• Title/Summary/Keyword: Delayed Compensation

Search Result 56, Processing Time 0.021 seconds

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

Compensation of Time Delay in Induction Motor Vector Control System Using DQ Transformation (유도전동기 벡터제어 시스템에서 DQ변환을 이용한 시간지연 보상)

  • 최병태;권우현;박철우
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1001-1008
    • /
    • 2003
  • A time-delay compensation method for vector control system is proposed that can compensate for voltage and current distortions resulting from a time delay in the overall system due to the low pass filter, hysteresis control inverter, microprocessor program computation time, and so on. The proposed scheme estimates the time delay using the difference between the Q-axis stator current command and the time-delayed actual Q-axis stator current in a synchronous reference frame, then compensates the time delay in the voltage and current using the angular displacement of a DQ transformation. Accordingly, the proposed scheme can accurately compensate for the time delay related to the overall system, thereby significantly improving the performance of the vector control system, as verified by simulation and experiment.

A New Control Method of Series Single-Phase Hybrid Active Power Filter (직렬형 단상 하이브리드 능동 전력필터의 새로운 제어법)

  • Kim, Jin-Sun;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.149-151
    • /
    • 2005
  • This paper deals with the novel control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active power filters. To construct two-axes coordinate, an imaginary second phase was made by giving time delay to line current. In this proposed method, the new signal, which was the delayed through the filtering by the phase-delay property of low-pass filter, is used as the secondary phase. Because two phases have different phase, instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying gain of filter by compensation current using the rotating reference frames that synchronizes with source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames. This paper shows the experimental results, which provide a high accuracy and extremely fast response of single-phase hybrid active Bower filter under the operation with the proposed control method.

  • PDF

Single-Phase Hybrid Active Power Filter Using Rotating Reference Frame (회전좌표계를 이용한 단상 하이브리드형 능동 전력필터)

  • Kim Jin-Sun;Kim Young-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.8
    • /
    • pp.377-386
    • /
    • 2005
  • This paper presents the control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active Power filters. To construct two phase system, an imaginary second phase was made. In this proposed method, the new signal which is the delayed through the filtering by the phase-delay property of low-pass filter is used as the secondary phase. Because two-phases have the different phase, the instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames In order to verify the validities of the proposed control methods, experiments are carried out with the prototypes of single-phase hybrid active power filter.

Association Between Initiation of Rehabilitation and Length of Hospital Stay for Workers with Moderate to Severe Work-Related Traumatic Brain Injury

  • Suk Won Bae;Min-Yong Lee
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.229-236
    • /
    • 2023
  • Background: In workers with moderate to severe work-related traumatic brain injury (wrTBI), this study aimed to investigate the effect of the timing of rehabilitation therapy initiation on the length of hospital stay and the factors that can influence this timing. Methods: We used data obtained from the Republic of Korea's nationwide Workers' Compensation Insurance. In the Republic of Korea, between the years 2010 and 2019, a total of 26,324 workers filed a claim for compensation for moderate to severe wrTBI. Multiple regression modeling was performed to compare the length of hospital stay according to the timing of rehabilitation therapy initiation following wrTBI. According to the timing of the initiation of rehabilitation therapy following TBI, the proportions of healthcare institutions that provided medical care during each admission step were compared. Results: The length of hospital stay for workers who started rehabilitation therapy within 90 days was significantly shorter than that for workers who started rehabilitationment were first admitted to tertiary hospitals. Approximately 39% of patients who received delayed rehabilitation treatment were first admitted to general hospitals, and 28.5% were first admitted to primary hospitals. Conclusions: Our findings demonstrate the importance of early rehabilitation initiation and that the type of healthcare institution that the patient is first admitted to after wrTBI may influence the timing of rehabilitation initiation. The results of this study also emphasize the need to establish a Worker's Compensation Insuranceespecialized rehabilitation healthcare delivery system.

Design of the analog phase shifter for the ghost signal elimination (고스트 신호 제거기용 애널러그 위상변위기 설계)

  • 주성호;김동현;이상설
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.825-828
    • /
    • 1999
  • In this paper, we design the analog phase shifter for the elimination of the ghost signal. Compensation of the delay between the reference signal and the relatively delayed signal is possible. This phase shifter uses the vector summing method. We use for the attenuator in our system FETs. The phase shifter is operated at the 200MHz and composed by lumped elements. The proposed analog phase shifter is simulated by the HP ADS software.

