• Title/Summary/Keyword: Defect Profile

Search Result 81, Processing Time 0.029 seconds

Reliability Design Analysis for Underwater Buriend PBA Based on PoF (고장물리 기반 수중 매설형 PBA에 대한 신뢰성 설계 연구)

  • Kim, Ji-Young;Lee, Ki-Won;Yoon, Hong-Woo;Lee, Seung-Jin;Heo, Jun-Ki;Kwon, Hyeong-Ahn
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.280-288
    • /
    • 2017
  • Purpose: PBA buried in underwater requires high reliability because of its mission critical characteristic and harsh operational environment during its life cycle. Therefore, various reliability improvement activities are necessary. The defect on PBA manufacturing process have been studied, as a result, many activities and standards have been presented. However, there are less studies regarding failure pattern on physical features based on design. In this paper, we studied a possible failure patten based on physical features that is related with manufacturing process of PBA. And reliability improvement design based on PoF (Physical of Failure) were intruduced in this paper. Methods: A reliability prediction simulation were performed on the components A and B of the H system using Sherlock Software which is a PoF commercial tool from DFR solution. Solder fatigue and PTH fatigue analysis based on thermal cycling profiles and random vibration was analyzed on three earthquake response spectrum. Result: It was validated that life time and reliability improvement design through solder fatigue and PTH fatigue analysis in case of component. For compoenet B, random vibration fatigue was additionally analyzed and validated reliability for earthquakes profile. Conclusion: In design stage prior to manufacturing, PoF can be analyzed, and it is possible to make a reliability improvement/validated design using design data. This study can be applied in every design step and contribute to make more stable development product.

Physicochemical and microbial characteristics of longissimus lumborum and biceps femoris muscles in Korean native black goat with wet-aging time

  • Ali, Mahabbat;Park, Ji-Young;Lee, Seong-Yun;Choi, Young-Sun;Nam, Ki-Chang
    • Journal of Animal Science and Technology
    • /
    • v.63 no.1
    • /
    • pp.149-159
    • /
    • 2021
  • This study examined the effects of different wet-aging times on the physicochemical characteristics and microbial profile of longissimus lumborum (LL) and biceps femoris (BF) muscles from Korean native black goat (KNBG) meat. The water holding capacity (WHC), pH, cooking loss, shear force, meat color, free amino acid, total bacteria, and coliform count of KNGB meat were analyzed at 0, 5, 10, and 15 days of wet-aging at 4℃ under vacuum packaging. The results showed that different wet-aging times led to significant pH variations between the muscles throughout the aging period. The wet-aging time did not affect the WHC and cooking loss in meat from the LL muscle. In the BF muscle, however, meat wet-aged for five days had a significantly higher WHC and less cooking loss than meat aged for 0, 10, and 15 days. The meat from the LL muscle wet-aged for five days produced tenderer meat (low shear force value) than the unaged meat (p < 0.05). Moreover, the color was similar in the LL muscle regardless of the number of aging days. In the BF muscle, the redness (a*) was higher in the meat wet-aged for 15 days compared to that aged for 0, 5, and 10 days (p < 0.05). Regardless of the muscles, an increase in wet-aging time led to an increase in the total free amino acids contents in both muscles (p < 0.05). On the other hand, the tasty/bitter amino acid ratio was significantly higher for five days of wet-aged meat than 10 and 15 days of aging from the BF muscle. In addition, regardless of the muscles, the total bacteria and coliform counts were significantly lower for five days of wet-aged meat than 10 and 15 days of aging (p < 0.05). Therefore, chevon wet-aged for five days is an optimal aging period under vacuum packaging that fortifies meat quality with a minimal microbial negative defect.

