• 제목/요약/키워드: Defect type

검색결과 1,074건 처리시간 0.033초

Development of non-destructive method of detecting steel bars corrosion in bridge decks

  • Sadeghi, Javad;Rezvani, Farshad Hashemi
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.615-627
    • /
    • 2013
  • One of the most common defects in reinforced concrete bridge decks is corrosion of steel reinforcing bars. This invisible defect reduces the deck stiffness and affects the bridge's serviceability. Regular monitoring of the bridge is required to detect and control this type of damage and in turn, minimize repair costs. Because the corrosion is hidden within the deck, this type of damage cannot be easily detected by visual inspection and therefore, an alternative damage detection technique is required. This research develops a non-destructive method for detecting reinforcing bar corrosion. Experimental modal analysis, as a non-destructive testing technique, and finite element (FE) model updating are used in this method. The location and size of corrosion in the reinforcing bars is predicted by creating a finite element model of bridge deck and updating the model characteristics to match the experimental results. The practicality and applicability of the proposed method were evaluated by applying the new technique to a two spans bridge for monitoring steel bar corrosion. It was shown that the proposed method can predict the location and size of reinforcing bars corrosion with reasonable accuracy.

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

뇌성마비아의 임상적 양상 (Clinical Features of Children with Cerebral Palsy)

  • 김선영;김재현;김찬문
    • 대한물리치료과학회지
    • /
    • 제5권3호
    • /
    • pp.651-658
    • /
    • 1998
  • Cerebral palsy is a neurodevelopmental impairment caused by a nonprogressive defect or lesion in single or multiple locations in the immature brain. The defect or lesion can occur in utero or during or shortly after birth and produces sensory-motor impairment that are usually evident in early infancy. The causes of cerebral palsy are not completely understood, certain prenatal, perinatal, and postnatal factors have been associated with cerebral palsy. This study was analysed the clinical features of 50 children with cerebral palsy (29 males and 21 females) in National Rehabilitation Hospital from March 17 to June 27, 1998. The time of initial visit was over than 12 months in 74%, and their cheif complains were delayed developments (78%). The preterm infants were 40% and the infants with low birth weight were 36%. The maternal age at childbirth was over than 30 years old in 52%. The most common type of cerebral palsy was spastic (54%), mixed (22%), athetosis and hypotonia (10% each), ataxia (4%). The cerebral palsy with preterm infants and low birth weight were more likely to have spastic type (P=0.002, P=0.023 each). The most preterm infants were born between 30 and 35 years old of maternal age, and there were statistical significance in difference (P=0.031).

  • PDF

식도중간부 식도게실: 1 수술 치험례 (One case report of mid-thoracic esophageal diverticulum)

  • 선경;최영호;채성수;김학제;김형묵
    • Journal of Chest Surgery
    • /
    • 제15권4호
    • /
    • pp.447-450
    • /
    • 1982
  • A 45 year old male officer was admitted due to upper substernal pain for 1 month, which was aggravated by swallowing. On past and family history, there was no specific history except heavy drinking. Simple chest x-ray revealed no specific abnormal findings. Preoperative esophagofiberscopy and Barium study showed midesophageal diverticulum, pulsion type, at about 2 cm below the left main bronchus. The opening of the diverticulum was located at the left posterolateral aspect of esophagus. Midesophageal false diverticulum, measuring 2 x 2 x 1 .S cm in size, was noted at about 5 cm under the aortic arch protruding through a slit-like muscular defect. After inversion of diverticular sac, interrupted sutures with 3-0 silks were done on muscular defect site, and mediastinal pleura was reinforced on the lesion with interrupted sutures. On 4th postoperative day, esophagography revealed no diverticulum or stenosis. Also esophagofiberscopy showed smooth mucosal tag without disturbance of passage. On 14th postoperative day, the patient was discharged uneventfully, and follow-up for 3 months after discharge revealed nothing abnormal symptoms. The authors report one case of midesophageal, pulsion type, false diverticulum.

