• Title/Summary/Keyword: Degree of Superheat

Search Result 44, Processing Time 0.029 seconds

Effect of degree of superheat of LiBr aqueous solution on the vapor absorption process for an air-cooled absorption cooling system (공냉형 흡수식 냉방 시스템에서 LiBr 수용액의 과열도가 증기 흡수에 미치는 영향)

  • Kim, S.C.;Oh, M.D.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-133
    • /
    • 1997
  • Numerical analysis using finite volume method has been carried out to examine the effect of degree of superheat of LiBr aqueous solution on heat and mass transfer occurred in absorption process. According to the result of this study, it was found that refrigerant vaper was generated at the entrance region of absorber when LiBr aqueous soltion was superheated. As the degree of superheat increases, heat transfer rate increases and vapor absorption rate decreases. The increase in averaged Nusselt and Sherwood numbers could be found as film Reynolds number increases. The larger the degree of superheat, the greater the averaged Nusselt and Sherwood numbers.

  • PDF

Spray Characteristics of a Pressure Swirl Nozzle for an Ambient Condition due to Flash Boiling (감압 비등에 의한 상압 환경에서의 압력식 와류 노즐의 분무 특성)

  • Kim, Won-Ho;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.686-691
    • /
    • 2010
  • Flash boiling takes place when the thermodynamic state of the liquid deviates from its saturation limit over which the liquid temperature exceeds by a certain degree of superheat. The liquid jet introduced into the lower pressure zone than the liquid saturation pressure experiences a sequence of the atomization and disintegrated into numerous faster and smaller droplets. In the present study spray characteristics for a flash swirl spray were experimentally investigated. Injectant temperature is raised by a high frequency dielectric heating method and local spray characteristics are instantly measured by Global Sizing Velocimetry (GSV, TSI Inc.). Dependence of dimensionless superheat degree and injection pressure on total and local SMDs and mean droplet size is quantitatively examined. The flash swirl spray has the relation in the injection pressure and nozzle diameter in order to determine the spray quality, including the dimensionless superheat degree. Small droplets occur in the void core and local droplet size distributions largely depend on the dimensionless superheat degree and the injection pressure.

  • PDF

The Study on the Performance Characteristics due to the Degree of Superheat in $NH_3$ Refrigeration System III - The Comparison of Heat Exchanger Types -

  • Hong Suck-Ju;Ha Ok-Nam;Lee Kyu-Tae;Ha Kyung-Soo;Jeong Song-Tae;Hong Seong-In;Yun Kab-Sig;Kim Yang-Hyun;Kwon Il-Wook;Lee Jong-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Because the usage of CFC and HCFC based refrigerants are restricted due to the depletion of ozone layer, the $NH_3$ gas, in the experiment is evaluated to the performance characteristics for the superheat control to improve the energy efficiency. The experiment is carried out about the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa through the degree of superheat from 0 to $10^{\circ}C$ at each condensing pressure. As a result, in the case of shell and tube type of heat exchanger, the COP is more efficient than other cases at the degree of superheat $1^{\circ}C$ at each condensing pressure. In the case of shell and disk type of heat exchanger, the COP is the most efficient at the degree of superheat 0.

An Application of Optimum Heat Exchanger for the Grasp on Performance Characteristics of $NH_3$ Refrigeration System

  • Ha Ok Nam;Kwon Il Wook;Hong Suck Ju;Kim Jae Yeol;Lee Jong In;Jeon Sang Sin;Ha Kyung Soo;Lee Seung Jae;Park Chan Soo;Jeong Song Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants is to be restricted due to the depletion of ozone layer, this experiment applies the $NH_{3}$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa by 50kPa and for degree of superheat from $0^{circ}$ to $1^{circ}$ by $10^{circ}$ at each condensing pressure. As a result of experiment, 1) As degree of superheat increased, evaporating pressure of the compressor decreased so equilibrium temperature decreased. And specific volume of refrigerant vapors increased so refrigerant mass flow and heat load of the evaporator decreased. 2) An influence of change of condensing pressure on heat load of the evaporator was insignificant. 3) With the identical degree of superheat, change of compressed temperature was insignificant according to each condensing pressure, so there was little change in enthalpy.4) when the degree of superheat is $0^{circ}$C at each condensing pressure, the refrigeration system has the hi띤est performance.