Esthetic implant restoration in the maxillary anterior missing area with palatal defect of the alveolar bone: a case report (구개부 치조골 결손을 보이는 상악 전치 상실부의 임플란트 심미보철수복: 증례보고)

  • Oh, Jae-Ho;Kang, Min-Gu;Lee, Jeong-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.291-298
    • /
    • 2017
  • It is challenging to produce esthetic implant restoration in the narrow anterior maxilla region where insufficient volume of alveolar bone could limit the angle and position of implant fixture, if preceding bone augmentation is not considered. Ideal angle and position of implant fixture placement should be established to reproduce harmonious emergence profile with marginal gingiva of implant prosthesis, bone augmentation considered to be preceded before implant placement occasionally. In this case, preceding bone augmentation has been operated before esthetic implant prosthesis in narrow anterior maxilla region. Preceded excessive bone augmentation in buccal area allowed proper angulation of implantation, which compensates unfavorable implant position. Provisional restorations were corrected during sufficient period to make harmonious level of marginal gingiva and interdental papilla. The definite restoration was fabricated using zirconia core based glass ceramic. Functionally and esthetically satisfactory results were obtained.

Electrochemical Characteristics of Li3V2(PO4)3 Negative Electrode as a Function of Crystallinity (결정화도에 따른 Li3V2(PO4)3 음극의 전기화학적 특성)

  • Ku, Jun-Whan;Park, Kyung-Jin;Ryu, Ji-Heon;Oh, Seung-Mo
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.1
    • /
    • pp.27-34
    • /
    • 2012
  • $Li_3V_2(PO_4)_3$/carbon composite materials are synthesized from a sucrose-containing precursor. Amorphous $Li_3V_2(PO_4)_3/C$ (a-LVP/C) and crystalline $Li_3V_2(PO_4)_3/C$ (c-LVP/C) are obtained by calcining at $600^{\circ}C$ and $800^{\circ}C$, respectrively, and electrochemical performance as the negative electrode for lithium secondary batteries is compared for two samples. The a-LVP electrode shows much larger reversible capacity than c-LVP, which is ascribed to the spatial $Li^+$ channels and flexible structure of amorphous material. In addition, this electrode shows an excellent rate capability, which can be accounted for by the facilitated $Li^+$ diffusion through the defect sites. The sloping voltage profile is another advantageous feature for easy SOC (state of charge) estimation.

Report of East Sea Crossing by Underwater Glider (수중 글라이더를 이용한 동해 횡단 사례 보고)

  • Park, Yo-Sup;Lee, Shin-Je;Lee, Yong-Kuk;Jung, Seom-Kyu;Jang, Nam-Do;Lee, Ha-Woong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.2
    • /
    • pp.130-137
    • /
    • 2012
  • The underwater glider using conception of Lagrangian method, is a new observation platform to understand the properties of the ocean vertically. In 2011 March, KORDI made a first successful autonomous trip from Hupo to west coast of Uleungdo piloting Littoral Glider of Alaska Native Technology LLC. The journey considered many environmental variables and route vigilantly selected, the glider covered 177 km horizontally and took approximately 6 days (153 hours). Despite the existence of 1 kt eddy current, Sound velocity sampling was conducted from 5 meters and reaching maximum of 200 meters depth at each dive. It successfully collected sound velocity and temperature profile at every 5 seconds totaling up to 1408 profiles using SVT&P sensor. During the flight it was also a mission to check the diverse modes of the glider i.e. spiral, waypoints, heading, drift and hover could function without a defect in a given situation. These modes were thoroughly monitored and it could be considered that the glider handled it well during the flight. As a result of this test flight, it was evident that the given underwater glider could operate under 2kt current environment with users defined heading and depth, also with the payload up to 5 kg without changing internal buoyancy.

