asif, Mohd
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2335-2340
    • /
    • 2014
  • Paclitaxel is hydrophobic in nature and is recognized as a highly toxic anticancer drug, showing adverse effects in normal body sites. In this study, we developed a polymeric nano drug carrier for safe delivery of the paclitaxel to the cancer that releases the drug in a sustained manner and reduces side effects. N-isopropylacrylamide/vinyl pyrrolidone (NIPAAm/VP) nanoparticles were synthesized by radical polymerization. Physicochemical characterization of the polymeric nanoparticles was conducted using dynamic light scattering, transmission electron microscopy, scanning electron microscopy and nuclear magnetic resonance, which confirmedpolymerization of formulated nanoparticles. Drug release was assessed using a spectrophotometer and cell viability assays were carried out on the MCF-7 breast cancer and B16F0 skin cancer cell lines. NIPAAm/VP nanoparticles demonstrated a size distribution in the 65-108 nm range and surface charge measured -15.4 mV. SEM showed the nanoparticles to be spherical in shape with a slow drug release of ~70% in PBS at $38^{\circ}C$ over 96 h. Drug loaded nanoparticles were associated with increased viability of MCF-7 and B16F0 cells in comparison to free paclitaxel. Nano loaded paclitaxel shows high therapeutic efficiency by sustained release action for the longer period of time, i increasing its efficacy and biocompatibility for human cancer therapy. Therefore, paclitaxel loaded (NIPAAm/VP) nanoparticles may provide opportunities to expand delivery of the drug for clinical selection.

Measurement of Delivery Service Environment for Cold Chain EPS Packaging System of Fresh Food (신선식품 콜드체인 EPS 패키징 시스템의 택배 유통환경 계측)

  • KORAKOT, CHAROENSRI;Kim, SY;Shin, YJ;Jung, HM;Park, JM
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • The food cold chain refers to a technology and distribution supply chain applied to maintain a constant temperature suitable for the product from production (harvest) to delivery to consumers. In particular, in Korea, the insulation material used in the food cold chain is mostly EPS (Expanded Polystyrene), which is used as a transport container for various food cold chains. However, according to the government's eco-friendly policy, companies charge environmental contributions to the use of EPS, but due to its low price and convenience of handling, it is still used as a container for delivering food. In this study, in order to measure the domestic delivery environment of general refrigerated foods, changes in impact, temperature, and humidity during transport of the EPS packaging system containing foods and ice pack refrigerants were measured. As a result, there were 2?3 sections in which a high impact force of 40 G or more was generated during transport. This can cause damage to the product and EPS container. The difference in temperature and humidity changes by parcel transport routes is more than 30%, so it is necessary to present accurate standards for the domestic cold chain distribution environment. As a result of microbial experiments. the transportation period had a dominant effect on the increase in total viable count and E. coli count.

Changes in Hospital and Clinic Care Patterns Under the Medical Insurance System (의료보험 실시후 2년간의 진료양상의 변화 -서울시내 의료기관 입원환자를 중심으로-)

  • Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.14 no.1
    • /
    • pp.3-12
    • /
    • 1981
  • To identify the changes in professional care patterns after the introduction of medical insurance in Korea, professional care in hospitals and clinics of two succeeding years were compared. The hospitals and clinics selected for this study were those which located in Seoul city. Hospitals were classified into 3 categories: university hospital, general hospital and hospital. The diseases selected for this study were acute appendicitis and normal delivery. They were selected because their disease courses are considered to be fairly stable. The variables used for this study were length of stay, total hospital costs, costs of each components of cares. The information used for this study was obtained from the official forms requested by the medical facilities to the Korea Medical Insurance Corporation. The two periods studied were 3 months of each year from March 1st to May 31st in 1979 and 1980, The total number of normal delivery studied was 289 in 1979, 301 in 1980 respectively and the acute appendicitis was 92 and 111 respectively. In order to compare the quantity of medical care between 2 study periods the insurance price scores of 1979 were converted to prices of 1980. For statistical test of difference between 2 periods T-test and Welch's test were used. The result of the study were briefly summarized in below. 1. No significant difference was observed in the average length of stay of both disease between two study periods in all types of hospitals. 2. No significant difference was observed in the average total hospital costs of both diseases in all types of hospital, but in the private clinic the average clinic costs was rather decreased significantly in 1980. 3. More cost decrease were seen than cost increase in 1980 in all types of facilities, More cost changes by items were seen in acute appendicitis than in normal delivery between two study periods. The total hospital costs can be devided into 2 portions: charges for drug and material and for physician. In normal delivery, costs for physician's charges was significantly decreased in almost all the hospitals and costs for drug and material were not changed significantly in all the hospitals in 1980. In the university hospitals, however, the costs for drug and material were increased significantly in 1980. The cost decrease for physician's charge were mainly due to the decrease in the costs of laboratory test, treatment and physical therapy. The increase in the costs for the drug and material in the university hospitals was mainly due to the increase in the cost for drugs for oral administration and injection. 4. The proportion of components of medical care in the hospital has not been changed significantly, however, the cost for injection in normal delivery was characteristically increased in 1980 in all hospitals studied. In general the proportion of the costs for drug and material was tended to increase and the costs for physician was tended to decrease in 1980. The increase in the costs for drug and material were considered to be due to increase in the cost for drugs for oral administration and injection. The decrease in the costs for physician were due to decrease in the costs of laboratory test, treatment and physical therapy. Above mentioned changes in hospital and clinic care patterns are considered to be mostly influenced by the review criteria set by the K.I.C. for the assessment of the fee request made by clinics and hospitals.

  • PDF

A Study on the Reconstruction of Multi-Echelon Distribution System by the Customer Demand Decomposition of Regional Distribution Center (지역분배센터의 고객수요분할을 통한 다단계 분배체계 재구축에 관한 연구)

  • 최진영
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.61-68
    • /
    • 1997
  • The algorithm of customer demand decomposition suggested by this study is a reconstruction method of distribution network under the allowance of same level supply. Regional distribution center(RDC) distributes additional inventories of some of the supplying items to retailers under its charge to reduce the time needed for emergency delivery to neighborhood retailer where backlog happened. This also restrict the purpose of the inventories held by RDC as only regular supply. All of which leads to the creation of more realistic method allowing the affiliation of closing related RDC with one in the vicinity. In this study, the role of RDC is restricted only as supplying items regularity and the conruction of distribution system processing through the closing by consideration of the possibility of supplying retailers from the RDC in the vicinity is discussed.

  • PDF