  • PDF

Delay-Dependent Control for Time-Delayed T-S Fuzzy Systems Using Descriptor Representation

  • Jeung, Eun-Tae;Oh, Do-Chang;Park, Hong-Bae
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.182-188
    • /
    • 2004
  • This paper presents a design method of delay-dependent control for T-S fuzzy systems with time delays. Based on parallel distributed compensation (PDC) and a descriptor model transformation of the system, a delay-dependent control is utilized. An appropriate Lyapunov-Krasovskii functional is chosen for delay-dependent stability analysis. A sufficient condition for delay-dependent control is represented in terms of linear matrix inequalities (LMIs).

Fuzzy H2/H Controller Design for Delayed Nonlinear Systems with Saturating Input (포화입력을 가지는 시간지연 비선형 시스템의 퍼지 H2/H 제어기 설계)

  • Cho, Hee-Soo;Lee, Kap-Rai;Park, Hong-Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.3
    • /
    • pp.239-245
    • /
    • 2002
  • In this Paper, we present a method for designing fuzzy $H_2/H_{\infty}$ controllers of delayed nonlinear systems with saturating input. Takagi-Sugeno fuzzy model is employed to represent delayed nonlinear systems with saturating input. The fuzzy control systems utilize the concept of the so-called parallel distributed compensation(PDC). Using a single quadratic Lyapunov function, the globally exponential stability and $H_2/H_{\infty}$ performance problem are discussed. And a sufficient condition for the existence of fuzzy $H_2/H_{\infty}$ controllers is given in terms of linear matrix inequalities(LMIs). The designing fuzzy $H_2/H_{\infty}$ controllers minimize an upper bound on a linear quadratic performance measure. Finally, a design example of fuzzy $H_2/H_{\infty}$ controller for uncertain delayed nonlinear systems with saturating input.

The Design of Robust DSC-PLL under Distorted Grid Voltage Contained Unbalance on Frequency Variation (주파수 변동시 불평형 전압에 강인한 DSC-PLL 설계 연구)

  • Lee, Jae Do;Cha, Han Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1447-1454
    • /
    • 2018
  • In this paper, the design of robust DSC-PLL(Delayed Signal Cancellation Phase Locked Loop) is proposed for coping with frequency variation. This method shows significant performance for detection of fundamental positive sequence component voltage when the grid voltage is polluted by grid unbalance and frequency variation. The feedback frequency estimation of DSC-PLL is tracking the drift in the phase by unbalance and frequency variation. The robust DSC PLL is to present the analysis on method and performance under frequency variations. These compensation algorithms can correct for discrepancies of changing the frequency within maximum 193[ms] and improve traditional DSC-PLL. Linear interpolation method is adopted to reduce the discretized errors in the digital implementation of the PLL. For verification of robust characteristic, PLL methods are implemented on FPGA with a discrete fixed point based. The proposed method is validated by both Matlab/Simulink and experimental results based on FPGA(XC7Z030).

A Method for Estimating an Instantaneous Phasor Based on a Modified Notch Filter

  • Nam Soon-Ryul;Sohn Jin-Man;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • A method for estimating the instantaneous phasor of a fault current signal is proposed for high-speed distance protection that is immune to a DC-offset. The method uses a modified notch filter in order to eliminate the power frequency component from the fault current signal. Since the output of the modified notch filter is the delayed DC-offset, delay compensation results in the same waveform as the original DC-offset. Subtracting the obtained DC-offset from the fault current signal yields a sinusoidal waveform, which becomes the real part of the instantaneous phasor. The imaginary part of the instantaneous phasor is based on the first difference of the fault current signal. Since a DC-offset also appears in the first difference, the DC-offset is removed trom the first difference using the results of the delay compensation. The performance of the proposed method was evaluated for a-phase to ground faults on a 345kV 100km overhead transmission line. The Electromagnetic Transient Program was utilized to generate fault current signals for different fault locations and fault inception angles. The performance evaluation showed that the proposed method can estimate the instantaneous phasor of a fault current signal with high speed and high accuracy.