Controlled release of nerve growth factor from heparin-conjugated fibrin gel within the nerve growth factor-delivering implant

  • Lee, Jin-Yong;Kim, Soung-Min;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.3-10
    • /
    • 2014
  • Objectives: Although nerve growth factor (NGF) could promote the functional regeneration of an injured peripheral nerve, it is very difficult for NGF to sustain the therapeutic dose in the defect due to its short half-life. In this study, we loaded the NGF-bound heparin-conjugated fibrin (HCF) gel in the NGF-delivering implants and analyzed the time-dependent release of NGF and its bioactivity to evaluate the clinical effectiveness. Materials and Methods: NGF solution was made of 1.0 mg of NGF and 1.0 mL of phosphate buffered saline (PBS). Experimental group A consisted of three implants, in which $0.25{\mu}L$ of NGF solution, $0.75{\mu}L$ of HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin was injected via apex hole with micropipette and gelated, were put into the centrifuge tube. Three implants of experimental group B were prepared with the mixture of $0.5{\mu}L$ of NGF solution, $0.5{\mu}L$ HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin. These six centrifuge tubes were filled with 1.0 mL of PBS and stirred in the water-filled beaker at 50 rpm. At 1, 3, 5, 7, 10, and 14 days, 1.0 mL of solution in each tubes was collected and preserved at $-20^{\circ}C$ with adding same amount of fresh PBS. Enzyme-linked immunosorbent assay (ELISA) was done to determine in vitro release profile of NGF and its bioactivity was evaluated with neural differentiation of pheochromocytoma (PC12) cells. Results: The average concentration of released NGF in the group A and B increased for the first 5 days and then gradually decreased. Almost all of NGF was released during 10 days. Released NGF from two groups could promote neural differentiation and neurite outgrowth of PC12 cells and these bioactivity was maintained over 14 days. Conclusion: Controlled release system using NGF-HCF gel via NGF-delivering implant could be an another vehicle of delivering NGF to promote the nerve regeneration of dental implant related nerve damage.

ORAL REHABILITATION IN ECTODERMAL DYSPLASIA WITH OLIGODONTIA

  • Kim, Ryoung;Choi, Yeong-Chul;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.636-643
    • /
    • 1999
  • Ectodermal dysplasia is a genetic birth defect in which at least abnormally develop two structures derived from the ectoderm. It is usually inherited in autosomal dominant or autosomal recessive pattern. Oral manifestations are oligodontia, anodontia, dysmorphic teeth(conical shape), decreased occlusal vertical dimension and alveolar bone. Extraoral signs may include decreased or absent sweat glands, sparse and fine hair, saddle nose, hearing loss and decreased production of body fluids including saliva. Most affected children require extensive dental treatment to restore their appearance and help the development of a positive self image. The patient's overclosed profile was due to a decreased vertical dimension. The use of overdenture is to preserve erupted teeth, to accomodate the newly constructed occlusal plane, to improve retention and stability of denture and to maintain the remaining alveolar bone. The restoration of vertical dimension improved the child's speech, swallowing, and eating. Growth continue until the age of approximately 18. As child grows, replacement dentures will have to be fabricated primarily to accomodate increasing vertical dimension and changing dentition. Implants may be indicated later if the alveolar bone is adequate. Periodic recall visits are advised, to monitor the dentures during periods of growth and development, and eruption of the permanent teeth.

  • PDF

Three key factors for successful esthetic anterior implant restoration (성공적인 전치부 심미 임플란트를 위한 3가지 요소)

  • Lim, Pil
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.35-49
    • /
    • 2016
  • With the increasing demand for aesthetic implant dentistry, the importance of implant restoration is emphasized not only in the functional aspect but also in the aesthetic aspect. The aesthetic restoration of dental implants in the anterior maxilla is a challenge for clinicians because it requires proper harmony in three following conditions; reconstruction of hard tissue, soft tissue, and aesthetic prosthesis. The soft tissue aesthetics are dependent upon the condition of the supporting hard tissue because the osseous structure provides a framework for the development of a healthy and aesthetic soft tissue interface. Therefore, the augmentation of hard tissue is a first step and especially, optimal 3-dimensional position of implant is the most important factor in aesthetic implant restoration. The management of soft tissue is a second step, and the final step is a restoration of harmonic prosthesis using provisional restoration with proper emergence profile. This clinical report describes the procedure of bone augmentation in labial dehiscence defect, Vascularized Interpositional Periosteal-Connective Tissue (VIP-CT) flap for aesthetic anterior soft tissue, and the importance of provisional restoration and impression taking stage with customized impression coping.

