An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

DECOUPLING CONTROL OF AN INDUCTION MOTOR WITH RECURSIVE ADAPTATION OF ROTOR RESISTANCE

  • Kim, Gyu-Sik;Kim, Jae-Yoon;Yim, Chung-Hyuk;Kim, Joohn-Sheok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.23-28
    • /
    • 1998
  • We propose a nonlinear feedback controller that can control the induction motors with high dynamic performance by means of decoupling of motor speed and rotor flux. The nonlinear feedback controller needs the information on some motor parameters. Among them, rotor resistance varies greatly with machine temperature. A new recursive adaptation algorithm for rotor resistance which can be applied to our nonlinear feedback controller is also presented in this paper. The recursive adaptation algorithm makes the estimated value of rotor resistance track its real value. Some simulation results show that the adaptation algorithm for rotor resistance is robust against the variation of stator resistance and mutual inductance. In addition, it is computationally simple and has small estimation errors. To demonstrate the practical significance of our results, we present some experimental results.

  • PDF

Design of Gain Controller of Decoupling Control of Grid-connected Inverter with LCL Filter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.124-126
    • /
    • 2008
  • Grid Connected inverter is produced current to deliver power to grid. To provide low THD current, LCL filters is effective to filter high frequency component of current output from inverter. To provide sinusoidal waveform, there are many researchers have been proposed several controllers for grid-connected inverter controllers. Synchronous Reference Frame (SRF)-based controller is the most popular methods. SRF-based controller is capable for reducing both of zero-steady state error and phase delay. But SRF based controller is contained cross-coupling components, which generate some difficulties to analyze. In this paper, SRF based controller is analyzed. By applying decoupling control, cross-coupling component is eliminated and single phase model of the system is obtained. Through this single phase model, gain controller is designed. To reduce steady state error, proportional gain is set as high as possible, but it may produce instability. To compromise between a minimum steady state error and stability, the single phase model is evaluate through Root Locus and Bode diagram. PSIM simulation is used to verify the analysis.

  • PDF

Online Compensation of Parameter Variation Effects for Robust Interior PM Synchronous Motor Drives

  • Shrestha, Rajendra L.;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.713-718
    • /
    • 2011
  • This paper presents an online voltage disturbance estimator to achieve precise torque control of IPMSMs over a high speed operating region. The proposed design has a type of state-filter based on a Luenburger-style closed loop stator current vector observer. Utilizing the frequency response plot (FRF) approach, the estimation accuracy and the parameter sensitivities are analyzed. Accurate torque control and improved efficiency are provided with the decoupling of the effect of the parameter variations. The feasibility of the presented idea is verified by laboratory experiments.

Parallel Control of Shunt Active Power Filters in Capacity Proportion Frequency Allocation Mode

  • Zhang, Shuquan;Dai, Ke;Xie, Bin;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.419-427
    • /
    • 2010
  • A parallel control strategy in capacity proportion frequency allocation mode for shunt active power filters (APFs) is proposed to overcome some of the difficulties in high power applications. To improve the compensation accuracy and overall system stability, an improved selective harmonic current control based on multiple synchronous rotating reference coordinates is presented in a single APF unit, which approximately implements zero steady-state error compensation. The combined decoupling strategy is proposed and theoretically analyzed to simplify selective harmonic current control. Improved selective harmonic current control forms the basis for multi-APF parallel operation. Therefore, a parallel control strategy is proposed to realize a proper optimization so that the APFs with a larger capacity compensate more harmonic current and the ones with a smaller capacity compensate less harmonic current, which is very practical for accurate harmonic current compensation and stable grid operation in high power applications. This is verified by experimental results. The total harmonic distortion (THD) is reduced from 29% to 2.7% for a typical uncontrolled rectifier load with a resistor and an inductor in a laboratory platform.

