• 제목/요약/키워드: Degree of penetration

검색결과 261건 처리시간 0.023초

수종 상아질 접착제의 제 V급 와동에서의 미세 변연누출에 관한 비교연구 (AN EXPERIMENTAL STUDY FOR THE EFFECT OF ALL-BOND 2, GLUMA, SCOTCH BOND MULTI-PURPOSE)

  • 강창성;박성호;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.261-274
    • /
    • 1995
  • This study aimed to evaluate the marginal microleakage of Class V cavities of All-bond 2 (Wet - bonding system), Gluma (Adhesion of resin to exposed collagen fibers), and Scotchbond Multi-purpose(Mild Etching System). Hundred extracted human teeth divided into a control and three experimental groups consisting of eight teeth. The experimental group was further subdivided into All- bond2, Gluma and Scotchbond MP groups, Vitrebond served as the control. The positive control group consisted of specimens filled with resin and with no etching, primer and bonding procesure. Polished specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ a thousand times. After thermocycling, speciemens were placed in 2 % methylene blue dye solution for 24 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a stereomicroscoped(*20). The following results were obtained. 1. Both the control and the experimental group showed a lower degree of dye penetration on enamel than on dentin margins(p<0.05) 2. Gluma exhibited a statistically significant lower degree of dye penetration than All-bond 2 on enamel margins(p<0.05) Scotchbond MP also exhibited a lower degree of dye penetration than All-bone 2 but was no statistically significant. Gluma and Scotchbond MP exhibited a similar degree of dye penetration. 3. The degree of dye penetration of All-bond 2, Gluma and Scotch bond MP showed no statistically singnificance on enamel margins but was significantly lower than in the control using Vitrebond. 4. All-bond 2 exhibited a statistically significant lower degree of dye penetration than Gluma on dentin margins. All- bond 2 and Scotchbond MP showed a similar degree of dye penetration. 5. The degree of dye penetration of All-bond 2, Gluma and Scotchbond MP showed no statistically significance on dentin margins. There was neither a statistical significance with the control.

  • PDF

수종근관충전재의 변연누출에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF SEVERAL CANAL FILLING MATERIALS)

  • 윤수한
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.155-159
    • /
    • 1982
  • The author has studied comparatively the sealing quality of conventional Z.O.E. cement, chloropercha and FR cement by means of penetration of 2% methylene blue solution through the apex of human teeth in 112 cases as the time elapsed. The results were as follows; 1. All the specimen, of which dye immersion time is three days, showed dye penetration of low degree unrelated to the kinds of root canal cement and the degree of dye penetration was increased as the time elapsed. 2. Of all the experimental group, the Z.O.E. cement group showed the lowest degree of dye penetration and the FR filling group showed the highest degree of dye penetration. 3. The degree of dye penetration of FR cement group was higher than that of the Z.O.E. cement group but lower than that of the chloropercha group.

  • PDF

암반기계굴착공법의 적용연구 (Application of TBM/TBE to Mechanical Excavation in Rock)

  • 박철환;김길수
    • 터널과지하공간
    • /
    • 제2권1호
    • /
    • pp.177-189
    • /
    • 1992
  • As tunnel becomes longer and larger, TBM has become one of the most popular methods of excavatio in rock. This paper describes the degree of operation the degree of availability and penetration rate of TBM and TBE applied in Namsan roadway tunnelling site. Net penetration rate was 1.62m/hr for TBM and 0.72m/hr for TBE. Net penetration rate showed no direct relation to daily advance or penetration time, but the lower bound of penetration rate could be obtained from the relation with daily advance. For both of TBM and TBE, the degree of operation and the degree of availability were 33.8% and 68.6% respectively. Life time of normal cutter was $310m^3$ for TBM and $194m^3$ for TBE, while that of center and gauge cutter was about $50m^3$. When the two machines were compared, TBM showed 80% higher penetration rate, and 40% shorter life time of cutter.

  • PDF

A STUDY ON THE RELATIONSHIP BETWEEN IMPORT PENETRATION, BUSINESS DIVERSIFICATION AND FIRM PERFORMANCE

  • Kim, Seog-Soo;Kim, Dong-Jin;Park, Bong-Seon
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1951-1966
    • /
    • 2007
  • This research attempts to examine the effects of import penetration in an industry on the firms' decision of business diversification and provide an integrative framework including the determinants and results of the business diversification. The research results are as follows. First, the import penetration doesn't affect the degree of business diversification. Second, the more profitable their core business industry, the lower the degree of business diversification against the import penetration. In addition, both technology-related assets and marketing-related assets are necessary for business diversification when faced with the import penetration. Finally, the inverted U-shaped relationship is supported between the degree of business diversification and firm performance.

