• 제목/요약/키워드: Defect type

검색결과 1,072건 처리시간 0.023초

부분 폐정맥 환류이상과 심방중격 결손증을 동반한 삼중방심의 치험 1례 (Cor Triatriatum Associated with Atrial Septal Defect and Partial Anomalous Pulmonary Venous Return: Report of A Case)

  • 이철주
    • Journal of Chest Surgery
    • /
    • 제18권3호
    • /
    • pp.440-445
    • /
    • 1985
  • Cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium, which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. Usually it is diagnosed after operation because difficulty in visualization of the diaphragm by conventional diagnostic tools. We experienced a rare entity of congenital heart disease diagnosed as car triatriatum with atrial septal defect and partial anomalous pulmonary venous return after completing operation, which was diagnosed as ASD with PAPVR preoperatively. Anomalous right pulmonary venous opening was located at right atrium, secundum type defect of atrial septum was present, and dual chambered left atrium without connection was also seen. Excision of the diaphragm and wide patch repair of ASD including right pulmonary vein were performed with good postoperative results. Herewith, we report this case with review of literatures.

  • PDF

자기누설탐상시스템에서 밀집된 다수의 결함에 의한 탐상 신호 왜곡에 관한 연구 (Study on the Distortion of Detecting Signals with the Multi-Defects in Magnetic Flux Leakage System)

  • 서강;김덕건;한재만;박관수
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.876-883
    • /
    • 2007
  • The magnetic flux leakage(MFL) type nondestructive testing(NDT) method is widely used to detect corrosion, defects and mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Hall sensors detect the leakage fields in the region of the defect. The defects are sometimes occurred in group. The accuracy of the detecting signals in this defect cluster become lowered because of the complexity of the defect cluster. In this paper, the effects of the multi -defects are analyzed. The detecting signals are computed by 3-dimensional finite element method and compared with real measurement. The results say that, rather than the size of the defects, the effects of the relative position of the multi-defects are very important on the detecting signals.

SS400용접 부위의 표면 피로균열거동에 관한 연구 (A study on surface fatigue crack behavior of SS400 welding Zone)

  • 이용복;조남익;박강은
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1995년도 특별강연 및 추계학술발표 개요집
    • /
    • pp.214-217
    • /
    • 1995
  • In order to investigate characteristics of surface fatigue crack propagation from a pit shaped surface defect which frequently exists near weld joints, SS400 steel with thickness of 12mm, which generally used for structure members, was submerged-arc welded with butt type and machined for both surface. The weld joints were devided into 5 regions, weld metal, boundary between heat affected zone (HAZ), HAZ, boundary between HAZ and base metal, and base metal. Specimens from each region were machined for a pit shaped initial surface defect with aspect ratio of 2. characteristics of surface fatigue crack por pagation from the defect under the same loading condition were compared and discussed.

  • PDF

총대정맥-폐동맥 단락술 수술치험 2례 (Total Cavo Pulmonary Shunt: Report of two cases)

  • 박철현;이신영;김창호
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1263-1269
    • /
    • 1990
  • Two patients with uncorrectable cyanotic cardiac anomalies underwent total cavopulmonary shunt[modified Fontan operation]. Case I was a 14 years old male with dyspnea and cyanosis after birth. Aortogram showed TGA combined with overriding of aorta, pulmonary stenosis, complete atrioventricular septal defect, interruption of inferior vena cava, and situs inversus totalis. We had performed total cavopulmonary shunt using with 16 mm Gortex Graft in single atrium to bypass the hepatic vein to pulmonary artery. Postoperatively, patient sustained low PaCO2 and low cardiac output and then expired at 19th postoperative day. The cause of death of the patient would be low cardiac output. Case II was a 6 years old female with dyspnea and cyanosis after birth. Aortogram showed tricuspid atresia[Type IIb], transposition of great arteries, atrial septal defect, ventricular septal defect and pulmonary stenosis, We had performed total cavo-pulmonary shunt using intraatrial baffle[tunnel] with Goretex patch. The postoperative course of this patient was good without event.

  • PDF

Reconstruction of partial maxillectomy defect with a buccal fat pad flap and application of 4-hexylresorcinol: a case report

  • Seok, Hyun;Kim, Min-Keun;Kim, Seong-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.370-374
    • /
    • 2016
  • Mucoepidermoid carcinoma (MEC) is the most common type of malignant neoplasm in the minor salivary gland. The hard palate is a frequently involved site of MEC. The treatment of low-grade MEC on the hard palate is wide local resection with a tumor-free margin. In the present case, the maxillary defect was reconstructed using a buccal fat pad (BFP) flap, followed by application of 4-hexylresorcinol (4HR) ointment for 2 weeks. The grafted BFP successfully covered the tumor resection defect without tension and demonstrated complete re-epithelialization without any complications.

