• 제목/요약/키워드: Dehumidification device

검색결과 12건 처리시간 0.024초

열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구 (A Fundamental Study on the Composition for the Hybrid Dehumidification System Using Thermoelectric Device)

  • 류성룡;염호진;이현제;조현
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.618-626
    • /
    • 2018
  • In this paper, the hybrid dehumidification system using thermoelectric device is based on the idea of utilizing waste heat from the heat dissipation side of thermoelectric device as a heat source to regenerate chemical desiccant. We would like to apply this system to spaces required dehumidification due to continuous moisture generation or local high humidity in the houses. And, we want to confirm the possibility of developing the hybrid dehumidification system that combines passive dehumidification using chemical desiccant with active dehumidification using thermoelectric device.

분리막 제습공조시스템의 잠열부하 저감효과 예측 (Prediction of Latent Heat Load Reduction Effect of the Dehumidifying Air-Conditioning System with Membrane)

  • 정용호;박성룡
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.15-20
    • /
    • 2017
  • The summer climate is very hot and humid in Korea. The humidity is an important factor in determining thermal comfort. Recently, the research for dehumidification device development has been attempted to save energy that is required for the operation of the current dehumidifiers on the market. Existing dehumidification systems have disadvantages such as wasting energy to drive a compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature so it doesn't have to consume cooling energy. In this paper, the cooling energy savings was studied when a dehumidification system was applied in a model building instead of a chiller. The sensible heat load was almost the same result, but the latent heat load was decreased by 38.9% and the total heat load was decreased by 8.5%. As a result, electric energy used to drive the compressor in a chiller was saved by applying a membrane air-conditioning system instead.

분리막 제습공조시스템의 내부 유동 해석에 관한 연구 (A Study on Air Flow Analysis for the Internal Space of the Dehumidifying Air-Conditioning System with A Membrane)

  • 정용호;박성룡
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.620-625
    • /
    • 2015
  • The summer climate is very hot and humid in Korea. Humidity is an important factor in determining thermal comfort. Recently, research on dehumidification device development has been attempted to save the energy required for operating the dehumidifier. Existing dehumidification systems have disadvantages such as wasting energy to drive the compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature. Therefore. they don't have to consume cooling energy. In this paper, the installation conditions for a membrane system were analyzed to improve the shape and optimum performance of the system. The results showed that the distance between elements was the critical system design factor, and that a distance of 20 mm was the optimal condition for the pressure drop and flow characteristics of the internal air flow.

열전소자를 이용한 가정용 의류 건조기의 성능에 관한 실험적 연구 (A Study on the Performance of Home Clothes Dryer using Thermoelectric Module)

  • 이민재;공상운;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2073-2078
    • /
    • 2007
  • This study was performed to develop a dryer for home clothes using thermoelectric module. The thermoelectric module was used as a heat source and a dehumidification device because it has heating part and cooling part at once. To design for maximizing the energy efficiency and the rate of dehumidification, the parameters of the dryer using thermoelectric module are heat capacity and air flow rate. This study showed that the thermoelectric module can be used in the clothes dryer and energy efficiency of clothes dryer be better than that of electric heating dryer.

  • PDF

화물선의 결로 방지에 대한 연구 (A Study on the Condensation Prevention of Bulk Carrier)

  • 오세진;김원욱;김성환;이성근;김종수
    • 해양환경안전학회지
    • /
    • 제17권4호
    • /
    • pp.429-434
    • /
    • 2011
  • 선박에 적재된 곡류, 철강재 등의 산적화물에 여러 가지 이유로 손상이 발생될 수 있다. 본 논문에서는 코일 운반선의 화물손상 원인 중 특히, 결로에 의한 손상과 그에 대한 방지대책에 대해 분석하고자 한다. 결로란 주위 온도가 이슬점 이하로 떨어져 물체 표면에 공기 중의 수증기가 물방울로 맺히는 현상을 말하며 일반적으로 실내외 온도차가 큰 건축물이나 선박의 화물창에서 많이 발생한다. 특히, 비슷한 시기에 기온차가 있는 전 세계를 운항하는 선박에서 흔히 발생할 수 있는 현상이다. 본 연구에서는 코일 운반선의 결로에 의한 화물손상 방지 대책에 대해 고찰하고 화물손상을 방지하기 위해 제습장치와 가열온풍장치를 병용하는 새로운 방법의 제안과 습도, 습기량, 제습장치 용량, 결로수량, 화물 및 공기와 외기의 온도 차이에 따른 화물창 내 공기와 화물 가열에 필요한 열량, 가열장치 용량 등의 산정법을 제시한다.

공동주택에서 바닥복사냉방의 적정 운영방안에 관한 연구 (A Study on the Operation Strategy of Radiant Floor Cooling in Apartment Buildings)

  • 조영흠;석호태;여명석;김광우
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.574-583
    • /
    • 2004
  • In this study, the operation strategy of the radiant floor cooling is evaluated in terms of indoor environmental conditions and energy consumption through simulations using the TRNSYS comparing the existing cooling operation. The operation strategy during continuously operated for cooling is proposed that a representative room had additional equipments and other rooms were operated with only a radiant floor cooling system and that system and control method for cooling are varied with period while intermittently operated for cooling. Specifically, when there are no people in the room, rooms were operated by only radiant floor cooling system using cooling storage and when people are occupied, rooms were operated by dehumidification and supplementary cooling device with radiant floor cooling system. The results of this study show that proposed operation strategy can stably maintain the set room air temperature and can reduce the energy consumption compared to the existing cooling method during continuously operated for cooling. While intermittently operated for cooling, the difference of set room air temperature by proposed operation strategy does not happen, satisfying comfort standards and the radiant floor cooling can expect to supply stable electric power because of decreasing demand for peak electric power of energy consumption.