The Study on Performance Characteristics of $NH_3$ Refrigeration System for Various Degree of Superheat - Part II : The Change of Heat Exchanger Type - ($NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구 II -열교환기 타입 변경-)

  • Ha Ok-Nam;Kwon Il-Wook;Jeon Sang-Sin;Lee Seung-Jae;Jung Song-Tae;Ha Kyung-Soo;Yun Kab-Sig;Lee Jong-In;Hong Kyung-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.297-302
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the $NH_3$ gas to study the performance characteristics of $NH_3$ refrigeration system by the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa and for degree of superheat from $0^{\circ}C\;to\;10^{\circ}C$ at each condensing pressure. As a result of experiment, when the degree of superheat is $0^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

Effect of LiBr solution flow rates in commercial absorption chiller (상용 흡수식 냉동기에서 LiBr 수용액 유량변화에 따른 영향)

  • Choi, S.H.;Chung, B.C.;Nam, L.W.;Jurng, J.;Chin, S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.292-297
    • /
    • 2001
  • This paper discusses the effect of varying LiBr solution circuits flow rates for a direct fired double effect commercial absorption chiller in the parallel flow configuration. The effects of solution flow rates have been investigated for generator, condenser, solution heat exchanger, absorber and evaporator. According to the result of this work, it was found that sensible heat rate of generator increases and refrigerant vapor generated in that decreases when inlet solution flow rate of that increases. As solution flow rate of absorber increases, the degree of superheat increases because of decreasing solution heat exchanger efficiency. The flashing vapor at the top of absorber increases in proportion to the degree of superheat whileas decreases cooling capacity inversely.

  • PDF

The Study on Performance Characteristics of $NH_3$ and R22 due to Structure of Heat Exchanger (열교환기 구조 변화에 따른 $NH_3$와 R22의 성능특성연구)

  • Ha Ok-Nam;Ha Kyung-Soo;Lee Seung-Jae;Jeong Song-Tae
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.60-65
    • /
    • 2005
  • Nowadays HCFCs refrigerant are restricted because it cause depletion of ozone layer. However, natural gases such as ammonia as an organic compound, propane and propylene as hydrocarbon are easy and cheap to obtain as well as environmental. Accordingly, this experiment apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 15bar to 16bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

  • PDF

An Experimental Study on the Superheated Liquid Jet (과열액체제트의 미립화에 관한 실험적 연구)

  • Lee J. G.;Lee S. Y.;Kim I. G.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.1
    • /
    • pp.89-102
    • /
    • 1987
  • Experiments have been carried out to study the atomisation characteristics of superheated liquid(water) jet injected into the atmosphere through a single-hole nozzle. In present experi-mental range, superheated liquid jet has been observed to be atomised in two-phase effluent type; that is, spray formed by the bubble nucleation in the nozzle. In case of liquid injection through a long nozzle (L/D=29.09), the critical superheat for occurrence of two-phase effluent atomisa-tion can be determined from sudden change of spray angle. Sauter mean diameter of the spray droplets decreases as the degree of superheat increases. For the short nozzle (L/D=7.27), mean diameter increases with the injection pressure, while it decreases for the long nozzle; however for the long nozzle the effect of injection pressure is not significant compared with the short nozzle. For the short nozzle the uniformity of drop size distribution increases with increasing the degree of superheat, but for the long nozzle the effect of superheat on the uniformity is not appreciable.

  • PDF

An Experimental Study on Performance Characteristics of Refrigeration System Using R134a Refrigerating System (R134a를 이용한 냉동장치의 성능특성에 관한 실험적 연구)

  • Kim, Jin-Hyun;Kim, Jong-Kil;Kim, Sung-Bae;Ha, Ok-Nam
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2188-2193
    • /
    • 2007
  • Since the use of CFCs and HCFCs refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the R134a gas to study the performance characteristic from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1.5 MPa to 1.6 MPa by 0.05 MPa and for superheat temperature from 0$^{\circ}C$ to 5$^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

  • PDF