• Title/Summary/Keyword: Defect ratio

Search Result 464, Processing Time 0.022 seconds

Study on Improvement of Signal to Background Ratio of Laser-based Fluorescence Imaging System (레이저 기반 형광 영상 시스템의 Signal to Background Ratio 향상 연구)

  • Kim, J.H.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.107-111
    • /
    • 2020
  • Recently, as an aging society progresses, a lot of interest in health and diagnosis is increasing, As the field of various bio-imaging systems for guided surgery capable of accurate diagnosis has emerged as important, a Fluorescence imaging system capable of accurate measurement and real-time confirmation has emerged as an important field. Fluorescence images currently being used are mainly in the NIR-I band, but many studies are in progress in the NIR-II band in order to improve resolution and confirm fluorescence deeply and accurately. In this paper, the difference between NIR-I and NIR-II, optical characteristics, and SBR (signal to background ration) of a fluorescent imaging system, was investigated using the finite element (FEM) method. After confirming, it was confirmed that the SBR was 16.2 times higher in the NIR-II area than in the NIR-I by making the skin phantom and measuring the fluorescence. It is confirmed that the enhancement in SBR of the Fluorescence imaging system is more effective in the NIR-II region than in the NIR-I region and expected to be used in application fields such as guided surgery, bio-sensor and also device which can detect the defect of optical devices.

A Study on the Calculation of Load Resistance Factor of over Tension Anchors by Optimization Design (최적화 설계를 통한 과긴장 앵커의 하중-저항계수 산정 연구)

  • Soung-Kyu Lee;Yeong-Jin Lee;Yong-Jae Song;Tae-Jun Cho;Kang-Il Lee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.17-26
    • /
    • 2023
  • To consider the risk of damage and fracture of P.C strands, the existing post-maintenance system alone has the limitations, hence it is necessary to quantitatively evaluate and predict the deterioration, durability and safety of facilities and establish a reasonable maintenance system considering the asset value of facilities. Therefore, it is worth considering a preventive maintenance plan that allows proactive measures to be taken before a major defect occurs in the temporary anchor. This study devised a preventive over tension method, reviewed its effectiveness through design and field tests, by calculating the resistance factors by performing a reliability-based optimization design. At this time, the over tension anchor method was evaluated using the ratio of the residual tension force after the fracture of P.C strands to the effective tension force before the fracture of P.C strand, followed by the resistance factor calculated by the optimal solution for each random variables using Excel solver and applying it to the limit state equations. As a result of the study, if the over tension ratio is 125% to 130%, the remaining strands showed a high resistance effect even after the fracture of P.C strand. As a result of the optimization design, it was found that it is appropriate to apply the load factor (γ) of 1.25, and the resistance factors of Φ1, Φ2, Φ3 as 0.7, 0.5, 0.6.

Studies on the Kiln Drying Characteristics of Several Commercial Woods of Korea (국산 유용 수종재의 인공건조 특성에 관한 연구)

