• Title/Summary/Keyword: Defect level

Search Result 588, Processing Time 0.032 seconds

A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy (압전방식초음파치석제거기의작업조건에따른치과주조용합금의삭제결손부 양상에 관한 고찰)

  • Kim, Young-Sung;Kim, Soo-Hwan;Kim, Won-Kyung;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.4
    • /
    • pp.385-390
    • /
    • 2009
  • Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.

Effect of Alendronate on Bone Regeneration in Defect of Rat Calvaria (Alendronate가 백서에서 두개골 결손의 재생에 미치는 영향)

  • Jeong, Chan-Doo;Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.389-400
    • /
    • 2001
  • Previous studies have demonstrated an increase in bone mass and density with the use of bisphosphonate in osteoporosis. This agent acts as an inhibitor of osteoclastic activity, and results in increase of net osteoblastic activity. Currently, it has been reported that bisphosphonate has direct effect on osteoblast. This study was designed to evaluate the effect of alendronate on bone regeneration in defect of rat calvaria. The animals used for these experiments were 48 male rats, over 6-8 weeks old. They were divided into three groups according to the dose of alendronate($MK-217^{(R)}$, Merck, USA) administered. After the calvarial defects were surgically created, the rats received a peritoneal alendronate(0.25mg/kg) in group I, a peritoneal alendronate(1.25mg/kg) in group II, and a peritoneal normal saline injection in the control group. Three and six weeks later, blood was sampled and evaluated for alkaline phosphatase activity. The animals were sacrificed for histological observation and histometric analysis of the level of bone formation. The alkaline phosphatase activity was similar in three groups at 3 weeks of experiment. The activity at 6 weeks increased more than twice, compared to 3 weeks, and was slightly higher in group I than the other two groups. In histological observation, all the groups at 3 weeks, osteoblast rimming and new bone formation were observed along the defect margin. At 6 weeks, the defect was almost closed with new and more mature bone, but new bone is thinner than original bone in the central portion of defect. In histometric analysis, group I and II at 3 weeks showed significantly greater new bone formation than the control, and all the groups at 6 weeks showed similar amount of bone formation. These result suggest that alendronate administration in the dose of 0.25mg/kg and 1.25mg/kg promote osseous regeneration.

  • PDF

Electrical Properties and Defect States in ZnO Substrates Irradiated by MeV Electron-beam (고 에너지 전자빔 조사에 따른 ZnO 기판의 결함생성 및 전기적 특성 변화)

  • Lee, Dong-Uk;Song, Hoo-Young;Han, Dong-Seok;Kim, Seon-Pil;Kim, Eun-Kyu;Lee, Byung-Cheol
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.199-205
    • /
    • 2010
  • The electrical properties and defect states in ZnO substrates were studied during high-energy electron beam irradiations. 1 MeV and 2 MeV electron-beam with dose of $1{\times}10^{16}$ electrons/$cm^2$ were irradiated on Zn-surface of the sample. In the sample irradiated by 1 MeV, the leakage current was increased by electron-beam induced surface defects, while the enhancement of on/off property and the decrease of leakage current appeared in the 2 MeV irradiated sample. From the deep level transient spectroscopy measurements for these samples, it showed that the defect states with the activation energies of $E_c$-0.33 eV and $E_v$+0.8 eV are generated during the high energy electron-beam irradiation. Especially, it considered that the $E_c$-0.33 eV state related with O-vacancy affects to their electrical properties.

The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software

  • Park, Se-Won;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.107-113
    • /
    • 2020
  • PURPOSE. The aim of this study was to examine the importance of the defect-free scanning of a scan body by assessing the accuracy of virtual implant positioning in computer-aided design (CAD) software when the scan body image is improperly scanned. MATERIALS AND METHODS. A scan body was digitized in a dentiform model using an intraoral scanner, and scanned images with differing levels of image deficiency were generated: 5%, 10%, and 15% deficiency in the flat or rounded area. Using a best-fit image matching algorithm on each of the deficient scan body images, corresponding virtual implants were created. The accuracy of the implant position was evaluated by comparing the linear and angular discrepancies between the actual and virtual positions of the implant. Kruskal-Wallis tests and Mann-Whitney U tests with Bonferroni correction were used to determine the statistical differences among the seven scanned image deficiency groups (α=.05). RESULTS. In general, the linear and angular discrepancies of the implant position in the software increased as the deficiency of the scan body images increased. A 15% scan body image deficiency generated larger discrepancies than deficiency of 5% and 10%. The difference of scan defect position, flat or rounded area, did not affect the accuracy of virtual implant orientation at 5% and 10% deficiency level, but did affect the accuracy at 15% deficiency level. CONCLUSION. Deficiencies in the scanned images of a scan body can decrease the accuracy of the implant positioning in CAD software when the defect is large, thus leading to the incorrect fabrication of implant prostheses.

