• Title/Summary/Keyword: Degradation Detector

Search Result 110, Processing Time 0.033 seconds

A Modified Viterbi Algorithm for Word Boundary Detection Error Compensation (단어 경계 검출 오류 보정을 위한 수정된 비터비 알고리즘)

  • Chung, Hoon;Chung, Ik-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1E
    • /
    • pp.21-26
    • /
    • 2007
  • In this paper, we propose a modified Viterbi algorithm to compensate for endpoint detection error during the decoding phase of an isolated word recognition task. Since the conventional Viterbi algorithm explores only the search space whose boundaries are fixed to the endpoints of the segmented utterance by the endpoint detector, the recognition performance is highly dependent on the accuracy level of endpoint detection. Inaccurately segmented word boundaries lead directly to recognition error. In order to relax the degradation of recognition accuracy due to endpoint detection error, we describe an unconstrained search of word boundaries and present an algorithm to explore the search space with efficiency. The proposed algorithm was evaluated by performing a variety of simulated endpoint detection error cases on an isolated word recognition task. The proposed algorithm reduced the Word Error Rate (WER) considerably, from 84.4% to 10.6%, while consuming only a little more computation power.

Design and Fabrication of a W-band Total Power Radiometer (W-대역 Total Power Radiometer 설계 및 제작)

  • Jung, Myung-Suk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.103-110
    • /
    • 2006
  • We present a W-band radiometer to detect the metal targets on the ground environment. The type of the designed radiometer is the total power radiometer(TPR) for the simple configuration. The front end of the TPR consists of only the Mixer and LO for miniaturizing the system. Because the radiometer system does not use the low noise amplifier, we use matching circuits and a diode detector configured as a voltage doubler to compensate the degradation of sensitivity. We solve the temperature variation problems by filtering the reference voltages of the radiometer output signals. Through some experiments, we have verified that the designed radiometer system has good performances in detecting metal targets lying at several hundred meters.

Spectral resolution evaluation by MCNP simulation for airborne alpha detection system with a collimator

  • Kim, Min Ji;Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1311-1317
    • /
    • 2021
  • In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and an air filter, was developed. A collimator applied to the alpha detection system showed an enhancement in resolution and a degradation in detection efficiency. The resolution and detection efficiency were compared and analyzed to evaluate the performance of the collimator. Thus, the resolution was found to be more important than the efficiency as a determining factor of the detection system performance, from the viewpoint of radionuclide identification. The performance was evaluated on three properties of the collimator: hole shape, hole length, and the ratio between the hole and frame pitches. From the hole shape performance evaluation, a hexagonal collimator showed the highest resolution. Further, the collimator with a hole pitch of 14 mm was found to have the highest resolution while that with a frame pitch of 4-6 mm (i.e., 1.2-1.4 times longer than the hole pitch) showed the highest resolution.

Photo- and Sonic Degradation of Endosulfans(α, β, and sulfate) in Aqueous Solution (엔도설판류의 광 및 초음파분해)

  • Kwon, Sung Hyun;Kim, Jong Hyang;Cho, Daechul
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.460-465
    • /
    • 2007
  • Endosulfan-${\alpha}$ endosulfan-${\beta}$ and endosulfan-sulfate, which are classified as pesticides, were degraded by use of UV energy and ultrasonic irradiation. The degradation residuals were analysed by gas chromatography with an electron capture detector and TOC (total oragnic carbon) analysis. The reactions were conducted in a quartz annular reactor equipped with a low pressure mercury multilamp (8Wx2) and a sonic generator. All the aqueous solutions were concentrated as 10 mg/L initially. Endosulfans were degraded each to result in 48.2% (${\alpha}$), 50.0% (${\beta}$) and 76.5% (sulfate) of removal efficiency by UV energy, and 66.9% (${\alpha}$), 55.8% (${\beta}$) and 72.7% (sulfate) by ultrasonic irradiation, respectively. In contrast to the results of the single-component solutions, degradation of the endosulfan-sulfate was greatly suppressed to result in the lowest degradation rate and removal efficiency in the three-component solutions. This finding suggests that there should be a reversible reaction with a substantially low equilibrium constant between endosulfan-${\alpha}$ or -${\beta}$ and -sulfate in the coexistence of the three endosulfans. TOC data showed the endosulfans were decomposed by 20%~40% toward complete mineralization, producing a quantity of intermediates induced by the radical reactions. We found that all the decay reactions considered in this study nicely fell into pseudo first-order rate.