Effects of Maxillary Lateral Incisor Agenesis on Skeletodental Characteristics in Mixed Dentition (상악 측절치 결손이 어린이 안면골격과 치열궁 형태에 미치는 영향)

  • Nam, Siyeon;Shin, Jonghyun;Kim, Jiyeon;Jeong, Taesung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.147-157
    • /
    • 2019
  • This study aimed to evaluate skeletodental characteristics of patient with maxillary lateral incisor agenesis (MLIA) in mixed dentition. It involved the children in early mixed dentition who visited Pusan National University dental hospital for orthodontic purposed and had intact primary canines. 38 children with MLIA and 38 controls with the same chronological age satisfying the inclusion criteria were selected. The craniofacial structures and dental arch dimensions of the MLIA were evaluated using model & cephalometric analysis and compared to controls. The rate of unilateral MLIA was high in male and the rate of bilateral MLIA was high in female. In model analysis, the width / length ratio of maxillary anterior portion of the MLIA group were higher and arch perimeter of the maxilla of the MLIA group were smaller than those of the control group (p = 0.003, 0.04). Cephalometric analysis showed that there were no significant differences in terms of skeletal, dental analysis. In soft tissue profile, nasolabial angle was larger in MLIAs than in controls (p = 0.039). Considering these skeletodental characteristics of MLIA, early diagnosis and proper management is highly recommended to minimize the possibility of functional defect.

Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease (관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성)

  • Lee, Duk-Young;Bae, Jin-Ho;Lee, Sang-Woo;Chun, Kyung-Ah;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Ha, Jeoung-Hee;Chae, Shung-Chull;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.473-480
    • /
    • 2005
  • Purpose: Adenosine myocardial perfusion SPECT has proven to be useful in the detection of coronary artery disease, in the follow up the success of various therapeutic regimens and in assessing the prognosis of coronary artery disease. The purpose of this study is to define the reproducibility of myocardial perfusion SPECT using adenosine stress testing between two consecutive Tc-99m sestaMIBI (MIBI) SPECT studies in the same subjects. Methods: Thirty patients suspected of coronary artery disease in stable condition underwent sequential Tc-99m MIBI SPECT studies using intravenous adenosine. Gamma camera, acquisition and processing protocols used for the two tests were identical and no invasive procedures were performed between two tests. Mean interval between two tests were 4.1 days (range: 2-11 days). The left ventricular wall was divided into na segments and the degree of myocardial tracer uptake was graded with four-point scoring system by visual analysis. Images were interpretated by two independent nuclear medicine physicians and consensus was taken for final decision, if segmental score was not agreeable. Results: Hemodynamic responses to adenosine were not different between two consecutive studies. There were no serious side effects to stop infusion of adenosine and side effects profile was not different. When myocardial uptake was divided into normal and abnormal uptake, 481 of 540 segments were concordant (agreement rate 89%, Kappa index 0.74). With four-grade storing system, exact agreement was 81.3% (439 of 540 segments, tau b=0.73). One and two-grade differences were observed in 97 segments (18%) and 4 segments (0.7%) respectively, but three-grade difference was not observed in any segment. Extent and severity scores were not different between two studios. The extent and severity scores of the perfusion defect revealed excellent positive correlation between two test (r value for percentage extent and severity score is 0.982 and 0.965, p<0.001) Conclusion: Hemodynamic responses and side effects profile were not different between two consecutive adenosine stress tests in the same subjects. Adenosine Tc-99m sestaMIBI SPECT is highly reproducible, and could be used to assess temporal changes in myocardial perfusion in individual patients.