  • PDF

버퍼층 삽입을 통한 박막 태양전지의 고효율화 시뮬레이션 (A simulation of high efficiently thin film solar cell with buffer layer)

  • 김희중;장주연;백승신;이준신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2011
  • a-Si 박막 태양전지는 a-Si:H을 유리 기판 사이에 주입해 만드는 태양전지로, 뛰어난 적용성과 경제성을 지녔으나 c-Si 태양전지에 비해 낮은 변환 효율을 보이는 단점이 있다. 변환 효율을 높이기 위한 연구 방법으로는 a-Si 박막 태양전지 단일cell 제작 시 high Bandgap을 가지는 p-layer를 사용함으로 높은 Voc와 Jsc의 향상에 기여할 수 있는데, 이 때 p-layer의 defect 증가와 activation energy 증가도 동시에 일어나 변환 효율의 증가폭을 감소시킨다. 이를 보완하기 위해 본 실험에서는 p-layer에 기존의 p-a-Si:H를 사용함과 동시에 high Bandgap의 buffer layer를 p-layer와 i-layer 사이에 삽입함으로써 그 장점을 유지하고 높은 defect과 낮은 activation energy의 영향을 최소화하였다. ASA 시뮬레이션을 통해 a-Si:H보다 high Bandgap을 가지는 a-SiOx 박막을 사용하여 p-type buffer layer의 두께를 2nm, Bandgap 2.0eV, activation energy를 0.55eV로 설정하고, i-type buffer layer의 두께를 2nm, Bandgap 1.8eV로 설정하여 삽입하였을 때 박막 태양전지의 변환 효율 10.74%를 달성할 수 있었다. (Voc=904mV, Jsc=$17.48mA/cm^2$, FF=67.97).

  • PDF

Surface Hardness Measurement of Anodic Oxide Films on AA2024 based an Ink-Impregnation Method

  • Moon, Sungmo;Rha, Jong-joo
    • 한국표면공학회지
    • /
    • 제53권2호
    • /
    • pp.80-86
    • /
    • 2020
  • This paper is concerned with type of imperfections present within the anodic oxide films on AA2024 and surface hardness of the anodic film measured after ink-impregnation. The anodic oxide films were formed for 25 min at 40 mA/㎠ and 15±0.5℃ and 300 rpm of magnet stirring rate in 20% sulfuric acid solution. The ink-impregnation allows clear observations of not only the imperfections within the anodic oxide films but also an indentation mark on the oxide film surface made by a pyramidal-diamond penetrator for the hardness measurement. There were observed four different regions in the anodic oxide films on AA2024 and the surface hardness of the anodic oxide films appeared to be crucially dependent on the type of defects, showing 60~100 Hv on the oxide surface region I with large size black defect, 100~140 Hv on the oxide surface region II with large size grey defect, 140~170 Hv on the oxide surface region III with mall size black and/or grey defects and 170~190 Hv on the oxide surface region IV without defects. The pyramidal indentation marks were observed to be distorted in the regions with a large size black and grey defects, while no distortion of the indentation mark was observed in the regions with small size defects and without visible defects.

국부지역 이진 패턴 분석법에 기초한 단락 및 돌기형 FAB불량 검출기법 (A Method of Detecting Short and Protrusion-type FAB Defects Based on Local Binary Pattern Analysis)

  • 김진수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.1018-1020
    • /
    • 2013
  • PCB 제작 분야에서 TCP와 COF에서는 전기적인 특성검사만으로 자동화를 이루어지고 있으며, 실제 단락 및 돌기(근사단락) 형태의 데이터 불량 등에 대해서는 노동력을 동원해 불량을 검출하고 있는 실정이다. 본 논문에서는 영상처리에 의해 국부지역패턴 분석법에 기초한 검출기법을 제안한다. 제안한 방법은 히스토그램보정, 공간위치보정 및 최대왜곡좌표를 구하는 전처리 과정을 포함하여, 지역기반의 패턴분석법이 적용된다. 모의실험을 통하여 제안한 방식은 기존의 영역기반의 검출기법에 비해 성능이 개방 및 근사개방 결함 검출에서 크게 성능을 개선할 수 있음을 보인다.

  • PDF

완전분해 점검을 통한 장기운영 전투기 전기배선시스템의 신뢰성분석 (EWIS Reliability Analysis of Aging Fighter Aircraft through Teardown Inspection)

  • 이호용
    • 한국항공운항학회지
    • /
    • 제26권4호
    • /
    • pp.116-121
    • /
    • 2018
  • According to the incresement of aging aircraft, Republic of Korea Air Force (RoKAF) conducted a teardown inspection of aircraft's EWIS (electrical wiring interconnection system) to determine the status of deterioration and the influence of failure occurrences due to it. The inspected aircraft were the retired fighter jets that had been used for more than 40 years. By analyzing defect type and the defect tendency, RoKAF can establish the necessary measures for the usage extension of their fleet and furthermore, the analysis results can be used as a basic data for the preparation of it's aircraft aging. EWIS inspection was done throughout careful visual inspection technique by removing all the ducts and pipes located in the fuselage and wings. For the aircraft wiring where no damage was found, the elongation tests were performed to determine the deterioration of wiring according to the location of the aircraft. The connectors, which is the main cause of intermittent failure, were completely disassembled and inspected for internal damage such as corrosion, abrasion, and traces of foreign objects. The detected defects were classified into 4 severity levels based on the type of damage, and the classified defects were weighted according to the criticality which may affects to it's system to establish the action plan.

정보통신공사 하자관리 실태조사를 통한 세부 공종별 하자 유형 및 원인 분석 (Analyzing Defects Types and Causes of Activities in Information and Communication Works Based on Investigation)

  • 엄용빈;손성근;강상훈;박현정
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.269-270
    • /
    • 2021
  • As the era of the Fourth Industrial Revolution arrives and the culture of contact-less was established due to the long-term COVID-19, the construction industry is striving to develop smart home services to expand the scope of information and communications technology (ICT) to provide convenience to residents. However, various defects are occurring in information and communications technology facilities in apartments, and related research is lacking. In this study, case studies and research methods of related prior studies are analyzed as a basis for identifying the types and causes of defects that occur in information and communications technology facilities. To analyze various studies, we divided them into studies on smart home Internet of Things (IoT), information and communications technology construction of apartments, and investigated their features and limitations. Plus, future research will be conducted on apartments within 10 years of completion among apartments completed by domestic construction companies to supplement the limitations of prior research. In addition, we will prepare basic data on defects of ICT construction by analyzing the major causes of defect types through the analysis of defect types and frequency by detailed work type of information and communications technology construction.

  • PDF

Fallot 4징증의 근치수술에 대한 임상적 고찰 (A review of the total correction of tetralogy of Fallot)

  • 채성수
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.337-341
    • /
    • 1983
  • The experience with operative treatment for total correction of Tetralogy of Fallot at the department of Thoracic and Cardiovascular Surgery, Korea University Hospital from January, 1977, through April, 1983 was reviewed. Of the 29 patients reviewed, male to female occurrence ratio was 22:7 Type of V.S.D. was type II in 26 cases[90%] and total conus defect in 3 cases[10%]. Average size of V.S.D. was 19 mm. Type of Right ventricular outflow tract stenosis was highest frequency with pulmonary valvular and infundibular stenosis combined type in 21 cases[72%], and there were 8 deaths In this group. Type of R.V.O.T. reconstruction contains 2 cases of infundibulectomy only, 1 case of infundibulectomy with valvular commissurotomy, 2 cases of pericardial patch, 23 Cases of pericardial patch with Teflon or Dacron felt reinforced and 1 case of pulmonary valved conduit reconstruction. Operative mortality was higher in outflow patch through pulmonary valve ring. Overall mortality was 31%. Major causes of death and postoperative complications were low output syndrome, complete A-V block acute renal failure, ventricular fibrillation, bleeding brain abscess, and sudden cardiac arrest.

  • PDF