단순화된 입출력선형화방법에 의한유동전동식의 강인한 속도 및 효솔제어 (Robust Speed and Efficiency Control of Induction Motors via a Simplified Input-Output Linearization Technique)

  • 김규식;고명삼;하인중;김점근
    • 대한전기학회논문지
    • /
    • 제39권10호
    • /
    • pp.1066-1074
    • /
    • 1990
  • 본 논문에서는 유동전동기에 최근에 개발된 비선형 제어이론을 적용시켜 회전자 속도와 회전자 자속사이에 간섭이 일어나지 않는 선형 시스템으로 변환시킴으로써 제안한 제어기가 유도전동기를 고성능뿐만 아니라 고효율로 제어할 수 있음을 수학적인 분석, 시뮬레이션, 그리고 실험을 통해 보였다. 제안한 제어기는 d-p동기 회전축과 x-y고정자축 사이의 변환, 전기각 속도의 적분, 그리고 전압방정식에서 역기전력과 결합항의 보상등이 필요치 않기 때문에 기존 벡터 제어기보다 계산이 간단하다는 장점을 갖고 있고 특히 전동기 매개변수의 변화에 강인한(robust) 특징을 갖고 있다. 본 논문이 제안한 설계방법은 최근에 개발된 이론인 특이섭동기법(singular perturbation technoque)과 비간섭 궤환제어(noninteracting feedback control)에 기초를 두고 있는데 실제로 이 이론들이 유도 전동기의 속도 및 효율제어에 효과적으로 적용됨을 본 논문을 통해 보이고 있다.

Bidirectional High-Frequency Link Inverter with Deadbeat Control

  • Salam, Zainal
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.726-735
    • /
    • 2009
  • This paper presents a Bidirectional High-Frequency Link (BHFL) inverter that utilizes the Deadbeat controller. The main features of this topology are the reduced size of the inverter and fewer power switches. On the secondary side of the transformer, the active rectifier employs only two power switches, thus reducing switching losses. Using this configuration, the inverter is capable of carrying a bidirectional power flow. The inverter is controlled by a Deadbeat controller, which consists of the inner current loop, outer voltage loop and a feedforward controller. Additional disturbance decoupling networks are employed to improve the system's robustness towards load variations. A 1-kVA prototype inverter has been constructed and the Deadbeat control algorithm is experimentally verified. The experimental results show that the inverter has high efficiency (91%) with low steady state output voltage total harmonics distortion (1.5%).

인쇄성능 향상을 위한 롤코터용 임프레션 실린더의 압력 제어 (New Approach to Pressure Control of a Impression Cylinder for Roll Coater)

  • 윤소남;함영복;박중호
    • 동력기계공학회지
    • /
    • 제13권3호
    • /
    • pp.59-64
    • /
    • 2009
  • This study presents a new approach to pressure control of a impression cylinder for roll coater which is a kind of face pressure control between blanket roll and impression roll. Roll-to-Roll method for printing is a very useful tool for mass production such as RFID elements, smart sensors and solar cell devices. In this study, a decupling control strategy of the roll coater which is a combination of a cylinder system, a dry system and two pressure regulators with two pneumatic cylinders was discussed. Also, the characteristics of component such as a pressure regulator having a pressure reducing function and the movement of a blanket roll and a impression cylinder were analyzed using the Matlab software. From this results, the techniques of a shock and a vibration reduction were suggested.

  • PDF

End-Effect Compensation in Linear Induction Motor Drives

  • Satvati, Mohammad Reza;Vaez-Zade, Sadegh
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.697-703
    • /
    • 2011
  • In this paper a control system with a high performance dynamic response for linear induction motors (LIMs) is proposed which takes into account the end-effect in both the machine model and the control system. Primary flux oriented control has two major drawbacks i.e. a lack of decoupling of the thrust and the flux and a possibility of system instability due to the end-effect. Both of these drawbacks have been dealt with in this paper. A flux estimation method is proposed to correct the flux orientation error caused by the end effect. Extensive motor performance evaluations under the proposed control system prove its superiority over conventional vector control.

벡터제어 유도전동기의 최대효율 운전 (Maximum Efficiency Drive of Vector-Controlled Induction Motors)

  • 윤덕용;최규하;홍순찬;백수현;이은웅
    • 전력전자학회논문지
    • /
    • 제1권1호
    • /
    • pp.27-37
    • /
    • 1996
  • This paper proposes the control algorithm for maximum efficiency drive of PWM inverter - induction motor system with high dynamic performance. If the induction motor is driven under light load with rated magnetizing current, the Iron loss is excessively large compared with the codder loss which results in doer motor efficiency. Maximum efficiency drive of an induction motor can be achieved by controlling the magnetizing current to satisfy the optimal ratio that leads the total motor loss to be a minimum value at a given speed. The proposed control algorithm essentially uses vector control technique and adopts voltage decoupling control strategy to prevent the degradation of dynamic performance due to reduced magnetizing current. To verify the proposed method, digital simulations and experiments are carried out for a squirrel-cage induction motor with the rating of 2.2[kW].

  • PDF