Low Speed Rolling Bearing Fault Detection Using AE Signal Analyzed By Envelop Analysis Added DWT (웨이블릿변환이 접목된 포락처리를 이용한 저속 회전하는 구름요소베어링 결함 진단)

  • Kim, Byeong-Su;Kim, Won-Cheol;Gu, Dong-Sik;Kim, Jae-Gu;Choi, Byeong-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.672-678
    • /
    • 2009
  • Acoustic Emission (AE) technique is a non-destructive testing method and widely used for the early detection of faults in rotating machines in these days, because the sensitivity of AE transducers is higher than normal accelerometers. So it can detect low energy vibration signals. The faults in the rotating machines are generally occurred at bearings and gearboxes which are the principal parts of the machines. It was studied to detect the bearing faults by envelop analysis in several decade years. And the researches showed that AE had a possibility of the application in condition monitoring system(CMS) using the envelope analysis for the rolling bearing. And peak ratio (PR) was developed for expression of the bearing condition in condition monitoring system using AE. Noise level is needed to reduce to take exact PR value because the PR is calculated from total root mean square (RMS) and the harmonics peak levels of the defect frequencies of the bearing. Therefore, in this paper, the discrete wavelet transform (DWT) was added in the envelope analysis to reduce the noise level in the AE signals. And then, the PR was calculated and compared with general envelope analysis result and the result of envelope analysis added the DWT. In the experiment result about inner fault of bearing, defect frequency was difficult to find about only envelop analysis. But it's easy to find defect frequency after wavelet transform. Therefore, Envelop analysis added wavelet transform was useful method for early detection of default in signal process.

Real-Time Textile Dimension Inspection System Using Zone-Crossing Method, Distortion Angle Classifier and Gray-Level Co-occurrence Matrix Features (영역교차법, 왜곡각 분류자 및 명암도 상관행렬 특징자를 이용한 실시간 섬유 성량 검사 시스템)

  • 이응주;이철희
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.2
    • /
    • pp.112-120
    • /
    • 2000
  • In this paper, we implement a real-time textile dimension inspection system. It can detect various types of real defects which determine the quality of fabric product, defect positions of textile, classify the distortion angel of moving textile and the density. In the implemented system, we measure the density of textile using zone-crossing method with optical lens to solve the noise and real-time problems. And we compensate distortion angel of textile with the classification of distortion types using gaussian gradient and mean gradient features. And also, it detecs real defects of textile and its positions using gray level co-occurrence matrix features. The implemented texile demension inspection systemcan inspect textile dimensions such as density, distortion angle, defect of textile and defect position at real-time. In the implemented proposed texitile dimension inspection system, It is possible to calculate density and detect default of textile at real-time dimension inspection system, it is possible to calculate density and detect default of textile at textile states throughout at all the significant working process such as dyeing, manufacturing, and other texitle processing.

  • PDF

Surgical Correction of Atrial Septal Defect in Adult (성인 심방중격결손증의 수술교정)

  • 이광선
    • Journal of Chest Surgery
    • /
    • v.28 no.9
    • /
    • pp.811-816
    • /
    • 1995
  • Repairs of atrial septal defect utilizing cardiopulmonary bypass were performed in 50 adults, ranging age from 16 to 53 years, since April 1986 up to October 1994. They occupied 38.8% of all adult congenital heart disease operated in the same period. Preoperatively, 16 patients were functional class II, 12 patients class III and 4 patients class IV[New York Heart Association Classification , respectively. Five patients combined with atrial fibrillation and the remainders revealed regular sinus rhythm. Cardiac catheterizations were performed in 43 out of 50 patients, and revealed a systolic pulmonary arterial pressure in excess of 51 mmHg in 4 patients but none had reversed shunt. 40 patients[80% were repaired with patch closure and remainings were repaired with direct closure. 49 patients were followed up for 2 months up to 102 months[average 55 months . A comparison of the preoperative and postoperative functional class demonstrated a mean decrease of one NYHA functional level[2.5$\pm$0.63 to 1.4$\pm$0.56 . There was no operative mortality. One patient died during the follow-up period and the death was unrelated to heart disease. Operative treatment is indicated for repair of atrial septal defect with left to right shunt in the adult patient and a considerable clinical improvement can be anticipitated with low mortality.