Design of a W-band Radiometer Simultaneously Operating with a Single-Antenna Configured FMCW Radar (단일 안테나를 사용하는 FMCW 레이더와 동시 운용이 가능한 W-대역 레디오미터 설계)

  • Jung Myung-Suk;Kim Wan-Joo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.4 s.346
    • /
    • pp.67-74
    • /
    • 2006
  • We present the design of a radiometer in W-band which operates simultaneously with a single antenna configured FMCW radar. We choose a total power radiometer(TPR) which shares an antenna and a front-end with the radar for miniaturizing the system. We separate the radiometer signal from the radar signal using a diplexer in IF band. Because the radiometer has an unwanted transmitter section due to the common use of the MMW front-end with the radar, some additional noise signals caused by the transmitter degrade the sensitivity of the radiometer system. To compensate the degradation of sensitivity, we use matching circuits and a diode detector configured as the voltage doubler. Through some experiments, we have verified that the designed radiometer system has good performances in detecting metal targets tying at several hundred meters.

The Concentrations of PCBs in the Serum and Theri Predictors of Exposure n Korean Women (일부 한국 성인 여성들의 혈중 PCBs 농도 및 그 노출요인의 연구)

  • 민선영;정문호;이강숙;노영만;구정환
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.97-107
    • /
    • 2000
  • PCBs [Polychlorinated biphenyls] are halogenated aromatic compounds with the empirical formula C12H10-nCln(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors, transformers, plasticizers, lubricant inks, and paint additives. once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their high degree of lipophilicity. In 1970s, the worldwide production of PCBs seem to be still in use. The environmental load of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seem to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs I the serum samples of 112 women by GC/MSD(Hewlett Packard 5897 Gas Chromatography-Mass Chromatography Detector) and CG/ECD(Hewlett Packard 5890 series-II gas chromatography-Electron capture detector, U.S.A). The main results of this study were as follows; The mean and standard deviation of serum PCBs were 3.613, 0.759 ppb, respectively and median of it was 3.828 ppb. The correlation coefficients of the concentrations of 13 PCB congeners ranged from 0.7913 to 0..9985 and were significantly correlated between each items(p=0.0001). The PCB concentrations were positively associated with age(simple linear regression; R2=0.86, =0.08023, p<0.001) and with total lipids in serums(simple linear regression; R=0.7058, =0.00486, p<0.001). The age adjusted model (Y=$\beta$0+$\beta$1age+$\beta$2X) was applied for possible predictors of PCBs levels in serum. For BMI(Body Mass Index), major residential area, and fish, meat, and dairy consumption, there was no association with PCBs levels, Also there was negative association for the number of pregnancy and lactation period with PCBs levels.

  • PDF

Object Detection and Optical Character Recognition for Mobile-based Air Writing (모바일 기반 Air Writing을 위한 객체 탐지 및 광학 문자 인식 방법)

  • Kim, Tae-Il;Ko, Young-Jin;Kim, Tae-Young
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.5
    • /
    • pp.53-63
    • /
    • 2019
  • To provide a hand gesture interface through deep learning in mobile environments, research on the light-weighting of networks is essential for high recognition rates while at the same time preventing degradation of execution speed. This paper proposes a method of real-time recognition of written characters in the air using a finger on mobile devices through the light-weighting of deep-learning model. Based on the SSD (Single Shot Detector), which is an object detection model that utilizes MobileNet as a feature extractor, it detects index finger and generates a result text image by following fingertip path. Then, the image is sent to the server to recognize the characters based on the learned OCR model. To verify our method, 12 users tested 1,000 words using a GALAXY S10+ and recognized their finger with an average accuracy of 88.6%, indicating that recognized text was printed within 124 ms and could be used in real-time. Results of this research can be used to send simple text messages, memos, and air signatures using a finger in mobile environments.

