• Title/Summary/Keyword: Degenerative lumbar spinal stenosis

Search Result 42, Processing Time 0.023 seconds

Effectiveness of percutaneous epidural neuroplasty using a balloon catheter in patients with chronic spinal stenosis accompanying mild spondylolisthesis: a longitudinal cohort study

  • Myong-Hwan Karm;Chan-Sik Kim;Doo-Hwan Kim;Dongreul Lee;Youngmu Kim;Jin-Woo Shin;Seong-Soo Choi
    • The Korean Journal of Pain
    • /
    • v.36 no.2
    • /
    • pp.184-194
    • /
    • 2023
  • Background: Degenerative lumbar spondylolisthesis (DLS) is frequently associated with lumbar spinal stenosis (LSS) and conservative treatments such as epidural steroid injection do not have long-term benefits in LSS patients with DLS. This study evaluated the effectiveness of percutaneous epidural neuroplasty using a balloon catheter in patients with LSS and DLS. Methods: Patients' sex, age, body mass index, diabetes, hypertension, stenosis grading, pain duration, location, pain intensity, and medications were retrieved from electronic medical records. At 1, 3, and 6 months following the procedure, data on pain severity, medication usage, and physical functional status were analyzed. A generalized estimating equations model was used at the six-month follow-up. Patients were divided into those with DLS (the spondylolisthesis group) and those without DLS (the no spondylolisthesis group) to evaluate whether the effects of percutaneous epidural neuroplasty using a balloon catheter were different. Results: A total of 826 patients were included (spondylolisthesis: 433 patients, 52.4%; no spondylolisthesis: 393 patients, 47.6%). Age, body mass index, hypertension, pain location, and stenosis grading were statistically different between the two groups. The generalized estimating equations analyses with unadjusted and adjusted estimation revealed a significant improvement in the estimated mean numerical rating scale of pain intensities compared to that at baseline in both groups (P < 0.001). Any adverse events that occurred were minor and temporary. Conclusions: Percutaneous epidural neuroplasty using a balloon catheter may be an alternative treatment option for patients with chronic LSS, regardless of accompanying DLS, who have had failed conservative management.

Interspinous Implant with Unilateral Laminotomy for Bilateral Decompression of Degenerative Lumbar Spinal Stenosis in Elderly Patients

  • Ryu, Sung-Joo;Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.338-344
    • /
    • 2010
  • Objective : This study assessed the safety and efficacy of one level unilateral laminotomy bilateral decompression (ULBD) with the placement of a device for intervertebral assisted motion (DIAM) compared with one level ULBD only in elderly patients with degenerative lumbar spinal stenosis (DLSS). Methods : A non randomized prospective analysis was performed on 16 patients who underwent one level ULBD with DIAM (Group A) and 20 patients with one level ULBD only (Group B) between February 2007 and March 2008. Radiographic imaging, visual analog scale (VAS) and MacNab outcome scale were obtained before and after surgery at a mean interval of 21 months (range 17-27 months). Results : The disc height, interpedicular distance, slip distance and segmental lordotic angle were similar between two groups. In the group A, there was no significant difference between the pre- and post-operative imaging in terms of the sagittal balance and disc height. Both groups showed significant improvement in the clinical outcomes. In addition, there was significantly less low-back pain in the group A than in the group B at the last follow up, while the clinical improvement of the leg pain and MacNab outcome scale showed no significant difference in the two groups. There were no major complications or DIAM associated complications. Conclusion : ULBD with DIAM is a safe and efficacious treatment for selective elderly patients with DLSS, particularly for relieving low back pain comparing to ULBD. ULBD with DIAM did not alter the disc height or sagittal alignment at the mean 21 months follow-up interval.

Perioperative Results and Complications after Posterior Lumbar Interbody Fusion for Spinal Stenosis in Geriatric Patients over than 70 Years Old