Optimum Design of a Non-Destructive Testing System to Maximize Magnetic Flux Leakage

  • Park, G.S;Jang, P.W;Rho, Y.W
    • Journal of Magnetics
    • /
    • 제6권1호
    • /
    • pp.31-35
    • /
    • 2001
  • This paper describes the design method of a magnetic system to maximize the magnetic flux leakage (MFL) in a non-destructive testing (NDT) system. The defect signals in a MFL type NDT system mainly depend on the change of the magnetic leakage flux in the region of a defect. The characteristics of the B-H curves are analysed and a design method to define the operating point on B-H curves for maximum leakage is performed. The computed MFL signal by a nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG, the traveling detector unit in gas pipe, in an 8 inch test tube with defects. The rhombic defects could be successfully identified from the defect signals.

  • PDF

A Method to Simulate Frictional Heating at Defects in Ultrasonic Infrared Thermography

  • Choi, Wonjae;Choi, Manyong;Park, Jeonghak
    • 비파괴검사학회지
    • /
    • 제35권6호
    • /
    • pp.407-413
    • /
    • 2015
  • Ultrasonic infrared thermography is an active thermography methods. In this method, mechanical energy is introduced to a structure, it is converted into heat energy at the defects, and an infrared camera detects the heat for inspection. The heat generation mechanisms are dependent on many factors such as structure characteristics, defect type, excitation method and contact condition, which make it difficult to predict heat distribution in ultrasonic infrared thermography. In this paper, a method to simulate frictional heating, known to be one of the main heat generation mechanisms at the closed defects in metal structures, is proposed for ultrasonic infrared thermography. This method uses linear vibration analysis results without considering the contact boundary condition at the defect so that it is intuitive and simple to implement. Its advantages and disadvantages are also discussed. The simulation results show good agreement with the modal analysis and experiment result.

A Study on the Partial Discharge Patterns from Multi-Defect Insulating Systems

  • Lee, June-Ho;Tatsuki Okamoto
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.170-173
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produced from these defects simultaneously. Regarding these situations, we have to discriminate the type of defect as well as determine whether the PD occurs or not. In this paper, some analysis results of the PD signals from multi-defects insulating system were presented. We measure the PD signals by using three kind of electrode system, IEC(b), Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combined to electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods were tried, and the possibilities and limitations of each method were clarified.

  • PDF

Application of Multichannel Quantum Defect Theory to the Triatomic van der Waals Predissociation Process II

  • 이천우
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권10호
    • /
    • pp.957-968
    • /
    • 1995
  • Generalized Multichannel Quantum Defect theory (MQDT) was implemented to the vibrational predissociation of triatomic van der Waals molecules in the previous paper [Bull. Korean Chem. Soc, 12, 228 (1991)]. Implementation was limited to the calculation of the scattering matrix. It is now extended to the calculation of the predissociation spectra and the final rotational distribution of the photofragment. The comparison of the results with those obtained by other methods, such as Golden-rule type calculation, infinite order sudden approximation (IOS), and close-coupling method, shows that the implementation is successful despite the fact that transition dipole moments show more energy dependence than other quantum defect parameters. Examination of the short-range channel basis functions shows that they resemble angle-like functions and provide the validity of the IOS approximation. Besides the validity of the latter, only a few angles are found to play the major role in photodissociation. In addition to the implementation of MQDT, more progress in MQDT itself is made and reported here.

Optimum Design of the Non-Destructive Testing System to Maximize the Magnetic Flux Leakages

  • Park, G. S.;P. W. Jang;Park, Y. W.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2000년도 International Symposium on Magnetics The 2000 Fall Conference
    • /
    • pp.539-545
    • /
    • 2000
  • This paper describes the design method of the magnetic system to maximize the magnetic flux leakage (MFL) in non-destructive testing (NDT) system. The defect signals in MFL type NDT system mainly depends on the change of the magnetic leakage flux in the region of defect. The characteristics of the B-H curves are analyzed and the design method to define the operating point in B-H curves for the maximum leakage is performed. The computed MFL signal by nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG in the 8 inches test tube with defects. The rhombic defects could be successfully composed from the defect signals.

  • PDF