• Title/Summary/Keyword: Defect ratio

Search Result 464, Processing Time 0.034 seconds

Effect of Surgical Closure of Ventricular Septal Defect on Ventricular Systolic Time Intervals (심실중격결손 교정술 전후의 심실 수축기 시간 간격 (Ventricular Systolic Time Interval)의 변화)

  • 이현경;이영환;이장훈;김도형;백종현;이동협;이정철;한승세;정태은
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.511-516
    • /
    • 2002
  • Background: This study was undertaken in infant patients with isolated ventricular septal defect(VSD) to determine the effect of surgical closure on ventricular systolic time interval, as a parameter for ventricular performance, by echocardiography. Material and Method: Thirty patients were enrolled. Mean age of patients at operation was 6.5$\pm$3.2 months and all patients had non-restrictive VSD. We checked the left atrium/aorta(LA/Ao) ratio, left ventricle ejection fraction(EF), left ventricular systolic time interval(LVSTI), and right ventricular systolic time interval(RVSTI). Echocardiographic studies were done before surgical correction and postoperative periods(postopl: within 2 weeks, postop2: between 4 and 6 months, postop3: between 1 and 2 years). Result: LA/Ao ratio decreased significantly at immediate postoperative period compared to preoperative period and sustained during further follow-up period(from 1.74$\pm$0.37 to 1.36$\pm$0.24*, 1.32$\pm$0.22*, and 1.27$\pm$0.19*, p<0.01). LV EF had not changed during follow-up periods(from 65.1$\pm$7.0 to 62.3$\pm$9.5, 62.8$\pm$5.7, and 64.1$\pm$6.9). LVSTI decreased significantly at postop2 and sustained during further follow-up period (from 0.46$\pm$0.13 to 0.46$\pm$0.11, 0.37$\pm$0.08*, and 0.34$\pm$0.07*, p<0.01). RVSTI decreased significantly at postop3(0.33$\pm$0.08 to 0.32$\pm$0.08, 0.31$\pm$0.07, and 0.27$\pm$0.05*, p<0.01). Conclusion: We found that right and left ventricular systolic time intervals had decreased over the period of 1 year after surgical correction of VSD. Therefore, it is necessary to observe the change of ventricular function during that period.

Sintering and Electrical Properties According to Sb/Bi Ratio(I) : ZnO-Bi2O3-Sb2O3-Mn3O4-Cr2O3 Varistor (Sb/Bi비에 따른 5원계 바리스터의 소결거동 및 전기적 특성(I) : ZnO-Bi2O3-Sb2O3-Mn3O4-Cr2O3)

  • Hong, Youn-Woo;Lee, Young-Jin;Kim, Sei-Ki;Kim, Jin-Ho
    • Korean Journal of Materials Research
    • /
    • v.22 no.12
    • /
    • pp.675-681
    • /
    • 2012
  • We aimed to examine the co-doping effects of 1/6 mol% $Mn_3O_4$ and 1/4 mol% $Cr_2O_3$ (Mn:Cr = 1:1) on the reaction, microstructure, and electrical properties, such as the bulk defects and grain boundary properties, of ZnO-$Bi_2O_3-Sb_2O_3$ (ZBS; Sb/Bi = 0.5, 1.0, and 2.0) varistors. The sintering and electrical properties of Mn,Cr-doped ZBS, ZBS(MnCr) varistors were controlled using the Sb/Bi ratio. Pyrochlore ($Zn_2Bi_3Sb_3O_{14}$), ${\alpha}$-spinel ($Zn_7Sb_2O_{12}$), and ${\delta}-Bi_2O_3$ (also ${\beta}-Bi_2O_3$ at Sb/Bi ${\leq}$ 1.0) were detected for all of the systems. Mn and Cr are involved in the development of each phase. Pyrochlore was decomposed and promoted densification at lower temperature on heating in Sb/Bi = 1.0 system by Mn rather than Cr doping. A more homogeneous microstructure was obtained in all systems affected by ${\alpha}$-spinel. In ZBS(MnCr), the varistor characteristics were improved dramatically (non-linear coefficient, ${\alpha}$ = 40~78), and seemed to form ${V_o}^{\cdot}$(0.33 eV) as a dominant defect. From impedance and modulus spectroscopy, the grain boundaries can be seen to have divided into two types, i.e. one is tentatively assigned to ZnO/$Bi_2O_3$ (Mn,Cr)/ZnO (0.64~1.1 eV) and the other is assigned to the ZnO/ZnO (1.0~1.3 eV) homojunction.