  • Choi, Jong Min;Choi, Man Kyu;Kim, Sung Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.684-690
    • /
    • 2017
  • Objective : As increasing the size of the geriatric population, the number of elderly patients, who need the surgery for painful degenerative spinal stenosis has been increasing. The geriatric population may be relatively high complications, because of age and age-associated medical conditions. However, there is a lack of studies addressing the perioperative complications and outcomes in elderly patients with posterior lumbar inter body fusion with screw augmentation (PLIF). Methods : We retrospectively reviewed the medical records and radiographic studies of geriatric patients who had spine surgery of PLIF due to spinal stenosis for 11 years. We divided into 2 groups (A; 70-75 years, B; over then 76 years) according to the age. Surgical level of each groups, hospital day and postoperative day, co-morbidities, complications, clinical outcomes were analyzed. Operative reports, hospital and outpatient clinic charts, and radiographic studies were reviewed. Results : Group A was composed of 80 patients, their mean age was 72.21 and female dominant (n=46), and their mean surgically fused level was 1.52 level. Group B was 36 patients, their mean age was 78.83 and female dominant (n=20), and their mean surgically fused level was 1.36 level. Comparing between two groups, complications, postoperative hospital stay were slightly increase in group B and co-morbidity was statistically high in group B, however clinical outcomes were similar between two groups. Conclusion : Increasing age might be an important risk factor for complications in patients undergoing PLIF, however, we would like to recommend that if the situation of spine of extreme geriatric patients need PLIF, it should be in the surgeon's consideration after careful selection and clinical judgement.

Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility (요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계)

  • Park, Jung-Hong;Heo, Soon;Lee, Sung-Jae;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.

Accelerated L5-S1 Segment Degeneration after Spinal Fusion on and above L4-5 : Minimum 4-Year Follow-Up Results

  • Park, Jeong-Yoon;Chin, Dong-Kyu;Cho, Yong-Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.2
    • /
    • pp.81-84
    • /
    • 2009
  • Objective : Many biomechanical and clinical studies on adjacent segment degeneration (ASD) have addressed cranial segment. No study has been conducted on caudal segment degeneration after upper segment multiple lumbar fusions. This is a retrospective investigation of the L5-S1 segment after spinal fusion at and above L4-5, which was undertaken to analyze the rate of caudal ASD at L5-S1 after spinal fusion on and above L4-5 and to determine that factors that might have influenced it. Methods : The authors included 67 patients with L4-5, L3-5, or L2-5 posterior fusions. Among these patients, 28 underwent L4-5 fusion, 23 L3-5, and 16 L2-5 fusions. Pre- and postoperative radiographs were analyzed to assess degenerative changes at L5-S1. Also, clinical results after fusion surgery were analyzed. Results : Among the 67 patients, 3 had pseudoarthrosis, and 35 had no evidence of ASD, cranially and caudally. Thirteen patients (19.4%) showed caudal ASD, 23 (34.3%) cranial ASD, and 4 (6.0%) both cranial and caudal ASD. Correlation analysis for caudal ASD at L5-S1 showed that pre-existing L5-S1 degeneration was most strongly correlated. In addition, numbers of fusion segments and age were also found to be correlated. Clinical outcome was not correlated with caudal ASD at L5-S1. Conclusion : If caudal and cranial ASD are considered, the overall occurrence rate of ASD increases to 50%. The incidence rate of caudal ASD at L5-S1 was significantly lower than that of cranial ASD. Furthermore, the occurrence of caudal ASD was found to be significantly correlated with pre-existing disc degeneration.

The Biomechancial Effects of an Interspinous Spacer Implant on 3-D Motions for the Treatment of Lumbar Spinal Stenosis (요추부 척추관 협착증 치료를 위한 극돌기간 삽입술의 3차원 분석을 통한 생체역학적 효과 분석)

  • 이희성;신규철;문수정;정태곤;이권용;이성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1207-1210
    • /
    • 2004
  • As many humans age, degenerative lumbar spinal stenosis (DLSS) becomes a major cause of lower limb discomfort and disability. By surgical treatment method of DLSS, the existing surgical treatment methods using internal fixation have showed degeneration changes of an adjacent vertebrae and loss of lumbar spine lordosis-kyphosis due to eliminating a motion. For solving the problems of internal fixation, a novel interspinous spacer has been developed to treat DLSS by surgical treatment method. In this study, we evaluated the biomechanical effects of the interspinous spacer on the kinematics of the porcine lumbar spine before and after insertion of the implant. For this purpose, a device that is capable of measuring 3-D motions were built based on direct linear transformation (DLT) algorithm written with MATLAB program. Results showed that in extension, a change of the mean angle between the intact and the implanted specimens at L4-L5 was 1.87 degree difference and the implant reduced the extension range of motion of the L4-L5 (p&lt;0.05). But the range of motion in flexion, axial rotation and lateral bending at the adjacent segments was not statistically affected by the implant. In conclusion, we thought that interspinous spacer may have remedical value for DLSS by flexing human lumbar spine.

