• Title/Summary/Keyword: Decoupling power control

Search Result 99, Processing Time 0.031 seconds

A Control Algorithm for Highly Efficient Operation of Auxiliary Power Unit in a Series Hybrid Electric Bus (직렬형 하이브리드 버스에서 보조동력장치의 고효율 작동을 위한 제어 알고리즘)

  • 함윤영;송승호;민병문;노태수;이재왕;이현동;김철수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.170-175
    • /
    • 2003
  • A control algorithm is developed for highly efficient operation of auxiliary power unit (APU) that consists of a diesel engine and a directly coupled induction generator in series hybrid electric Bus (SHEB). In a series hybrid configuration the APU supplies the electric power needed for maintaining the state of charge (SOC) of the battery unit in various conditions of vehicle operation. As the rotational speed of generator does not depend on the vehicle speed, an optimized operation of engine-generator unit based on the efficiency map of each component can be achieved. The output torque of diesel engine can be controlled by the amount of fuel injection, and the power converted from mechanical to electrical energy can be adjusted by generate control unit (GCU) using the decoupling vector control of torque and flux. As for the given reference of the generating power, the multiply of speed and torque, many combinations of operating speed and torque are possible. The algorithm decides the new operating point based on the engine efficiency map and generator characteristic curve. During the transition of operating points, the speed controller saturation is avoided using variable limit and filtering of generator torque reference. A test rig and SHEB consist of a 1.5L diesel engine and a 30kw induction generator are constructed by Hyundai Motor Company.

Robust Controller Design for the Regulation of Currents in a Three-phase Load (3상 부하 전류 제어를 위한 강인한 제어기 설계기법)

  • Jee, Sujung;Jo, Nam-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.17-23
    • /
    • 2013
  • The regulation of currents in a three-phase load is an important issue for electric power systems. The most popular conventional method is a decoupling controller that compensates the coupling terms arising from DQ rotating frame transformation. Although the decoupling controller achieves decent performance in the absence of load parameter uncertainties, the variation of parameters causes performance to degrade intolerably. In this paper, we propose to use disturbance observer based controller to improve the control performance in spite of the parameter uncertainties. The computer simulation study validates the effectiveness of the proposed method.

Decoupling Current Control Method of Asymmetric Six-Phase Permanent Magnet Synchronous Machine (비대칭 6상 영구자석 동기전동기의 상호 간섭을 고려한 전류 제어 방법)

  • Lim, Gyu Cheol;Han, Yongsu;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.66-68
    • /
    • 2018
  • 6상 전동기는 높은 신뢰성과 토크 리플의 저감 등의 성능 이점으로 인해 다양한 산업 분야에서 고려되고 있다. 6상 전동기는 일반적으로 두 3상 권선의 형태로 모델링할 수 있으며, 독립된 두 개의 전류 제어기를 사용하는 경우, 두 3상 권선 간의 상호 간섭 인덕턴스의 영향으로 인하여 불안정해지는 특성이 있다. 안정적인 전동기 구동을 위하여, 비대칭 6상 전동기의 상호 간섭 영향을 최소화하는 전류 제어기가 필요하다. 이를 위해, 본 연구에서는 이산 영역에서의 6상 전동기의 전류 제어 폐루프 응답 특성을 분석하고 비간섭 (Decoupling) 전류 제어기 구조를 제시한다.

  • PDF

Improvement Performance Of SPMSM With Improved Decoupling Current Controller (개선된 비간섭 전류제어기를 이용한 영구자석 동기 전동기의 성능 향상에 관한 연구)

  • Cho, Su-Eog;Kim, Jung-Su;Park, Sung-Jun;Ko, Hei-Young;Kim, Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.243-247
    • /
    • 2005
  • 본 논문에서는 영구자석 동기전동기의 운전중 간섭성분을 형성하는 고정자 인덕턴스가 변화할 경우 d축 전류의 오차로부터 고정자 인덕턴스의 변화량을 보상할 수 있는 보상기를 제안하였다. 그리고 이러한 보상기를 기존의 DDC(Dynamic Decoupling g Control)에 적용하여, 고정자 인덕턴스의 변화에 대한 강인성이 향상된 비간섭 전류제어기를 설계하였다.