  • PDF

McSpadden Technique의 근관폐쇄효과에 대한 실험적 연구 (A STUDY ON THE SEALING ABILITY OF McSpadden TECHNIQUE)

  • 이상탁;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.127-134
    • /
    • 1984
  • This study was conducted to evaluate the sealing ability of McSpadden technique compared with lateral condensation and Engine reamer technique, and according to the degree of canal enlargement and the use and nonuse of sealer. Seventy single-rooted teeth were divided into 14 groups and each tooth was enlarged and obturated according to the purpose of this study. Obturated teeth were infiltrated by Indian ink and decalcified and cleared. The apical sealing ability was evaluated by measuring the degree of ink penetration into the canal. The results were as follows: 1. All the teeth filled by lateral condensation using gutta-percha cone and sealer proved better in canal sealing ability than McSpadden technique and Engine reamer technique, showing less ink penetration. 2. In the McSpadden technique, there was less ink penetration detected in using the sealer than not. 3. In all of the experimental methods, the difference of the degree of ink penetration according the degree of canal enlargement could not be accepted. 4. There was no significant difference in ink penetration degree between Engine reamer technique using sealer and McSpadden technique without sealer.

  • PDF

Kerr sealer를 근관충전재(根管充塡材)로 사용시(使用時) 근관폐쇄성(根管閉鏁性)에 관(關)한 실험적(實驗的) 연구(硏究) (EXPERIMENTAL STUDY on SEALING QUALITY OF KERR SEALER AS ROOT CANAL SEALERS)

  • 윤수한
    • Restorative Dentistry and Endodontics
    • /
    • 제6권1호
    • /
    • pp.77-81
    • /
    • 1980
  • The author has studied comparatively the sealing quality of conventional Z.O.E. cement, Kerr sealer and Nogenol sealer by means of penetration of 2% methylene blue solution through the root apex of human teeth in 72 cases as time elapsed. The results were as follows; 1. All the specimens, whose dye immersion time is two days, showed dye penetration of low degree unrelated to the kinds of root canal sealer. 2. Kerr sealer group, like conventional Z.O.E. group, showed dye penetration of high degree related to increased time of immersion in the dye. 3. In Nogenol group, there was slight increase in penetration related to increased time of immersion in the dye. 4. Kerr sealer group showed comparatively lower grade of dye penetration than conventional Z.O.E. and higher than Nogenel sealer.

  • PDF

유구치 아말감 수복물에서 레진 접착성 이장재의 미세 변연 누출에 관한 비교 연구 (AN EXPERIMENTAL STUDY FOR MICROLEAKAGE OF AMALGAM USING RESIN ADHESIVE LINERS IN PRIMARY MOLAR TOOTH)

  • 김종태;최병재;이제호;이종갑
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.401-414
    • /
    • 1996
  • The purpose of this study was to compare the marginal leakage of resin liner which was used as a liner to amalgam restoration. Control group composed of no liner group, copalite group and experimental group composed of All-bond 2, Vitrebond, Superbond D-liner applied groups were evaluated. Cl.V preparation with a size of $3{\times}2{\times}1.5mm$ on 70 extracted primary molars were made and applied appropriate liners for each groups. After amalgam filling and polishing, polished specimens underwent temperature changed from $5^{\circ}C\;to\;55^{\circ}C$ a thousand times. After thermocycling, specimens were placed in 2% methylene blue dye solution for 72 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a spectroscopy. (${\times}30$) The following results were obtained. 1. Vitrebond, All-bond 2, Superbond D-liner group exhibited a statistically significant lower degree of dye penetration than no liner and copalite group. (Kruskal-Wallis analysis, P<0.05) 2. No liner group and copalite group exhibited a similar degree of dye penetration. (Mann-Whitney analysis, P>0.05) 3. All-bond 2 group exhibited a statistically significant lower degree of dye penetration than Vitrebond group, (Mann-Whitney analysis, P<0.05) Superbond D-liner group also exhibited a lower degree of dye penetration than Vitrebond group but was statistically insignificant. (Mann-Whitney analysis, P>0.05)

  • PDF

자유낙하 콘관입시험법을 활용한 휴대용 다짐도 측정기의 실내시험을 통한 검증 연구 (A Study on the Verification of an Indoor Test of a Portable Penetration Meter Using the Cone Penetration Test Method)