고품질화 바이오가스 이용 기술지침 마련을 위한 연구(III): 도시가스 및 수송용 - 기술지침(안) 중심으로 (A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Design and Operation Guideline)

  • 문희성;권준화;박호연;전태완;신선경;이동진
    • 유기물자원화
    • /
    • 제27권2호
    • /
    • pp.67-73
    • /
    • 2019
  • 본 연구에서는 유기성폐자원의 바이오가스 생산 및 이용을 최적화를 위해 현장시설의 정밀모니터링과 시설별 에너지수지를 분석하고, 현장문제 해결방안에 대해서 조사하여 전처리시설 및 발전기 등의 설계 및 운전 가이드라인을 제시하였다. 고품질화 정제설비 운영에 잦은 고장 및 효율 저하를 해결하기 위해서는 가스전처리가 필요하며, 탈황, 제습, 탈실록산, 분진 처리, 휘발성유기화합물 등의 처리공정이 있다. 이 공정들은 고품질화 공정에서도 제거되는 물질들이기에 가스 전처리에서는 정량적 가이드라인은 제시하지 않고, 정성적 가이드라인으로 처리공간에 운영하도록 제시하였다. 특히, 분진, 실록산 및 휘발성유기화합물 등은 가스 전처리에서 제거되지 않으면 고품질화 공정의 잦은 고장의 주원인이된다. 바이오가스 고품질화 공정에 대한 설계 운전 가이드라인은 전체 가스 발생량의 90 % 이상 이용, 2계열화, 여유율 10 % 이상 감안 등이 있으며, 품질기준[메탄함량(프로판 포함) 95 % 이상]을 제시함. 또한 균등한 바이오가스 유입을 위해 가스균등조 설치, 보조연료 균등투입 제어를 위한 열량자동조절장치 설치, 가스압축과정에서 다량 발생하는 수분 제거를 위한 고품질화 후단의 제습장치 설치, 겨울철 설비의 결빙 및 효율 저하 방지를 위한 보온설비 설치, 특히 멤브레인 설비는 실내 설치 등을 제시하였다.

싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구 (Process gas purification using cyclone recirculation and cooling process)

  • 김주회;조우진;최영태;조영민;김상범
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.25-33
    • /
    • 2018
  • 화석 연료의 고갈과 온난화 현상으로 인해 새로운 에너지원에 대한 관심이 급증하고 있다. 그 중에서 바이오가스는 유기성 폐기물 및 바이오매스를 혐기성 소화과정인 가수분해(hydrolysis), 산발효(acidogenesis), 유기산발효(acetogenesis), 메탄발효(methanogenesis)의 단계를 거쳐 발생되기 때문에 친환경적인 에너지자원으로 각광받고 있다. 그러나 바이오가스는 기존의 정제설비로는 제거할 수 없는 높은 미세분진 및 수분 함량으로 인해, 직접연소, 도시가스, 자동차용 연료 등 효율적인 이용을 위해서 정제시스템이 필요하다. 따라서 본 연구는 미세분진과 수분을 동시에 제거할 수 있는 정제과정의 전처리 방법으로써 원심력을 이용하는 냉각공정을 설계하였다. 원심력을 이용하여 분진을 제거하는 Cyclone 내 외부에 열교환기와 ID fan을 구성하여 주입되는 가스를 어는점 이하로 냉각시킴으로써 물안개를 형성시켜 분진입자를 제거하고, 일부 가스를 ID fan을 이용하여 재순환시켜 제거하는 고효율 냉각제어공정을 개발하였다. 수분제거는 유량(25~150L/min) 및 상대습도(60~95%)의 조건에서 시험하였다. 수분제거율은 상대습도 $95{\pm}5%$일 때 평균 80.8%, 입자제거율은 입자크기 $2.5{\mu}m$에서 평균 99.78%의 제거효율을 보였고, 수분과 입자의 동시제거효율은 수분 70.86%, 입자 99.67%의 평균값을 보여주었다.

에너지 절감형 항온항습기 운전 특성에 관한 연구 (Study on the energy-saving constant temperature and humidity machine operating characteristics)

  • 차인수;하민호;정경환
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.27-33
    • /
    • 2016
  • 본 연구에서 적용한 열회복 방식은 적은 동력사용으로 최대의 냉각능력을 낼 수 있는 에너지 절약형이다. 항온항습기의 온습도를 보다 정밀 한 제어 기능을 갖도록 하기 위해 제어 알고리즘은 퍼지 PID 제어기를 설계하여 적용하였고, 외기보상장치(공냉식)를 갖추어 동절기에 $-20^{\circ}C$에서도 우수한 제습능력을 발휘하게 하였다. 고효율, 저소음형 시로코 팬을 채용하여 정숙운전이 되며 장비특성에 따라 상향식과 하향식에 맞도록 설계하였다. 실험한 결과 변환 효율은 95%이상, 정전복귀는 5sec 이내, 정지지연은 30sec 이내, 펌프다운은 10sec, 펌프지연은 5sec, 히팅지연은 5sec, 온도편차는 ${\pm}2^{\circ}C$(냉방편차: $2^{\circ}C$, 난방 편차: $2^{\circ}C$), 습도편차는 ${\pm}5%$(가습편차 3.0%, 제습편차 3.0%)을 갖게 하였다. 최근 유비쿼터스 기술이 중요시 되고 있기에 핸드폰을 통해 항온항습기를 원격 제어 할 수 있도록 하였고, MMI 소프트웨어와 자동 인터페이스를 지원하여 확장성이 뛰어나게 하였다. 또한 지능형 컨트롤러 고장진단에 의한 부품 및 장비의 수명이 연장 되도록 하였다.