• 제목/요약/키워드: Defect Imaging

검색결과 274건 처리시간 0.02초

Quantitative measurement of peri-implant bone defects using optical coherence tomography

  • Kim, Sulhee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Bome;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.84-91
    • /
    • 2018
  • Purpose: The purpose of this study was to visualize and identify peri-implant bone defects in optical coherence tomography (OCT) images and to obtain quantitative measurements of the defect depth. Methods: Dehiscence defects were intentionally formed in porcine mandibles and implants were simultaneously placed without flap elevation. Only the threads of the fixture could be seen at the bone defect site in the OCT images, so the depth of the peri-implant bone defect could be measured through the length of the visible threads. To analyze the reliability of the OCT measurements, the flaps were elevated and the depth of the dehiscence defects was measured with a digital caliper. Results: The average defect depth measured by a digital caliper was $4.88{\pm}1.28mm$, and the corresponding OCT measurement was $5.11{\pm}1.33mm$. Very thin bone areas that were sufficiently transparent in the coronal portion were penetrated by the optical beam in OCT imaging and regarded as bone loss. The intraclass correlation coefficient between the 2 methods was high, with a 95% confidence interval (CI) close to 1. In the Bland-Altman analysis, most measured values were within the threshold of the 95% CI, suggesting close agreement of the OCT measurements with the caliper measurements. Conclusions: OCT images can be used to visualize the peri-implant bone level and to identify bone defects. The potential of quantitative non-invasive measurements of the amount of bone loss was also confirmed.

Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study

  • Avinash Mani;Sivadasanpillai Harikrishnan;Bijulal Sasidharan;Sanjay Ganapathi;Ajit Kumar Valaparambil
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.180-187
    • /
    • 2023
  • BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.

내측 반월상 연골판 후각 기시부 파열 봉합 후 추시 자기공명영상 검사의 유용성 (Magnetic resonance imaging Usefulness after Medial Meniscus Posterior Root Tear Repair)

  • 전재균;김준범;이봉주
    • 대한관절경학회지
    • /
    • 제17권1호
    • /
    • pp.6-10
    • /
    • 2013
  • 목적: 슬관절 내측 연골판 후각 기시부 파열에 대하여 관절경적 봉합 수술을 시행한 후 유합 유무를 평가하기 위한 magnetic resonance imaging (MRI)의 유용성에 대하여 보고 하고자 한다. 대상 및 방법: 2007년 11월부터 2011년 6월까지 내측 반월상 연골판 후각 기시부 파열을 봉합한 환자 중 술후 MRI와 관절경검사를 모두 시행하였던 17명을 대상으로 하였다. 관절경검사와 MRI 검사를 시행하여 비교하였다. 결과: 술전 Lysholm knee score는 평균 56.4에서 평균 79.0으로 visual analogue scale (VAS) score는 8점에서 3점으로 호전되었다. 2차적 관절경 검사상 17예 모두 섬유화 재생 후 안정화된 소견이 확인되었다. 그러나 MRI 검사에서 내측 반월상 연골판 후각 기시부 파열을 시사하는 수직 직선 결함(cleft sign)은 술전후 모두 관찰되었고, 음영 손실(ghost sign)은 술전 10예에서 술후 9예, 방사선 직선 결함(radial linear defect) 소견은 술전 17예에서 술후는 15예에서 확인되었다. 결론: 내측 반월상 연골판 후각 기시부 파열의 관절경적 봉합술을 시행한 환자를 대상으로 비해부학적 위치에 봉합한 경우 술후 추시 MRI 검사는 유합 여부 판단에 유용하지 않았다. 유합 여부를 정확하게 평가하기 위해서는 관절경적 검사가 필요한 것으로 판단된다.

  • PDF

심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하 (Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA)

  • 공은정;조인호;천경아;원규장;이형우;박종선
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Ghandari, Farnaz;Hadinezhad, Arash
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel(PPA) and oblique projected periapical(OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects(10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects(P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.

GaAs 웨이퍼의 적외선 영상기법 및 콘트라스트 반전 영상에 대한 새로운 해석 (Infrared Imaging and a New Interpretation on the Reverse Contrast Images in GaAs Wafer)

  • 강성준
    • 한국정보통신학회논문지
    • /
    • 제20권11호
    • /
    • pp.2085-2092
    • /
    • 2016
  • IC 기판의 가장 중요한 성질들의 하나는 넓은 영역에 걸쳐 균일해야만 한다는 것이다. 웨이퍼 결함 분석의 다양한 물리적 접근 방법 중에서 적외선 조사 기법에 특별한 관심이 모아지고 있다. 특히, 높은 공간적 분해력을 가지고 있는 근적외선 흡수 방법은 반-절연 GaAs 내의 결함들을 직접적으로 관찰하는데 이용되고 있다. 적외선 전송에 기초를 둔 이 기법은 신속하고 비파괴 적이다. 이 방법은, 직접적으로 GaAs 반도체의 적외선 영상은 결함의 광흡수 작용에 기인한 것임을 밝히고 있다. 반-절연 GaAs 내의 EL2에 관련된, 비 균일 적으로 분포된 결함들의 적외선 흡수 영상에서 콘트라스트가 반전되는 현상에 대해 새로운 모델을 제시하고 있다. 저온 포토퀀칭 실험은, 직접적인 방법으로, GaAs 웨이퍼의 콘트라스트 반전 영상은 밴드갭의 지엽적인 변동이나 전하 재분포에 의한 것이 아니라 흡수와 산란의 두 메커니즘에 의한 것임을 증명하고 있다.

Time Course of Ventricular Remodeling after Atrial Septal Defect Closure in Adult Patients

  • Bae, Yo Han;Jang, Woo Sung;Kim, Jin Young;Kim, Yun Seok
    • Journal of Chest Surgery
    • /
    • 제54권1호
    • /
    • pp.45-52
    • /
    • 2021
  • Background: Atrial septal defect (ASD) is the most common congenital heart disease. However, the details of cardiac chamber remodeling after surgery are not well known, although this is an important issue that should be analyzed to understand long-term outcomes. Methods: Between November 2017 and January 2019, cardiac magnetic resonance imaging was performed preoperatively, at a 1-month postoperative follow-up, and at a 1-year postoperative follow-up. Cardiac chamber volume, valve regurgitation volume, and ejection fraction were measured as functions of time. Results: Thirteen patients (10 men and 3 women) were included. The median age at surgery was 51.4 years. The preoperative median ratio of flow in the pulmonary and systemic circulation was 2.3. The preoperative mean right ventricular (RV) end-diastolic volume index (EDVi) and RV end-systolic volume index (ESVi) had significantly decreased at the 1-month postoperative follow-up (p<0.001, p=0.001, respectively). The decrease in the RVEDVi (p=0.085) and RVESVi (p=0.023) continued until the postoperative 1-year follow-up, although the rate of decrease was slower. Tricuspid valve regurgitation had also decreased at the 1-month postoperative follow-up (p=0.022), and continued to decrease at a reduced rate (p=0.129). Although the RVEDVi and RVESVi improved after ASD closure, the RV volume parameters were still larger than the left ventricular (LV) volume parameters at the 1-year follow-up (RVEDVi vs. LVEDVi: p=0.016; RVESVi vs. LVESVi: p=0.001). Conclusion: Cardiac remodeling after ASD closure is common and mainly occurs in the early postoperative period. However, complete normalization does not occur.

Micro-computed tomography for assessing the internal and external voids of bulk-fill composite restorations: A technical report

  • Tosco, Vincenzo;Monterubbianesi, Riccardo;Furlani, Michele;Giuliani, Alessandra;Putignano, Angelo;Orsini, Giovanna
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.303-308
    • /
    • 2022
  • Purpose: This technical report aims to describe and detail the use of micro-computed tomography for a reliable evaluation of the bulk-fill composite/tooth interface. Materials and Methods: Bulk-fill composite restorations in tooth cavities were scanned using micro-computed tomography to obtain qualitatively and quantitatively valuable information. Two-dimensional information was processed using specific algorithms, and ultimately a 3-dimensional (3D) specimen reconstruction was generated. The 3D rendering allowed the visualization of voids inside bulk-fill composite materials and provided quantitative measurements. The 3D analysis software VG Studio MAX was used to perform image analysis and assess gap formation within the tooth-restoration interface. In particular, to evaluate internal adaptation, the Defect Analysis addon module of VG Studio Max was used. Results: The data, obtained with the processing software, highlighted the presence and the shape of gaps in different colours, representing the volume of porosity within a chromatic scale in which each colour quantitatively represents a well-defined volume. Conclusion: Micro-computed tomography makes it possible to obtain several quantitative parameters, providing fundamental information on defect shape and complexity. However, this technique has the limit of not discriminating materials without radiopacity and with low or no filler content, such as dental adhesives, and hence, they are difficult to visualise through software reconstruction.

Nondestructive sensing technologies for food safety

  • Kim, M.S.;Chao, K.;Chan, D.E.;Jun, W.;Lee, K.;Kang, S.;Yang, C.C.;Lefcourt, A.M.
    • 한국환경농학회:학술대회논문집
    • /
    • 한국환경농학회 2009년도 정기총회 및 국제심포지엄
    • /
    • pp.119-126
    • /
    • 2009
  • In recent years, research at the Environmental Microbial and Food Safety Laboratory (EMFSL), Agricultural Research Service (ARS) has focused on the development of novel image-based sensing technologies to address agro-food safety concerns, and transformation of these novel technologies into practical instrumentation for industrial implementations. The line-scan-based hyperspectral imaging techniques have often served as a research tool to develop rapid multispectral methods based on only a few spectral bands for rapid online applications. We developed a newer line-scan hyperspectral imaging platform for high-speed inspection on high-throughput processing lines, capable of simultaneous multiple inspection algorithms for different agro-food safety problems such as poultry carcass inspection for wholesomeness and apple inspection for fecal contamination and defect detection. In addition, portable imaging devices were developed for in situ identification of contamination sites and for use by agrofood producer and processor operations for cleaning and sanitation inspection of food processing surfaces. The aim of this presentation is to illustrate recent advances in the above agro.food safety sensing technologies.

  • PDF

디지털 카메라용 줌렌즈에서 대칭성 오차요인에 의한 상면 변화의 보정과 이에 따른 불량률 예측 (Correction method for the Variation of the Image Plane Generated by Various Symmetric Error Factors of Zoom Lenses of Digital Still Cameras and Estimation of Defect Rate Due to the Correction)

  • 류재명;강건모;이해진;이혁기;조재흥
    • 한국광학회지
    • /
    • 제17권5호
    • /
    • pp.420-429
    • /
    • 2006
  • 곡률, 두께, 굴절률 오차와 같은 광축대칭 오차요인들 때문에 상면이 이동하는 디지털 카메라용 줌렌즈 광학계에서 보상자를 이동시켜서 상면을 고정시키는 조건을 가우스 괄호법을 이용하여 유도하였다. 그리고 줌렌즈 광학계의 일반적인 세 가지 형태(3군, 4군, 5군 줌렌즈)를 사용하여 이 조건의 타당성을 검증하였다. 이러한 줌렌즈 형태에서 각 면의 곡률, 두께, 굴절률 등을 공차 내에서 Monte Carlo 방법에 따라 임의로 변화시켰을 때, 보상자의 이동량의 분포가 정규분포를 이루는 것을 확인하였다. 그리고 이로부터 공정능력을 계산하여 보상자의 최대 이동량에서 이에 따른 불량률을 이론적으로 예측하는 방법을 제시하였다.