  • 박근현;양안승
    • 한국지반환경공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.41-48
    • /
    • 2019
  • 국내에 많은 도로공사, 공항공사, 항만공사, 구조물 되메우기 공사 등의 토목공사에서 흙의 다짐은 가장 중요한 공정 중 하나이다. 특히 도로공사에서 흙의 다짐공사는 노체다짐과 노상다짐으로 구분하며 다짐도 부족으로 부실공사의 원인으로 작용하기도 하는 중요한 작업이다. 현재는 여러 가지 다짐도 측정방법이 있으나 가장 많이 사용되는 평판재하시험이나 모래치환법에 의한 흙의 단위중량 시험방법을 가장 많이 사용하고 있으나 경제성이 없어 여러 측정방법이 개발되고 있다. 간편한 다짐도 측정 방법의 목적으로 측정기를 개발하고 제작한 것이 자유낙하 관입깊이별 다짐도 시험기(Free-Fall Penetration Test; FFPT)이다. 본 연구에서는 실내시험을 위하여 균질한 시료를 공사현장에서 확보하여 체가름 시험을 통해 흙을 분류하고 입도분석시험과 비중시험을 실시하였다. 자유낙하 관입깊이별 다짐도 시험기(FFPT)의 원리는 지구중력을 이용한 자유낙하 물체의 선단에 설치된 관입 침이 노체 또는 노상의 다짐이 완료된 노면에 관입 되는 깊이를 관측하고 그 위치에 모래치환법에 의한 흙의 단위중량시험을 통하여 다짐도 값을 구하여 분석하고 연관성을 검증하는 것으로 흙의 최대허용입경이 2.36mm로 시험하였으며 $A_1$다짐의 경우는 낙하고 10cm에서 시험한 결과 값으로 추세선을 작성하고 추세선의 결정계수 $R^2=0.8677$ 값을 도출하였으며 $D_2$다짐의 경우는 낙하고 20cm에서 측정 시 결정계수 $R^2=0.9815$ 값이 관측되었다. 자유낙하시험은 낙하높이를 10cm에서 50cm까지 10cm 간격으로 변경을 하면서 시험하였다. 본 연구는 모래치환법에 의한 흙의 단위중량시험을 통하여 얻은 다짐도 값과 FFPT 시험기를 통해 얻은 관입침의 관입깊이와의 연관성을 비교 분석하여 현재의 다짐도 측정방법의 단점인 시간, 장비, 인력의 소모를 최소화하여 경제성을 확보하고 정확성과 간편성을 보장하는 다짐도 측정기 제작으로 여러 공사현장에서 다짐도 측정이 간단하게 진행될 것이다.

휴대용 다짐도 측정기의 현장실험을 통한 다짐도와 관입깊이 상관성 연구 (A Study on the Correlation with the Degree of Compaction and the Penetration Depth Using the Portable Penetration Meter at Field Test)

  • 박근현
    • 한국지반환경공학회 논문집
    • /
    • 제19권11호
    • /
    • pp.5-14
    • /
    • 2018
  • 전 세계적으로 토목공사 현장에서 토사의 다짐작업은 중요한 공종 중 하나의 공종이다. 특히 도로공사에서의 다짐작업은 공사 후에도 부실시공과 밀접한 관계를 가지고 있으므로 매우 중요하게 평가된다. 현재는 여러 가지 다짐도 측정방법 중에 평판재하시험이나 모래 치환법에 의한 흙의 단위 중량 시험방법을 가장 많이 사용하고 있으나 많은 시간과 장비가 필요하며 인력도 많이 소모되어 경제성을 확보하지 못하고 있다. 본 연구에서는 중력에 의한 자유낙하 물체의 관입 깊이에 따라 다짐도 측정방법인 자유낙하 관입깊이별 다짐도 시험(Free-Fall Penetration Test, FFPT) 일명 휴대용 다짐도 측정기를 이용하여 현장실험을 실시하여 다짐도와 관입깊이 그래프를 작성하였고 낙하고 10cm에서 결정계수 값이 0.963으로 가장 정확도가 높았으며 그래프는 가로축과 세로축 모두 10진법 그래프로 작성하였으며, 허용오차범위는 관입깊이 기준으로 ${\pm}1.28mm$로 작성되었다. 휴대용 다짐도 측정기를 통하여 현장에서 간단하고 신속, 정확한 다짐도 측정이 가능하여 경제성 확보와 공정 관리가 편리하게 진행될 것이다.

복합레진 충전술식에 따른 조미료(장류)의 와동변연 색소 침투에 관한 연구 (A STUDY ON THE COLOUR PENETRATION OF KOREAN FOODS SUBSTANCE TO CAVITY MARGIN OF COMPOSITE RESIN RESTORATION)

  • 안상훈
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.69-76
    • /
    • 1982
  • The purpose of this study was to evaluate the color penetration of cavity margin with composite resin restorations in some Korean foods substance-soy sauce and hot bean paste. Fifty specimans which were extracted caries free third molar of young adults recently. All of the prepared 100 cavities were filled with two kinds of composite resin (Hipol$^{(R)}$and Restodent$^{(R)}$). The experimental specimans were divided into five groups by the following procedures. Group I : Filling of composite resin and polishing. Group II : Filling, polishing, etching of cavity and sealing. Group III : Etching, sealing, filling and polishing. Group IV : Etching, sealing, filling, polishing, and repeated of etching of cavity margin and sealing. Group V : Etching, sealing, filling, polishing, and sealing again without etching. Before examination, the restorated teeth were subjected to thermal cycling ($4^{\circ}C$ and $60^{\circ}C$). All the specimens were immersed in soy and 30% hot bean paste solution under $37^{\circ}C$ incubator during six weeks. Then, the specimens were sectioned bucco-lingually through the center of two restorations with diamond disk and examined under a. metallographic microscope. (Union 6617 U.S.A.) Thereafter, the degree of color penetration was calculated and analyzed. The obtained results were as follows: 1. The color penetration was the lowest in the procedure of Group III which was acid etching, sealing, composite resing filling, and polishing. 2. The color penetration occured in soy and hot bean paste, but the degree of penetration was not so significant statistically between them. 3. The degree of color penetration was not so significant statistically between Hipol$^{(R)}$ and Restondent$^{(R)}$.

  • PDF