A Light and Scanning Electron Microscopic Study on the Implant of Tooth Ash-Porcelain Mixture (치아회분(齒牙灰粉)과 도재(陶材) 복합(複合) 매식체(埋植體)에 관(關)한 광학현미경(光學顯微鏡) 급(及) 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Cho, Young-Hak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.33-50
    • /
    • 1984
  • The purpose of this study was to investigate whether the ashed tooth powder is utilized as an alternative material of the implant to recovery the bony defect. For this purpose its biocompatibility was evaluated comparing to the synthetic calcium phosphate compounds, such as Syntograft and Calcitite, as well as the vacuum firing porcelain (Ceramco Inc.) which is anticipated to use as a matrix to aid sintering. Bony defects to exposure the bone marrow, $3{\times}5$ mm in size, were created in the right and left tibias of fifteen rabbits, and then the ashed tooth powder at $950^{\circ}C$, the porcelain powder, Syhtograft and Calcitite were inserted in the defects of twelve rabbits of the experimental group and the blood clot only was filled in the defects of three rabbits of the control group. The experimental and control rabbits were sacrificed at 1st, 2nd 3rd week after implantation and the histologic examination was performed. The ashed tooth powder in order to make the needed form of the implant was molded using the cylindrical mold 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$ and the ashed tooth powder was sintered at $1100^{\circ}C$ for 1 hour and the mixture of the porcelain powder and the ashed tooth powder at the weight ratio of 7:3, 6:4, 5:5, 4:6 were molded in the same manner and were sintered at $925^{\circ}C$. From this sintered material, square shaped implants were prepared in the dimension of $2{\times}4{\times}6mm$. The prepared implants were surgically placed in the subperiosteum of lateral surfaces of the right and left mandibular bodies. The dogs were sacrificed at 4 weeks, and then the specimens were examined using the light and scanning electron microscopes. The results of this study were obtained as follows: 1. Any inflammatory response was not noted after implanting of the ashed tooth powder, Syntograft, Calcitite and the porcelain powder during the whole experimental period after implantation. 2. Induction of the new bone formation was significantly shown in the ashed tooth powder, Syntograft and Calcitite. 3. The more the porcelain powder was contained in the implants, the more the porosity was and the bigger the pore size was under the scanning electron microscope. And there was ingrowing of the fibrous connective and the osteoid tissue. 4. The osteoid tissues were found to be directly fused to the implant of the ashed tooth powder, and the mixture implant of the porcelain powder and the ashed tooth powder at the weight ratio of 4:6 under the light and scanning electron microscopes.

  • PDF

Evaluation of Weld Defects in Stainless Steel 316L Pipe Using Guided Wave (스테인레스 316L강의 배관용접결함에 대한 유도초음파 특성 평가)

  • Lee, Jin-Kyung;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.46-51
    • /
    • 2015
  • Stainless steel is a popular structural materials for liquid-hydrogen storage containers and piping components for transporting high-temperature fluids because of its superior material properties such as high strength and high corrosion resistance at elevated temperatures. In general, tungsten inert gas (TIG) arc welding is used for bonding stainless steel. However, it is often reported that the thermal fatigue cracks or initial defects in stainless steel after welding decreases the reliability of the material. The objective of this paper is to clarify the characteristics of ultrasonic guided wave propagation in relation to a change in the initial crack length in the welding zone of stainless steel. For this purpose, three specimens with different artificial defects of 5 mm, 10 mm, and 20 mm in stainless steel welds were prepared. By considering the thickness of s stainless steel pipe, special attention was given to both the L(0,1) mode and L(0,2) mode in this study. It was clearly found that the L(0,2) mode was more sensitive to defects than the L(0,1) mode. Based on the results of the L(0,1) and L(0,2) mode analyses, the magnitude ratio of the two modes was more effective than studying each mode when evaluating defects near the welded zone of stainless steel because of its linear relationship with the length of the artificial defect.

