• 제목/요약/키워드: Degraded Control

검색결과 408건 처리시간 0.027초

Smart Gateway VPN Tunneling Control System based on IoT (IoT 기반 스마트 게이트웨이 VPN 터널링 제어 시스템)

  • Yang, Seungeui;Kim, Changsu;Lee, Jongwon;Jung, Hoekyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.575-576
    • /
    • 2017
  • Recently, research have smart gateways can provide additional services through the IoT and Big Data. However, the existing System is number of devices connected increases to the Server, the stability of the network is degraded and data security is poor. In this paper, we design a smart gateway VPN tunneling control system based on IoT to solve these problems. we propose an effective VPN tunneling technology for low-end targets such as routers, and a method for efficiently controlling traffic in real-time in an environment where the quality of the Internet line changes dramatically. It is possible to control the sensor in the home safely through the VPN at the remote place.

  • PDF

The Effects of Pulsed Elctromagnetic Fields on Expression of Neurotrophic Factors after Spinal Cord Hemisection in Rats

  • Kang, Ji-Hyuk;Park, Sang-Young;Lee, Yun-Seob
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.253-258
    • /
    • 2011
  • The purpose of this study was to identify the effect of pulsed electromagnetic fields on the expression of neurotrophic factors after spinal cord injury. Sprague-Dawley male rats were given a spinal cord hemisection and randomly divided into 2 groups, the control and experimental groups. The experimental group was administered a fifteen minutes session of pulsed electromagnetic field once a day, five days a week. In order to observe the effect of these pulsed electromagnetic fields, this study observed the BDNF expression in the rat's lumbar spinal cord and the H&E staining in the gastrocnemius at 3, 7, 14, 21 days group after spinal cord hemisection. The results of this showed that the immunoreactivity of the BDNF in the rat's spinal cord gradually increased in each group. At 21 days, there is a significant difference between the control and experimental groups. The morphological shape of the gastrocnemius was gradually changed from 3days to 21days, and the gastrocnemius at 21 days was significantly degraded. However, the experimental group showed a slightly more organized gastrocnemius than the control group at 21days. The Results of this study suggest that pulsed electromagnetic field application decreases the degeneration of a rat's gastrocnemius morphology, and increases the immunoreactivity of the BDNF in the rat's spinal cord after spinal cord hemisection.

Link Layer Traffic Control Algorithm to Improve the Performance of WLANs (무선 랜 성능 향상을 위한 링크 계층 트래픽 제어 알고리즘)

  • Choi, Sun-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제12권4호
    • /
    • pp.758-765
    • /
    • 2008
  • Wide-spread deployment of infrastructure WLANs has made Wi-Fi an integral part of today's Internet access technology. WLANs suffer from degraded system throughput and each node's throughput fluctuates significantly in the saturation regime. In this paper, we propose a link layer traffic control mechanism which controls the offered load of DCF system. It is shown that the link layer traffic controller can improve DCF system throughput and reduce nodes' throughput fluctuation with properly controlled offered load. We propose a dynamic traffic control algorithm which can find an optimal offered load and show its performance improvement with ns-2 simulation.

T2PC: Temperature-aware Transmission Power Control Scheme for Wireless Sensor Networks (무선 센서 네트워크를 위한 온도인지형 전송파워 제어 기법)

  • Lee, Jung-Wook;Chung, Kwang-Sue
    • Journal of KIISE:Information Networking
    • /
    • 제37권5호
    • /
    • pp.403-408
    • /
    • 2010
  • The sensor nodes can be installed in the environment in which the temperature change is considerable, such as desert, urban, and data center. Particularly, because the output power becomes less than the targeted power if a temperature is increasing, link quality is degraded and packet losses are occurred. In order to compensate the temperature changes, existing schemes detect the change of the link quality between nodes and control transmission power through a series of feedback process. However, these approaches can cause heavy overhead by additional control packets. In this paper, we propose the T2PC(Temperature-aware Transmission Power Control) to keep up the link quality despite temperature variation. At each node, T2PC compensates the attenuated link quality by controlling the transmission power based on the local temperature measurement. In addition, the packet reception ratio can be improved with less control packets than ones required in existing transmission power control methods based on the feedback control.

An enhanced VS/VD switching algorithm to support fairly ABR service in ATM (ATM 망에서 공정한 ABR 서비스를 제공하는 확장된 VS/VD 스위칭 알고리즘)

  • 양해권;전광탁
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제4권2호
    • /
    • pp.313-322
    • /
    • 2000
  • The ATM Forum has been focusing on flow control mechanism for ABR traffic management. The goal of this activity is to efficiently manage the leftover network bandwidth and fairly distribute it among contending ABR VC so that communication links can be optimally utilized. ABR traffic is difficult to predict traffic shape because it has bursts and variable behavior. Also it's sensitive to lose but not to delay. This behavior makes difficult to UPC function in network and cause of congestion in switch, thus performance is degraded. To resolve this problem, various flow control mechanism has been worked in the ATM Forum. Especially, the rate-based flow control mechanism for ABR traffic has been standardized in the ATM Forum, Sept. 1994. Thus, various flow control mechanism has been working which likes EFCI, ER, VS/VD. VS/VD control is superior than existed ER control because it isolate different networks from each other. In this paper, we propose an expanded VS/VD flow control algorithm and compare with existed VS/VD flow control algorithm. Simulation result shows that this algorithm improve a problem in aspect of delay and fairness.

  • PDF

Early Rate Adaptation Protocol in DiffServ for Multimedia Applications (멀티미디어 서비스를 위한 DiffServ 망에서의 빠른 혼잡 제어 알고리즘)

  • Park Jonghun;Yoo Myungsik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제30권1B호
    • /
    • pp.39-46
    • /
    • 2005
  • As the multimedia application traffic takes more portion in the internet traffic, it is necessary to control the network congestion through the congestion control protocol. In addition, the QoS-enabled networks such as DiffServ become an indispensable technology when running the multimedia applications. However, the previously proposed end-to-end congestion control algorithms take the round trip time to react the network congestion. Thus, as the RTT becomes larger, the reaction against the congestion gets delayed further, while the network congestion gets worse. In addition the performance of end-to-end congestion control algorithm is degraded if the QoS-enabled network runs the congestion control mechanism in the network level without any coordination between them. In this paper, we propose the early rate adaptation protocol for the DiffServ network which effectively linke the congestion control algorithm at the host and the congestion mechanism in the network together. By taking advantage of early congestion notification from the network it is possible to react the network congestion more quickly and effectively.

An ABR Service Traffic Control of Using feedback Control Information and Algorithm (피드백 제어 정보 및 알고리즘을 이용한 ABR 서비스 트래픽제어)

  • 이광옥;최길환;오창윤;배상현
    • Journal of Internet Computing and Services
    • /
    • 제3권3호
    • /
    • pp.67-74
    • /
    • 2002
  • Asynchronous transfer mode (ATM) can be efficiently used to transport packet data services. The switching system will support voice and packet data services simultaneously from end to end applications. To guarantee quality of service (QoS) of the offered services, source rate to send packet data is needed to control the network overload condition. Most existing control algorithms are shown to provide the threshold-based feedback control technique. However, real-time voice calls can be dynamically connected and released during data services in the network. If the feedback control information delays, quality of the serviced voice can be degraded due to a time delay between source and destination in the high speed link, An adaptive algorithm based on the optimal least mean square error technique is presented for the predictive feedback control technique. The algorithm attempts to predict a future buffer size from weight (slope) adaptation of unknown functions, which are used for feedback control. Simulation results are presented, which show the effectiveness of the algorithm.

  • PDF

Predictive Current Control of a Grid-Connected Inverter with Grid Voltage Observer (계통전압 관측기를 이용한 계통연계형 인버터의 예측전류제어)

  • Lee, Kui-Jun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.159-166
    • /
    • 2010
  • For a grid-connected inverter in distributed generation systems, the current control is essential, and recently, the predictive current control based on a high performance digital signal processors (DSP) to satisfy a fast dynamic response has been widely investigated. However, the performance of predictive current control is degraded by the time delay due to digital implementation, the parameter and measured value errors and the interference of noise, and also theses make system even unstable. Therefore, this paper proposes the predictive current control using grid voltage observer for grid-connected inverter applications. To determine the relevant voltage observer gain, the low-order harmonics of grid voltage are considered, and the effect of filter parameter errors is analyzed. The proposed method has a fast current response capability, the robustness to noise and simple implementation due to voltage sensorless control and the robust current control performance to low-order grid harmonics. The feasibility of the proposed method is verified by simulation and experimental results.

Improvement of Initial Rotor Position Detection for Permanent-Magnet Synchronous Motor Using Magnetic Position Sensor (영구자석형 동기전동기에서 자기식 위치 센서를 사용한 초기 회전자 위치 검출 성능의 개선)

  • Park, Mun-Su;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제22권6호
    • /
    • pp.398-404
    • /
    • 2021
  • This paper proposes a method of using a magnetic position sensor to detect accurately the rotor position required to perform vector control of a permanent-magnet synchronous motor, particularly the initial rotor position at startup. In the existing vector control systems, the initial rotor position was determined using the output signals of the Hall sensors, or the control was performed in a sensorless method without using such a sensor. On the other hand, the accuracy is degraded due to the occurrence of a position detection error, and the practicality was not satisfactory. This paper attempts to detect the initial rotor position using a magnetic position sensor to solve this problem. This method is used to solve the deteriorating starting characteristics of the motor in the vector control system. In addition, to lower the price of a low-power vector control inverter, this paper proposes a method of integrating the existing sensors and reducing the price to less than half using a magnetic position sensor for speed and position detection.

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제20권1호
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF