• 제목/요약/키워드: Deflection Rate

검색결과 169건 처리시간 0.024초

Three dimensional analysis of reinforced concrete frames considering the cracking effect and geometric nonlinearity

  • Kara, Ilker Fatih;Dundar, Cengiz
    • Structural Engineering and Mechanics
    • /
    • 제31권2호
    • /
    • pp.163-180
    • /
    • 2009
  • In the design of tall reinforced concrete (R/C) buildings, the serviceability stiffness criteria in terms of maximum lateral displacement and inter-story drift must be satisfied to prevent large second-order P-delta effects. To accurately assess the lateral deflection and stiffness of tall R/C structures, cracked members in these structures need to be identified and their effective member flexural stiffness determined. In addition, the implementation of the geometric nonlinearity in the analysis can be significant for an accurate prediction of lateral deflection of the structure, particularly in the case of tall R/C building under lateral loading. It can therefore be important to consider the cracking effect together with the geometric nonlinearity in the analysis in order to obtain more accurate results. In the present study, a computer program based on the iterative procedure has been developed for the three dimensional analysis of reinforced concrete frames with cracked beam and column elements. Probability-based effective stiffness model is used for the effective flexural stiffness of a cracked member. In the analysis, the geometric nonlinearity due to the interaction of axial force and bending moment and the displacements of joints are also taken into account. The analytical procedure has been demonstrated through the application of R/C frame examples in which its accuracy and efficiency in comparison with experimental and other analytical results are verified. The effectiveness of the analytical procedure is also illustrated through a practical four story R/C frame example. The iterative procedure provides equally good and consistent prediction of lateral deflection and effective flexural member stiffness. The proposed analytical procedure is efficient from the viewpoints of computational effort and convergence rate.

Behavior of composite box bridge girders under localized fire exposure conditions

  • Zhang, Gang;Kodur, Venkatesh;Yao, Weifa;Huang, Qiao
    • Structural Engineering and Mechanics
    • /
    • 제69권2호
    • /
    • pp.193-204
    • /
    • 2019
  • This paper presents results from experimental and numerical studies on the response of steel-concrete composite box bridge girders under certain localized fire exposure conditions. Two composite box bridge girders, a simply supported girder and a continuous girder respectively, were tested under simultaneous loading and fire exposure. The simply supported girder was exposed to fire over 40% of its span length in the middle zone, and the two-span continuous girder was exposed to fire over 38% of its length of the first span and full length of the second span. A measurement method based on comparative rate of deflection was provided to predict the failure time in the hogging moment zone of continuous composite box bridge girders under certain localized fire exposure condition. Parameters including transverse and longitudinal stiffeners and fire scenarios were introduced to investigate fire resistance of the composite box bridge girders. Test results show that failure of the simply supported girder is governed by the deflection limit state, whereas failure of the continuous girder occurs through bending buckling of the web and bottom slab in the hogging moment zone. Deflection based criterion may not be reliable in evaluating failure of continuous composite box bridge girder under certain fire exposure condition. The fire resistance (failure time) of the continuous girder is higher than that of the simply supported girder. Data from fire tests is successfully utilized to validate a finite element based numerical model for further investigating the response of composite box bridge girders exposed to localized fire. Results from numerical analysis show that fire resistance of composite box bridge girders can be highly influenced by the spacing of longitudinal stiffeners and fire severity. The continuous composite box bridge girder with closer longitudinal stiffeners has better fire resistance than the simply composite box bridge girder. It is concluded that the fire resistance of continuous composite box bridge girders can be significantly enhanced by preventing the hogging moment zone from exposure to fire. Longitudinal stiffeners with closer spacing can enhance fire resistance of composite box bridge girders. The increase of transverse stiffeners has no significant effect on fire resistance of composite box bridge girders.

밀링가공의 절삭조건 검증시스템 개발

  • 김찬봉;양민양
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.428-433
    • /
    • 1993
  • In this paper, the fast algorithm to calculate cutting force of milling and its application to NC verification system have been studied. The fast force algorithm can calculate the maximum cutting force fastly during one revelotion of tool. The NC verification using the fast force algorithm can verify excessive cutting force which is the cause of deflection and breakage of tool, and can so adjust the feed rate as to manufacture with the maximum force criterion or maximum machining error criterion. So, the fast force algorithm has been added to the NC verification system, the NC verification system can verify the physical problems in NC code effectively.

  • PDF

THE COLLISION EFFECTS OF THE PARTICLES IN THE ACCRETION DISK

  • Yoo, K.H.
    • 천문학논총
    • /
    • 제11권1호
    • /
    • pp.125-137
    • /
    • 1996
  • The collision of two particles in the accretion disk may lead to be a mechanism of heat generation. By using hydrodynamic equations, the mean free path, the collision frequency and the deflection angle due to the collision of the particles are derived as a function of the mass accretion rate. The mean free path seems to be a smaller fraction compared to the dimension parameter of the system. The radiative flux in the disk is obtained under the influence of the collision of the particles.

  • PDF

볼엔드 밀링의 절삭조건 검증시스템 (Verification System for Cutting Condition of Ball-End Milling Process)

  • 김찬봉;양민양
    • 한국정밀공학회지
    • /
    • 제12권2호
    • /
    • pp.123-134
    • /
    • 1995
  • In this paper, the fast force algorithm has been studied so that it is used to calculate cutting forces and to develope the NC verification system. The NC verification using the fast force algorithm can verify excessive cutting force which is the cause of deflection and breakage of tool, and adjust the feed rate and spindle speed.

  • PDF

신형상 U형 하이브리드 합성보의 내화성능에 관한 연구 (Fire Resistance of U-shape Hybrid Composite Beam)

  • 김성배;김상섭;유덕수;최승관
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.379-388
    • /
    • 2013
  • 본 연구에서는 신형상 U형 하이브리드 합성보의 내화성능평가를 실시하였다. 내화성능평가는 세라믹계의 뿜칠재와 내화페인트로 구분하여 내화시험을 수행하였다. 시험 변수는 피복재의 종류(뿜칠재와 페인트)와 내화시간(2시간, 3시간), 하중가력 유무(재하와 비재하), 뿜칠재 두께 등이다. 내화성능평가 합성보는 기존 철골보로 인정을 받은 제품에 비해 내화성능이 향상되는 것을 확인할 수 있다. 그러나 내화성능 향상에 대한 정량적인 평가는 합성보 형상과 관련한 다양한 변수가 조합되므로 지속적인 검토가 필요할 것으로 판단된다.

Evaluating fire resistance of prestressed concrete bridge girders

  • Zhang, Gang;Kodur, Venkatesh;Hou, Wei;He, Shuanhai
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.663-674
    • /
    • 2017
  • This paper presents an approach for evaluating performance of prestressed concrete (PC) bridge girders exposed to fire. A finite element based numerical model for tracing the response of fire exposed T girders is developed in ANSYS. The analysis is carried out in three stages, namely, fire temperature calculation, cross sectional temperature evaluation, and then strength, deformation and effective prestress analysis on girders exposed to elevated temperatures. The applicability of the computer program in tracing the response of PC bridge girders from the initial preloading stage to failure stage, due to combined effects of fire and structure loading, is demonstrated through a case study, and validated by test data of a scaled PC box girder under ISO834 fire condition. Results from the case study show that fire severity has a significant influence on the fire resistance of PC T girders and hydrocarbon fire is most dangerous for the girder. The prestress loss caused by elevated temperature is about 10% under hydrocarbon fire till the girder failure, which can lead to the increase in deflection of the PC girder. The rate of deflection failure criterion is suggested to determine the failure of PC T girder under fire.

시멘트콘크리트 포장구조계의 층별물성 및 응력추정에 관한 연구 (A Study on Evaluation of Layer Moduli and Stresses in Cement Concrete Pavement System)

  • 이승원;김문겸;김수일;황학주
    • 대한토목학회논문집
    • /
    • 제10권1호
    • /
    • pp.47-56
    • /
    • 1990
  • 본 연구에서는 FWD시험의 표면 처짐곡선으로부터 시멘트 콘크리트 포장구조체의 물성 및 응력을 추정할 수 있는 역산반복기법을 개발하였다. 국내에 가설되어 있는 시멘트 콘크리트 포장구조체에 대한 요소설계를 실시하여 구한 모형들에 대하여 유한요소와 층탄성이론을 조합한 해석방법을 적용하여 처짐 특성 및 탄성 계수 추정식을 구하였다. 추정식에 의한 각 층의 탄성계수를 초기 탄성계수로 하고, 탄성계수 변화율과 처침 변화율의 관계를 이용하여 반복역산시 탄성계수 보정에 사용하였다. 각 고속도로 노선별로 효율적인 역산반복기법을 전산화하였으며, 수치모델을 통하여 신뢰성 및 타당성을 검증하였다.

  • PDF

함정탑재장비용 대용량 마운트의 성능시험평가 (Experimental Evaluation of the Performance of Large-Capacity Mounts for Naval Shipboard Equipments)

  • 문석준;김흥섭;박진우;박진호;오광석;정종안
    • 대한조선학회논문집
    • /
    • 제52권3호
    • /
    • pp.275-281
    • /
    • 2015
  • Mounts for shipboard equipment in naval ships play an important role for vibration and shock suppression. New large-capacity resilient mounts, SDR-D30 and SDR-D45, have been developed. This paper involves performance tests for the mount which have maximum load of 30 kN and 45 kN, respectively. The performance tests have been carried out for several mounts based on military standards, such as MIL-M-19863D(SH), MIL-M-21693C(SH), MIL-M-17508F(SH), and MIL-S-901D(NAVY). The test items consist of deflection at upper rate load test, dynamic stiffness, uniformity, static load-deflection(axial, transverse and longitudinal), drift test, fatigue test, and shock test. From these performance tests, it is confirmed that the two mounts have good performances based on military standards.

원격지시식 자기 compass 에 관한 연구(I) (The Research for Remote-indicating Magnetic Compass(I))

  • 이상집;임정빈
    • 한국항해학회지
    • /
    • 제10권1호
    • /
    • pp.81-100
    • /
    • 1986
  • Self-contained portable remote-indicating magnetic compass was designed and tested. Its sensing part consists of main scale disk of rotary encoder with photo-etched 180, oopaque slits and three pairs of light sources and detectors seperated by a transparent index scale, so that any angular deflection of main scale disk against the bowl may be detected optically. The outputs from the sensing part are transformed into digital ship's course indication by electronics unit which consists of operational amplifier, phase discriminator, up-down counter and counting starter circuit. The results from testign the above compass with turntable at variable rate of turn are as following : 1) The main scale disk deflection against the bowl can be detected without any disturbing influence to the freedom of its north-seeking function. 2) The digital indication resolution is found to be $\circ \pm$1 degree. 3) Misrepresenting indication can be avoided by ensuring dimension uniformity and arrangement accuracy of slits on main and index scale disks and by centering pivot in the encoder disk. 4) Indication resolution should be improved by modifying the signal processing and by doubling the number of slits on compass card. 5) Further study should be made on developing non-conductive compass liquid, analogue repeater driving system and more compact processing element.

  • PDF