A study on experiment from the Stair Joints Constructed with PC system part of it using the HI-FORM DECK (HI-FORM DECK를 이용한 부분 PC 계단 접합부의 접합방식에 따른 실험적 연구)

  • Chang, Kug-Kwan;Lee, Eun-Jin;Jin, Byung-Chang;Kang, Woo-Joo;Han, Tae-Kyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.9-12
    • /
    • 2008
  • The semi-rigid joint is the shape of middle that can supplement the defect of pin joints and accept the good point of rigid joints. Recently, a study on the pin joints is activated in the country, but because the study on semi-rigid joints is not many, this study tried to prove with producing test model of three shape. The test models are rigid joint HI-R, semi-rigid joint HI-S, pin joint HI-P. As a result of the test, respectively HI-R, HI-S, HI-P appeared shear failure of joint, flexure failure of the top fixing, flexure failure of the lower part slipping stair slab, and the maximum strength is measured to 51.74, 51.4, 24.63kN, the stiffness is appeared 1.58, 1.19, 0.37 respectively, The yield strength is respectively kept 44.5, 47.3, 24kN, and ductility ratio is appeared to 3.31, 2.32, 1.54, when is based on KBC code, sag of the acting service load is appeared that HI-P model is over the standard. When is based on distribution of bars strain ratio, HI-S seems similar behavior incipiently, but after the yield, the semi-rigid joint was able to be judged better than pin joint because of the stress allotment of joint internal elements.

  • PDF

Prospective Study on the Development of Glaucoma after Interferon alfa Therapy for Chronic Hepatitis B (만성 B형 간염 환자에서 인터페론 치료 후 녹내장 발생 여부의 전향적 연구)

  • Kwon, Young-Se;Choe, Yon-Ho;Hong, Sung-Bum
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.2
    • /
    • pp.169-174
    • /
    • 2000
  • Purpose: Previously reported ocular complications of interferon alfa administration are extremely rare. We experienced a 15-year-old boy with chronic hepatitis B who developed glaucoma after interferon alfa therapy. The purpose of this prospective study was to evaluate the possible development of glaucoma after interferon alfa therapy for chronic hepatitis B. Methods: Nine patients with chronic hepatitis B who visited Inha university hospital between February 1998 and July 1999 received interferon alfa therapy. We measured visual acuity, intraocular pressure, C/D ratio, and visual field examination at pre-interferon therapy, three and six months after therapy, respectively. Results: The total number of patients was 9 (4 boys and 5 girls). Mean age was $11.7{\pm}4.1$ years. The duration of therapy was 6 months and mean dosage of interferon was 5 million units. Compared with visual acuity, intraocular pressure, and C/D ratio at pre-therapy, those parameters at 3 months and 6 months after therapy showed no significant differences and none showed visual field defect after therapy. Conclusion: Our prospective study showed no evidence of development of glaucoma after interferon therapy. However, it is necessary to be concerned about the possibility of developing glaucoma or other ophthalmologic diseases after interferon therapy in chronic hepatitis B.

  • PDF

Effect on bone formation of the autogenous tooth graft in the treatment of peri-implant vertical bone defects in the minipigs

  • Kim, Seok Kon;Kim, Sae Woong;Kim, Kyung Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.2.1-2.9
    • /
    • 2015
  • Background: The aim of this study was to evaluate the effect of autogenous tooth bone as a graft material for regeneration of bone in vertical bony defects of the minipigs. Material and Methods: Six minipigs were used in this study. Four molars were extracted in the right mandibular dentition and sent to the Korea Tooth Bank for fabrication of autogenous tooth bone. Ten days later, each extraction site was implanted with MS Implant Narrow Ridge $3.0{\times}10mm$ fixture (Osstem, Seoul, Korea) after standardized 2mm-sized artificial vertical bony defect formation. Pineappleshaped Root-On type autogenous tooth bones were applied to the vertical defects around the neck area of the posterior three fixtures and the fore-most one was not applied with autogenous bone as a control group. Each minipig was sacrificed at 4, 8, 12 weeks after fixture installation and examined radiologically and histologically. Histological evaluation was done under light microscope with Villanueva osteochrome bone staining with semi-quantitative histomorphometric study. Percentage of new bone over total area (NBF) and bone to implant contact (BIC) ratio were evaluated using digital software for area calculation. Result: NBF were $48.15{\pm}18.02%$, $45.50{\pm}28.37%$, and $77.13{\pm}15.30%$ in 4, 8, and 12 weeks, respectively for experimental groups. The control group showed $37.00{\pm}11.53%$, $32.25{\pm}26.99%$, and $1.33{\pm}2.31%$ in 4,8,12 weeks, respectively. BIC ratio were $53.08{\pm}19.82%$, $45.00{\pm}28.37%$, and $75.13{\pm}16.55%$ in 4,8,12 weeks, respectively. Those for the control groups were $38.33{\pm}6.43%$, $33.50{\pm}29.51%$, and $1.33{\pm}2.31%$ in 4, 8, 12 weeks, respectively. Conclusion: Autogenous tooth bone showed higher score than control group in NBF and BIC in all the data encompassing 4,8,12 weeks specimens, but statistically significant only 12 weeks data in both NBF and BIC.

Estimation of the Reliability of Water Distribution Systems using HSPDA Model and ADF Index (HSPDA 모형 및 ADF index를 이용한 상수관망의 신뢰도 산정)

  • Baek, Chun-Woo;Jun, Hwan-Don;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.201-210
    • /
    • 2010
  • In this study, new methodology to estimate the reliability of a water distribution system using HSPDA model is suggested. In general, the reliability of a water distribution system can be determined by estimating either the ratio of the required demand to the available demand or the ratio of the number of nodes with sufficient pressure head to the number of nodes with insufficient pressure head when the abnormal operating condition occurs. To perform this approach, hydraulic analysis under the abnormal operating condition is essential. However, if the Demand-Driven Analysis (DDA) which is dependant on the assumption that the required demand at a demand node is always satisfied regardless of actual nodal pressure head is used to estimate the reliability of a water distribution system, the reliability may be underestimated due to the defect of the DDA. Therefore, it is necessary to apply the Pressure-Driven Analysis (PDA) having a different assumption to the DDA's which is that available nodal demand is proportion to nodal pressure head. However, because previous study used a semi-PDA model and the PDA model which had limited applicability depending on the characteristics of a network, proper estimation of the reliability of a water distribution system was impossible. Thus, in this study, a new methodology is suggested by using HSPDA model which can overcome weak points of existing PDA model and Available Demand Fraction (ADF) index to estimate the reliability. The HSPDA can simulate the hydraulic condition of a water distribution system under abnormal operating condition and based on the hydraulic condition simulated, ADF index at each node is calculated to quantify the reliability of a water distribution system. The suggested model is applied to sample networks and the results are compared with those of existing method to demonstrate its applicability.