  • Chung, Byung-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.8-12
    • /
    • 1974
  • 1. If one unity is given to the prongs whose ends touch each other for estimating the internal stresses occuring in it, the internal stresses which are developed in the open prongs can be evaluated by the ratio to the unity. In accordance with the above statement, an equation was derived as follows. For employing this equation, the prongs should be made as shown in Fig. I, and be measured A and B' as indicated in Fig. l. A more precise value will result as the angle (J becomes smaller. $CH=\frac{(A-B') (4W+A) (4W-A)}{2A[(2W+(A-B')][2W-(A-B')]}{\times}100%$ where A is thickness of the prong, B' is the distance between the two prongs shown in Fig. 1 and CH is the value of internal stress expressed by percentage. It precision is not required, the equation can be simplified as follows. $CH=\frac{A-B'}{A}{\times}200%$ 2. Under scheduled drying condition III the kiln, when the weight of a sample board is constant, the moisture content of the shell of a sample board in the case of a normal casehardening is lower than that of the equilibrium moisture content which is indicated by the Forest Products Laboratory, U. S. Department of Agriculture. This result is usually true, especially in a thin sample board. A thick unseasoned or reverse casehardened sample does not follow in the above statement. 3. The results in the comparison of drying rate with five different kinds of wood given in Table 1 show that the these drying rates, i.e., the quantity of water evaporated from the surface area of I centimeter square per hour, are graded by the order of their magnitude as follows. (1) Ginkgo biloba Linne (2) Diospyros Kaki Thumberg. (3) Pinus densiflora Sieb. et Zucc. (4) Larix kaempheri Sargent (5) Castanea crenata Sieb. et Zucc. It is shown, for example, that at the moisture content of 20 percent the highest value revealed by the Ginkgo biloba is in the order of 3.8 times as great as that for Castanea crenata Sieb. & Zucc. which has the lowest value. Especially below the moisture content of 26 percent, the drying rate, i.e., the function of moisture content in percentage, is represented by the linear equation. All of these linear equations are highly significant in testing the confficient of X i. e., moisture content in percentage. In the Table 2, the symbols are expressed as follows; Y is the quantity of water evaporated from the surface area of 1 centimeter square per hour, and X is the moisture content of the percentage. The drying rate is plotted against the moisture content of the percentage as in Fig. 2. 4. One hundred times the ratio(P%) of the number of samples occuring in the CH 4 class (from 76 to 100% of CH ratio) within the total number of saplmes tested to those of the total which underlie the given SR ratio is measured in Table 3. (The 9% indicated above is assumed as the danger probability in percentage). In summarizing above results, the conclusion is in Table 4. NOTE: In Table 4, the column numbers such as 1. 2 and 3 imply as follows, respectively. 1) The minimum SR ratio which does not reveal the CH 4, class is indicated as in the column 1. 2) The extent of SR ratio which is confined in the safety allowance of 30 percent is shown in the column 2. 3) The lowest limitation of SR ratio which gives the most danger probability of 100 percent is shown in column 3. In analyzing above results, it is clear that chestnut and larch easly form internal stress in comparison with persimmon and pine. However, in considering the fact that the revers, casehardening occured in fir and ginkgo, under the same drying condition with the others, it is deduced that fir and ginkgo form normal casehardening with difficulty in comparison with the other species tested. 5. All kinds of drying defects except casehardening are developed when the internal stresses are in excess of the ultimate strength of material in the case of long-lime loading. Under the drying condition at temperature of $170^{\circ}F$ and the lower humidity. the drying defects are not so severe. However, under the same conditions at $200^{\circ}F$, the lower humidity and not end coated, all sample boards develop severe drying defects. Especially the chestnut was very prone to form the drying defects such as casehardening and splitting.

  • PDF

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.

Brazing characteristics of $ZrO_2$ and Ti-6Al-4V brazed joints with increasing temperature (브레이징 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성)

  • Kee, Se-Ho;Park, Sang-Yoon;Heo, Young-Ku;Jung, Jae-Pil;Kim, Won-Joong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.169-175
    • /
    • 2012
  • Purpose: In this study, brazing characteristics of $ZrO_2$ and Ti-6Al-4V brazed joints with increasing temperature were investigated. Materials and methods: The sample size of the $ZrO_2$ was $3mm{\times}3mm{\times}3mm$ (thickness), and Ti-6Al-4V was $10mm(diameter){\times}5mm(thickness)$. The filler metal consisted of Ag-Cu-Sn-Ti was prepared in powder form. The brazing sample was heated in a vacuum furnace under $5{\times}10^{-6}$ torr atmosphere, while the brazing temperature was changed from 700 to $800^{\circ}C$ for 30 min. Results: The experimental results shows that brazed joint of $ZrO_2$ and Ti-6Al-4V occurred at $700-800^{\circ}C$. Brazed joint consisted of Ag-rich matrix and Cu-rich phase. A Cu-Ti intermetallic compounds and a Ti-Sn-Cu-Ag alloy were produced along the Ti-6Al-4V bonded interface. Thickness of the reacted layer along the Ti-6Al-4V bonded interface was increased with brazing temperature. Defect ratios of $ZrO_2$ and Ti-6Al-4V bonded interfaces decreased with brazing temperature. Conclusion: Thickness and defect ratio of brazed joints were decreased with increasing temperature. Zirconia was not wetting with filler metal, because the reaction between $ZrO_2$ and Ti did not occur enough.