Development and Evaluation of a Thimble-Like Head Bolus Shield for Hemi-Body Electron Beam Irradiation Technique

  • Shin, Wook-Geun;Lee, Sung Young;Jin, Hyeongmin;Kim, Jeongho;Kang, Seonghee;Kim, Jung-in;Jung, Seongmoon
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.152-157
    • /
    • 2022
  • Background: The hemi-body electron beam irradiation (HBIe-) technique has been proposed for the treatment of mycosis fungoides. It spares healthy skin using an electron shield. However, shielding electrons is complicated owing to electron scattering effects. In this study, we developed a thimble-like head bolus shield that surrounds the patient's entire head to prevent irradiation of the head during HBIe-. Materials and Methods: The feasibility of a thimble-like head bolus shield was evaluated using a simplified Geant4 Monte Carlo (MC) simulation. Subsequently, the head bolus was manufactured using a three-dimensional (3D) printed mold and Ecoflex 00-30 silicone. The fabricated head bolus was experimentally validated by measuring the dose to the Rando phantom using a metal-oxide-semiconductor field-effect transistor (MOSFET) detector with clinical configuration of HBIe-. Results and Discussion: The thimble-like head bolus reduced the electron fluence by 2% compared with that without a shield in the MC simulations. In addition, an improvement in fluence degradation outside the head shield was observed. In the experimental validation using the inhouse-developed bolus shield, this head bolus reduced the electron dose to approximately 2.5% of the prescribed dose. Conclusion: A thimble-like head bolus shield for the HBIe- technique was developed and validated in this study. This bolus effectively spares healthy skin without underdosage in the region of the target skin in HBIe-.

Estimation and Characteristics of Atmospheric Deposition Flux of Polycyclic Aromatic Hydrocarbons (PAHs) into the Masan and Haengam Areas of Korea (마산과 행암 지역으로 유입되는 다환방향족탄화수소(PAHs)의 대기 침적 플럭스 산정과 특성)

  • Lee Su-Jeong;Moon Hyo-Bang;Choi Min-kyu
    • Journal of Environmental Science International
    • /
    • v.15 no.2
    • /
    • pp.121-131
    • /
    • 2006
  • Atmospheric bulk (wet and dry) samples were monthly collected in Masan and Heangam areas of Korea, to assess the deposition flux and seasonal variation of polycyclic aromatic hydrocarbons (PAHs). Deposition fluxes of PAHs in bulk samples were determined using gas chromatography coupled to mass spectrometer detector (GC/MSD). Particle deposition fluxes from Masan and Haengam areas varied from 13 to $87\;g/m^2/year$ and from 5 to $52\;g/m^2/year$, respectively. PAHs deposition fluxes in atmospheric bulk samples in Masan and Haengam areas ranged from 135 to $464\;{\mu}g/m^2/year$ and from 62.2 to $194\;{\mu}g/m^2/year$, respectively. Atmospheric deposition fluxes of particles and PAHs in this study were comparable to or slightly lower values than those from different locations in Korea and other countries. PAHs profiles of atmospheric deposition bulk samples showed slightly different from two sampling areas, however the predominant species of PAHs were similar. Indeno (1,2,3-c,d)pyrene, benzo(g,h,i)perylene, phenanthrene compounds were the most detected PAHs in deposition bulk samples. Carcinogenic PAHs occupied the contribution of approximately $30-40\%$ of the total PAHs deposition fluxes. The non-metric multi-dimensional scaling (MDS) was used, to assess the differentiation of PAHs source between two sampling areas. The result suggests that PAHs contamination sources were different according to the location and season surveyed. There was no an apparent relationship between the PAHs deposition flux against temperature and rainfall amount, even though summer season with the highest temperature and the largest amount of precipitation showed the lowest PAHs deposition flux. Benzo(e)pyrene/benzo(a)pyrene ratio indicated that the photo-degradation process was one of important factors to the seasonal variation of PAHs with the lower deposition fluxes.

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.