  • PDF

A Study of the Three Port NPC based DAB Converter for the Bipolar DC Grid (양극성 직류 배전망에 적용 가능한 3포트 NPC 기반의 DAB 컨버터에 대한 연구)

  • Yun, Hyeok-Jin;Kim, Myoungho;Baek, Ju-Won;Kim, Ju-Yong;Kim, Hee-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.336-344
    • /
    • 2017
  • This paper presents the three-port DC-DC converter modeling and controller design procedure, which is part of the solid-state transformer (SST) to interface medium voltage AC grid to bipolar DC distribution network. Due to the high primary side DC link voltage, the proposed converter employs the three-level neutral point clamped (NPC) topology at the primary side and 2-two level half bridge circuits for each DC distribution network. For the proposed converter particular structure, this paper conducts modeling the three winding transformer and the power transfer between each port. A decoupling method is adopted to simplify the power transfer model. The voltage controller design procedure is presented. In addition, the output current sharing controller is employed for current balancing between the parallel-connected secondary output ports. The proposed circuit and controller performance are verified by experimental results using a 30 kW prototype SST system.

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.

Common-Mode Noise Suppression in Switched-Mode Power Supply Boards Using Segmentation Method (구조분할 해석기법 기반 전원보드 공통모드 노이즈 감쇠 설계)

  • Kim, Myunghoi;Roh, Dongkyu;Jeong, Sungseok;Kwak, Kyumin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.2
    • /
    • pp.142-145
    • /
    • 2018
  • In this paper, we present a design technique for the suppression of common-mode(CM) noise in switched-mode power supply boards using the segmentation method. By applying the segmentation method, the example structure is decomposed into two segments with decoupling capacitors and a recombination matrix is extracted for the segments. The effects of the decoupling capacitor on CM noise suppression are examined. The simulation time is significantly reduced on using the segmentation method.

Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator (동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어)

  • Song Seung-Ho;Kim Sung-Ju;Hahm Nyon-Kun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

Maximum Efficiency Control of a Stator Flux-Oriented Induction Motor Drive (유도전동기 고정자자속 기준제어의 최대효율제어)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.117-122
    • /
    • 2006
  • Maximum efficiency control scheme in a stator flux-oriented induction motor drive is proposed for minimizing input dc power. Flux level is decreased in steps for searching the minimum input dc power. In addition, Torque equation, slip angular frequency, and decoupling compensation current considering iron loss resistance is used. Simulation and experimental results verify the effectiveness of the proposed method.

Robust Tracking Control Based on Intelligent Sliding-Mode Model-Following Position Controllers for PMSM Servo Drives

  • El-Sousy Fayez F.M.
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.159-173
    • /
    • 2007
  • In this paper, an intelligent sliding-mode position controller (ISMC) for achieving favorable decoupling control and high precision position tracking performance of permanent-magnet synchronous motor (PMSM) servo drives is proposed. The intelligent position controller consists of a sliding-mode position controller (SMC) in the position feed-back loop in addition to an on-line trained fuzzy-neural-network model-following controller (FNNMFC) in the feedforward loop. The intelligent position controller combines the merits of the SMC with robust characteristics and the FNNMFC with on-line learning ability for periodic command tracking of a PMSM servo drive. The theoretical analyses of the sliding-mode position controller are described with a second order switching surface (PID) which is insensitive to parameter uncertainties and external load disturbances. To realize high dynamic performance in disturbance rejection and tracking characteristics, an on-line trained FNNMFC is proposed. The connective weights and membership functions of the FNNMFC are trained on-line according to the model-following error between the outputs of the reference model and the PMSM servo drive system. The FNNMFC generates an adaptive control signal which is added to the SMC output to attain robust model-following characteristics under different operating conditions regardless of parameter uncertainties and load disturbances. A computer simulation is developed to demonstrate the effectiveness of the proposed intelligent sliding mode position controller. The results confirm that the proposed ISMC grants robust performance and precise response to the reference model regardless of load disturbances and PMSM parameter uncertainties.