Prenatally Diagnosed Uncommon Mosaic Autosomal Trisomy

  • Lee, Bom-Yi;Park, So-Yeon;Lee, Moon-Hee;Kim, Jin-Woo;Park, Ju-Yeon;Choi, Eun-Young;Lee, Yeon-Woo;Oh, Ah-Rum;Lee, Shin-Young;Kim, Min-Hyung;Ryu, Hyun-Mee
    • Journal of Genetic Medicine
    • /
    • v.6 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • Prenatal diagnosis of rare autosome mosaicism involvingchromosomes other than chromosome 13, 18, 21 or the sex chromosome is encountered prognostic dilemma during genetic counseling. We report four cases of level III uncommon mosaicism of trisomy 5, 16 and 20,diagnosed prenatally. In case 1 with mosaic trisomy 20, there was a higher mosaic ratio of trisomy 20 in the repeat amniocentesis (62.1%) than in the first (36.6%) with normal fetal ultrasound finding except for a relatively small aorta on a 3-vessel view of the fetal heart. Case 2 showed a low rate of mosaic trisomy 20 (5.25%) in cultured amniocytes but normal karyotype in the repeat amniocentesis, who delivered a normal healthy baby. Case 3 showed a 13.6% of trisomy 16 mosaicism in the 30 cells of cultured amniocytes. Sixty cells from a fetal blood sample at termination showed non-mosaic 46,XX normal karyotype, while skin fibroblasts had 22.5% trisomy 16 in 40 metaphases. The autopsy showed ventricular septal defect (VSD). Case 4 with low grade mosaicism (10.5%) of trisomy 5 resulted in elective termination, though the ultrasoumd showed growsly normal fetus. Although level III mosaicism is regarded as true mosaicism, it is difficult to predict the outcome of the fetus with rare mosaic autosome trisomy. Therefore mosaic autosome trisomy of fetus should be carefully interpreted with more various approaches including repeat sampling and targeted fetal ultrasound.

  • PDF

Clinical Experiences of Cardiac Surgery Using Minimal Incision (소절개선을 이용한 심장수술의 임상고찰)

  • Kim, Kwang-Ho;Kim, Joung-Taek;Lee, Seo-Won;Kim, Hae-Sook;Lim, Hyun-Kung;Lee, Choon-Soo;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.373-378
    • /
    • 1999
  • Background: Minimally invasive technique for various cardiac surgeries has become widely accepted since it has been proven to have distinct advantages for the patients. We describe here the results of our experiences of minimal incision in cardiac surgery. Material and Method: From February 1997 to November 1998, we successfully performed 31 cases of minimally invasive cardiac surgery. Male and female ratio was 17:14, and the patients age ranged from 1 to 75 years. A left parasternal incision was used in 9 patients with single vessel coronary heart disease. A direct coronary bypass grafting was done under the condition of the beating heart without cardiopulmonary bypass support(MIDCAB). Among these, one was a case of a reoperation 1 week after the first operation due to a kinked mammary artery graft. A right parasternal incision was used in one case of a redo mitral valve replacement. Mini-sternotomy was used in the remaining 21 patients. The procedures were mitral valve replacement and tricuspid annuloplasty in 6 patients, mitral valve replacement 5, double valve replacement 2, aortic valve replacement 1, removal of left atrial myxoma 1, closure of atrial septal defect 2, repair of ventricular septal defect 2, and primary closure of r ght ventricular stab wound 1. The initial 5 cases underwent a T-shaped mini-sternotomy, however, we adopted an arrow-shaped ministernotomy in the remaining cases because it provided better exposure of the aortic root and stability of the sternum after a sternal wiring. Result: The operation time, the cardiopulmonary bypass time, the aorta cross-clamping time, the mechanical ventilation time, the amount of chest tube drainage until POD#1, the chest tube indwelling time, and the duration of intensive care unit staying were in an acceptable range. There were two surgical mortalities. One was due to a rupture of the aorta cannulation site after double valve replacement on POD#1 in the mini-sternotomy case, and the other was due to a sudden ventricular arrhythmia after MIDCAB on POD#2 in the parasternal incision case. Postoperative complications were observed in 2 cases in which a cerebral embolism developed on POD#2 after a mini-sternotomy in mitral valve replacement and wound hematoma developed after a right parasternal incision in a single coronary bypass grafting. Neither mortality nor complication was directly related to the incision technique itself. Conclusion: Minimally invasive surgery using parasternal or mini-sternotomy incision can be used in cardiac surgeries since it is as safe as the standard full sternotomy incisions.