Analysis on PD Pulse Distribution by Defects Depending on SF6 Pressure (SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석)

  • Kim, Sun-Jae;Jo, Hyang-Eun;Jeong, Gi-Woo;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2015
  • Electrode systems: a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack in epoxy plate and a free particle (FP) were fabricated to simulate insulation defects in a gas insulated switchgear (GIS). $SF_6$ gas was filled in the electrode systems by 3 bar and/or 5 bar, respectively. Partial discharge (PD) pulses were detected through a $50{\Omega}$ non-inductive resistor. A calibration test was carried out according to IEC 60270, and the sensitivity was 0.25 pC/mV. PD pulses were distributed in the phase of $50^{\circ}{\sim}135^{\circ}$ and over 95% of them existed in the phase of $55^{\circ}{\sim}120^{\circ}$ for the POC. PD pulses were distributed in the phase of $230^{\circ}{\sim}310^{\circ}$ and over 90% of them existed in phase of $220^{\circ}{\sim}300^{\circ}$ for the POE. PD pulses occurred in the phase of $40^{\circ}{\sim}60^{\circ}$ and $220^{\circ}{\sim}300^{\circ}$ for the crack, and pulse counts were 25% higher in negative polarity than in positive polarity. PD pulses were distributed in every phase unlike to other three electrode systems and the peak magnitude was measured at $118^{\circ}$ and $260^{\circ}$ for the FP. As described above, PD pulses were observed in positive polarity for the POC, in negative one for the POE, in both one for the crack and the FP. In conclusion, it is expected that the identification rate of defect type can be improved by considering the polarity ratio of PD pulses on the PRPDA method.

The Regenerative effects of Platelet-Rich Plasma and Enamel Matrix Protein on Grade III Furcation defects in beagle dogs (혈소판 농축혈장과 법랑기질 단백질이 성견 3급 이개부 병소의 재생에 미치는 영향)

  • Kim, Young-Jun;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.823-837
    • /
    • 2005
  • The purpose of this study was to study the histopathological correlation between the use of platelet-rich plasma and enamel matrix protein used in conjunction with xenograft. compared to a control group with regards to bone regeneration at the grade III furcation area in beagle dogs. Control group was treated with bovine derived bone $powder(Biocera^{(R)})$, and experimental I group was treated with bovine derived bone powder and Platelet-rich plasma and experimental II group was treated with bovine derived bone powder and Enamel matrix $protein(Emdogain^{(R)})$. The regeneration rate of bone formation was observed and compared histopathologically at 2. 4, and 8 weeks after surgery. The results were as follows: 1. In control group and both experimental groups. inflammatory cells were observed but, new bone formation wasn't. 2. In control group, new cementum on the notch was found in 4 weeks, less mature periodontal ligament when compared to that of experimental group was found and cementum formation was great but, regeneration couldn't be seen in 8 weeks. 3. Experimental I group. new bone formation in the area adjacent to alveolar bone and graft material surrounded by more dense connective tissue were found in 4 weeks. New bone formation up to crown portion was found and periodontal ligament was aligned functionally and cementum more mature. 4. Experimental II group, new bone formation was found under the defect area in 4 weeks and new bone formation around graft material in 8 weeks, too, and there were a number of fibroblasts, blood vessels, acellular cementum, which was less mature when compared to that of experimental I group, and dense collagen fiber like which normal periodontal ligament has in periodontal ligament of experimental II group in 8 weeks. 5. As a result of histologic finding, bone formation rate were 18.0${\pm}$7.87%(control group), 34. 05${pm}$7.25%(experimental I group), 19.33 ${pm}$5.15%(experimental II group) in 4 weeks and 21.89${pm}$1.58%(control group), 38.82${pm}$3.2(experimental I group), 37.65${pm}$9.22%(experimental II group) in 8 weeks. 6. Statistically significant ratio of bone formation was observed in experimental I group in 4 weeks and in experimental II group in 8 weeks. When experimental I group was compared to experimental II group, the ratio of bone formation in experimental I group was higher than that in experimental II group in 4 weeks(p<0.05). This results suggest that platelet-rich plasma showed more new bone formation than enamel matrix protein within 4 weeks. And use of enamel matrix protein in the treatment of periodontal bone defects starts to enhance regeneration after 8 weeks in beagle dogs.