• 제목/요약/키워드: Deformed steel bar

검색결과 54건 처리시간 0.02초

Tempcore 공정을 통해 제조된 600 MPa급 철근의 두께방향 미세구조 변화 분석 (Investigation of Through-thickness Microstructural Evolution in a 600 MPa-Grade Reinforced Steel Bar Manufactured by Tempcore Process)

  • 박지원;김현지;강신곤
    • 열처리공학회지
    • /
    • 제36권6호
    • /
    • pp.367-373
    • /
    • 2023
  • 600 MPa-grade deformed bar samples were manufactured by conventional hot rolling and subsequent Tempcore heat treatment processes. Considering the short-time water quenching step of the Tempcore process for hot-rolled steel, it is inevitable that the temperature profile of the deformed bar depends strongly on its position throughout the sample thickness. As a result, its microstructure can be easily divided into two regions, the surface and the core regions. The former is expected to have a fresh martensite microstructure under rapid cooling conditions, but self-tempering occurs due to the intense heat flow from the hot core region after the process. The latter is generally known to exhibit a mixed microstructure of ferrite and pearlite due to its slow cooling rate. In this study, detailed microstructural evolutions were examined through the thickness direction. The large variation of the microstructure through the thickness direction in the deformed bar samples is partly due to the easy carbon diffusion from the limited additions of alloying elements.

직봉의 기능을 포함한 합성보의 전단연결재 개발과 성능평가 (Development and Performance Evaluation of the Shear Connector of Composite Beam with Vertical Bars)

  • 김상섭;박동수;부윤섭
    • 한국강구조학회 논문집
    • /
    • 제23권6호
    • /
    • pp.725-736
    • /
    • 2011
  • 합성보에는 강재보와 철근콘크리트 슬래브의 경계면에서 작용하는 수평전단력에 저항하기 위해 전단연결재를 설치한다. 또한 일반적으로 강재보에는 거푸집용 철선일체형 데크플레이트가 주로 사용되는데 시공 중 데크플레이트의 탈락 및 낙하 등 안전을 확보하기 위해 철근트러스 거더가 끝나는 양단부의 상부철선에 직봉을 설치한다. 따라서, 본 연구는 이형철근과 강판을 이용하여 동등 이상의 내력을 확보하면서 직봉의 기능을 포함하는 새로운 형상의 전단연결재를 개발하고 활용하는 방안을 검토하였다. Push-out 실험결과, 이형철근과 강판을 사용한 전단연결재는 ${\phi}16$ 스터드커넥터 이상의 내력과 연성을 확보하였으며, 직봉과 전단연결재를 겸용하는 것이 가능한 것으로 나타났다.

GFRP 보강근의 이음성능 (Lap Splice Length of Glass Fiber Reinforced Polymer (GFRP) Reinforcing Bar)

  • 이창호;최동욱;송기모;박영환;유영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.120-123
    • /
    • 2004
  • The lap splice lengths of deformed steel reinforcing bars and GFRP bars were experimentally compared using beam specimens. The purpose was to evaluate the length required of the GFRP bar to develop strength at least equivalent to the conventional steel reinforcing bar. The main test variable was the lap splice length: 10, 20, 30 $d_b$ for the deformed steel bars and 20, 30, 40 $d_b$ for the GFRP bars. Two different types of GFRP bars were tested: (1) one with spiral-type deformation and (2) plain round bars. Elastic modulus was about 1/5 of the steel bars while the tensile strength was about 690 MPa for the GFRP bars. Nominal diameter of the GFRP bars and steel bars was 12.7 and 13 mm, respectively. Normal strength concrete (28-day $f_{cu}$ = 30 MPa) was used. For the conventional steel bars (SD400 grade), strength over 400 MPa in tension was developed using the lap splice length of 20 and 30 $f_{cu}$. Only $87\%$ of the nominal yield strength was reached with the lap splice length of 10 $d_b$. For the spiral-type deformed GFRP bars with $40-d_b$ lap splice length, 440 MPa in tension was determined. The maximum tensile strength developed of the GFRP bars with smaller lap splice lengths decreased. The plain GFRP bar was not effective in developing the tensile strength even with $40-d_b$ lap splice length. Development of the cracks on beam surface was clearly visible for the beams reinforced with the GFRP bars. Mid-span deflections, however, were significantly smaller than the comparable beams with conventional steel bars indicating potential ductility problem.

  • PDF

축력 및 전단력을 받는 RC 띠장-철골 보 접합부의 접합연결재 개발 (Development of Connection Details of RC Wale-Steel Beam Joint Subjected to Axile and Shear Load)

  • 김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권3호
    • /
    • pp.189-196
    • /
    • 2004
  • RC 띠장과 철골 보의 스터드 접합부는 RC 띠장의 춤이 제한되므로 스터드의 인장 및 전단성능이 저하되어 접합부의 휨 및 전단 저항성능이 감소될 수 있다. 특히 RC 띠장-철골 보 접합부는 토압 및 수압에 의한 압축력을 받는다. 본 논문은 압축력과 전단력을 받는 RC 띠장-철골 보 접합부를 대상으로 접합연결재를 개발하기 위한 실험적 연구를 나타내고 있다. 본 연구에서 개발된 접합연결재는 개방형 C형 철근, 폐쇄형 C형 철근, U형 철근 등이다. 실험을 통하여 개발된 접합연결재를 사용한 접합부의 전단성능이 스터드 접합부와 비교된다. 실험결과에서 개발된 접합연결재가 RC 띠장 철골보 접합부의 전단강도를 증가시키는데 매우 효과적임을 나타내었다.

GFRP Rebar의 부착성능에 관한 실험적 연구 (An Experimental Study on the Bond Characteristics of Glass Fiber Reinforced Polymer Rebar)

  • 박지선;유영찬;박영환;최기선;김형열;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.124-127
    • /
    • 2004
  • This study is to investigate the bond characteristics of glass fiber reinforced polymer(GFRP) reinforcing bars in concrete by pullout test experimentally. Three different types of GFRP bars with different surface deformations were considered in this study. Also, standard deformed steel reinforcing bar with or without epoxy-coating were included for the comparisons of bond strength. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendation of CSA(Canadian Standards Association) Standard S806-02. From the test results, it was found that small surface indentations contributed to increase the bond strength of GFRP bar significantly. Based on the limited test results till now, the bond strength of GFRP bar with sand-coated deformation commercially available in foreign market is around $80\%$ of that of steel deformed bars.

  • PDF

Bond strength prediction of steel bars in low strength concrete by using ANN

  • Ahmad, Sohaib;Pilakoutas, Kypros;Rafi, Muhammad M.;Zaman, Qaiser U.
    • Computers and Concrete
    • /
    • 제22권2호
    • /
    • pp.249-259
    • /
    • 2018
  • This paper presents Artificial Neural Network (ANN) models for evaluating bond strength of deformed, plain and cold formed bars in low strength concrete. The ANN models were implemented using the experimental database developed by conducting experiments in three different universities on total of 138 pullout and 108 splitting specimens under monotonic loading. The key parameters examined in the experiments are low strength concrete, bar development length, concrete cover, rebar type (deformed, cold-formed, plain) and diameter. These deficient parameters are typically found in non-engineered reinforced concrete structures of developing countries. To develop ANN bond model for each bar type, four inputs (the low strength concrete, development length, concrete cover and bar diameter) are used for training the neurons in the network. Multi-Layer-Perceptron was trained according to a back-propagation algorithm. The ANN bond model for deformed bar consists of a single hidden layer and the 9 neurons. For Tor bar and plain bars the ANN models consist of 5 and 6 neurons and a single hidden layer, respectively. The developed ANN models are capable of predicting bond strength for both pull and splitting bond failure modes. The developed ANN models have higher coefficient of determination in training, validation and testing with good prediction and generalization capacity. The comparison of experimental bond strength values with the outcomes of ANN models showed good agreement. Moreover, the ANN model predictions by varying different parameters are also presented for all bar types.

Bond strength of deformed steel bars embedded in geopolymer concrete

  • Barzan Omar, Mawlood;Ahmed Heidayet, Mohammad;Dillshad Khidhir, Bzeni
    • Advances in concrete construction
    • /
    • 제14권5호
    • /
    • pp.331-339
    • /
    • 2022
  • Geopolymer concrete (GPC) is one of the best substitute materials for conventional concrete in construction. The conventional concrete provided by Portland cement has a detrimental influence on the environment during its production. In this study, the bond strength, which is an important structural property, of deformed steel bars with slag-based GPC was measured. In accordance with the ASTM C234 procedure, bond strength was measured on 18 specimens of slag-based GPC with three sizes of steel bars and different embedded lengths. Two groups of GPC specimens with different compressive strengths, which were cured under ambient conditions, were tested. The results indicated that the bar diameter has a great effect on the bond strength, and the bond strength behavior of the slag-based GPC is comparable with that of conventional concrete. The ACI-318 Code for the bond strength of ordinary Portland cement concrete can be used conservatively to determine the bond strength of the GPC reinforced with deformed steel bars.