  • PDF

Evaluation of Result of Coronary Artery Bypass Graft Surgery by Using Pre and Postoperative Myocardial SPECT (관동맥우회술 전후의 심근 SPECT를 이용한 수술 결과의 평가)

  • 이장훈;한승세
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1083-1091
    • /
    • 1997
  • This study was purposed to assess the result of coronary artery bypass graft surgery by analyzing and comparing the pre and postoperative myocardial perfusion state quantitatively by using myocardial SPECT. Twenty patients who received coronary artery bypass graft surgery since 1993 underwent both preoperative and postoperative myocardial SPECT and the result were analyzed. The mean age was 56.4$\pm$9.0 years, and the patients were composed of thirteen males and seven females. For quantitative analysis, we used polar maps of SPECT generated by Cedars-Sin i Medical Center program and we calculated perfusion scores, ischemic myocardial area ratios and reperfusion scores from polar maps. Preoperative mean stressfrest perfusion score was 7.3$\pm$ 1.117.7$\pm$ 1.0 and postoperative score was 8.1 $\pm$ 1 118.3$\pm$ 1.1. Preoperative mean stress ischemic myocardial area ratio was 0.32$\pm$0.2 and postoperative ratio was 0.15 $\pm$0.1. Postoperative mean perfusion score was significantly increased but, on the other hand, mean ischemic myocardial area ratio was significantly decreased as compared with preoperative values(p<0.01). Preoperative mean perfusion score of patients with postoperative roper(usion score more than 1.5 was significantly higher(p<0.01) than that of patients with postoperative reperfusion score less than 1.5. Preoperative perfusion scores of coronary artery territories that had fixed perfusion defect at myocardial SPECT were significantly low(4.3 $\pm$0.514.6$\pm$0.6, stresslrest), nevertheless it proved quantitatively that there was improvement in myocardial perfusion after surgery by showing improved perfusion scores postoperatively. In conclusion, myocardial SPECT is useful method for quantitative analysis of the myocardial perfusion state after coronary artery bypass grafting surgery.

  • PDF

Investigation of Fatigue Strength and Prediction of Remaining Life in the Butt Welds Containing Penetration Defects (블완전용입 맞대기 용접재의 용입깊이에 따른 피로강도특성 및 잔류수명의 산출)

  • Han, Seung Ho;Han, Jeong Woo;Shin, Byung Chun
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.423-435
    • /
    • 1998
  • In this paper fatigue strength reduction of butt weld with penetration defect, which can be seen frequently in the steel bridge, was assessed quantitatively. S-N curves were derived and investigated through the constant amplitude fatigue test of fully or partially penetrated welded specimen made of SWS490 steel. The fracture mechanical method was applied in order to calculate the remaining fatigue life of the partially penetrated butt welds. The fatigue limit of the fully penetrated butt welds was higher than that of category A in AASHTO's fatigue design curves, and the slope of S-N curves with 5.57 was stiffer than that of other result for welded part generally accepted as 3. The fatigue strength of the partially Penetrated butt weld was strongly influenced by the size of lack of penetration, D. It decreased drastically with increasing D from 3.9 to 14.7mm. Fracture behaviour of the partially penetrated butt weld is able to be explained obviously from the beach mark test that a semi-elliptical surface crack with small a/c ratio initiates at a internal weld root and propagates through the weld metal. To estimate the fatigue life of the partially penetrated butt weld with fracture mechanics, stress intensity factors K of 3-dimensional semi-elliptical crack were calculated by appling finite elements method and fracture mechanics parameters such as C and m were derived through the fatigue test of CT-specimen. As a result, the fatigue lives obtained by using the fracture mechanical method agreed well with the experimental results. The results were applied to Sung-Su bridge collapsed due to penetration defects in butt weld of vertical member.

  • PDF

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF