• Title/Summary/Keyword: Defect Evaluation

Search Result 681, Processing Time 0.036 seconds

Long-term radiographic evaluation of GTR treatment in intrabony defect (골연하 결손부에서 조직유도재생술의 장기적 방사선학적 변화 관찰)

  • Choi, Mi-Hye;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.181-192
    • /
    • 2007
  • Periodontal surgery as part of the treatment of periodontal disease is mainly performed 1) to gain access to diseased areas for adequate cleaning; 2) to achieve pocket reduction or elimination; and 3) to restore the periodontal tissues lost through the disease; i.e., a new attachment formation of periodontal regeneration. To accomplish the latter, often referred to as the ultimate goal of periodontal therapy, a number of surgical procedures have been advocated throughout the years. Clinical studies have demonstrated that considerable gain of clinical attachment and bone can be achieved following guided tissue regeneration (GTR) therapy of intrabony defects. The aim of this study was to analyse the radiographic bone changes 2-year after GTR using a bone graft material and nonresorbable membrane. Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of intrabony defect(s), 33 sites of 30 patients aged 32 to 56 (mean age 45.6) were treated by GTR with a bone graft material and nonresorbable membrane. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. We observed $2.86{\pm}1,87mm$ of bone fill, $065{\pm}0.79mm$ of crestal resorption, $3.49{\pm}2.11mm$ of defect resolution, and $44.42{\pm}19.51%$ of percentage of defect resolution. Mandible, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. But no difference was observed between xenograft and allograft. Outcome of GTR as a therapy of intrabony defect was better than other therapy, but herein, good oral hygiene maintenance as a anti-infective treatment and periodic recall check of patients are essential.

The Effect of Fibrillar Collagen on Bony Healing of Calvarial Defect in Rats (골 조직 치유과정에서 Collagen 막의 효과)

  • Kim, Jae-Bung;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.355-373
    • /
    • 1999
  • Many researches have been reported that collagen as cellular stroma, matrix of grafting materials, mediator of agents for the purpose of promoting healing process invivo, but the responses in vivo were seen various. The goal of this experiment is to assess the effect of collagen on bony healing, through histological evaluation of implanted collagen on the calvarial defect in rats. 2-month-old Sprague-Dawley, 24 rats were used and 12 rats assigned to each group of control and test. Defect of 5mm in diameter was made on the calvarial bone with trephine bur. Following thorough saline rinse, defect of control group was left in empty and that of experimental group was filled with fibrillar collagen($COLLATAPE^{(R)}$, COLLA-TEC. INC. U.S.A.) soaked in saline. 3 rats in each group were sacrificed at 3, 7, 14, 21 days after operation respectively, and the tissue blocks were prepared for light microscope with H-E for evaluation of overall healing, with TRAP(tartrate resistant acid phosphatase) for evaluation of osteoclastic activity and with immunohistochemical staining for macrophages. The results were as follows : 1. In the control group, inflammatory responses were disappeared at day 14, but, in the experimental group inflammatory infiltrates were reduced at day 21. Thus, the experimental group showed more severe soft tissue inflammation than control group. 2. Both control and experimental group showed slight appositional growth at day 7 and gradual bony growth to 21th day. But, complete bony healing of the defect was not shown. There was no significant difference in bony healing between control and experimental group 3. Specific response of macrophages for implanted collagen was observed at day 14 in the experimental group. In conclusion, although fibrillar collagen caused inflammation of soft tissue during initial healing period, inflammatory responses by fibrillar collagen didn't inhibit bony regeneration and implanted collagen was biodegradaded by macrophages. Thus, we expect that fibrillar collagen can be used for useful mediator of graft materials or growth factors.

  • PDF

Evaluation of Defect Types for Characteristic Database Construction of Large Sewage Box Culverts (대형 하수박스암거의 속성 데이터베이스 구축을 위한 결함유형 평가)

  • Han, Sangjong;Song, Homyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.619-628
    • /
    • 2017
  • As the 3D laser scanning technology capable of databaseing large sewage box culverts becomes possible, it is necessary to develop a standardization manual that can clearly distinguish the structural and operational defect types of box culver and analyze the defect data. In this study, we collected and analyzed defects in sewage box culverts of 14,827m in total by selecting three districts in Korea. The major defects were surface damages, and their defect densities were $2.17m^2/m$, $0.27m^2/m$ and $0.10m^2/m$ for aggregate exposure, Steel reinforcement exposure, and Steel reinforcement projecting. In order to support the decision of the box culverment management, it was divided into five grades and each defect code and defect score were allocated. The results of this study are useful for the diagnosis of the sewage box culverts in Korea and it is expected to support a decision making for management.

Determination of defect depth in industrial radiography imaging using MCNP code and SuperMC software

  • Khorshidi, Abdollah;Khosrowpour, Behzad;Hosseini, S. Hamed
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1597-1601
    • /
    • 2020
  • Background: Non-destructive evaluation of defects in metals or composites specimens is a regular method in radiographic imaging. The maintenance examination of metallic structures is a relatively difficult effort that requires robust techniques for use in industrial environments. Methods: In this research, iron plate, lead marker and tungsten defect with a 0.1 cm radius in spherical shape were separately simulated by MCNP code and SuperMC software. By 192Ir radiation source, two exposures were considered to determine the depth of the actual defined defect in the software. Also by the code, displacement shift of the defect were computed derived from changing the source location along the x- or y-axis. Results: The computed defect depth was identified 0.71 cm in comparison to the actual one with accuracy of 13%. Meanwhile, the defect position was recognized by disorder and reduction in obtained gamma flux. The flux amount along the x-axis was approximately 0.5E+11 units greater than the y-axis. Conclusion: This study provides a method for detecting the depth and position of the defect in a particular sample by combining code and software simulators.

Defect Assessment for Integrity Evaluation of CANDU Pressure Tubes (CANDU 압력관 건전성평가를 위한 결함해석)

  • 김영진;석창성;박윤원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.731-740
    • /
    • 1995
  • The objective of this paper is to develop defect assessment technology for integrity evaluation of CANDU pressure tubes. In fracture mechanics analysis, three-dimensional and two-dimensional (line-spring model) finite element analyses were performed to obtain the stress intensity factor for axial and circumferential surface cracks. In leak before break (LBB) analysis, heat transfer analyses for through-wall cracks were performed by considering the cooling effect and the LBB application time was computed. It was shown that the analytical results obtained in this study provide less-conservative but accurate solution for defect assessment of CANDU pressure tubes.

Performance Advancement of Evaluation Algorithm for Inner Defects in Semiconductor Packages (반도체 패키지 내부결함 평가 알고리즘의 성능 향상)

  • Kim, Chang-Hyun;Hong, Sung-Hun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.82-87
    • /
    • 2006
  • Availability of defect test algorithm that recognizes exact and standardized defect information in order to fundamentally resolve generated defects in industrial sites by giving artificial intelligence to SAT(Scanning Acoustic Tomograph), which previously depended on operator's decision, to find various defect information in a semiconductor package, to decide defect pattern, to reduce personal errors and then to standardize the test process was verified. In order to apply the algorithm to the lately emerging Neural Network theory, various weights were used to derive results for performance advancement plans of the defect test algorithm that promises excellent field applicability.

Clinical evaluation of atrial septal defect (심방중격결손증의 외과적 고찰)

  • Kim, Hyeon-Sun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.511-517
    • /
    • 1983
  • For the purpose of clinical analysis of secundum atrial septal defect, the patients with atrial septal defect operated on during the period from Aug. 1959 to Aug. 1983 were analysed. The age of the patients was ranged from 3 months to 60 years and there were 132 males [45.3%] patients and 145 female patients [54.6%] in this series. The most frequent type was oval type defect in 219 [86.9%]. The PAPVC were present in 7 patients of high defect group. Clinical analysis revealed 53 patients [19.9%] were asymptomatic. The QP/QS above than 3.61 were 45 patients and less than 1.5 were 24 patients. The pulmonary artery pressure was 10 to 100 mmHg. The majority of the defects were closed in primary suture and closed with a Dacron patch in 19 patients. The postoperative complications occurred in 35 patients [13.1%] and the most frequent complication was wound problem which was present in 10 patients. The hospital mortality rate was 1.6%.

  • PDF

Quantitative Evaluation of Impact Defects inside of Composite Material Plate by ESPI (ESPI를 이용한 충격손상을 받은 복합재료 내부결함의 정량평가)

  • 김경석;양광영;장호섭;지창준;윤홍석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.254-258
    • /
    • 2003
  • Electronic Speckle Pattern for quantitative evaluation of a impact defect inside of composite material plate are described. The impact on composite material makes inside delamination which is difficult to detect visual inspection and ultrasonic testing due to non-homeogenous structure. This paper proposes the quantitative evaluation technique of defects under real impact. Artificial defects are designed inside of composite plate for development of inspection technique and real defects under impact are inspected and compared with results of visual inspection.

  • PDF

Defect Evaluation of Weld Zone in Rails Using Attractor and Distance Amplitude Characteristics Curve (레일 용접부의 결함 검출을 위한 어트랙터의 구성 및 해석에 관한 연구)

  • 윤인식;고준빈;박성두
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.77-83
    • /
    • 2000
  • This study proposes the analysis and evaluation method of time series ultrasonic signal using the attractor analysis. Features extracted from time series signal analyze quantitatively characteristics of weld defects. For this purpose, analysis objective in this study is fractal dimension and attractor quadrant feature. Trajectory changes in the attractor indicated a substantial difference in fractal characteristics resulting from distance shifts such as parts of head and flange even though the types of defects are identified. These difference in characteristics of weld defects enables the evaluation of unique characteristics of defects in the weld zone. In quantitative fractal feature extraction, feature values of 3.848 in the case of part of head(crack) and 4.102 in the case of part of web(side hole) and 3.711 in the case of part of flange(crack) were proposed on the basis of fractal dimensions. Proposed attractor analysis and DAC in this study can enhance the precision rate of ultrasonic evaluation for defect signals of rail weld zone such as side hole and crack.

  • PDF