  • PDF

A fault prevention diagnostic of power transformer using Frequency Response Analysis (주파수 응답 분석(FRA)을 이용한 전력용 변압기 고장예방 진단)

  • Cho, Yun-Haeng;Lim, Tae-Young;Kim, Jong-Seon;Kim, Gi-Il;Ahn, Kwang-Won;Lim, Seong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.463-464
    • /
    • 2011
  • Currently, different kinds of diagnosis and inspection technologies are applied to prevent the internal mechanical transformation of transformers. For example, examination of internal Partial Discharge of transformer, analysis of transformer oil gas, and measurement Frequency Response Analyzer(FRA) are used to diagnose defect. Especially, diagnosis technique through Frequency Response Analyzer(FRA) has been used and developed from 1960, when it was first introduced, till now to become an important tool to examine presence of defect and to prove quality of machines for the most electric machine producers electric power company in the world. However, diagnosis through FRA is still in introduction level in Korea and the application method for FRA is not established yet. For that reason, study about the application of domestic electric installation according to the FRA is needed. It is expected that the study play an important part in the prevention of defect due to the internal transformation of transformer by introducing measurement theory, providing measurement method, and analyzing application cases.

  • PDF

A study on the deep levels in boron ion implanted semi-insulating GaAs by PICTS (PICTS방법에 의한 Boron이온을 주입시킨 반절연성 GaAs의 깊은준위에 관한 연구)

  • 최현태;김인수;이철욱;손정식;김영일;배인호
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.426-433
    • /
    • 1995
  • Effect of boron in GaAs have been investigated by photo induced current transient spectroscopy(PICTS). The starting material was undoped liquid encapsulated Czochralski(LEC) semi insulating GaAs and boron ion implantation at 150keV energy was conducted with dose of 10$\^$12/ and 10$\^$13/ions/cm$\^$2/. In ion implanted samples, the peaks related arsenic vacancy(V$\_$As/) were decreased but complex lattice defect was increased with annealing temperature. U band was observed at ion implanted(10$\^$13/ ions/cm$\^$2/) and thermally treated(550.deg. C) sample. More negative peak was detected after annealing at temperature between 600 and 700.deg. C. The measurement of dark current showed that the formation of B$\_$GA/-V$\_$As/, complex defect and complex lattice defect by ion implantation were a reasonable explanation for the decrease in dark current.

  • PDF

The Development of New Cost-Effective Optimization Technology for OLED Market Entry

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Journal of Distribution Science
    • /
    • v.17 no.4
    • /
    • pp.51-57
    • /
    • 2019
  • Purpose - This study aims to improve the distribution structure of the OLED market and develop cost-effective optimization techniques. Specifically, it is a study on the optimization of ferric chloride to improve the etch of SUS MASK for OLED. Research design, data, and methodology - Applying the optimal conditions of the experiment, the final confirmation was evaluated for improvement by the Process Capability Index (Cpk). It is possible to derive social performance such as improvement of precision of SUS MASK manufacturing, economic performance such as defect rate, reduction of waste generation and treatment cost, technological achievement such as SUS MASK production technology, improvement of profit structure of technology development and process improvement do. Results - The improvement of the Cpk before the improvement was made was confirmed to be 0.57% with a defect estimate of 25.07% with a failure estimate of 0.57% after the improvement, and 8.84% with a failure estimate of 0.57% level after the improvement. Conclusions - If the conclusions obtained from the specimen experiment are applied to the manufacturing process of SUS MASK, it will be possible to expect excellent cost-effective competitiveness due to the improvement of precision and reduction of defect rate to enhance the OLED market penetration.