• 제목/요약/키워드: Deformed Reinforcing bar

검색결과 43건 처리시간 0.019초

Test of Headed Reinforcement in Pullout

  • Park, Dong-Uk;Hong, Sung-Gul;Lee, Chin-Yong
    • KCI Concrete Journal
    • /
    • 제14권3호
    • /
    • pp.102-110
    • /
    • 2002
  • Results of an experimental study on the pullout behavior of the headed reinforcement are presented. A total of 48 pullout tests was performed to evaluate pullout strengths and load-displacement behaviors in pullout of the headed bars. The square steel heads had gross area of 4 $A_{b}$ and thickness of $d_{b}$ The test program consisted of three pullout test groups: Simple and Edge pullout tests using plain concrete slabs, comparison of pullout performances between the standard hooks and the headed reinforcement, and pullout tests of headed reinforcement using reinforced concrete columns. Test variables included concrete strengths ( $f_{c}$' = 27.1MPa, 39.1MPa), reinforcing bar diameters (D16~D29), embedment depths (6 $d_{b}$~12 $d_{b}$), edge conditions, column reinforcement, and single-vs.-multiple bar pullout. Test results revealed that the heads effectively provided the pullout resistances of the deformed bars in tension. The load-displacement behaviors were similar between the 90-degree hooks and the headed reinforcement. When a multiple number of headed bars installed with small head-to-head spacings was pulled out, reinforcement designed to run across the concrete failure surface in a direction parallel to the headed bars helped improve the pullout performances of the headed reinforcement.t.ement.t.

  • PDF

고인성 섬유보강 시멘트 복합체의 인장강성 (Tension Stiffening of High Performance Fiber-Reinforced Cementitious Composites)

  • 윤현도;양일승;한병찬;복산양;전에스더;김선우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.441-444
    • /
    • 2004
  • This paper presnets the tensile behavior of 8 high performance fiber-reinforced cementitious composites (HPFRCCs) members, each reinforced with one deformed bar 16mm in diameter. The variables included HPFRCC(Ductal, steel cord and polyethylene hybrid fiber, PE fiber) versus normal concrete. Fibers used in HPFRCC significantly increased tensile strength, ductility, and tension stiffening of cementitious materials. For HPFRCC, after first cracking, tensile load continue to rise without fracture localization. Sequentially developed parallel cracks contributed to the inelastic strain at increasing stress level. After yielding of the reinforcing bars, HPFRCC showed increases in loads with increasing strains.

  • PDF

Seismic performances of RC columns reinforced with screw ribbed reinforcements connected by mechanical splice

  • Lee, Se-Jung;Lee, Deuck Hang;Kim, Kang Su;Oh, Jae-Yuel;Park, Min-Kook;Yang, Il-Seung
    • Computers and Concrete
    • /
    • 제12권2호
    • /
    • pp.131-149
    • /
    • 2013
  • Various types of reinforcement splicing methods have been developed and implemented in reinforced concrete construction projects for achieving the continuity of reinforcements. Due to the complicated reinforcement arrangements and the difficulties in securing bar spacing, the traditional lap splicing method, which has been widely used in reinforced concrete constructions, often shows low constructability and difficulties in quality control. Also, lap spliced regions are likely to be over-reinforced, which may not be desirable in seismic design. On the other hand, mechanical splicing methods can offer simple and clear arrangements of reinforcement. In order to utilize the couplers for the ribbed-deformed bars, however, additional screw processing at the ends of reinforcing bars is typically required, which often lead to performance degradations of reinforced concrete members due to the lack of workmanship in screw processing or in adjusting the length of reinforcing bars. On the contrary, the use of screw-ribbed reinforcements can easily solve these issues on the mechanical splicing methods, because it does not require the screw process on the bar. In this study, the mechanical coupler suitable for the screw-ribbed reinforcements has been developed, in which any gap between the reinforcements and sleeve device can be removed by grouting high-flow inorganic mortar. This study presents the uniaxial tension tests on the screw-ribbed reinforcement with the mechanical sleeve devices and the cyclic loading tests on RC columns with the developed coupler. The test results show that the mechanical sleeve connection developed in this study has an excellent splicing performance, and that it is applicable to reinforced concrete columns with a proper confinement by hoop reinforcement.

Experimental and analytical behaviour of cogged bars within concrete filled circular tubes

  • Pokharel, Tilak;Yao, Huang;Goldsworthy, Helen M.;Gad, Emad F.
    • Steel and Composite Structures
    • /
    • 제20권5호
    • /
    • pp.1067-1085
    • /
    • 2016
  • Recent research on steel moment-resisting connection between steel beams and concrete filled steel tubes has shown that there are considerable advantages to be obtained by anchoring the connection to the concrete infill within the tube using anchors in blind bolts. In the research reported here, extensive experimental tests and numerical analyses have been performed to study the anchorage behaviour of cogged deformed reinforcing bars within concrete filled circular steel tubes. This data in essential knowledge for the design of the steel connections that use anchored blind bolts, both for strength and stiffness. A series of pull-out tests were conducted using steel tubes with different diameter to thickness ratios under monotonic and cyclic loading. Both hoop strains and longitudinal strains in the tubes were measured together with applied load and slip. Various lead-in lengths before the bend and length of tailed extension after the bend were examined. These dimensions were limited by the dimensions of the steel tube and did not meet the requirements for "standard" cogs as specified in concrete standards such as AS 3600 and ACI 318. Nevertheless, all of the tested specimens failed by bar fracture outside the steel tubes. A comprehensive 3D Finite Element model was developed to simulate the pull-out tests. The FE model took into account material nonlinearities, deformations in reinforcing bars and interactions between different surfaces. The FE results were found to be in good agreement with experimental results. This model was then used to conduct parametric studies to investigate the influence of the confinement provided by the steel tube on the infilled concrete.

경량콘크리트의 부착특성에 대한 실험적 연구 (Experimental Study on Bond Strength of Deformed Bars in Artificial Lightweight Aggregate Concrete)

  • 조장세;나성준;김민숙;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제24권1호
    • /
    • pp.43-53
    • /
    • 2011
  • 철근 콘크리트 부재에서 부착강도는 콘크리트와 보강근 사이에 중요한 요소 중 하나이다. 본 실험에서는 인공경량골재를 사용한 경량콘크리트와 이형철근의 부착강도의 특성을 확인하기 위하여 인발실험을 수행하였다. 콘크리트의 압축강도, 이형철근의 직경과 묻힘길이를 변수로 하는 144개의 인발실험 시험체가 사용되었다. 보통콘크리트와의 비교를 위하여 물/시멘트 비 50%의 보통콘크리트의 인발실험을 수행하였으며, 실험을 통해서 부착응력-미끌림 관계와 파괴형상을 평가하였다. 물/시멘트 비에 따른 콘크리트의 압축강도가 증가할수록 부착강도는 증가하였다. 또한 인발실험을 토대로 회귀분석을 실시하여 경량 콘크리트의 부착응력에 대한 산정식을 제안하였다.

AFRP 보강근의 부착강도에 대한 실험적 연구 (Experimental Study on Bond Strength of AFRP Rebar in Normal Strength Concrete)

  • 최준호;박경찬;이영학;김희철;이재삼
    • 한국지진공학회논문집
    • /
    • 제13권1호
    • /
    • pp.9-16
    • /
    • 2009
  • 철근 콘크리트 부재에서 부착강도는 콘크리트와 보강근 사이에 중요한 요소 중 하나이다. 본 연구는 인발실험을 통해 AFRP 보강근의 부착강도에 대하여 실험하고, AFRP 보강근과 이형철근의 부착특성을 비교하여 나타내었다. 묻힘 길이와 보강근의 직경이 실험의 변수로 사용되었으며, 실험을 통해서 AFRP 보강근의 부착응력-미끌림 관계 및 파괴양상을 평가하였다. AFRP 보강근의 부착응력-미끌림 관계는 이형철근과 비슷한 양상을 보였으며, 보강근의 직경이 증가할수록 인발하중은 증가하나 부착응력은 비슷한 결과를 보였다. AFRP 보강근의 부착강도는 이형철근의 약 54%에 달하는 것으로 나타났다.

순환 굵은골재의 혼입률에 따른 콘크리트와 이형철근의 부착 거동 (Effect of Recycled Coarse Aggregate (RCA) Replacement Level on the Bond Behaviour between RCA Concrete and Deformed Rebars)

  • 장용헌;최기선;유영찬;김긍환;윤현도
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.123-130
    • /
    • 2010
  • 순환골재 콘크리트와 철근의 부착 거동 규명은 철근콘크리트 구조물에 순환골재를 적용하기 위해서 매우 중요한 요소이다. 이에 따라 이 연구에서는 콘크리트와 철근 상호간의 부착 거동을 평가하기 압축인발 실험을 수행하였다. 실험에 사용된 변수는 설계압축강도(21, 27, 40 MPa), 순환 굵은골재 치환율(0, 30, 60, 100%) 및 철근의 배근방향 및 위치(상단근, 하단근)로 하였다. 이 연구를 통하여 얻어진 실험 결과를 종합해 보면, V형 시험체의 경우 순환골재 치환율에 관계없이 상호 유사한 값을 나타내고 있으며 H형 시험체의 경우는 철근의 배근 위치에 영향을 받는 것으로 나타났으나 일부 HT형 시험체를 제외하고는 대부분 CEB-FIP 및 ACI 408 기준식에 의한 계산 값을 상회하는 것으로 나타나 재생골재 사용에 따른 성능 저하는 크지 않은 것으로 판단된다. HT형 시험체의 경우 순환골재 치환율 증가에 따라 골재 침하 현상이 크게 발생되며 불리딩 및 레이턴스에 의한 부착면적의 감소로 최대 부착응력이 다른 시험체에 비하여 낮게 나타났다. 전술한 바에 의하면 현행 규준에서 정하는 상부철근의 높이인 300 mm 이하(높이 225 mm)에서도 부착강도의 저하가 발생하며 이에 따라 현재 규준에서 제안하는 철근 위치 보정계수 1.3의 값의 수정과 신뢰성 확보가 필요할 것으로 판단된다.

스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구 (Experimental Study for GFRP Reinforced Concrete Beams without Stirrups)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.21-29
    • /
    • 2014
  • 본 연구에서는 GFRP 이형 보강근으로 휨보강된 보의 거동, 파괴유형과 강도를 평가하였다. 4개의 보 실험체들을 제작하여 실험을 수행하였다. 4점 하중재하 조건으로 단순지지된 GFRP로 보강 콘크리트 실험체의 거동과 하중-처짐을 관찰하였다. 전단배근으로 인한 거동의 불확실성을 배제하기 위하여 스터럽을 배근하지 않고 실험체를 제작하였다. 실험 변수는 전단지간비와 유효보강비이다. 실험체의 길이는 3,300 또는 $1,950mm{\times}200mm{\times}240mm$이고 순지간 2,900 또는 1,000mm이다. 전단지간비는 6.5와 2.5이며, GFRP 유효 보강근비는 $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$$0.634{\rho}_{fb}$이다. 실험 결과 모든 실험체는 전단파괴 되었으며 실험계획에 적용한 ACI 440.1R, CSA S806와 ISIS의 전단 강도식이 실제와 편차가 있음을 확인하였다.

부착특성을 고려한 철근콘크리트 부재의 휨 균열폭 산정 및 비교 (The Estimation and Comparison of Flexural Crack Width Considering Bonding Characteristics in Reinforced Concrete Members)

  • 고원준;민병철;박선규
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.579-588
    • /
    • 2006
  • 최근 고강도철근 및 프리스트레싱에 의한 유용성은 경제적이고 효과적으로 콘크리트 구조설계를 가능하게 되었다. 이러한 구조적 부재를 다루는 구조기술자가 직면하는 중요한 문제중 하나는 한계상태설계에서 사용성에 대한 기준으로 사용되는 균열폭의 제어이다. 특히 휨균열은 하중을 부담하는 부재에 대해서 안전성의 확보 및 사용성과 연성을 향상될 수 있도록 제어되어야 한다. 본 논문에서 제안된 방법은 Ikki에 의해서 수행된 양측인장시험법의 시험 결과를 이용하고 있다. 양측인장상태에서 이형철근에 대한 부착특성은 콘크리트면적과 리브면적에 의해서 고려된다. 제안된 방법에 의한 결과는 시험 결과와 비교되며, 기존 방법보다도 치수 및 단면제원의 변화, 철근의 방향을 고려하여 보다 정밀한 부착응력과 이에 대한 상대슬립의 관계를 제시한다. 부착특성은 무차원적 슬립량과 유효철근비에 의해서 고려된다. 제안식의 유효성은 시험체 실험자료에 의해서 검증되어진다.

반복하중시 철근 마디높이에 따른 부착 손상특성 (Effects of Bar Deformation Height on Bond Degradation Subject to Cyclic loading)

  • 이재열;김병국;홍기섭;최완철
    • 콘크리트학회논문집
    • /
    • 제15권1호
    • /
    • pp.17-24
    • /
    • 2003
  • 지진하중을 받는 철근콘크리트구조의 취성파괴의 원인은 철근과 콘크리트사이의 급속한 부착손상에 의해 발생되는 국부 부착-슬립이다. 본 연구는 반복하중하에서 부착손상에 대한 철근의 마디높이의 효과를 평가하는 것이다. 큰 상대마디면적을 가진 가공된 철근을 사용하여 부착 시험체를 제작하였다. 또 다른 변수로서 연직방향 철근에 의해 횡구속 철근량의 정도가 고려되었다. 실험결과로부터 에너지 소산력의 크기가 산정되고 여러 변수들에 대해서 비교되었다. 실험결과로서, 하중의 반복이 증가함에 따라 부착강도와 부착강성은 현저히 감소함을 알 수 있다. 횡구속량이 크고 상대마디면적이 큰 철근에서 단조하중시에 비해서 반복하중시의 부착강도의 감소가 줄어들고 국부부착저하를 지연시키는데 효과가 있음을 알 수 있다. 에너지 소산량 또한 횡구속량과 마디상대면적이 증가함에 따라 증가한다. 그러나, 마디가 매우 높은 철근의 부착실험에서 높은 강성 때문에 부착이 적은 슬립에서 손상을 입는다는 것을 알 수 있다. 본 연구는 반복하중하에서 부착저하기구를 이해하고 높은 상대마디면적을 가진 새로운 이형철근의 개발에 유용할 것이다.