  • PDF

Minimum 3-Year Outcomes in Patients with Lumbar Spinal Stenosis after Bilateral Microdecompression by Unilateral or Bilateral Laminotomy

  • Yang, Sang-Mi;Park, Hyung-Ki;Chang, Jae-Chil;Kim, Ra-Sun;Park, Sukh-Que;Cho, Sung-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.194-200
    • /
    • 2013
  • Objective : Lumbar spine stenosis (LSS) can result in symptomatic compression of the neural elements, requiring surgical treatment if conservative management fails. Minimally invasive surgery has come to be more commonly used for the treatment of LSS. The current study describes outcomes of bilateral microdecompression by unilateral or bilateral laminotomy (BML) for degenerative LSS after a minimum follow-up period of 3 years and investigates factors that result in a poor outcome. Methods : Twenty-one patients who were followed-up for at least 3 years were included in this study. For clinical evaluation, the Japanese Orthopedic Association (JOA) scoring system for low back pain was used. The modified grading system of Finneson and Cooper was used for outcome assessment. Radiographic evaluation was also performed for spondylolisthesis, sagittal rotation angle, and disc height. Results : Twenty-one patients (10 men, 11 women) aged 53-82 years ($64.1{\pm}8.9$ years) were followed-up for a minimum of 3 years (36-69 months). During follow-up, two patients underwent reoperation. Average preoperative JOA score and clinical symptoms, except persistent low back pain, improved significantly at the latest follow-up. There were no significant differences in radiological findings preoperatively and postoperatively. Thirteen patients (61.9%) had excellent to fair outcomes. Conclusion : BML resulted in a favorable and persistent outcome for patients with degenerative LSS without radiological instability over a mid-term follow-up period. Persistent low back pain unrelated to postoperative instability adversely affects mid-term outcomes.

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

The association between pain, balance, fall, and disability in patients with lumbar spinal stenosis with vascular claudication

  • Gunes, Musa;Ozmen, Tarik;Guler, Tugba Morali
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.471-478
    • /
    • 2021
  • Background: The effect of lumbar spinal stenosis (LSS) and peripheral vascular disease (PVD), which occurs with similar degenerative conditions, when seen together, has not been studied. The aim of this study is to examine and compare the relationship between pain, balance, disability, fear of falling, and kinesiophobia in LSS patients with intermittent vascular claudication (IVC). Methods: Seventy-two patients diagnosed with LSS using magnetic resonance imaging participated in this study. Thirty-five patients with IVC symptoms and showing vascular lesions by lower extremity venous and arterial Doppler ultrasonography imaging were included in the IVC-LSS group. The pain, static balance, dynamic balance, disability, fear of falling, and kinesiophobia were evaluated using the numeric rating scale, single leg stance test, Time Up and Go (TUG), the Oswestry Disability Index (ODI), Fall Efficacy Scale-International (FES-I), and Tampa Scale for Kinesiophobia (TSK), respectively. Results: Age and female sex were found to be higher in the IVC-LSS group (P = 0.024; P = 0.012). The IVC-LSS group had a shorter single leg stance time and TUG test duration, pain intensity, ODI, FES-I, and TSK scores were higher than patients with LSS (P = 0.001). Pain, fear of falling, and kinesiophobia were moderately correlated with disability in the IVC-LSS group. No relationship was found between pain and dynamic balance. Also, the pain was not related to kinesiophobia. Conclusions: The findings indicated that IVC causes loss of balance and an increase in pain, disability, fear of falling, and kinesophobia in patients with LSS.

Minimally Invasive Lateral Lumbar Interbody Fusion: Indications, Outcomes and Complications (최소 침습적 외측 요추간 유합술: 적응증, 결과, 합병증)

  • Soh, Jaewan;Lee, Jae Chul
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • The aim of this review was to evaluate minimally invasive lateral lumbar interbody fusion on the latest update. Lumbar interbody fusion was introduced recently. This study performed, a literature review of the indications, clinical outcomes, fusion rate, and complications regarding recently highlighted minimally invasive lateral lumbar interbody fusion. The indications of lateral lumbar interbody fusion are similar to the conventional anterior and posterior interbody fusion in degenerative lumbar diseases. In particular, lateral lumbar interbody fusion is an effective minimally invasive surgery in spinal stenosis, degenerative spondylolisthesis, degenerative adult deformity, degenerative disc disease and adjacent segment disease. In addition, the clinical outcomes and fusion rates of lateral lumbar interbody fusion are similar compared to conventional lumbar fusion. On the other hand, non-specific complications including hip flexor weakness, nerve injury, vascular injury, visceral injury, cage subsidence and pseudohernia have been reported. Lateral lumbar interbody fusion is a very useful minimally invasive surgery because it has advantages over conventional anterior and posterior interbody fusion without many of the disadvantages. Nevertheless, nonspecific complications during lateral lumbar interbody fusion procedure remain a challenge to be improved.