경량 고강도 강관 록볼트의 지보특성에 관한 연구 (A Study on the Support Characteristics of the High Strength Lightweight Steel Pipe Rockbolt)

  • 김종우;김명균;김동만;김경훈;백재욱
    • 터널과지하공간
    • /
    • 제24권5호
    • /
    • pp.395-403
    • /
    • 2014
  • 본 연구에서는 특수 재질의 경량 고강도 강관 록볼트를 개발하였다. 그라우트 주입확인시험을 실시하여 완전충전이 이루어지는지 알아보았고 인장시험을 통해 항복내하력을 조사하였으며 이를 기존의 이형봉강 록볼트와 비교하였다. 또한, RMR 분류등급이 서로 다른 국내 3개 현장에서 실시한 현장인발시험을 통해 본 록볼트의 강도 및 신장특성을 확인하였다. 개발된 록볼트는 이형봉강 록볼트에 비해 항복내하력이 클 뿐 아니라 경량이라 취급이 용이하며, 그라우트 완전충전 효과에 따라 부식성 환경에서 내구성이 클 가능성이 있는 것으로 생각된다.

지지부재로 이형철근을 설치하는 띠형 강보강재의 인발성능 평가 (The Evaluation for Pullout Performance of Steel Strip Reinforcements with Deformed-Bars as Transverse Members)

  • 정성규;김주형;조삼덕;이광우
    • 한국지반신소재학회논문집
    • /
    • 제12권4호
    • /
    • pp.77-86
    • /
    • 2013
  • 본 연구에서는 지지부재가 설치된 띠형 강보강재에 대한 실내인발시험을 수행하였다. 주문진 표준사를 사용하여 상대밀도 80%인 모형지반을 조성하였고, 지지부재의 개수를 0~2개로 구분하여 실내인발시험을 수행하였다. 상재압은 $50kN/m^2{\sim}200kN/m^2$까지 4단계로 구분하여 적용하였고, 1mm/min 속도로 강보강재를 인발하였다. 표면이 매끄러운 띠형 강보강재의 인발저항력은 보강재 표면과 지반 사이에서 마찰저항만 발현되기 때문에 인발 초기에 급격히 증가하다가 지속적으로 감소하는 경향을 나타낸다. 반면, 지지부재를 설치한 강보강재의 인발저항력은 마찰저항뿐만 아니라 수동저항도 함께 발현되므로 계속적으로 증가하는 것으로 나타났다. 보강재의 형태에 관계없이 최대인발저항은 상재압이 증가함에 따라 선형적으로 증가하는 것으로 나타났다. 지지부재를 1개 설치한 경우에 비해 지지부재를 2개 설치했을 때의 최대수동저항은 작게 나타났다. 이는 지지부재의 설치 간격 및 위치에 따라 지지부재에서 발현되는 수동저항의 크기가 다르기 때문에 나타나는 현상으로 판단되며, 지지부재 설치 위치 및 간격에 따른 추가 인발시험을 통해 확인할 필요가 있다.

CFT 교각 기초부의 거동특성 (Behavior of the Foundation of Concrete Filled Steel Tubular Pier)

  • 이하림;김희주;황원섭
    • 한국전산구조공학회논문집
    • /
    • 제24권5호
    • /
    • pp.491-498
    • /
    • 2011
  • 본 연구는 CFT 교각 기초부의 구조상세 개선을 목적으로 상용 유한요소해석 프로그램인 ABAQUS를 이용하여 축하중 및 횡하중을 받는 강재기둥 베이스플레이트 접합부의 전반적인 구조적 거동과 설계변수의 영향을 검토하고자 한다. 이를 위해 현행 교각 기초부의 설계기준을 분석하였고, 선행연구의 실험을 토대로 수치해석을 실시하여 해석기법의 타당성을 검증하였다. 검증된 해석기법을 이용하여 교각 기초부의 파괴형상 및 응력분포를 분석하였으며, 다양한 설계변수(베이스플레이트, 이형철근, 기둥의 강종 및 치수)가 전체 구조물에 미치는 영향을 비교분석하였다.